Zhenguo Nie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhenguo Nie has a total of 148 co-authors. Here are the top co-authors by number of shared publications:
- Xin-Jun Liu
Tsinghua University
11 shared publications - Handing Xu
Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
9 shared publications Handing Xu
Tsinghua University
8 shared publicationsXin-Jun Liu
Department of Mechanical Engineering, State Key Laboratory of Tribology in Advanced Equipment, Beijing Key Laboratory of Transformative High-end Manufacturing Equipment and Technology, Tsinghua University, Beijing, China
7 shared publications- Yaguan Li
Taiyuan University of Technology College of Mechanical and Vehicle Engineering Taiyuan, Shanxi 030024 , China
6 shared publications Fugui Xie
Tsinghua University
5 shared publications
Latest Publications
- Open Access
- 26 August 2026
- Published by Elsevier in SSRN Electronic Journal
Plantar-Pressure-Based Estimation of Lower-Limb Joint Moments after ACL Reconstruction: A Cascade Framework with an Explicit Kinematic Intermediate Representation
Background and Objective:Accurate estimation of lower-limb joint moments is important for rehabilitation monitoring after anterior cruciate ligament reconstruction (ACLR). Plantar pressure provides a portable measure of foot--ground loading and center-of-pressure (COP) progression, but direct pressure-to-moment models do not explicitly represent intermediate kinematics. This study investigated the feasibility of a two-stage cascade with an observable kinematic intermediate representation.Methods:In Stage~1, a multimodal Net4\_conv model reconstructed the bilateral three-dimensional joint angles of the hip, knee, and ankle from plantar-pressure maps and COP trajectories. In Stage~2, a bidirectional long short-term memory network with temporal attention (BiLSTM-Attention) estimated the corresponding three-dimensional joint moments from the predicted angle sequences. Data from 18 participants were collected at the preoperative baseline and 3, 6, and 12 months after ACLR. Performance was evaluated using a nested time-focused leave-one-subject-out protocol.Results:Across the four rehabilitation stages, Stage~1 achieved mean Pearson correlation coefficients of 0.80--0.87 and normalized root mean square errors (NRMSEs) of 0.23--0.25. Under the full-cascade condition, the overall participant-level correlation for joint-moment estimation was $0.8908 \pm 0.0252$, with an NRMSE of $0.1338 \pm 0.0169$. Replacing reference angles with Stage~1-predicted angles resulted in an aggregate change of $\Delta r=-0.0107 \pm 0.0172$ and $\Delta\mathrm{NRMSE}=0.0021 \pm 0.0114$. Score-weighted class activation mapping (Score-CAM) responses were concentrated around plantar-loading regions and portions of the COP progression path.Conclusions:The results support the technical feasibility of an explicit pressure-to-kinematics-to-kinetics cascade under controlled laboratory conditions. The intermediate joint-angle representation enables separate assessment of upstream kinematic reconstruction and downstream joint-moment estimation. Independent validation with wearable pressure systems is required before clinical deployment.- 26 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPlantar-Pressure-Based Estimation of Lower-Limb Joint Moments after ACL Reconstruction: A Cascade Framework with an Explicit Kinematic Intermediate Representation
Background and Objective:Accurate estimation of lower-limb joint moments is important for rehabilitation monitoring after anterior cruciate ligament reconstruction (ACLR). Plantar pressure provides a portable measure of foot--ground loading and center-of-pressure (COP) progression, but direct pressure-to-moment models do not explicitly represent intermediate kinematics. This study investigated the feasibility of a two-stage cascade with an observable kinematic intermediate representation.Methods:In Stage~1, a multimodal Net4\_conv model reconstructed the bilateral three-dimensional joint angles of the hip, knee, and ankle from plantar-pressure maps and COP trajectories. In Stage~2, a bidirectional long short-term memory network with temporal attention (BiLSTM-Attention) estimated the corresponding three-dimensional joint moments from the predicted angle sequences. Data from 18 participants were collected at the preoperative baseline and 3, 6, and 12 months after ACLR. Performance was evaluated using a nested time-focused leave-one-subject-out protocol.Results:Across the four rehabilitation stages, Stage~1 achieved mean Pearson correlation coefficients of 0.80--0.87 and normalized root mean square errors (NRMSEs) of 0.23--0.25. Under the full-cascade condition, the overall participant-level correlation for joint-moment estimation was $0.8908 \pm 0.0252$, with an NRMSE of $0.1338 \pm 0.0169$. Replacing reference angles with Stage~1-predicted angles resulted in an aggregate change of $\Delta r=-0.0107 \pm 0.0172$ and $\Delta\mathrm{NRMSE}=0.0021 \pm 0.0114$. Score-weighted class activation mapping (Score-CAM) responses were concentrated around plantar-loading regions and portions of the COP progression path.Conclusions:The results support the technical feasibility of an explicit pressure-to-kinematics-to-kinetics cascade under controlled laboratory conditions. The intermediate joint-angle representation enables separate assessment of upstream kinematic reconstruction and downstream joint-moment estimation. Independent validation with wearable pressure systems is required before clinical deployment. - Open Access
- 16 March 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (3) , 134
Real-Time Endoscopic Video Enhancement via Degradation Representation Estimation and Propagation
Endoscopic images are often degraded by uneven illumination, motion blur, and tissue occlusion, which obscure critical anatomical details and complicate surgical manipulation. This issue is particularly pronounced in single-port endoscopic surgery, where the imaging capability of the camera is further constrained by limited working space. While deep learning-based enhancement methods have demonstrated impressive performance, most existing approaches remain too computationally demanding for real-time surgical use. To address this challenge, we propose an efficient stepwise endoscopic image enhancement framework that introduces an implicit degradation representation as an intermediate feature to guide the enhancement module toward high-quality results. The framework further exploits the temporal continuity of endoscopic videos, based on the assumption that image degradation evolves smoothly over short time intervals. Accordingly, high-quality degradation representations are estimated only on key frames at fixed intervals, while the representations for the remaining frames are obtained through fast inter-frame propagation, thereby significantly improving computational efficiency while maintaining enhancement quality. Experimental results demonstrate that our method achieves an excellent balance between enhancement quality and computational efficiency. Further evaluation on the downstream segmentation task suggests that our method substantially enhances the understanding of the surgical scene, validating that implicitly learning and degradation representation propagation offer a practical pathway for real-time clinical application.
- 16 March 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (3) , 134
Open AccessReal-Time Endoscopic Video Enhancement via Degradation Representation Estimation and Propagation
Endoscopic images are often degraded by uneven illumination, motion blur, and tissue occlusion, which obscure critical anatomical details and complicate surgical manipulation. This issue is particularly pronounced in single-port endoscopic surgery, where the imaging capability of the camera is further constrained by limited working space. While deep learning-based enhancement methods have demonstrated impressive performance, most existing approaches remain too computationally demanding for real-time surgical use. To address this challenge, we propose an efficient stepwise endoscopic image enhancement framework that introduces an implicit degradation representation as an intermediate feature to guide the enhancement module toward high-quality results. The framework further exploits the temporal continuity of endoscopic videos, based on the assumption that image degradation evolves smoothly over short time intervals. Accordingly, high-quality degradation representations are estimated only on key frames at fixed intervals, while the representations for the remaining frames are obtained through fast inter-frame propagation, thereby significantly improving computational efficiency while maintaining enhancement quality. Experimental results demonstrate that our method achieves an excellent balance between enhancement quality and computational efficiency. Further evaluation on the downstream segmentation task suggests that our method substantially enhances the understanding of the surgical scene, validating that implicitly learning and degradation representation propagation offer a practical pathway for real-time clinical application.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Pattern Analysis and Machine Intelligence
- Vol. 48 (3) , 3185-3198
Rethinking Rotation-Invariant Recognition of Fine-Grained Shapes From the Perspective of Contour Points
Rotation-invariant recognition of shapes is a common challenge in computer vision. Recent approaches have significantly improved the accuracy of rotation-invariant recognition by encoding the rotational invariance of shapes as hand-crafted image features and introducing deep neural networks. However, the methods based on pixels have too much redundant information, and the critical geometric information is prone to early leakage, resulting in weak rotation-invariant recognition of fine-grained shapes. In this paper, we reconsider the shape recognition problem from the perspective of contour points rather than pixels. We propose an anti-noise rotation-invariant convolution module based on contour geometric aware for fine-grained shape recognition. The module divides the shape contour into multiple local geometric regions (LGA), where we implement finer-grained rotation-invariant coding in terms of point topological relations. We provide a deep network composed of five such cascaded modules for classification and retrieval experiments. The results show that our method exhibits excellent performance in rotation-invariant recognition of fine-grained shapes. In addition, we demonstrate that our method is robust to contour noise and the rotation centers.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Pattern Analysis and Machine Intelligence
- Vol. 48 (3) , 3185-3198
Rethinking Rotation-Invariant Recognition of Fine-Grained Shapes From the Perspective of Contour Points
Rotation-invariant recognition of shapes is a common challenge in computer vision. Recent approaches have significantly improved the accuracy of rotation-invariant recognition by encoding the rotational invariance of shapes as hand-crafted image features and introducing deep neural networks. However, the methods based on pixels have too much redundant information, and the critical geometric information is prone to early leakage, resulting in weak rotation-invariant recognition of fine-grained shapes. In this paper, we reconsider the shape recognition problem from the perspective of contour points rather than pixels. We propose an anti-noise rotation-invariant convolution module based on contour geometric aware for fine-grained shape recognition. The module divides the shape contour into multiple local geometric regions (LGA), where we implement finer-grained rotation-invariant coding in terms of point topological relations. We provide a deep network composed of five such cascaded modules for classification and retrieval experiments. The results show that our method exhibits excellent performance in rotation-invariant recognition of fine-grained shapes. In addition, we demonstrate that our method is robust to contour noise and the rotation centers.
- Open Access
Enhancing Torque Output for a Magnetic Actuation System for Robotic Spinal Distraction
Magnetically controlled spinal growing rods, used for treating early-onset scoliosis (EOS), face a critical clinical limitation: insufficient distraction force. Compounding this issue is the inherent inability to directly monitor the mechanical output of such implants in vivo, which challenges their safety and efficacy. To overcome these limitations, optimizing the rotor’s maximum torque is essential. Furthermore, defining the “continuous rotation domain” establishes a vital safety boundary for stable operation, preventing loss of synchronization and loss of control, thus safeguarding the efficacy of future clinical control strategies. In this study, a transient finite element magnetic field simulation model of a circumferentially distributed permanent magnet–rotor system was established using ANSYS Maxwell (2024). The effects of the clamp angle between the driving magnets and the rotor, the number of pole pairs, the rotor’s outer diameter, and the rotational speed of the driving magnets on the rotor’s maximum torque were systematically analyzed, and the optimized continuous rotation domain of the rotor was determined. The results indicated that when the clamp angle was set at 120°, the number of pole pairs was one, the rotor outer diameter was 8 mm, the rotor achieved its maximum torque and exhibited the largest continuous rotation domain, while the rotational speed of the driving magnets had no effect on maximum torque. Following optimization, the maximum torque of the simulation increased by 201% compared with the pre-optimization condition, and the continuous rotation domain was significantly enlarged. To validate the simulation, a rotor torque measurement setup incorporating a torque sensor was constructed. Experimental results showed that the maximum torque improved from 30 N·mm before optimization to 90 N·mm after optimization, while the driving magnets maintained stable rotation throughout the process. Furthermore, a spinal growing rod test platform equipped with a pressure sensor was developed to evaluate actuator performance and measure the maximum distraction force. The optimized growing rod achieved a peak distraction force of 413 N, nearly double that of the commercial MAGEC system, which reached only 208 N. The simulation and experimental methodologies established in this study not only optimizes the device’s performance but also provides a viable pathway for in vivo performance prediction and monitoring, addressing a critical need in smart implantable technology.
Open AccessEnhancing Torque Output for a Magnetic Actuation System for Robotic Spinal Distraction
Magnetically controlled spinal growing rods, used for treating early-onset scoliosis (EOS), face a critical clinical limitation: insufficient distraction force. Compounding this issue is the inherent inability to directly monitor the mechanical output of such implants in vivo, which challenges their safety and efficacy. To overcome these limitations, optimizing the rotor’s maximum torque is essential. Furthermore, defining the “continuous rotation domain” establishes a vital safety boundary for stable operation, preventing loss of synchronization and loss of control, thus safeguarding the efficacy of future clinical control strategies. In this study, a transient finite element magnetic field simulation model of a circumferentially distributed permanent magnet–rotor system was established using ANSYS Maxwell (2024). The effects of the clamp angle between the driving magnets and the rotor, the number of pole pairs, the rotor’s outer diameter, and the rotational speed of the driving magnets on the rotor’s maximum torque were systematically analyzed, and the optimized continuous rotation domain of the rotor was determined. The results indicated that when the clamp angle was set at 120°, the number of pole pairs was one, the rotor outer diameter was 8 mm, the rotor achieved its maximum torque and exhibited the largest continuous rotation domain, while the rotational speed of the driving magnets had no effect on maximum torque. Following optimization, the maximum torque of the simulation increased by 201% compared with the pre-optimization condition, and the continuous rotation domain was significantly enlarged. To validate the simulation, a rotor torque measurement setup incorporating a torque sensor was constructed. Experimental results showed that the maximum torque improved from 30 N·mm before optimization to 90 N·mm after optimization, while the driving magnets maintained stable rotation throughout the process. Furthermore, a spinal growing rod test platform equipped with a pressure sensor was developed to evaluate actuator performance and measure the maximum distraction force. The optimized growing rod achieved a peak distraction force of 413 N, nearly double that of the commercial MAGEC system, which reached only 208 N. The simulation and experimental methodologies established in this study not only optimizes the device’s performance but also provides a viable pathway for in vivo performance prediction and monitoring, addressing a critical need in smart implantable technology.
- Open Access
- 29 September 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-19
Machine learning based prediction of carbon concentration in carburized steel
The carbon concentration and hardness of a part’s surface can be enhanced through the carburizing-quenching process. The mechanical properties are affected by the carbon concentration distribution in the surface layer, which directly determines wear resistance and fatigue life. Carbon concentration distribution can be calculated using the FEA (Finite Element Analysis) method with an error no greater than 10% for the heat treatment engineer. However, predicting the results using machine learning method is more efficient and easier. In this paper, the carburizing numerical model is established for a 20Cr2Ni4A cylindrical part. The microstructures and hardness gradient were tested to verify the accuracy of the simulation model for the furnace samples after the carburizing process. By establishing an accurate numerical model of the carburizing process, multiple sets of process parameter combinations were designed for three different shapes: square, circle, and trapezoid. Large-scale calculations were performed, resulting in a total of 530,226 sets of samples obtained. Finally, a parameter adaptive BPNN (Backpropagation Neural Network) method based on mean shift clustering and slime mould algorithm is proposed for rapid prediction of carbon concentration distribution on the surface of parts after carburizing. By comparing the prediction accuracy and training time with other methods, the feasibility and effectiveness of the method are verified.
- 29 September 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-19
Open AccessMachine learning based prediction of carbon concentration in carburized steel
The carbon concentration and hardness of a part’s surface can be enhanced through the carburizing-quenching process. The mechanical properties are affected by the carbon concentration distribution in the surface layer, which directly determines wear resistance and fatigue life. Carbon concentration distribution can be calculated using the FEA (Finite Element Analysis) method with an error no greater than 10% for the heat treatment engineer. However, predicting the results using machine learning method is more efficient and easier. In this paper, the carburizing numerical model is established for a 20Cr2Ni4A cylindrical part. The microstructures and hardness gradient were tested to verify the accuracy of the simulation model for the furnace samples after the carburizing process. By establishing an accurate numerical model of the carburizing process, multiple sets of process parameter combinations were designed for three different shapes: square, circle, and trapezoid. Large-scale calculations were performed, resulting in a total of 530,226 sets of samples obtained. Finally, a parameter adaptive BPNN (Backpropagation Neural Network) method based on mean shift clustering and slime mould algorithm is proposed for rapid prediction of carbon concentration distribution on the surface of parts after carburizing. By comparing the prediction accuracy and training time with other methods, the feasibility and effectiveness of the method are verified.
- 22 May 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 193, 110328
Lightweight triangular mesh deformable reconstruction for low quality 3D organ models: Thickness noise and uneven topology
- 22 May 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 193, 110328
Lightweight triangular mesh deformable reconstruction for low quality 3D organ models: Thickness noise and uneven topology
- Open Access
- 16 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (8) , 4399
MC Classifier: A Classifier for 3D Mechanical Components Based on Geometric Prior Using Graph Neural Network and Attention
With an increasing number of mechanical components produced in the production pipeline, the need to classify past and new elements efficiently has been increasing. However, past methods of classifying elements have relied on traditional methods that take a long time and lack extensibility. By incorporating specific geometric local features, graph neural networks, and attention between point clouds to include local and global features, we propose a new framework called Mechanical Component Classifier (MC Classifier), which can classify components efficiently with a fast inference time and can be easily extended to classify other elements. We benchmark the performance of MC Classifier against state-of-the-art models and demonstrate its competitive potential in 3D mechanical component classification. Our findings suggest that MC Classifier has significant potential to advance 3D mechanical component classification. Our findings show that MC Classifier has significant potential to advance 3D mechanical component classification and efficient and affordable methods to streamline industrial pipelines.
- 16 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (8) , 4399
Open AccessMC Classifier: A Classifier for 3D Mechanical Components Based on Geometric Prior Using Graph Neural Network and Attention
With an increasing number of mechanical components produced in the production pipeline, the need to classify past and new elements efficiently has been increasing. However, past methods of classifying elements have relied on traditional methods that take a long time and lack extensibility. By incorporating specific geometric local features, graph neural networks, and attention between point clouds to include local and global features, we propose a new framework called Mechanical Component Classifier (MC Classifier), which can classify components efficiently with a fast inference time and can be easily extended to classify other elements. We benchmark the performance of MC Classifier against state-of-the-art models and demonstrate its competitive potential in 3D mechanical component classification. Our findings suggest that MC Classifier has significant potential to advance 3D mechanical component classification. Our findings show that MC Classifier has significant potential to advance 3D mechanical component classification and efficient and affordable methods to streamline industrial pipelines.
- 10 April 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 266, 108763
Puncture path planning algorithm of flexible needle in percutaneous nephrolithotomy with a hybrid NSGA optimizer
- 10 April 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 266, 108763
Puncture path planning algorithm of flexible needle in percutaneous nephrolithotomy with a hybrid NSGA optimizer