Mhd Anwar Orabi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mhd Anwar Orabi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Anand Kumar
Indian Institute of Technology Jodhpur
2 shared publications - Patnayakuni Ravi Prakash
Indian Institute of Technology Jodhpur
2 shared publications - Aatif Ali Khan
Department of Building Services Engineering The Hong Kong Polytechnic University Kowloon Hong Kong
1 shared publication - Asif Usmani
Hong Kong Polytechnic Univ
1 shared publication - Mohammad AlHamaydeh
American University of Sharjah
1 shared publication - Ramakanth Domada1 shared publication
Latest Publications
- 12 February 2026
- Published by Elsevier in Computers & Structures
- Vol. 323
ML-based structural response forecasting and early warning system for RC structures under fire conditions
- 12 February 2026
- Published by Elsevier in Computers & Structures
- Vol. 323
ML-based structural response forecasting and early warning system for RC structures under fire conditions
- Open Access
- 27 June 2025
- Published by Elsevier in Fire Safety Journal
- Vol. 156
Analysis of the Plasco tower in fire using an integrated simulation approach
- 27 June 2025
- Published by Elsevier in Fire Safety Journal
- Vol. 156
Open AccessAnalysis of the Plasco tower in fire using an integrated simulation approach
- 3 May 2024
- Published by Springer Nature
- p. 557-566
Performance Evaluation of RC Elements Under Standard Fire Exposure Using Finite Element Analysis Approach
- 3 May 2024
- Published by Springer Nature
- p. 557-566
Performance Evaluation of RC Elements Under Standard Fire Exposure Using Finite Element Analysis Approach
- 1 August 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 25 (4) , 04021029
Punching Shear Behavior of Synthetic Fiber–Reinforced Self-Consolidating Concrete Flat Slabs with GFRP Bars
Glass fiber–reinforced polymer (GFRP)-reinforced flat slabs offer a convenient construction option that is both simple to build and highly resistant to corrosion. The relatively low thickness of the floor plates and absence of beams results in increased susceptibility to punching shear failure, which may become the governing design factor. This paper presents an experimental investigation on the use of synthetic fiber–reinforced self-consolidating concrete (SNFRSCC) to improve punching shear capacity of GFRP-reinforced flat slabs. Synthetic fiber was used because it is inert and corrosion resistant, and SCC facilitates use of fibers in relatively high dosages without adverse effects on concrete placing quality. Six large-scale interior slabs were experimentally tested for punching shear behavior assessment. Three SNFRSCC specimens with varying longitudinal reinforcement ratios were compared with their SCC control counterparts. It was confirmed experimentally that the punching shear capacity did not display high dependency on the longitudinal reinforcement spacing. However, the punching shear capacities of the SNFRSCC specimens were marginally improved in comparison with the control specimens. In addition, the SNFRSCC specimens exhibited substantial toughness improvements (2.34 times on average). Moreover, analytical expressions were developed to estimate the punching shear capacity as well as load-rotation relationships for the GFRP-reinforced SCC and SNFRSCC slabs. The analytical expressions were based on the critical shear crack theory (CSCT). The modified CSCT predictions showed a considerable agreement with the experimentally observed load-rotation behavior and punching shear capacity for SCC and SNFRSCC specimens alike.
- 1 August 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 25 (4) , 04021029
Punching Shear Behavior of Synthetic Fiber–Reinforced Self-Consolidating Concrete Flat Slabs with GFRP Bars
Glass fiber–reinforced polymer (GFRP)-reinforced flat slabs offer a convenient construction option that is both simple to build and highly resistant to corrosion. The relatively low thickness of the floor plates and absence of beams results in increased susceptibility to punching shear failure, which may become the governing design factor. This paper presents an experimental investigation on the use of synthetic fiber–reinforced self-consolidating concrete (SNFRSCC) to improve punching shear capacity of GFRP-reinforced flat slabs. Synthetic fiber was used because it is inert and corrosion resistant, and SCC facilitates use of fibers in relatively high dosages without adverse effects on concrete placing quality. Six large-scale interior slabs were experimentally tested for punching shear behavior assessment. Three SNFRSCC specimens with varying longitudinal reinforcement ratios were compared with their SCC control counterparts. It was confirmed experimentally that the punching shear capacity did not display high dependency on the longitudinal reinforcement spacing. However, the punching shear capacities of the SNFRSCC specimens were marginally improved in comparison with the control specimens. In addition, the SNFRSCC specimens exhibited substantial toughness improvements (2.34 times on average). Moreover, analytical expressions were developed to estimate the punching shear capacity as well as load-rotation relationships for the GFRP-reinforced SCC and SNFRSCC slabs. The analytical expressions were based on the critical shear crack theory (CSCT). The modified CSCT predictions showed a considerable agreement with the experimentally observed load-rotation behavior and punching shear capacity for SCC and SNFRSCC specimens alike.