Anunay Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anunay Gupta has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Dinkar Bhasin
Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, IND
13 shared publications - Hermohander Singh Isser
Department of Cardiology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India
10 shared publications - Sourabh Agstam
Department of Cardiology, All India Institute of Medical Sciences, New Delhi, India
8 shared publications Sandeep Bansal
7 shared publications- Sandeep Bansal
Department of Cardiology, VMMC and Safdarjung Hospital, New Delhi, India
7 shared publications - Gaurav Kumar Arora
Cardiology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, Delhi, India
6 shared publications
Latest Publications
- Open Access
- 13 November 2026
- Published by Elsevier in JACC: Case Reports
Transcatheter Closure of Congenital Aorto-Pulmonary Vein Fistula Causing Recurrent Hemoptysis
- 13 November 2026
- Published by Elsevier in JACC: Case Reports
Open AccessTranscatheter Closure of Congenital Aorto-Pulmonary Vein Fistula Causing Recurrent Hemoptysis
- Open Access
- 24 October 2026
- Published by Elsevier in JACC: Case Reports
- p. 110420
Right Ventricular Hydatid Cyst
- 24 October 2026
- Published by Elsevier in JACC: Case Reports
- p. 110420
Open AccessRight Ventricular Hydatid Cyst
- Open Access
- 17 June 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (28) , 108555
Right Atrial Myxoma With Dual Coronary Artery Feeding
- 17 June 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (28) , 108555
Open AccessRight Atrial Myxoma With Dual Coronary Artery Feeding
- 14 May 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (11) , 1812-1815
Tied up in the Lab: An Unexpected Catheter Knot in the Arterial System
Catheter knotting is a rare but potentially serious complication encountered during electrophysiological procedures. We report an unusual case of catheter ablation for premature ventricular complexes (PVCs) arising from anterolateral papillary muscle, where a ThermoCool SmartTouch (ST) catheter (Biosense Webster, Irvine, CA) developed a knot within the arterial system during transaortic mapping. The knot formed after the catheter was inadvertently withdrawn into the ascending aorta and re‐advanced, leading to looping and tip entrapment. Standard maneuvers to untie the knot were unsuccessful. As a novel bailout strategy, the external portion of the catheter was cut near the handle and a large‐bore 8.5 SL0 sheath (Swartz Braided SL Transseptal Guiding Introducer Sheath; length 63 cm) was advanced over it. The knotted catheter was then maneuvered against the aortic valve, and controlled mechanical contact led to successful loosening of knot and sheath retrieval. This case underscores the importance of early recognition, careful manipulation, and innovative problem‐solving in managing rare mechanical complications in the cardiac electrophysiology lab.
- 14 May 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (11) , 1812-1815
Tied up in the Lab: An Unexpected Catheter Knot in the Arterial System
Catheter knotting is a rare but potentially serious complication encountered during electrophysiological procedures. We report an unusual case of catheter ablation for premature ventricular complexes (PVCs) arising from anterolateral papillary muscle, where a ThermoCool SmartTouch (ST) catheter (Biosense Webster, Irvine, CA) developed a knot within the arterial system during transaortic mapping. The knot formed after the catheter was inadvertently withdrawn into the ascending aorta and re‐advanced, leading to looping and tip entrapment. Standard maneuvers to untie the knot were unsuccessful. As a novel bailout strategy, the external portion of the catheter was cut near the handle and a large‐bore 8.5 SL0 sheath (Swartz Braided SL Transseptal Guiding Introducer Sheath; length 63 cm) was advanced over it. The knotted catheter was then maneuvered against the aortic valve, and controlled mechanical contact led to successful loosening of knot and sheath retrieval. This case underscores the importance of early recognition, careful manipulation, and innovative problem‐solving in managing rare mechanical complications in the cardiac electrophysiology lab.
- Open Access
- 24 January 2026
- Published by Springer Nature in BMC Complementary Medicine and Therapies
- Vol. 26 (1)
Efficacy of Ayurveda interventions (Pushkar Guggulu and Haritaki) as an adjunct to standard care in stable coronary artery disease: study protocol for a double-blind, randomized controlled study
Coronary artery disease (CAD) is a substantial contributor to cardiovascular-related morbidity and mortality worldwide. Contemporary medications for CAD ma
- 24 January 2026
- Published by Springer Nature in BMC Complementary Medicine and Therapies
- Vol. 26 (1)
Open AccessEfficacy of Ayurveda interventions (Pushkar Guggulu and Haritaki) as an adjunct to standard care in stable coronary artery disease: study protocol for a double-blind, randomized controlled study
Coronary artery disease (CAD) is a substantial contributor to cardiovascular-related morbidity and mortality worldwide. Contemporary medications for CAD ma
- Open Access
- 3 December 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (39) , 106141
Colistin-Induced Bartter-Like Syndrome With Torsades de Pointes
- 3 December 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (39) , 106141
Open AccessColistin-Induced Bartter-Like Syndrome With Torsades de Pointes
- 15 July 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (9) , 2068-2070
Feasibility of Upfront Surgical Subxiphoid Epicardial Access for Hybrid Ablation of Ventricular Tachycardia
- 15 July 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (9) , 2068-2070
Feasibility of Upfront Surgical Subxiphoid Epicardial Access for Hybrid Ablation of Ventricular Tachycardia
- Open Access
- 6 March 2025
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 25 (2) , 112-117
Tachycardia induced cardiomyopathy due to ectopic atrial tachycardia originating from the atrial appendage: A case series and review of literature
- 6 March 2025
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 25 (2) , 112-117
Open AccessTachycardia induced cardiomyopathy due to ectopic atrial tachycardia originating from the atrial appendage: A case series and review of literature
- Open Access
- 1 September 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (9) , ytae482
Accidental cannulation of amoebic liver abscess during pericardiocentesis: a case report
Background: Amoebiasis is a prevalent infection in the tropics and can sometimes present as liver abscess. Cardiac tamponade is an uncommon complication of ruptured amoebic liver abscess requiring urgent pericardiocentesis, which has a high success rate, but procedural complications can include injury to cardiac chambers, abdominal viscera, and even death. This case underscores the approach to diagnose and manage an unintended visceral puncture during pericardiocentesis, which is a rare but life-threatening complication. Case summary: A 41-year-old male presented with intermittent fever over 2 months and chest pain for 15 days. Echocardiography revealed a significant pericardial effusion causing cardiac tamponade. In an emergency setting, percutaneous pericardiocentesis was attempted to drain the effusion. However, the pigtail inadvertently punctured a sizable liver abscess. Consequently, another pigtail was inserted into the pericardial cavity to successfully drain the effusion. Patient was discharged on Day 12 and is doing well at 6 months follow-up. Discussion: A previously undiagnosed case of a ruptured amoebic liver abscess presented with the uncommon complication of cardiac tamponade, necessitating emergency pericardiocentesis, which inadvertently led to the cannulation of the liver abscess. This case underscores the significance of image-guided pericardiocentesis in minimizing procedural complications. This case also highlights the intricacies of addressing accidental visceral puncture during pericardiocentesis, specially involving the liver. It also underscores the need to consider the possibility of a ruptured amoebic liver abscess when anchovy sauce-like pus is drained from pericardial cavity, especially in high epidemiologically prevalent country like India.
- 1 September 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (9) , ytae482
Open AccessAccidental cannulation of amoebic liver abscess during pericardiocentesis: a case report
Background: Amoebiasis is a prevalent infection in the tropics and can sometimes present as liver abscess. Cardiac tamponade is an uncommon complication of ruptured amoebic liver abscess requiring urgent pericardiocentesis, which has a high success rate, but procedural complications can include injury to cardiac chambers, abdominal viscera, and even death. This case underscores the approach to diagnose and manage an unintended visceral puncture during pericardiocentesis, which is a rare but life-threatening complication. Case summary: A 41-year-old male presented with intermittent fever over 2 months and chest pain for 15 days. Echocardiography revealed a significant pericardial effusion causing cardiac tamponade. In an emergency setting, percutaneous pericardiocentesis was attempted to drain the effusion. However, the pigtail inadvertently punctured a sizable liver abscess. Consequently, another pigtail was inserted into the pericardial cavity to successfully drain the effusion. Patient was discharged on Day 12 and is doing well at 6 months follow-up. Discussion: A previously undiagnosed case of a ruptured amoebic liver abscess presented with the uncommon complication of cardiac tamponade, necessitating emergency pericardiocentesis, which inadvertently led to the cannulation of the liver abscess. This case underscores the significance of image-guided pericardiocentesis in minimizing procedural complications. This case also highlights the intricacies of addressing accidental visceral puncture during pericardiocentesis, specially involving the liver. It also underscores the need to consider the possibility of a ruptured amoebic liver abscess when anchovy sauce-like pus is drained from pericardial cavity, especially in high epidemiologically prevalent country like India.
- Open Access
- 31 January 2024
- Published by Wiley
Sudden QRS widening while ablating a concealed left accessory pathway during left ventricular pacing
- 31 January 2024
- Published by Wiley
Open AccessSudden QRS widening while ablating a concealed left accessory pathway during left ventricular pacing