Morgan I. Ivy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Morgan I. Ivy has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Robin Patel
Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic
3 shared publications - Katyayini Sharma
Mayo Clinic, Rochester, Minnesota, USA
2 shared publications - Matthew P. Abdel
Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
2 shared publications Aaron J Tande
Division of Infectious Diseases, Department of Medicine, Mayo Clinic, Rochester, Minnesota, USA
1 shared publication- Aaron Joseph Tande
Division of Public Health, Infectious Diseases, and Occupational Medicine, Mayo Clinic , Rochester, Minnesota
1 shared publication Arlen D Hanssen
Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA
1 shared publication
Latest Publications
- 1 June 2021
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (6) , 1119-1126
Synovial fluid α defensin has comparable accuracy to synovial fluid white blood cell count and polymorphonuclear percentage for periprosthetic joint infection diagnosis
Aims: The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Methods: Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm3 and ≥ 65% for TKA and ≥ 3,000 cells/mm3 and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar’s test and area under the receiver operating characteristic curve (AUC) analysis. Results: Expert consensus classified 18 arthroplasies as having failed due to PJI and 81 due to aseptic failure. Using these classifications, the calculated sensitivity and specificity of AD LFA was 83.3% (95% confidence interval (CI) 58.6 to 96.4) and 93.8% (95% CI 86.2 to 98.0), respectively. Sensitivity and specificity of AD ELISA was 83.3% (95% CI 58.6 to 96.4) and 96.3% (95% CI 89.6 to 99.2), respectively. There was no statistically significant difference between sensitivity (p = 1.000) or specificity (p = 0.157) of the two AD assays. AUC for AD LFA was 0.891. In comparison, AUC for synovial WBC count, PMN%, and the combination of the two values was 0.821 (sensitivity p = 1.000, specificity p < 0.001), 0.886 (sensitivity p = 0.317, specificity p = 0.011), and 0.926 (sensitivity p = 0.317, specificity p = 0.317), respectively. Conclusion: The diagnostic accuracy of synovial AD for PJI diagnosis is comparable and not statistically superior to that of synovial WBC count plus PMN% combined. Cite this article: Bone Joint J 2021;103-B(6):1119–1126.
- 1 June 2021
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (6) , 1119-1126
Synovial fluid α defensin has comparable accuracy to synovial fluid white blood cell count and polymorphonuclear percentage for periprosthetic joint infection diagnosis
Aims: The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Methods: Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm3 and ≥ 65% for TKA and ≥ 3,000 cells/mm3 and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar’s test and area under the receiver operating characteristic curve (AUC) analysis. Results: Expert consensus classified 18 arthroplasies as having failed due to PJI and 81 due to aseptic failure. Using these classifications, the calculated sensitivity and specificity of AD LFA was 83.3% (95% confidence interval (CI) 58.6 to 96.4) and 93.8% (95% CI 86.2 to 98.0), respectively. Sensitivity and specificity of AD ELISA was 83.3% (95% CI 58.6 to 96.4) and 96.3% (95% CI 89.6 to 99.2), respectively. There was no statistically significant difference between sensitivity (p = 1.000) or specificity (p = 0.157) of the two AD assays. AUC for AD LFA was 0.891. In comparison, AUC for synovial WBC count, PMN%, and the combination of the two values was 0.821 (sensitivity p = 1.000, specificity p < 0.001), 0.886 (sensitivity p = 0.317, specificity p = 0.011), and 0.926 (sensitivity p = 0.317, specificity p = 0.317), respectively. Conclusion: The diagnostic accuracy of synovial AD for PJI diagnosis is comparable and not statistically superior to that of synovial WBC count plus PMN% combined. Cite this article: Bone Joint J 2021;103-B(6):1119–1126.
- 2 June 2020
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 38 (12) , 2664-2674
Comparative analysis of 23 synovial fluid biomarkers for hip and knee periprosthetic joint infection detection
There is interest in novel synovial fluid biomarkers for the detection of periprosthetic joint infection (PJI). Here, we assessed the diagnostic accuracy of 23 simple or sophisticated synovial fluid biomarkers for periprosthetic hip or knee infection detection. One hundred seven subjects were studied, 57 of whom had aseptic failure (AF) and 50 PJI. The following synovial fluid biomarkers were tested using spectrophotometric assays, immunoassays, lateral flow tests, or test strips: leukocyte count, monocyte percentage, lymphocyte percentage, neutrophil percentage, C‐reactive protein (CRP), glucose, lactate, granulocyte‐macrophage colony‐stimulating factor, interferon‐γ, interleukin‐1β (IL‐1β), IL‐2, IL‐4, IL‐5, IL‐6, IL‐8, IL‐10, IL‐12p70, IL‐13, IL‐17A, IL‐23, tumor necrosis factor‐α, α‐defensin, and leukocyte esterase. The best‐performing synovial fluid biomarkers to differentiate PJI from AF—that is, those with highest area under the curve compared to all other biomarkers—were leukocyte count, percent neutrophils and percent monocytes, CRP, and α‐defensin (P < .0001).
- 2 June 2020
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 38 (12) , 2664-2674
Comparative analysis of 23 synovial fluid biomarkers for hip and knee periprosthetic joint infection detection
There is interest in novel synovial fluid biomarkers for the detection of periprosthetic joint infection (PJI). Here, we assessed the diagnostic accuracy of 23 simple or sophisticated synovial fluid biomarkers for periprosthetic hip or knee infection detection. One hundred seven subjects were studied, 57 of whom had aseptic failure (AF) and 50 PJI. The following synovial fluid biomarkers were tested using spectrophotometric assays, immunoassays, lateral flow tests, or test strips: leukocyte count, monocyte percentage, lymphocyte percentage, neutrophil percentage, C‐reactive protein (CRP), glucose, lactate, granulocyte‐macrophage colony‐stimulating factor, interferon‐γ, interleukin‐1β (IL‐1β), IL‐2, IL‐4, IL‐5, IL‐6, IL‐8, IL‐10, IL‐12p70, IL‐13, IL‐17A, IL‐23, tumor necrosis factor‐α, α‐defensin, and leukocyte esterase. The best‐performing synovial fluid biomarkers to differentiate PJI from AF—that is, those with highest area under the curve compared to all other biomarkers—were leukocyte count, percent neutrophils and percent monocytes, CRP, and α‐defensin (P < .0001).
- 1 September 2018
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 56 (9)
Direct Detection and Identification of Prosthetic Joint Infection Pathogens in Synovial Fluid by Metagenomic Shotgun Sequencing
Background: Metagenomic shotgun sequencing has the potential to transform how serious infections are diagnosed by offering universal, culture-free pathogen detection. This may be especially advantageous for microbial diagnosis of prosthetic joint infection (PJI) by synovial fluid analysis, since synovial fluid cultures are not universally positive, and synovial fluid is easily obtained pre-operatively. We applied a metagenomics-based approach to synovial fluid in an attempt to detect microorganisms in 168 failed total knee arthroplasties.
- 1 September 2018
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 56 (9)
Direct Detection and Identification of Prosthetic Joint Infection Pathogens in Synovial Fluid by Metagenomic Shotgun Sequencing
Background: Metagenomic shotgun sequencing has the potential to transform how serious infections are diagnosed by offering universal, culture-free pathogen detection. This may be especially advantageous for microbial diagnosis of prosthetic joint infection (PJI) by synovial fluid analysis, since synovial fluid cultures are not universally positive, and synovial fluid is easily obtained pre-operatively. We applied a metagenomics-based approach to synovial fluid in an attempt to detect microorganisms in 168 failed total knee arthroplasties.