TLTao Liu

Tao Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tao Liu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Fu Zheng

    Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electrical and Electronic Engineering, Tianjin University of Technology, Tianjin 300384, China

    1 shared publication
  • Junpeng Cui

    School of Software and Communication, Tianjin Sino-German University of Applied Sciences, Tianjin 300350, China

    1 shared publication
  • Libin Zhu

    Well Testing Sub-Company, CNPC Bohai Drilling Engineering Company Limited,Tianjin, China

    1 shared publication
  • Meng Han

    Deepinfar Ocean Technology Co., Ltd., Building #28, Tianjin Binhai Innovation Park, Tianjin 300000, China

    1 shared publication
  • Rui Zhang

    School of Electrical and Information Engineering, Tianjin University, Tianjin, China

    1 shared publication
  • Sheng Xu

    Department of Software and Communication, Tianjin Sino-German University of Applied Sciences, Tianjin 300072, China

    1 shared publication

Latest Publications

  • Open Access

    Surface Acoustic Wave DMMP Gas Sensor with a Porous Graphene/PVDF Molecularly Imprinted Sensing Membrane

    by Sheng Xu, Rui Zhang, Junpeng Cui, Tao Liu, Xiuli Sui, Meng Han, Fu Zheng, Xiaoguang Hu

    In this paper, surface acoustic wave (SAW) sensors containing porous graphene/PVDF (polyvinylidene fluoride) molecularly imprinted sensitive membrane for DMMP gas detection were investigated. A 433 MHz ST-cut quartz SAW resonator was used to convert gas concentration changes into frequency shifts by the sensors. The porous graphene/PVDF film was fabricated on the sensor’s surface by using the tape-casting method. DMMP molecules were adsorbed on the porous structure sensing film prepared by the 2-step method to achieve the specific recognition effect. The sensitivity of the sensor could reach −1.407 kHz·ppm−1. The response time and recovery time of the SAW sensor with porous graphene/PVDF sensing membrane were about 4.5 s and 5.8 s at the concentration of 10 ppm, respectively. The sensor has good anti-interference ability to most gases in the air.


  • Design of the equaliser with lower-order Chebyshev polynomial for bandwidth expansion of transmission channel of logging cable

    by Tao Liu, Libin Zhu, Xianhui Yang, Wenxiao Qiao

    This paper introduces the logging cable equaliser. In logging engineering, the seven-core cable has been widely used as transmission medium, which has a narrower effective bandwidth. In order to improve the data transfer rate, it is necessary to expand the effective bandwidth. We have proposed a design method of equaliser based on Chebyshev polynomial in this paper. This scheme could compensate the high-order channel attenuation and expand the effective width with lower-order Chebyshev polynomials. The equaliser could also compensate the phase shift of the transfer data which is caused by the non-linear characteristic of logging cable. We have also simulated the scheme with Matlab and produced the circuit board to demonstrate the practical application effect. It is proved that for the non-linear logging transmission channel, the proposed scheme has a good effect on the expansion of the effective bandwidth. It could provide enough bandwidth to enhance the data transmission rate.