Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abdullah Khasawneh has a total of 81 co-authors. Here are the top co-authors by number of shared publications:

  • Junichi Asaumi

    Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan

    7 shared publications
  • Kentaro Hamada

    Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan

    6 shared publications
  • Majd Barham

    Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan

    6 shared publications
  • Masahiro Kuroda

    Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama 700-8558, Japan

    6 shared publications
  • Nouha Tekiki

    Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan

    6 shared publications
  • Hinata Ishizaka

    Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan

    5 shared publications

Latest Publications

  • Open Access

    BCR, not TCR, repertoire diversity is associated with favorable COVID-19 prognosis

    by Faith Jessica Paran, Rieko Oyama, Abdullah Khasawneh, Tomohiko Ai, Hendra Saputra Ismanto, Aalaa Alrahman Sherif, Dianita Susilo Saputri, Chikako Ono, Mizue Saita, Satomi Takei, et al.

    The SARS-CoV-2 pandemic has had a widespread and severe impact on society, yet there have also been instances of remarkable recovery, even in critically ill patients. In this study, we used single-cell RNA sequencing to analyze the immune responses in recovered and deceased COVID-19 patients during moderate and critical stages. The study included three unvaccinated patients from each outcome category. Although expanded T cell receptor (TCR) clones were predominantly SARS-CoV-2-specific, they represented only a small fraction of the total repertoire in all patients. In contrast, while deceased patients exhibited monoclonal B cell receptor (BCR) expansions without COVID-19 specificity, survivors demonstrated diverse and specific BCR clones. These findings suggest that neither TCR diversity nor BCR monoclonal expansions are sufficient for viral clearance and subsequent recovery. Differential gene expression analysis revealed that protein biosynthetic processes were enriched in survivors, but that potentially damaging mitochondrial ATP metabolism was activated in the deceased. This study underscores that BCR repertoire diversity, but not TCR diversity, correlates with favorable outcomes in COVID-19.


  • Open Access

    Evaluation of calculation processes of apparent diffusion coefficient subtraction method (ASM) imaging

    by Majd Barham, Masahiro Kuroda, Yuuki Yoshimura, Kentaro Hamada, Abdullah Khasawneh, Kohei Sugimoto, Kohei Konishi, Nouha Tekiki, Irfan Sugianto, Babatunde O Bamgbose, et al.

    A number of restricted diffusion (RD) imaging techniques, such as diffusion kurtosis (DK) imaging and Q space imaging, have been developed and proven to be useful for the diagnosis of diseases, including cerebral gliomas and cerebrovascular infarction. In particular, apparent diffusion coefficient (ADC) subtraction method (ASM) imaging has become available recently as a novel RD imaging technique. ASM is based on the difference between the ADC values in an image pair of two ADC maps, ADC basic (ADCb) and ADC modify (ADCm), which are created from diffusion-weighted images taken using short and long effective diffusion times, respectively. The present study aimed to assess the potential of different types of ASM imaging by comparing them with DK imaging which is the gold-standard RD imaging technique. In the present basic study using both polyethylene glycol phantom and cell-containing bio-phantom, three different types of ASM images were created using different calculation processes. ASM/A is an image calculated by dividing the absolute difference between ADCb and ADCm by ADCb several times. By contrast, ASM/S is an image created by dividing the absolute difference between ADCb and ADCm by the standard deviation of ADCb several times. As for positive ASM/A image (PASM/A), the positive image, which was resultant after subtracting ADCb from ADCm, was divided by ADCb several times. A comparison was made between the types of ASM and DK images. The results showed the same tendency between ASM/A in addition to both ASM/S and PASM/A. By increasing the number of divisions by ADCb from three to five times, ASM/A images transformed from DK-mimicking to more RD-sensitive images compared with DK images. These observations suggest that ASM/A images may prove useful for future clinical applications in RD imaging protocols for the diagnosis of diseases.

  • Open Access

    Performance evaluation of the Ortho VITROS SARS-CoV-2 Spike-Specific Quantitative IgG test by comparison with the surrogate virus neutralizing antibody test and clinical assessment

    by Maika Takahashi, Kaori Saito, Tomohiko Ai, Shuko Nojiri, Abdullah Khasawneh, Faith Jessica Paran, Yuki Horiuchi, Satomi Takei, Takamasa Yamamoto, Mitsuru Wakita, et al.

    Background: Despite the worldwide campaigns of COVID-19 vaccinations, the pandemic is still a major medical and social problem. The Ortho VITROS SARS-CoV-2 spike-specific quantitative IgG (VITROS S-IgG) assay has been developed to assess neutralizing antibody (NT antibody) against SARS-CoV-2 spike (S) antibodies. However, it has not been evaluated in Japan, where the total cases and death toll are lower than the rest of the world. Methods: The clinical performance of VITROS S-IgG was evaluated by comparing with the NT antibody levels measured by the surrogate virus neutralizing antibody test (sVNT). A total of 332 serum samples from 188 individuals were used. Of these, 219 samples were from 75 COVID-19 patients: 96 samples from 20 severe/critical cases (Group S), and 123 samples from 55 mild/moderate cases (Group M). The remaining 113 samples were from 113 healthcare workers who had received 2 doses of the BNT162b2 vaccine. Results: VITROS S-IgG showed good correlation with the cPass sVNT assay (Spearman rho = 0.91). Both VITROS S-IgG and cPass sVNT showed significantly higher plateau levels of antibodies in Group S compared to Group M. Regarding the humoral immune responses after BNT162b2 vaccination, individuals who were negative for SARS-CoV-2 nucleocapsid (N)-specific antibodies had statistically lower titers of both S-IgG and sVNT compared to individuals with a history of COVID-19 and individuals who were positive for N-specific antibodies without history of COVID-19. In individuals who were positive for N-specific antibodies, S-IgG and sVNT titers were similar to individuals with a history of COVID-19. Conclusions: Although the automated quantitative immunoassay VITROS S-IgG showed a reasonable correlation with sVNT antibodies, there is some discrepancy between Vitros S-IgG and cPass sVNT in milder cases. Thus, VITROS S-IgG can be a useful diagnostic tool in assessing the immune responses to vaccination and herd immunity. However, careful analysis is necessary to interpret the results.


  • Open Access

    Performance evaluation of the Roche Elecsys® Anti-SARS-CoV-2 immunoassays by comparison with neutralizing antibodies and clinical assessment

    by Satomi Takei, Tomohiko Ai, Takamasa Yamamoto, Gene Igawa, Takayuki Kanno, Minoru Tobiume, Makoto Hiki, Kaori Saito, Abdullah Khasawneh, Mitsuru Wakita, et al.

    Quantitative measurement of SARS-CoV-2 neutralizing antibodies is highly expected to evaluate immune status, vaccine response, and antiviral therapy. The Elecsys® Anti-SARS-CoV-2 S (Elecsys® anti-S) was developed to measure anti-SARS-CoV-2 S proteins. We sought to investigate whether Elecsys® anti-S can be used to predict neutralizing activities in patients’ serums using an authentic virus neutralization assay. One hundred forty-six serum samples were obtained from 59 patients with COVID-19 at multiple time points. Of the 59 patients, 44 cases were included in Group M (mild 23, moderate 21) and produced 84 samples (mild 35, moderate 49), while 15 cases were included in Group S (severe 11, critical 4) and produced 62 samples (severe 43, critical 19). The neutralization assay detected 73% positive cases, and Elecsys® anti-S and Elecsys® Anti-SARS-CoV-2 (Elecsys® anti-N) showed 72% and 66% positive cases, respectively. A linear correlation between the Elecsys® anti-S assay and the neutralization assay were highly correlated (r = 0.7253, r2 = 0.5261) than a linear correlation between the Elecsys® anti-N and neutralization assay (r = 0.5824, r2 = 0.3392). The levels of Elecsys® anti-S antibody and neutralizing activities were significantly higher in Group S than in Group M after 6 weeks from onset of symptoms (p < 0.05). Conversely, the levels of Elecsys® anti-N were comparable in both groups. Three immunosuppressed patients, including cancer patients, showed low levels of anti-S and anti-N antibodies and neutralizing activities throughout the measurement period, indicating the need for careful follow-up. Our data indicate that Elecsys® anti-S can predict the neutralization antibodies in COVID-19.


  • Open Access

    Influence of mesiodens on adjacent teeth and the timing of its safe removal

    by Majd Barham, Shunsuke Okada, Miki Hisatomi, Abdullah Khasawneh, Nouha Tekiki, Yohei Takeshita, Toshiyuki Kawazu, Mariko Fujita, Yoshinobu Yanagi, Junichi Asaumi

    Barham M, et al. Imaging Sci Dent. 2022 Jan;52:e4. https://doi.org/10.5624/isd.20210218


  • Open Access

    New field‑in‑field with two reference points method for whole breast radiotherapy: Dosimetric analysis and radiation‑induced skin toxicities assessment

    by Nouha Tekiki, Masahiro Kuroda, Hinata Ishizaka, Abdullah Khasawneh, Majd Barham, Kentaro Hamada, Kohei Konishi, Kohei Sugimoto, Kuniaki Katsui, Soichi Sugiyama, et al.

    The usefulness of the field‑in‑field with two reference points (FIF w/ 2RP) method, in which the dose reference points are set simultaneously at two positions in the irradiation field and the high‑dose range is completely eliminated, was examined in the present study with the aim of decreasing acute skin toxicity in adjuvant breast radiotherapy (RT). A total of 573 patients with breast cancer who underwent postoperative whole breast RT were classified into 178 cases with wedge (W) method, 142 cases with field‑in‑field without 2 reference points (FIF w/o 2RP) method and 253 cases with FIF w/ 2RP method. Using the FIF w/ 2RP method, the high‑dose range was the lowest among the three irradiation methods. The planning target volume (PTV) V105% and the breast PTV for evaluation (BPe) V105% decreased to 0.09 and 0.10%, respectively. The FIF w/ 2RP method vs. the FIF w/o 2RP method had a strong association (η) with PTV V105% (η=0.79; P<0.001) and BPe V105% (η=0.76; P<0.001). The FIF w/ 2RP method had a significant impact on lowering the skin toxicity grade in weeks 3 and 4, and increasing the occurrence of skin toxicity grade 0. The FIF w/ 2RP method vs. the W method had a moderate association with skin toxicity grade at week 3 (η=0.49; P<0.001). Using the FIF w/ 2RP method, the high‑dose range V105% of the target decreased to 0%, and skin adverse events were decreased in conjunction. For patients with early‑stage breast cancer, particularly patients with relatively small‑sized breasts, the FIF w/ 2RP method may be an optimal irradiation method.


  • Investigation into the Effect of Breast Volume on Irradiation Dose Distribution in Asian Women with Breast Cancer

    by Hinata Ishizaka, Masahiro Kuroda, Nouha Tekiki, Abdullah Khasawneh, Majd Barham, Kentaro Hamada, Kohei Konishi, Kohei Sugimoto, Kuniaki Katsui, Soichi Sugiyama, et al.

    Reports on irradiation dose distribution in breast cancer radiotherapy with sufficient sample size are limited in Asian patients. Elucidating dose distribution in Asian patients is particularly important as their breast volume differs compared to patients in Europe and North America. Here, we examined dose distribution in the irradiation field relative to breast volume for three irradiation methods historically used in our facility. We investigated the influence of breast volume on each irradiation method for Asian women. A total of 573 women with early-stage breast cancer were treated with breast-conserving surgery and adjuvant radiotherapy. Three methods were compared: wedge (W), field-in-field (FIF), and wedge-field-in-field (W-FIF). In patients with small breast volume, FIF decreased low- and high-dose areas within the planning target volume, and increased optimal dose area more than W. In patients with medium and large breast volumes, FIF decreased high-dose area more than W. The absolute values of correlation coefficients of breast volume to low-, optimal-, and high-dose areas and mean dose were significantly lower in FIF than in W. The correlation coefficients of V107% were 0.00 and 0.28 for FIF and W, respectively. FIF is an excellent irradiation method that is less affected by breast volume than W in Asian breast cancer patients.


    • 1 April 2021
      • Vol. 75  (2) , 139-145

    Evaluation of the Imaging Process for a Novel Subtraction Method Using Apparent Diffusion Coefficient Values

    by Kentaro Hamada, Masahiro Kuroda, Yuuki Yoshimura, Abdullah Khasawneh, Majd Barham, Nouha Tekiki, Irfan Sugianto, Babatunde O. Bamgbose, Kohei Konishi, Kohei Sugimoto, et al.

    Diffusion-weighted imaging may be used to obtain the apparent diffusion coefficient (ADC), which aids the diagnosis of cerebral infarction and tumors. An ADC reflects elements of free diffusion. Diffusion kurtosis imaging (DKI) has attracted attention as a restricted diffusion imaging technique. The ADC subtraction method (ASM) was developed to visualize restricted diffusion with high resolution by using two ADC maps taken with different diffusion times. We conducted the present study to provide a bridge between the reported basic ASM research and clinical research. We developed new imaging software for clinical use and evaluated its performance herein. This software performs the imaging process automatically and continuously at the pixel level, using ImageJ software. The new software uses a macro or a plugin which is compatible with various operating systems via a Java Virtual Machine. We tested the new imaging software's performance by using a Jurkat cell bio-phantom, and the statistical evaluation of the performance clarified that the ASM values of 99.98% of the pixels in the bio-phantom and physiological saline were calculated accurately (p<0.001). The new software may serve as a useful tool for future clinical applications and restricted diffusion imaging research.


  • Development of a novel phantom using polyethylene glycol for the visualization of restricted diffusion in diffusion kurtosis imaging and apparent diffusion coefficient subtraction method

    by Abdullah Khasawneh, Masahiro Kuroda, Yuuki Yoshimura, Irfan Sugianto, Babatunde O. Bamgbose, Kentaro Hamada, Majd Barham, Nouha Tekiki, Kohei Konishi, Kohei Sugimoto, et al.

    The present study aimed to investigate whether polyethylene glycol (PEG) phantoms have the potential to be used as standard phantoms for magnetic resonance imaging (MRI) in order to visualize restricted diffusion in diffusion kurtosis imaging (DKI), the ADC subtraction method (ASM) and the apparent diffusion coefficient (ADC). Diffusion-weighted images of 0-120 mM PEG phantoms were captured to create ADC, DKI and ASM images with post-processing. ASM is a recently developed method for restricted diffusion imaging using the readout segmentation of long variable echo-train sequences. As the PEG concentration increases, the ADC value decreases. Conversely, an increase in DKI and ASM values is associated with increasing PEG concentration. Formulae were constructed to represent the association between PEG concentrations and ADC, DKI and ASM values. These formulae can be used to determine the required PEG concentrations to mimic arbitrary ADC, DKI and ASM values of certain diseases, including tumors and infarctions. Validation experiments were conducted using bio-phantoms and clarified that the PEG phantoms cover the range of ADC and DKI values reported in previous clinical research using 3T MRI. PEG phantoms may be useful for future MRI research involving restricted diffusion.


  • Open Access

    Incidental findings in the thyroid gland on computed tomography images of the oral and maxillofacial region

    by Abdullah Khasawneh, Yohei Takeshita, Miki Hisatomi, Toshiyuki Kawazu, Mariko Fujita, Shunsuke Okada, Yuri Namba, Yudai Shimizu, Yoshinobu Yanagi, Junichi Asaumi

    The numbers of abnormal findings incidentally detected in adjacent regions are increasing with advances in imaging modalities. The present study aimed to examine the prevalence and characteristics of incidental findings in the thyroid gland on computed tomography (CT) images of the oral and maxillofacial region. CT scans of the oral and maxillofacial region in patients obtained between January 2012 and December 2016 were retrospectively reviewed. Images that revealed incidental findings in the thyroid gland, including nodules, were recorded, together with the sizes and characteristics of the findings. The Japan Association of Breast and Thyroid Sonology (JABTS) guidelines were used for classification. The rate of descriptions of these findings in the radiographic interpretation reports were also examined. Of the 1,135 patients examined, 326 (28.7%) had several types of incidental findings. In particular, 169 (14.9%) of the 1,135 patients had nodules >5 mm in diameter, for which further careful examination is recommended in the JABTS guideline. The description rate for nodules >5 mm in diameter in the radiographic interpretation reports was 30.8% (52/169 patients), of whom 17.3% (9/52 patients) were referred to the endocrinology department for further careful examination. Incidental findings in the thyroid gland were relatively common on CT images of the oral and maxillofacial region. Oral radiologists tend to focus specifically on the oral and maxillofacial region during diagnosis on oral and maxillofacial CT images, but should pay the same careful attention to observe adjacent regions, such as the thyroid gland.