LHLilian R. Heil

Lilian R. Heil

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lilian R. Heil has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comet Fragment-Ion Indexing for Enhanced Peptide Sequencing

    by Christopher D. McGann, Erik J. Bergstrom, Vagisha Sharma, Lilian R. Heil, Qing Yu, Jimmy K. Eng, Devin K. Schweppe

    Fragment ion indexing has significantly improved the efficiency of proteomics database search tools. This work implements fragment ion indexing in Comet, a widely used, open-source search engine. We demonstrate that this enhancement maintains scoring and identification accuracy while substantially increasing peptide spectral matching speeds across multiple applications, including open modification searches, immunopeptidomics, and real-time searches. Comet-FI reduced search speeds by up to 94%, enabling the rapid analysis of complex data types like immunopeptidomes. Fragment-ion indexing enables Comet to keep pace with modern instrumentation and expanding applications in proteomics, reinforcing its utility in diverse proteomics workflows and its integration with a wide range of proteomics tools and platforms.


  • Hybrid Quadrupole Mass Filter–Radial Ejection Linear Ion Trap and Intelligent Data Acquisition Enable Highly Multiplex Targeted Proteomics

    by Philip M. Remes, Cristina C. Jacob, Lilian R. Heil, Nicholas Shulman, Brendan X. MacLean, Michael J. MacCoss

    Targeted mass spectrometry (MS) methods are powerful tools for the selective and sensitive analysis of peptides identified in global discovery experiments. Selected reaction monitoring (SRM) is the most widely accepted clinical MS method due to its reliability and performance. However, SRM and parallel reaction monitoring (PRM) are limited in throughput and are typically used for assays with around 100 targets or fewer. Here we introduce a new MS platform featuring a quadrupole mass filter, collision cell, and linear ion trap architecture, capable of targeting 5000-8000 peptides per hour. This high multiplexing capability is facilitated by acquisition rates of 70-100 Hz and real-time chromatogram alignment. We present a Skyline external software tool for building targeted methods based on data-independent acquisition chromatogram libraries or unscheduled analysis of heavy labeled standards. Our platform demonstrates ∼10× lower limits of quantitation (LOQs) than traditional SRM on a triple quadrupole instrument for highly multiplexed assays, due to parallel product ion accumulation. Finally, we explore how analytical figures of merit vary with method duration and the number of analytes, providing insights into optimizing assay performance.


  • Open Access

    Comet fragment-ion indexing for enhanced peptide sequencing

    by Christopher D. McGann, Erik J. Bergstrom, Vagisha Sharma, Lilian R. Heil, Qing Yu, Jimmy K. Eng, Devin K. Schweppe

    Fragment ion indexing has significantly improved the efficiency of proteomics database search tools. This work implements fragment ion indexing in Comet, a widely-used, open-source search engine. We demonstrate that this enhancement maintains scoring and identification accuracy while substantially increasing peptide spectral matching speeds across multiple applications, including open modification searches, immunopeptidomics, and real-time searches. Comet-FI reduced search speeds by up to 94%, enabling the rapid analysis of complex data types like immunopeptidomes. Fragment-ion indexing enables Comet to keep pace with modern instrumentation and expanding applications in proteomics, reinforcing its utility in diverse proteomics workflows and its integration with a wide range of proteomics tools and platforms.


  • Open Access

    Development of highly multiplex targeted proteomics assays in biofluids using the Stellar mass spectrometer

    by Deanna L Plubell, Philip M. Remes, Christine C. Wu, Cristina C. Jacob, Gennifer E. Merrihew, Chris Hsu, Nick Shulman, Brendan X. MacLean, Lilian Heil, Kathleen Poston, et al.

    The development of targeted assays that monitor biomedically relevant proteins is an important step in bridging discovery experiments to large scale clinical studies. Targeted assays are currently unable to scale to hundreds or thousands of targets. We demonstrate the generation of large-scale assays using a novel hybrid nominal mass instrument. The scale of these assays is achievable with the Stellar TM mass spectrometer through the accommodation of shifting retention times by real-time alignment, while being sensitive and fast enough to handle many concurrent targets. Assays were constructed using precursor information from gas-phase fractionated (GPF) data-independent acquisition (DIA). We demonstrate the ability to schedule methods from an orbitrap and linear ion trap acquired GPF DIA library and compare the quantification of a matrix-matched calibration curve from orbitrap DIA and linear ion trap parallel reaction monitoring (PRM). Two applications of these proposed workflows are shown with a cerebrospinal fluid (CSF) neurodegenerative disease protein PRM assay and with a Mag-Net enriched plasma extracellular vesicle (EV) protein survey PRM assay.


  • Open Access

    Hybrid Quadrupole Mass Filter – Radial Ejection Linear Ion Trap and Intelligent Data Acquisition Enable Highly Multiplex Targeted Proteomics

    by Philip M. Remes, Cristina C. Jacob, Lilian R. Heil, Nicholas Shulman, Brendan X. MacLean, Michael J. MacCoss

    Targeted mass spectrometry (MS) methods are powerful tools for selective and sensitive analysis of peptides identified by global discovery experiments. Selected reaction monitoring (SRM) is currently the most widely accepted MS method in the clinic, due to its reliability and analytical performance. However, due to limited throughput and the difficulty in setting up and analyzing large scale assays, SRM and parallel reaction monitoring (PRM) are typically used only for very refined assays of on the order of 100 targets or less. Here we introduce a new MS platform with a quadrupole mass filter, collision cell, linear ion trap architecture that has increased acquisition rates compared to the analogous hardware found in the Orbitrap™ Tribrid™ series instruments. The platform can target more analytes than existing SRM and PRM instruments – in the range of 5000 to 8000 peptides per hour. This capability for high multiplexing is enabled by acquisition rates of 70-100 Hz for peptide applications, and the incorporation of real-time chromatogram alignment that adjusts for retention time drift and enables narrow time scheduled acquisition windows. Finally, we describe a Skyline external software tool that implements the building of targeted methods based on data independent acquisition chromatogram libraries or unscheduled analysis of heavy labeled standards. We show that the platform delivers ~10x lower LOQs than traditional SRM analysis for a highly multiplex assay and also demonstrate how analytical figures of merit change while varying method duration with a constant number of analytes, or by keeping a constant time duration while varying the number of analytes.


  • Top Cited Papers
    Open Access

    Evaluating the Performance of the Astral Mass Analyzer for Quantitative Proteomics Using Data-Independent Acquisition

    by Lilian R. Heil, Eugen Damoc, Tabiwang N. Arrey, Anna Pashkova, Eduard Denisov, Johannes Petzoldt, Amelia C. Peterson, Chris Hsu, Brian C. Searle, Nicholas Shulman, et al.

    We evaluate the quantitative performance of the newly released Asymmetric Track Lossless (Astral) analyzer. Using data-independent acquisition, the Thermo Scientific Orbitrap Astral mass spectrometer quantifies 5 times more peptides per unit time than state-of-the-art Thermo Scientific Orbitrap mass spectrometers, which have long been the gold standard for high-resolution quantitative proteomics. Our results demonstrate that the Orbitrap Astral mass spectrometer can produce high-quality quantitative measurements across a wide dynamic range. We also use a newly developed extracellular vesicle enrichment protocol to reach new depths of coverage in the plasma proteome, quantifying over 5000 plasma proteins in a 60 min gradient with the Orbitrap Astral mass spectrometer.


  • Dynamic Data-Independent Acquisition Mass Spectrometry with Real-Time Retrospective Alignment

    by Lilian R. Heil, Philip M. Remes, Jesse D. Canterbury, Ping Yip, William D. Barshop, Christine C. Wu, Michael J. MacCoss

    Data-independent acquisition (DIA) mass spectrometry has grown in popularity in recent years, because of the reproducibility and quantitative rigor of a systematic tandem mass spectrometry (MS/MS) sampling method. However, traditional DIA methods may spend valuable instrument time acquiring MS/MS spectra with no usable information in them, affecting sensitivity and quantitative performance. We developed a DIA strategy that dynamically adjusts the MS/MS windows during the chromatographic separation. The method focuses MS/MS acquisition on the most relevant mass range at each point in time─increasing the quantitative sensitivity by increasing the time spent on each DIA window. We demonstrate an improved lower limit of quantification, on average, without sacrificing the number of peptides detected.


  • Open Access

    Dynamic Data Independent Acquisition Mass Spectrometry with Real-Time Retrospective Alignment

    by Lilian R Heil, Philip M Remes, Jesse D Canterbury, Ping Yip, William D Barshop, Christine C Wu, Michael J MacCoss

    We report a data independent acquisition (DIA) strategy that dynamically adjusts the tandem mass spectrometry (MS/MS) windows during the chromatographic separation. The method focuses MS/MS acquisition on the most relevant mass range at each point in time – improving the quantitative sensitivity by increasing the time spent on each DIA window. We demonstrate an improved lower limit of quantification, on average, without sacrificing the number of peptides detected.


  • Building Spectral Libraries from Narrow-Window Data-Independent Acquisition Mass Spectrometry Data

    by Lilian R. Heil, William E. Fondrie, Christopher D. McGann, Alexander J. Federation, William S. Noble, Michael J. MacCoss, Uri Keich

    Advances in library-based methods for peptide detection from data independent acquisition (DIA) mass spectrometry have made it possible to detect and quantify tens of thousands of peptides in a single mass spectrometry run. However, many of these methods rely on a comprehensive, high quality spectral library containing information about the expected retention time and fragmentation patterns of peptides in the sample. Empirical spectral libraries are often generated through data-dependent acquisition and may suffer from biases as a result. Spectral libraries can be generated in silico but these models are not trained to handle all possible post-translational modifications. Here, we propose a false discovery rate controlled spectrum-centric search workflow to generate spectral libraries directly from gas-phase fractionated DIA tandem mass spectrometry data. We demonstrate that this strategy is able to detect phosphorylated peptides and can be used to generate a spectral library for accurate peptide detection and quantitation in wide window DIA data. We compare the results of this search workflow to other library-free approaches and demonstrate that our search is competitive in terms of accuracy and sensitivity. These results demonstrate that the proposed workflow has the capacity to generate spectral libraries while avoiding the limitations of other methods.


  • Open Access

    Does Data-Independent Acquisition Data Contain Hidden Gems? A Case Study Related to Alzheimer’s Disease

    by Evan E. Hubbard, Lilian R. Heil, Gennifer E. Merrihew, Jasmeer P. Chhatwal, Martin R. Farlow, Catriona A. McLean, Bernardino Ghetti, Kathy L. Newell, Matthew P. Frosch, Randall J. Bateman, et al.

    One of the potential benefits of using data-independent acquisition (DIA) proteomics protocols is that information not originally targeted by the study may be present and discovered by subsequent analysis. Herein, we reanalyzed DIA data originally recorded for global proteomic analysis to look for isomerized peptides, which occur as a result of spontaneous chemical modifications to long-lived proteins. Examination of a large set of human brain samples revealed a striking relationship between Alzheimer’s disease (AD) status and isomerization of aspartic acid in a peptide from tau. Relative to controls, a surprising increase in isomer abundance was found in both autosomal dominant and sporadic AD samples. To explore potential mechanisms that might account for these observations, quantitative analysis of proteins related to isomerization repair and autophagy was performed. Differences consistent with reduced autophagic flux in AD-related samples relative to controls were found for numerous proteins, including most notably p62, a recognized indicator of autophagic inhibition. These results suggest, but do not conclusively demonstrate, that lower autophagic flux may be strongly associated with loss of function in AD brains. This study illustrates that DIA data may contain unforeseen results of interest and may be particularly useful for pilot studies investigating new research directions. In this case, a promising target for future investigations into the therapy and prevention of AD has been identified.