Rachit Mehra
Rachit Mehra has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Faruk Kazi
10 shared publicationsN. M. Singh
Centre of Excellence in Complex and Nonlinear Dynamical Systems, Veermata Jijabai Technological Institute (VJTI), Mumbai, India
4 shared publicationsN.M. Singh
3 shared publicationsNavdeep Singh
Department of Electrical Engineering, VJTI, Mumbai
2 shared publicationsSumeet Satpute
Centre of Excellence in Complex and Nonlinear Dynamical Systems, Veermata Jijabai Technological Institute (VJTI), Mumbai, India
2 shared publicationsVenkatesh Chinde
2 shared publications
Latest Publications
- 1 December 2017
- Published by Elsevier in Automatica
- Vol. 86, 98-103
Control of a class of underactuated mechanical systems obviating matching conditions
- 1 December 2017
- Published by Elsevier in Automatica
- Vol. 86, 98-103
Control of a class of underactuated mechanical systems obviating matching conditions
- 28 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 7 (4) , 1970-1978
Impact of Topology on the Propagation of Cascading Failure in Power Grid
In the past two decades the frequent occurrences of large scale blackouts and catastrophic events has reduced the reliability of power grid to a great extent. A thorough analysis of the propagation of failures, in terms of line outages, combined with the topological characteristics of the grid aids, has been done to take corrective actions to save the system from complete collapse. It also helps to investigate the progress and understand the nature and intensity of blackouts. This motivates to establish the relationship between the network topological characteristics and cascading failure in the power grid. In this paper, the basic topological characteristics of the power network are studied in detail and the average propagation of failure under varying topological conditions is calculated as a branching process parameter. The variation in the mean propagation is studied in detail using a number of test bed networks with the alternate realistic networks derived from the standard IEEE networks imitating the real network conditions. The results confirm a qualitative agreement between the variations in topological parameter and the failure propagation rate in the cascading regime. Based on the analysis mentioned above, data clearly shows that the average failure propagation factor varies linearly with the variations in the statistical metrics.
- 28 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 7 (4) , 1970-1978
Impact of Topology on the Propagation of Cascading Failure in Power Grid
In the past two decades the frequent occurrences of large scale blackouts and catastrophic events has reduced the reliability of power grid to a great extent. A thorough analysis of the propagation of failures, in terms of line outages, combined with the topological characteristics of the grid aids, has been done to take corrective actions to save the system from complete collapse. It also helps to investigate the progress and understand the nature and intensity of blackouts. This motivates to establish the relationship between the network topological characteristics and cascading failure in the power grid. In this paper, the basic topological characteristics of the power network are studied in detail and the average propagation of failure under varying topological conditions is calculated as a branching process parameter. The variation in the mean propagation is studied in detail using a number of test bed networks with the alternate realistic networks derived from the standard IEEE networks imitating the real network conditions. The results confirm a qualitative agreement between the variations in topological parameter and the failure propagation rate in the cascading regime. Based on the analysis mentioned above, data clearly shows that the average failure propagation factor varies linearly with the variations in the statistical metrics.
- 30 September 2015
- Published by Praise Worthy Prize in International Review of Automatic Control (IREACO)
- Vol. 8 (5) , 362
Energy Shaping for Tracking Control of 4-DOF Crane
In this paper the nonlinear tracking control methodology is proposed for 4–DOF (degree of freedom) overhead crane system using energy shaping. The 4–DOF underactuated overhead crane system has an extra DOF compared with the popular 3–DOF variant. The 4-DOF crane modeling represents strong state coupling and more complicated system dynamics which makes it challenging control problem. The control methodology begins with the first step of decoupling the crane dynamics into two subsystems using collocated partial feedback linearization. The passivating outputs of the modified subsystems are identified which are further utilized for energy shaping to obtain the nonlinear state feedback control law which effectively achieves the objective of trajectory tracking with fast elimination of payload swings. The energy shaping procedure obviates the need for solving PDEs to derive the control law. The trajectory tracking control law represents generalization of the position regulation problem. The simulation results are presented to validate the control law and superior performance is demonstrated over the existing control methodologies. Copyright © 2015 Praise Worthy Prize - All rights reserved.
- 30 September 2015
- Published by Praise Worthy Prize in International Review of Automatic Control (IREACO)
- Vol. 8 (5) , 362
Energy Shaping for Tracking Control of 4-DOF Crane
In this paper the nonlinear tracking control methodology is proposed for 4–DOF (degree of freedom) overhead crane system using energy shaping. The 4–DOF underactuated overhead crane system has an extra DOF compared with the popular 3–DOF variant. The 4-DOF crane modeling represents strong state coupling and more complicated system dynamics which makes it challenging control problem. The control methodology begins with the first step of decoupling the crane dynamics into two subsystems using collocated partial feedback linearization. The passivating outputs of the modified subsystems are identified which are further utilized for energy shaping to obtain the nonlinear state feedback control law which effectively achieves the objective of trajectory tracking with fast elimination of payload swings. The energy shaping procedure obviates the need for solving PDEs to derive the control law. The trajectory tracking control law represents generalization of the position regulation problem. The simulation results are presented to validate the control law and superior performance is demonstrated over the existing control methodologies. Copyright © 2015 Praise Worthy Prize - All rights reserved.
- 17 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. 61 (4) , 1051-1056
Shaping the Energy of Mechanical Systems Without Solving Partial Differential Equations
Control of underactuated mechanical systems via energy shaping is a well-established, robust design technique. Unfortunately, its application is often stymied by the need to solve partial differential equations (PDEs). In this technical note a new, fully constructive, procedure to shape the energy for a class of mechanical systems that obviates the solution of PDEs is proposed. The control law consists of a first stage of partial feedback linearization followed by a simple proportional plus integral controller acting on two new passive outputs. The class of systems for which the procedure is applicable is identified imposing some (directly verifiable) conditions on the systems inertia matrix and its potential energy function. It is shown that these conditions are satisfied by three benchmark examples.
- 17 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. 61 (4) , 1051-1056
Shaping the Energy of Mechanical Systems Without Solving Partial Differential Equations
Control of underactuated mechanical systems via energy shaping is a well-established, robust design technique. Unfortunately, its application is often stymied by the need to solve partial differential equations (PDEs). In this technical note a new, fully constructive, procedure to shape the energy for a class of mechanical systems that obviates the solution of PDEs is proposed. The control law consists of a first stage of partial feedback linearization followed by a simple proportional plus integral controller acting on two new passive outputs. The class of systems for which the procedure is applicable is identified imposing some (directly verifiable) conditions on the systems inertia matrix and its potential energy function. It is shown that these conditions are satisfied by three benchmark examples.
- 1 January 2014
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 47 (3) , 5479-5484
Feedback linearization of Single-Input and Multi-Input Control System
- 1 January 2014
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 47 (3) , 5479-5484
Feedback linearization of Single-Input and Multi-Input Control System
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 374-377
Differentiation of faults from power swings and detection of high impedance faults by distance relays
For maintaining security and reliable operation of distance relays power swing blocking is necessary to prevent maloperation during power swings and high impedance faults detection is necessary for operation of distance relays, since distance relays may treat high impedance faults as load since the fault will be out of reach of the relay. This paper proposes an algorithm for differentiation of faults from power swing and high impedance fault detection by distance relay simultaneously by a single algorithm, based on extracting current waveform components using Prony method. The merit of this method is demonstrated by simulating different high impedance faults and also during power swing conditions using the ATP version of the EMTP.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 374-377
Differentiation of faults from power swings and detection of high impedance faults by distance relays
For maintaining security and reliable operation of distance relays power swing blocking is necessary to prevent maloperation during power swings and high impedance faults detection is necessary for operation of distance relays, since distance relays may treat high impedance faults as load since the fault will be out of reach of the relay. This paper proposes an algorithm for differentiation of faults from power swing and high impedance fault detection by distance relay simultaneously by a single algorithm, based on extracting current waveform components using Prony method. The merit of this method is demonstrated by simulating different high impedance faults and also during power swing conditions using the ATP version of the EMTP.
- 1 August 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 817-821
Modes preserving wavelet based multi-scale PCA algorithm for compression of smart grid data
In this paper, wavelet based multiscale PCA algorithm is proposed for effective compression of smart grid data under normal as well as fault conditions. The signal decomposition is done using wavelet transform, followed by the de-correlation using PCA, to achieve maximum compression, while simultaneously preserving the dominant modes of the signal and bad data rejection. The optimum decomposition scale of wavelet transform is selected based on the energy of wavelet coefficients in each scale. The proposed algorithm employing multiscale PCA computes the principal components of the wavelet coefficients at each scale, followed by combining the results at relevant scales. The wavelet coefficients of a particular scale corresponding to the dominant eigen values are retained for signal compression. The dominant modes in the signal are sorted based on their energy content. This overcomes the drawback of false detection of modes and lower accuracy of estimation which arises when systems of higher order are used. Prony analysis is performed to check ability of the compression strategy to preserve the modal information. The phasor data are simulated under fault conditions in the IEEE 30-bus system. The results from Prony analysis indicate that multiscale PCA effectively compresses the disturbance signals while preserving the model information of the signal.
- 1 August 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 817-821
Modes preserving wavelet based multi-scale PCA algorithm for compression of smart grid data
In this paper, wavelet based multiscale PCA algorithm is proposed for effective compression of smart grid data under normal as well as fault conditions. The signal decomposition is done using wavelet transform, followed by the de-correlation using PCA, to achieve maximum compression, while simultaneously preserving the dominant modes of the signal and bad data rejection. The optimum decomposition scale of wavelet transform is selected based on the energy of wavelet coefficients in each scale. The proposed algorithm employing multiscale PCA computes the principal components of the wavelet coefficients at each scale, followed by combining the results at relevant scales. The wavelet coefficients of a particular scale corresponding to the dominant eigen values are retained for signal compression. The dominant modes in the signal are sorted based on their energy content. This overcomes the drawback of false detection of modes and lower accuracy of estimation which arises when systems of higher order are used. Prony analysis is performed to check ability of the compression strategy to preserve the modal information. The phasor data are simulated under fault conditions in the IEEE 30-bus system. The results from Prony analysis indicate that multiscale PCA effectively compresses the disturbance signals while preserving the model information of the signal.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 528-533
Blended algorithm for feedback linearization of single input control system
A new algorithm is proposed for computing locally the linearizing output of a single input nonlinear affine system. The algorithm relies on Goursat normal form, which is suitably modified, to obtain the successive integrations of one dimensional distributions of control system. The algorithm takes ideas from both vector field approach of feedback linearization and exterior differential system tools, hence the name Blended Algorithm is proposed. The proposed algorithm leads to a simple method of finding a linearizing output and has many advantages over the existing methods. The algorithm exhibits reduced computational complexity and can be extended to multi input system and partial linearizable system because of the underlying tower like structure.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 528-533
Blended algorithm for feedback linearization of single input control system
A new algorithm is proposed for computing locally the linearizing output of a single input nonlinear affine system. The algorithm relies on Goursat normal form, which is suitably modified, to obtain the successive integrations of one dimensional distributions of control system. The algorithm takes ideas from both vector field approach of feedback linearization and exterior differential system tools, hence the name Blended Algorithm is proposed. The proposed algorithm leads to a simple method of finding a linearizing output and has many advantages over the existing methods. The algorithm exhibits reduced computational complexity and can be extended to multi input system and partial linearizable system because of the underlying tower like structure.
- 1 January 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis of PCA based compression and denoising of smart grid data under normal and fault conditions
This paper describes application of principal component analysis (PCA) based data compression approaches for smart grid (SG) data storage. PCA methods are applied and compared for steady state operations and various system fault conditions. For signals with Gaussian noise data, a variant of PCA, labelled Iterative PCA (IPCA) is applied to simulated phasor data. The phasor data is simulated for IEEE New England 30-bus system using ETAP software. The simulated data is then stored using the PCA and IPCA, which exploit the sparsity and collinearity among variables in the simulated data. The results indicate that proposed methods compress both the steady state and transient signals effectively while simultaneously removing the Gaussian noise contained in the signals.
- 1 January 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis of PCA based compression and denoising of smart grid data under normal and fault conditions
This paper describes application of principal component analysis (PCA) based data compression approaches for smart grid (SG) data storage. PCA methods are applied and compared for steady state operations and various system fault conditions. For signals with Gaussian noise data, a variant of PCA, labelled Iterative PCA (IPCA) is applied to simulated phasor data. The phasor data is simulated for IEEE New England 30-bus system using ETAP software. The simulated data is then stored using the PCA and IPCA, which exploit the sparsity and collinearity among variables in the simulated data. The results indicate that proposed methods compress both the steady state and transient signals effectively while simultaneously removing the Gaussian noise contained in the signals.
- 1 January 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 28, 1-5
Passivity based controller for underactuated PVTOL system
This paper proposes a control law for Planar Vertical Take Off and Landing (PVTOL) system based on feedback passivation method. The PVTOL system is a benchmark control system problem which embodies in itself many control theoretic challenges due to its nonlinear and underactuaed dynamics. Trajectory tracking of PVTOL system with its roll angle control is investigated in the paper. Stability of the PVTOL roll angle is ensured by the property that the equilibrium point of a passive system always remains stable. The equivalence of PVTOL dynamics with the pendulum dynamics is exploited to design a simple passivity based feedback controller. The proposed framework interprets PVTOL dynamics as pendulum dynamics and integrator systems whose interconnection can be made passive under the action of the designed control law. The forces exerted by the actuators can be synthesized from the control law.
- 1 January 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 28, 1-5
Passivity based controller for underactuated PVTOL system
This paper proposes a control law for Planar Vertical Take Off and Landing (PVTOL) system based on feedback passivation method. The PVTOL system is a benchmark control system problem which embodies in itself many control theoretic challenges due to its nonlinear and underactuaed dynamics. Trajectory tracking of PVTOL system with its roll angle control is investigated in the paper. Stability of the PVTOL roll angle is ensured by the property that the equilibrium point of a passive system always remains stable. The equivalence of PVTOL dynamics with the pendulum dynamics is exploited to design a simple passivity based feedback controller. The proposed framework interprets PVTOL dynamics as pendulum dynamics and integrator systems whose interconnection can be made passive under the action of the designed control law. The forces exerted by the actuators can be synthesized from the control law.