MSMargaret Sietsema

Margaret Sietsema

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Margaret Sietsema has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Developing Regulatory Framework and Performance Criteria for Children’s Respiratory Protective Devices: White Paper

    by Jonathan Szalajda, Jessica Tredinnick-Higgins, Margaret Sietsema, Claire J. Horwell, Stephanie Holm, Stephanie Lynch, Simon Smith, Caroline Johnson

    The unique physiological and developmental characteristics of children make them very susceptible to inhalation hazards. Almost all respiratory protective devices (RPDs) are designed for adult occupational use and rarely address the needs of pediatric populations. Studies in National Academies of Sciences, Engineering, and Medicine (NASEM) proceedings indicate that, while respirators can reduce children’s exposures, they are generally less effective than when designed for, and properly used by, adults (NASEM, 2022). Challenges such as lower inspiratory and expiratory pressures, discomfort due to filtration (breathing) resistance, and cognitive limitations in younger children make respirator usage more complex. In addition, the facial dimensions vary greatly. These factors highlight the necessity for specialized design frameworks that ensure safety, usability, and accessibility (NASEM, 2022). The International Society for Respiratory Protection (ISRP) has been a collaborating partner with the FACE-UP (Factors Affecting Childhood Exposures to Urban Particulates) project, which aimed to establish the efficacy of children’s use of respiratory protection to reduce their exposure to particulate air pollution. As part of this effort, ISRP and FACE-UP conducted two workshops in 2024 to give an overview of existing information and identify knowledge gaps surrounding respiratory protection for children. The intent of the workshops was to address priorities for the development of regulatory frameworks, including recommendations for design and performance criteria, the design of a global consensus standard, manufacturing and distribution considerations, product registration requirements, selection and use guidance, education and training, ethical considerations, and recommended next steps. This White Paper lays out these recommendations. A worldwide standard for pediatric respirators should be established under the leadership of a global consensus standard development organization, such as the International Organization for Standardization (ISO) or ASTM International, ensuring adaptability to diverse populations and regional needs. This requires standardized testing protocols that incorporate child-specific physiological and ergonomic considerations; regional flexibility within global standards to account for variable demographics and environmental exposures, and alignment with existing national regulatory frameworks to streamline certification and adoption. Developing pediatric RPDs necessitates a nuanced approach which integrates filtration, breathability, fit, comfort, and accessibility. By leveraging insights from recent research and establishing age-appropriate performance standards, manufacturers can create effective solutions tailored to children’s respiratory protection needs. Additionally, comprehensive regulatory frameworks should be developed, which include guidance for families on when, where, and how respirators should be used by children, including references to the worldwide consensus standard as part of clear selection guidance. Continued interdisciplinary collaboration will refine these guidelines and enhance protection for pediatric populations amid evolving health and safety challenges.


  • Open Access

    Provider experiences with daily use of elastomeric half-mask respirators in health care

    by Morgan Lane, Lisa Pompeii, Janelle Rios, Elisa Benavides, Marie Kasbaum, Scott Patlovich, Luis Ostrosky-Zeichner, Adam Hornbeck, Caitlin McClain, Rohan Fernando, et al.


  • Open Access

    Simulated workplace protection factor study of a quarter-facepiece elastomeric respirator

    by Margaret Sietsema, Hamed Hamza, Lisa M. Brosseau

    The assigned protection factor (APF) for quarter facepiece respirators is currently 5, based on fit test data from the 1970s with models no longer commercially available. The goal of this project was to evaluate the respirator fit capability of a NIOSH-approved N95 quarter facepiece elastomeric respirator with a gel-based facial seal design (Envo® Mask by Sleepnet Corporation). Human subjects were recruited from healthcare and the general population to satisfy a 25-member NIOSH bivariate panel. Subjects were fit tested with a fast fit protocol using a TSI Portacount Model 8038 in the N95 mode. Second-by-second measures of fit were then collected while subjects performed a 30-min series of simulated healthcare activities. Subjects completed a short comfort questionnaire. The median (5th, 95th percentile) fit factor was 188 (48, 201). Simulated workplace protection factors (SWPFs) had a median (5th, 95th percentile) of 181 (94, 199) (data truncated at 200) and 570 (153, 1508) (non-truncated data). Subjects ranked inhalation and exhalation as “easy” with average scores of 5.0/6.0 and 5.2/6.0, respectively. The facepiece was ranked between slightly comfortable and comfortable (4.8/6.0) and the harness as comfortable (5.0/6.0). Most users agreed (5.2/6.0) that the mask was stable on their face. The 5th percentile SWPF of 95 supports an APF of at least 10 for this quarter facepiece elastomeric respirator, similar to the APF for half facepiece respirators. This study supports increasing the APF for quarter facepiece respirators, a class that has been largely ignored by manufacturers for the past 40 years. A lightweight, low profile, reusable quarter facepiece respirator is an effective option for healthcare and other worker protection during pandemic and similar situations.


  • Top Cited Papers
    Open Access

    REDECA: A Novel Framework to Review Artificial Intelligence and Its Applications in Occupational Safety and Health

    by Maryam Pishgar, Salah Fuad Issa, Margaret Sietsema, Preethi Pratap, Houshang Darabi

    Introduction: The field of artificial intelligence (AI) is rapidly expanding, with many applications seen routinely in health care, industry, and education, and increasingly in workplaces. Although there is growing evidence of applications of AI in workplaces across all industries to simplify and/or automate tasks there is a limited understanding of the role that AI contributes in addressing occupational safety and health (OSH) concerns. Methods: This paper introduces a new framework called Risk Evolution, Detection, Evaluation, and Control of Accidents (REDECA) that highlights the role that AI plays in the anticipation and control of exposure risks in a worker’s immediate environment. Two hundred and sixty AI papers across five sectors (oil and gas, mining, transportation, construction, and agriculture) were reviewed using the REDECA framework to highlight current applications and gaps in OSH and AI fields. Results: The REDECA framework highlighted the unique attributes and research focus of each of the five industrial sectors. The majority of evidence of AI in OSH research within the oil/gas and transportation sectors focused on the development of sensors to detect hazardous situations. In construction the focus was on the use of sensors to detect incidents. The research in the agriculture sector focused on sensors and actuators that removed workers from hazardous conditions. Application of the REDECA framework highlighted AI/OSH strengths and opportunities in various industries and potential areas for collaboration. Conclusions: As AI applications across industries continue to increase, further exploration of the benefits and challenges of AI applications in OSH is needed to optimally protect worker health, safety and well-being.


  • A Control Banding Framework for Protecting the US Workforce from Aerosol Transmissible Infectious Disease Outbreaks with High Public Health Consequences

    by Margaret Sietsema, Lew Radonovich, Frank J. Hearl, Edward M. Fisher, Lisa M. Brosseau, Ronald E. Shaffer, Lisa M. Koonin

    Recent high-profile infectious disease outbreaks illustrate the importance of selecting appropriate control measures to protect a wider range of employees, other than those in healthcare settings. In such settings, where routine exposure risks are often high, control measures may be more available, routinely implemented, and studied for effectiveness. In the absence of evidence-based guidelines or established best practices for selecting appropriate control measures, employers may unduly rely on personal protective equipment (PPE) because of its wide availability and pervasiveness as a control measure, circumventing other effective options for protection. Control banding is one approach that may be used to assign job tasks into risk categories and prioritize the application of controls. This article proposes an initial control banding framework for workers at all levels of risk and incorporates a range of control options, including PPE. Using the National Institutes of Health (NIH) risk groups as a surrogate for toxicity and combining the exposure duration with the exposure likelihood, we can generate the risk of a job task to the worker.


  • Are quantitative fit factors predictive of respirator fit during simulated healthcare activities?

    by Margaret Sietsema, Lisa M. Brosseau

    An annual OSHA fit test is required for all U.S. employees required to wear a respirator during work, but there are limited data demonstrating a link between fit test results and respirator fit during work. The goal of this research is to determine if the fit factor (FF) achieved during an abbreviated ambient aerosol condensation particle counter (CPC) quantitative fit test is predictive of fit achieved during a simulated workplace protection factor (SWPF) scenario that includes realistic healthcare activities. Fifteen subjects (7 male; 8 female) were recruited for a range of facial sizes. Each subject donned an N95 filtering facepiece respirator and performed a single 29-min routine consisting of initial and final 2.5 min fast fit tests (five 30-sec exercises: normal breathing, head side to side, head up and down, talking, and bending over) and three repetitions of three 6-min simulated healthcare activities (CPR, ultrasound, and making a hospital bed). Two CPC instruments simultaneously collected second-by-second measures of particle concentration inside and outside of the respirator facepiece. FFs or SWPFs were calculated by dividing outside by inside facepiece concentrations. Overall FFs and SWPFs were highly correlated. Each exercise FF was highly correlated with the overall SWPF. Normal breathing, head up and down, and talking were most predictive of overall SWPF. Normal breathing and talking together were predictive of each of the three simulated healthcare activities. For CPR and bed making activities, head movement exercises were also found to be predictive. A quantitative fit test using a small set of exercises is highly predictive of an individual’s fit during simulated work activities. Some exercises (e.g. talking and head movements) are predictive of fit during simulated workplace activities. Limitations include only one respirator model, a small subject pool not representative of the full range of face sizes. This paper uses an innovative second-by-second assessment method that collects information about in- and outside-facepiece concentrations throughout the test period.


  • Impact of time and assisted donning on respirator fit

    by Brian Rembialkowski, Margaret Sietsema, Lisa Brosseau

    The goal of this study was to examine the impact of assistance with donning and time on quantitative fit factors (FF) and pass rates for subjects wearing an N95 filtering facepiece respirator (FFR) and a non-certified adhesive mask. Fit factors were measured using two side-by-side TSI Portacount instruments sampling second-by-second simultaneous inside- and outside-facepiece concentrations. Naïve subjects made two visits at least one week apart. At each visit subjects first donned either the respirator or adhesive mask without assistance and performed a five-exercise fast fit test. They then donned a new respirator or mask with assistance in proper donning (e.g., proper forming of the nosepiece, strap placement, etc.) and performed a second five-exercise fast fit test. The same sequence of unassisted and assisted donning was then repeated with the other facepiece. Fifteen subjects participated in the study; time between visits ranged from 7–29 days (average 12 days). On visit 1 the respirator FFs were significantly higher (GM = 88) than for the adhesive mask (GM = 14); with assistance these FFs showed significant improvements to 116 and 124, respectively. At visit 1 almost half of subjects donning the respirator without assistance achieved a passing FF of 100 or greater, while only one-fifth of subjects were able to pass the fit test wearing an adhesive mask without assistance. Pass rates improved for both groups with assistance, but more so for the adhesive mask wearers. On visit 2 the pass rates for both groups had decreased, with the adhesive mask group showing a greater decrease. With assistance, pass rates improved for both groups, but again more so for those wearing the adhesive mask. Results suggest that wearers would benefit from assistance and re-training every time they don a respirator, even if the time between donnings is as short as one or two weeks.


  • Open Access

    Evaluating Simulated Workplace Protection Factors for a First Responder Low-Level Protective Ensemble

    by Margaret Sietsema, Paul Bodurtha, Lisa M Brosseau

    First responders are required to wear multiple layers of personal protective equipment while performing a range of physiologically demanding tasks for long periods of time. They are often required to wear high levels of respiratory protection, which can adversely impact their ability to work safely. The goal of this study was to evaluate the respiratory protective performance of a nominally lower level protective system in the course of performing typical first responder activities, which included an N95 filtering facepiece respirator in combination with a disposable hooded suit and latex gloves. Methods: Eleven subjects (10 male; 1 female) were recruited for a range of facial sizes. Each subject donned an N95 filtering facepiece respirator following the Canadian fit test protocol. The subject then donned the hood, entered a test chamber and performed a 31-min exercise protocol. Using two Portacount instruments, one-second real-time measurements of particulate concentration were simultaneously performed inside and outside the respirator facepiece. Subjects exited the chamber, removed the hood and completed a final quantitative fit test. Results: While limited by the small number of subjects and few small faces, we were able to show that N95 filtering facepiece respirators can provide a high degree of protection (simulated workplace protection factors ranging from 100-1000). We found no consistent relationship between initial and final fit factors. Final fit factors and SWPF were strongly correlated. Conclusion: The two-instrument method combined with a challenging exercise protocol can elucidate several important respirator performance factors, including most challenging work tasks, effects of sweating and higher metabolic output, and interactions from other personal protective equipment.

  • Comparing Written Programs and Self-Reported Respiratory Protection Practices in Acute Care Hospitals

    by Margaret Sietsema, Lorraine M. Conroy, Lisa M. Brosseau

    Conclusions: Written respiratory protection programs in the study sites did not provide the level of detail required by the Occupational Safety and Health Administration. Interview responses representing hospital practices surrounding respiratory protection indicated that hospitals were aware of and following regulatory guidelines.


  • Evaluation of Minnesota and Illinois Hospital Respiratory Protection Programs and Health Care Worker Respirator Use

    by Lisa M. Brosseau, Lorraine M. Conroy, Margaret Sietsema, Kari Cline, Kara Durski

    The objective of this study was to assess respiratory protection programs for aerosol-transmissible diseases in acute care hospitals for conformance with regulatory requirements and public health guidelines. Twenty-eight representative hospitals were selected by size, location, and ownership in Minnesota and Illinois. Interviews were conducted with 363 health care workers and 171 managers from high-risk departments. Written programs from each hospital were reviewed for required elements. Seventy-seven health care workers were observed donning and doffing a FFR. The most serious deficiency in many written programs was failure to identify a program administrator. Most written programs lacked adequate details about medical evaluation, fit-testing, and training and did not include a comprehensive risk assessment for aerosol transmissible diseases; tuberculosis was often the only pathogen addressed. Employees with the highest probability of tuberculosis exposure were most likely to pick a respirator for close contact, but higher levels of respiratory protection were rarely selected for aerosol-generating procedures. Surgical masks were most commonly selected for close contact with droplet disease- or influenza-infected patients; better protection (e.g., respirator) was rarely selected for higher-risk exposures. Most of the observed health care workers had access to a NIOSH-certified N95 FFR, properly positioned the facepiece, and formed the nose clip. The most frequent deficiencies were failure to correctly place straps, perform a user seal check, and remove the respirator using straps.