Md. Atikur Rahman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Md. Atikur Rahman has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Abdullah Al Zubaer
Department of Computer Science and Engineering, Pirojpur Science and Technology University, Pirojpur 8500, Bangladesh
1 shared publication - Afsana Mim
Department of Computer Science and Engineering, University of Global Village, Barishal 8200, Bangladesh
1 shared publication - Jahirul Islam Babar
Department of Computer Science and Engineering, Comilla University, Cumilla 3506, Bangladesh
1 shared publication - Kazi Md. Rokibul Alam
Department of Computer Science and Engineering, Khulna University of Engineering and Technology, Khulna 9203, Bangladesh
1 shared publication - Mahmudul Hasan
Comilla University
1 shared publication - Md. Anwar Hossain Rantu
Department of Computer Science and Engineering, Comilla University, Cumilla 3506, Bangladesh
1 shared publication
Latest Publications
- Open Access
- 24 November 2026
- Published by MDPI AG in BioMedInformatics
- Vol. 6 (6) , 117
NeuroScan: A Leakage-Audited Unified Model for Stroke Slice Classification on Multi-Source CT and Diffusion MRI with a Web–Android Prototype
Distinguishing ischemic from hemorrhagic stroke guides treatment, yet many classifiers rely on single-modality or single-source data and report leakage controls inconsistently. In this internal feasibility study, the NeuroScan model classified computed tomography (CT) slices as normal, ischemic or hemorrhagic and diffusion magnetic resonance imaging (MRI) slices as normal or ischemic, because the MRI sources did not include hemorrhages. Seven leakage-audited public sources (109,443 slices, 85,872 used for training) were partitioned by patient where identifiers existed. The final ConvNeXt-Tiny model, with 224 × 224-pixel neighboring-slice or paired-sequence input, was evaluated once on internally reused evaluation cohorts, held out of training but used in earlier development, so the results are optimistic internal estimates, not independent or external validation. Under the class-weighted rule, it reached 89.2% accuracy (95% CI 88.2–90.1) and 87.2% macro-F1 on 8930 pooled internal test slices, and 88.5% and 86.8% under the prototype’s plain argmax; areas under the receiver operating characteristic curve were 0.986 (hemorrhage on CT) and 0.963 (ischemia). Joint training gave no discrimination advantage over matched single-modality models. At least one slice received the patient’s lesion class in 94.7% of lesion-positive patients; without healthy controls, patient-level specificity is unknown. During development, adding within-source lesion-free slices raised Core-Penumbra Acute Ischemic Stroke Dataset (CPAISD) accuracy from 43.5% to 81.4%. Across five seeds, accuracy varied little (SD 0.3 points), but CPAISD ischemic recall ranged from 54.2% to 78.6% (final model highest). Gradient-weighted class activation maps did not reliably localize lesions. A web–Android research prototype demonstrates inference; external validation is required before clinical use.
- 24 November 2026
- Published by MDPI AG in BioMedInformatics
- Vol. 6 (6) , 117
Open AccessNeuroScan: A Leakage-Audited Unified Model for Stroke Slice Classification on Multi-Source CT and Diffusion MRI with a Web–Android Prototype
Distinguishing ischemic from hemorrhagic stroke guides treatment, yet many classifiers rely on single-modality or single-source data and report leakage controls inconsistently. In this internal feasibility study, the NeuroScan model classified computed tomography (CT) slices as normal, ischemic or hemorrhagic and diffusion magnetic resonance imaging (MRI) slices as normal or ischemic, because the MRI sources did not include hemorrhages. Seven leakage-audited public sources (109,443 slices, 85,872 used for training) were partitioned by patient where identifiers existed. The final ConvNeXt-Tiny model, with 224 × 224-pixel neighboring-slice or paired-sequence input, was evaluated once on internally reused evaluation cohorts, held out of training but used in earlier development, so the results are optimistic internal estimates, not independent or external validation. Under the class-weighted rule, it reached 89.2% accuracy (95% CI 88.2–90.1) and 87.2% macro-F1 on 8930 pooled internal test slices, and 88.5% and 86.8% under the prototype’s plain argmax; areas under the receiver operating characteristic curve were 0.986 (hemorrhage on CT) and 0.963 (ischemia). Joint training gave no discrimination advantage over matched single-modality models. At least one slice received the patient’s lesion class in 94.7% of lesion-positive patients; without healthy controls, patient-level specificity is unknown. During development, adding within-source lesion-free slices raised Core-Penumbra Acute Ischemic Stroke Dataset (CPAISD) accuracy from 43.5% to 81.4%. Across five seeds, accuracy varied little (SD 0.3 points), but CPAISD ischemic recall ranged from 54.2% to 78.6% (final model highest). Gradient-weighted class activation maps did not reliably localize lesions. A web–Android research prototype demonstrates inference; external validation is required before clinical use.
- 11 June 2023
- Published by Springer Nature
- p. 524-538
A Smartphone Based Real-Time Object Recognition System for Visually Impaired People
- 11 June 2023
- Published by Springer Nature
- p. 524-538
A Smartphone Based Real-Time Object Recognition System for Visually Impaired People