Andrea Verdicchio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andrea Verdicchio has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Herve Caron
French National Railway Company (SNCF), 93210 La Plaine St Denis, France
2 shared publications- Philippe Ladoux
LAPLACE Laboratory Université de Toulouse Toulouse France
2 shared publications Christian Courtois
Electrical Traction department, Engineering and Projects Division, French National Railways (SNCF), Saint Denis 93575, France
1 shared publicationDidier Flumian
Laboratoire Plasma et Conversion d’Energie (LAPLACE), ENSEEIHT, INPT, 31071 Toulouse, France
1 shared publicationJean-Marc Blaquiere
Laboratoire Plasma et Conversion d’Energie (LAPLACE), ENSEEIHT, INPT, 31071 Toulouse, France
1 shared publication- Joseph Fabre
Société de Construction des Lignes Électriques-Systèmes pour Ferroviaire et Énergie (SCLE-SFE), 31204 Toulouse, France
1 shared publication
Latest Publications
- 28 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 7 (2) , 854-869
Characterization and Implementation of Resonant Isolated DC/DC Converters for Future MVdc Railway Electrification Systems
Today, in Electric Railways, the old DC supply systems are reaching their limits. To improve their efficiency and increase railroad traffic, a new DC Electrification has recently been proposed at 9-kV. It is now necessary to prepare the migration of infrastructure and rolling stock, using Power-Electronic-Transformers (PETs), for adaptation to this voltage level. For this application, high efficiency and reduced volume are essential. This paper clearly demonstrates that it is now possible to achieve compact, high-power, isolated DC-DC converters using 3.3-kV SiC-MOSFET power modules with high efficiency. After a preliminary study based on simulations, the paper focuses on characterization and implementation of elementary isolated DC-DC converters. The proposed topology is a series-resonant converter rated for a nominal power of 300-kW at 1.8-kV. First, laboratory testing using an “opposition-method” is used to evaluate the elementary converters up to their nominal power using both electrical and thermal measurements to accurately determine losses and efficiency. At the nominal output power, an efficiency of 98.93% is obtained. This is quite remarkable for an isolated DC-DC converter operating under 1.8-kV with a switching frequency of 15-kHz. Finally, two elementary isolated DC/DC converters are associated in ISOP configuration (Input Seriesed/Output Paralleled) in order to achieve a 3-kV/1.5-kV PET with a nominal power of 600-kW as a prelude to the final 9-kV/1.5-kV power conversion.
- 28 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 7 (2) , 854-869
Characterization and Implementation of Resonant Isolated DC/DC Converters for Future MVdc Railway Electrification Systems
Today, in Electric Railways, the old DC supply systems are reaching their limits. To improve their efficiency and increase railroad traffic, a new DC Electrification has recently been proposed at 9-kV. It is now necessary to prepare the migration of infrastructure and rolling stock, using Power-Electronic-Transformers (PETs), for adaptation to this voltage level. For this application, high efficiency and reduced volume are essential. This paper clearly demonstrates that it is now possible to achieve compact, high-power, isolated DC-DC converters using 3.3-kV SiC-MOSFET power modules with high efficiency. After a preliminary study based on simulations, the paper focuses on characterization and implementation of elementary isolated DC-DC converters. The proposed topology is a series-resonant converter rated for a nominal power of 300-kW at 1.8-kV. First, laboratory testing using an “opposition-method” is used to evaluate the elementary converters up to their nominal power using both electrical and thermal measurements to accurately determine losses and efficiency. At the nominal output power, an efficiency of 98.93% is obtained. This is quite remarkable for an isolated DC-DC converter operating under 1.8-kV with a switching frequency of 15-kHz. Finally, two elementary isolated DC/DC converters are associated in ISOP configuration (Input Seriesed/Output Paralleled) in order to achieve a 3-kV/1.5-kV PET with a nominal power of 600-kW as a prelude to the final 9-kV/1.5-kV power conversion.
- 13 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 4 (2) , 591-604
New Medium-Voltage DC Railway Electrification System
this paper highlights the potential of medium voltage DC electrification for railway traction. A method is proposed for determining the DC voltage level in order to guarantee, in terms of traffic, equivalent performances to an AC electrified railway line. Railroad traffic, type of transport service and railway network topology being given, the analysis method takes into account the following constraints: voltage at the pantograph, heating of overhead-line and rail-to-ground voltage. Once the DC voltage level is chosen, the DC electrification system is compared with a standard 25 kV AC electrification in the case of the French high-speed line from Paris to Strasbourg.
- 13 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 4 (2) , 591-604
New Medium-Voltage DC Railway Electrification System
this paper highlights the potential of medium voltage DC electrification for railway traction. A method is proposed for determining the DC voltage level in order to guarantee, in terms of traffic, equivalent performances to an AC electrified railway line. Railroad traffic, type of transport service and railway network topology being given, the analysis method takes into account the following constraints: voltage at the pantograph, heating of overhead-line and rail-to-ground voltage. Once the DC voltage level is chosen, the DC electrification system is compared with a standard 25 kV AC electrification in the case of the French high-speed line from Paris to Strasbourg.