Eulalie Coevoet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Eulalie Coevoet has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Christian Duriez
Univ. Lille, Inria, CNRS, Centrale Lille, UMR 9189 CRIStAL, Lille, France
4 shared publications - Paul G. Kry
McGill University, Montreal, Canada
2 shared publications - Sheldon Andrews
École de Technologie Supérieure
2 shared publications Adrien Escande
CNRS-AIST Joint Robotic Laboratory UMI3218/RL, Tsukuba, Japan
1 shared publication- Antonin Bernardin
Univ. Rennes, INSA, IRISA, Inria, Rennes, France
1 shared publication D. Relles
McGill University Canada
1 shared publication
Latest Publications
- Open Access
- 14 September 2022
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Graphics
- Vol. 42 (1) , 1-14
Constraint-based Simulation of Passive Suction Cups
In this paper, we propose a physics-based model of suction phenomenon to achieve simulation of deformable objects like suction cups. Our model uses a constraint-based formulation to simulate the variations of pressure inside suction cups. The respective internal pressures are represented as pressure constraints which are coupled with anti-interpenetration and friction constraints. Furthermore, our method is able to detect multiple air cavities using information from collision detection. We solve the pressure constraints based on the ideal gas law while considering several cavity states. We test our model with a number of scenarios reflecting a variety of uses, for instance, a spring loaded jumping toy, a manipulator performing a pick and place task, and an octopus tentacle grasping a soda can. We also evaluate the ability of our model to reproduce the physics of suction cups of varying shapes, lifting objects of different masses, and sliding on a slippery surface. The results show promise for various applications such as the simulation in soft robotics and computer animation.
- 14 September 2022
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Graphics
- Vol. 42 (1) , 1-14
Open AccessConstraint-based Simulation of Passive Suction Cups
In this paper, we propose a physics-based model of suction phenomenon to achieve simulation of deformable objects like suction cups. Our model uses a constraint-based formulation to simulate the variations of pressure inside suction cups. The respective internal pressures are represented as pressure constraints which are coupled with anti-interpenetration and friction constraints. Furthermore, our method is able to detect multiple air cavities using information from collision detection. We solve the pressure constraints based on the ideal gas law while considering several cavity states. We test our model with a number of scenarios reflecting a variety of uses, for instance, a spring loaded jumping toy, a manipulator performing a pick and place task, and an octopus tentacle grasping a soda can. We also evaluate the ability of our model to reproduce the physics of suction cups of varying shapes, lifting objects of different masses, and sliding on a slippery surface. The results show promise for various applications such as the simulation in soft robotics and computer animation.
- 18 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 4853-4860
Planning of Soft-Rigid Hybrid Arms in Contact With Compliant Environment: Application to the Transrectal Biopsy of the Prostate
In this study, a rigid robot is hybridized with a soft part to improve its properties of relative positioning and safe interaction. While the design of the device is quite simple, the kinematics, on the other hand, becomes complex. Pre-operative planning of such a robot is a challenge that is faced in this letter. The clinical context is the automation of transrectal prostate biopsy: a robot is connected to a thin ultrasound (US) probe instrumented with a needle through a flexible silicone part. The procedure consists of: moving the probe near the prostate through the rectum, aligning the probe with identified lesions in the prostate, and shooting the needle to collect tissue samples. In this letter we demonstrate in simulation the feasibility of our methods to solve the planning of the entire procedure. The approach we propose is based on numerical models of both robot and soft tissues, using the Finite Element Method (FEM) to model the soft parts, and a mapping mechanism to propagate the forces and displacements between the soft and rigid models. Finally, we extend the optimization algorithm proposed in previous work for the relative positioning of the hybrid robot on targets in the prostate, as it interacts with the soft tissues. With this formulation we can also set an upper limit to the force the robot is applying on its surroundings, which is particularly critical for the application we study in this letter.
- 18 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 4853-4860
Planning of Soft-Rigid Hybrid Arms in Contact With Compliant Environment: Application to the Transrectal Biopsy of the Prostate
In this study, a rigid robot is hybridized with a soft part to improve its properties of relative positioning and safe interaction. While the design of the device is quite simple, the kinematics, on the other hand, becomes complex. Pre-operative planning of such a robot is a challenge that is faced in this letter. The clinical context is the automation of transrectal prostate biopsy: a robot is connected to a thin ultrasound (US) probe instrumented with a needle through a flexible silicone part. The procedure consists of: moving the probe near the prostate through the rectum, aligning the probe with identified lesions in the prostate, and shooting the needle to collect tissue samples. In this letter we demonstrate in simulation the feasibility of our methods to solve the planning of the entire procedure. The approach we propose is based on numerical models of both robot and soft tissues, using the Finite Element Method (FEM) to model the soft parts, and a mapping mechanism to propagate the forces and displacements between the soft and rigid models. Finally, we extend the optimization algorithm proposed in previous work for the relative positioning of the hybrid robot on targets in the prostate, as it interacts with the soft tissues. With this formulation we can also set an upper limit to the force the robot is applying on its surroundings, which is particularly critical for the application we study in this letter.
- 24 November 2020
- Published by Wiley in Computer Graphics Forum
- Vol. 39 (8) , 113-122
Distant Collision Response in Rigid Body Simulations
- 24 November 2020
- Published by Wiley in Computer Graphics Forum
- Vol. 39 (8) , 113-122
Distant Collision Response in Rigid Body Simulations
- 15 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 2 (3) , 1413-1419
Optimization-Based Inverse Model of Soft Robots With Contact Handling
This letter presents a physically based algorithm to interactively simulate and control the motion of soft robots interacting with their environment. We use the finite-element method to simulate the nonlinear deformation of the soft structure, its actuators, and surroundings and propose a control method relying on a quadratic optimization to find the inverse of the model. The novelty of this work is that the deformations due to contacts, including self-collisions, are taken into account in the optimization process. We propose a dedicated and efficient solver to handle the linear complementarity constraints introduced by the contacts. Thus, the method allows interactive transfer of the motion of soft robots from their task space to their actuator space while interacting with their surrounding. The method is generic and tested on several numerical examples and on a real cable-driven soft robot.
- 15 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 2 (3) , 1413-1419
Optimization-Based Inverse Model of Soft Robots With Contact Handling
This letter presents a physically based algorithm to interactively simulate and control the motion of soft robots interacting with their environment. We use the finite-element method to simulate the nonlinear deformation of the soft structure, its actuators, and surroundings and propose a control method relying on a quadratic optimization to find the inverse of the model. The novelty of this work is that the deformations due to contacts, including self-collisions, are taken into account in the optimization process. We propose a dedicated and efficient solver to handle the linear complementarity constraints introduced by the contacts. Thus, the method allows interactive transfer of the motion of soft robots from their task space to their actuator space while interacting with their surrounding. The method is generic and tested on several numerical examples and on a real cable-driven soft robot.
- Open Access
- 7 April 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 10 (8) , 1193-1200
Registration by interactive inverse simulation: application for adaptive radiotherapy
This paper introduces a new methodology for semi-automatic registration of anatomical structure deformations. The contribution is to use an interactive inverse simulation of physics-based deformable model, computed in real time. The method relies on nonlinear finite element method (FEM) within a constraint-based framework. Given a set of few registered points provided by the user, a real-time optimization adapts the boundary conditions and(/or) some parameters of the FEM in order to obtain the adequate geometrical deformations. To dramatically fasten the process, the method relies on a projection of the model in the space of the optimization variables. In this reduced space, a quadratic programming problem is formulated and solved very quickly. The method is validated with numerical examples for retrieving some unknown parameters such as the Young's modulus and some pressures on the boundaries of the model. The approach is employed in the context of radiotherapy of the neck where weight loss during the 7 weeks of the therapy modifies the volume of the anatomical structures and induces large deformations. Indeed, sensitive structures such as the parotid glands may cross the target volume due to these deformations which leads to adverse effects for the patient. We thus apply the approach for the registration of the parotid glands during the radiotherapy of the head and neck cancer. The results show how the method could be used in a clinical routine and be employed in the planning in order to limit the radiations of these glands.
- 7 April 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 10 (8) , 1193-1200
Open AccessRegistration by interactive inverse simulation: application for adaptive radiotherapy
This paper introduces a new methodology for semi-automatic registration of anatomical structure deformations. The contribution is to use an interactive inverse simulation of physics-based deformable model, computed in real time. The method relies on nonlinear finite element method (FEM) within a constraint-based framework. Given a set of few registered points provided by the user, a real-time optimization adapts the boundary conditions and(/or) some parameters of the FEM in order to obtain the adequate geometrical deformations. To dramatically fasten the process, the method relies on a projection of the model in the space of the optimization variables. In this reduced space, a quadratic programming problem is formulated and solved very quickly. The method is validated with numerical examples for retrieving some unknown parameters such as the Young's modulus and some pressures on the boundaries of the model. The approach is employed in the context of radiotherapy of the neck where weight loss during the 7 weeks of the therapy modifies the volume of the anatomical structures and induces large deformations. Indeed, sensitive structures such as the parotid glands may cross the target volume due to these deformations which leads to adverse effects for the patient. We thus apply the approach for the registration of the parotid glands during the radiotherapy of the head and neck cancer. The results show how the method could be used in a clinical routine and be employed in the planning in order to limit the radiations of these glands.