ARAbu M. Rustum

Abu M. Rustum

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abu M. Rustum has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development of a Reversed-Phase HPLC Method by Applying a Scientific Approach and Strategies to Achieve Challenging Separation of Impurity Peaks in Typical Commercial Bulk Batches of Milbemycin Oxime Drug Substance

    by Renuka P Rathnasekara, Milan K Dissanayake, Sarju Adhikari, Abu M Rustum

    Background: Typical commercial batches of milbemycin oxime (MO) contain over 25 related substances. Many of these related substance peaks exhibit similar chromatographic properties, often coeluting or being poorly separated under current compendial methods. Therefore, an alternative HPLC method with greater selectivity and resolution for MO and its related substance peaks is highly desirable. Objective: This study aimed to develop and validate a new stability-indicating HPLC method for adequately separating all peaks of interest in typical commercial batches of MO. Method: The final HPLC method utilizes a gradient elution on a HALO® C18 column (100 mm × 4.6 mm, i.d. 2.7 µm particle size) maintained at 50°C, with a flow rate of 0.5 mL/min. The composition of mobile phase-A (MPA) for the final method is water–acetonitrile–perchloric acid (70 + 30 + 0.06, v/v/v), and the composition of mobile phase-B (MPB) is isopropanol–methanol–1,4 dioxane–perchloric acid (50 + 45 + 5 + 0.06, v/v/v/v). The injection volume of the new method is 6 µL and the detection wavelength is 240 nm. Results: The new HPLC method demonstrated specificity by adequately separating all potential MO-related substances in stress-degraded MO drug substance. It showed good linearity and accuracy in the range of 0.1 to 120% of the target MO analytical concentration. The LOQ and LOD were determined to be 0.1% and 0.03% of the analytical concentration, respectively. The robustness study found no critical parameters affecting the method's specificity or accuracy. Conclusions: The new HPLC method offers greater selectivity and resolution compared to compendial methods for the MO drug substance. It is more desirable for batch release and stability studies in both routine and non-routine activities. Highlights: An exhaustive equivalency study between the new HPLC method and the compendial methods demonstrated that the new method is superior compared to the European Pharmacopoeia (Ph. Eur.) method for analyzing MO bulk drug substance.


  • Development and Validation of a Single Stability-Indicating Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) Method for Identification and Assay of Eprinomectin in Two Different Commercial Injectable Drug Products for Cattle

    by Nayanthara U Dharmaratne, Abu M Rustum

    Background: Eprinomectin (EPRN) is a semi-synthetic macrocyclic lactone exhibiting antiparasitic activity and is widely used as an active pharmaceutical ingredient (API) in veterinary drug products. Objective: This study aimed to develop a single stability-indicating reversed-phase (RP)-HPLC method to identify and assay EPRN in two different injectable drug products for cattle. Methods: The RP-HPLC method is carried out on a Halo-C18 column (100 mm × 4.6 mm id, 2.7 µm particle size) maintained at 55°C. The analytes are separated by a gradient elution at a flow rate of 0.8 mL/min and detected at a wavelength of 245 nm. The mobile phase-A (MPA) of the method is 0.1% (v/v) aqueous perchloric acid, and mobile phase-B (MPB) is ethanol (EtOH). The Ascentis Express C18 column (100 mm × 4.6 mm id, 2.7 µm particle size) was identified and validated as an equivalent column for the prescribed method. Results: The RP-HPLC method described in this article can adequately separate all major related substances of EPRN in the two drug products from EPRN B1a and EPRN B1b within 20 min. Conclusion: The developed RP-HPLC method for the identification and assay of EPRN was successfully validated in accordance with the guidelines outlined in the International Conference on Harmonization (ICH) Q2(R2), and demonstrated to be robust, linear, accurate, precise, specific, and stability-indicating. Highlights: The new RP-HPLC method exhibits a higher level of selectivity but is yet rapid and simple, making it suitable for routine and non-routine analysis in research and QC laboratories.


  • Simultaneous Determination of Fipronil, Permethrin, and Their Key Related Substances in a Topical Drug Product by a Single Stability-Indicating High-Performance Liquid Chromatography Method

    by Renuka P Rathnasekara, Jingzhi Tian, Abu M Rustum

    The topical veterinary drug product containing fipronil and permethrin provides an effective repellent protection and high insecticidal efficacy for dogs. The objective of this study was to develop a stability indicating high performance liquid chromatography (HPLC) method for simultaneous detection and quantification of fipronil, permethrin, their key degradation products and butylated hydroxytoluene (BHT) in a topical drug product. The two active ingredients, their degradation products, and the antioxidant (BHT) were separated by a gradient elution on a Phenomenex Kinetex C18 column (150 × 3 mm, 2.6 µm particle size) maintained at 37 °C with H2O/acetonitrile/isopropyl alcohol/85% H3PO4 (65.5 + 32.5 + 4/0.0053, v/v/v/v) as mobile phase-A and acetonitrile (100%) as mobile phase-B. The flow rate was 0.9 mL/min and analytes were detected and quantified at 235 nm. Specificity of the method was demonstrated by adequate separation of fipronil, permethrin, their degradation products, and BHT in the forced degraded finished product. Linearity of the method was demonstrated in the range of 0.2% to 150% of target analytical concentration of both active ingredients and 50% to 150% for BHT. Excellent recoveries of fipronil, permethrin and BHT in placebo spiked active ingredient solutions in the linearity range showed sufficient accuracy of the method. LOQ and LOD of the method were determined to be 0.2% and 0.07% of the analytical concentration. A robustness study did not identify any critical parameter that adversely effected the separation and quantification. Here, we report the development and validation of a robust, stability indicating HPLC method for identification and assay of fipronil, permethrin, and BHT, including estimation of fipronil’s and permethrin’s degradation products in a topical drug product for dogs. The new HPLC method permits the acquisition of data for all analytes of interest for a topical finished drug product containing fipronil, permethrin, and BHT.


  • Improved Stability-Indicating RP-UPLC Method for the Levamisole Hydrochloride Assay and Estimation of Its Related Compounds

    by Sarju Adhikari, Abu M Rustum

    Levamisole Hydrochloride (LVM) is an anthelmintic drug substance with immunomodulatory and anticancer activities. LVM has also found its usage as a cutting agent in street cocaine. This study was aimed to develop and validate an alternative and improved stability-indicating reversed-phase ultra-performance liquid chromatography (RP-UPLC) method for the determination of LVM and the estimation of its related compounds. The UPLC method for the assay was optimized in terms of organic solvents consumed, pH, column temperature, and flow rate. Determination of LVM and its related compounds was performed using a gradient elution on a Waters Acquity UPLC® BEH C18 (50 mm × 2.1 mm i.d., 130Å). The column temperature was maintained at 35 °C. Mobile phase-A is composed of aqueous 5 mM ammonium hydroxide and mobile phase-B is composed of acetonitrile. All the analytes were monitored by UV detection at 215 nm with a flow rate of 0.7 mL/min. The total runtime of the method with column equilibration is 4.0 min. The developed method met all the acceptance criteria of the current International Council for Harmonization (ICH Q2 (R1)) guidelines. The method was tested in terms of specificity, linearity (R2 > 0.999), limit of detection (0.06 μg/mL), limit of quantitation (0.2 μg/mL), accuracy, precision, and robustness. With a short analysis time (<2.5 min) and reduced consumption of organic solvents, the proposed method is considered a greener alternative to conventional chromatographic methods. An alternative and improved UPLC method was successfully developed and validated as per the ICH guidelines for the determination of LVM and the estimation of its related compounds. Due to its high degree of selectivity, speed, and accuracy, the developed method can significantly benefit the end-users with laboratory efficiency and throughput during routine analysis of production batches and stability monitoring of LVM-related drug products.


  • Development and Validation of a Stability-Indicating Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) Method for Identification, Assay, and Estimation of Related Substances of Ivermectin Drug Substance

    by Rasangi M Wimalasinghe, Daoli Zhao, Lin Wang, Abu Rustum

    Background: Ivermectin is a potent semi-synthetic antiparasitic drug used in veterinary medicine. It is widely used for the treatment of parasites. Objective: This study aimed to develop a stability-indicating reversed-phase HPLC (RP-HPLC) method for assay and identification of ivermectin including identification and estimation of its related substances in bulk drug substance batches of ivermectin. Method: Ivermectin and its related substances were separated on an Ascentis Express C18 column (100 mm × 4.6 mm id, 2.7 µm particle size) maintained at 45°C (column temperature) on an HPLC system with gradient elution. The mobile phase was composed of water − acetonitrile (ACN; 50 + 50, v/v) as mobile phase A, and isopropanol − ACN (15 + 85, v/v) as mobile phase B. Analytes were detected with a detection wavelength of 252 nm and quantitated against an external reference standard of ivermectin with a quantitation limit of 0.1% of the target (analytical) concentration. Results: The HPLC method was able to separate all analytes of interest by gradient elution within 25 min. The method was validated according to the guidelines described in the International Conference on Harmonization guideline Q2(R1). Conclusions: The HPLC method for assay of ivermectin and estimation of its related substances was successfully developed, validated, and demonstrated to be accurate, robust, specific, and stability indicating. Highlights: The performance of the HPLC method is significantly faster and possesses a higher degree of selectivity. Implementation of this method for routine analysis in QC laboratories would save significant time, resources and solvents.


  • Alternative and Improved Stability-Indicating HPLC Method for the Assay of Eprinomectin and Determination of Its Related Compounds in Bulk Batches of Eprinomectin Drug Substance

    by Nilusha Padivitage, Jingzhi Tian, Abu Rustum

    Background: Eprinomectin is used as an active pharmaceutical ingredient (API) in various drug products by the animal health industry. Several major related impurities of eprinomectin API are not separated and coelute by the current United States Pharmacopeia (USP) method for eprinomectin. Objective: The aim was to develop and validate a true and reliable stability-indicating reversed-phase (RP) HPLC method for assay and determination of related substances of eprinomectin in bulk batches of eprinomectin API. Method: HPLC analysis is carried out using a Kinetex C8 column (100 mm × 4.6 mm i.d. , 2.6 μm particle size) maintained at 30°C with water–acetonitrile–isopropanol (48 + 42 + 10, v/v/v) as mobile phase A and 100% acetonitrile as mobile phase B. Analytes are separated by gradient elution at a flow rate of 0.7 mL/min and detected by UV at 252 nm. The total run time of the method is 30 min. Eprinomectin assay and estimation of all eprinomectin-related substances are obtained in a single HPLC run. Results: The HPLC method was able to separate all analytes of interest by gradient elution. The new method was successfully validated according to current The Internal Council for Hamonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) and International Cooperation on Hamonisation of Technical Requirements for Registration of Veterinary Medicinal Products (VICH) guidelines and was found to be specific, linear, accurate, precise, robust, and sensitive. Conclusions: An HPLC method for assay of eprinomectin and estimation of its related substances was successfully developed, validated, and demonstrated to be accurate, robust, specific, and stability-indicating. Highlights: The HPLC method presented in this paper is more desirable as compared to USP and suitable for routine analysis of bulk batches of eprinomectin API and stability samples in QC laboratories.


  • THE RETENTION BEHAVIOR OF LORATADINE AND ITS RELATED COMPOUNDS IN ION PAIR REVERSED PHASE HPLC

    by Jun Lu, Yu Chien Wei, Robert J. Markovich, Abu M. Rustum

    Organic amines are important pharmaceutical molecules and appropriate reversed phase HPLC methods for quality control are desirable for them. The development of IP-RPLC methods is challenging for complex profiles of organic amines. Mobile phase pH and ion pair reagent concentration are two important factors affecting the retention behavior of organic amines in IP-RPLC. Loratadine and its eight related compounds were used as the model compounds for studying their retention behavior and the elution profile using a gradient IP-RPLC condition. The parameters examined included the mobile phase pH and the concentration of an ion pairing reagent, SDS. The chromatographic separation and retention factor (k) of each analyte were monitored at different SDS concentrations (0 to 20 mM) and different pH values (6.2 and 3.0). Due to the basicity of the nine compounds in the study, each compound responded differently to the varying ion pairing reagent (SDS) mobile phase concentrations at different pH values. The ionized analytes had increasing retention factors with increasing SDS concentration, while the non-ionized analytes had nearly constant retention factors as a function of the SDS concentration. For the nine organic amines studied, optimal overall separation and resolution were achieved at 3 mM SDS under pH of 6.2 and at 1 mM under pH 3.0, respectively.