HBH. Blahodarna

H. Blahodarna

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


H. Blahodarna has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Measures to Prevent Destruction of Water Systems after Supply of Water with High Salt Con-tent through Networks

    by Volodymyr Kobylianskyi, Oleksandr Kravchenko, Tamara Shevchenko, Halyna Blagodarna

    The article considers the current problem of corrosion destruction of steel water supply networks, which arose as a result of the transition of water supply systems from a source of fresh water to a source with highly mineralized water. This approach to changing the source of water supply is due to the impossibility of taking water from a fresh source due to the military aggression of the Russian Federation. This, in turn, led to accelerated aging of pipelines and an increase in the number of accidents. The study of samples of steel pipes with a diameter of 76 to 500 mm, which were operated for more than 40 years, showed that the process of electrochemical corrosion is complicated by intensive leaching of corrosion deposits from the inner surface of the pipes. This causes a decrease in metal thickness, loss of mechanical strength and the formation of galvanic couples of the “deposit-metal” type, which, in turn, in water with an increased chloride content significantly accelerate corrosion processes. In order to find effective methods to combat network destruction, experimental studies were conducted using three types of reagents: slaked lime, liquid glass (sodium silicate) and polyhexamethyleneguanidine hydrochloride (PHMG). For each reagent, the optimal doses, concentrations and conditions of use were determined, and their effect on the corrosion rate of the metal and the stability of deposits was studied. The results showed that although these reagents are able to partially reduce the corrosion activity of the environment, they do not guarantee the cessation of pipe destruction processes, since they do not eliminate the influence of external corrosion caused by salinization of the soil around the pipelines. In addition, their use can lead to deterioration in the sanitary and chemical indicators of water quality, which makes it impossible to meet the requirements for drinking water supply. The results obtained indicate that to restore the reliability of water supply systems, it is necessary to completely replace steel pipes damaged by corrosion. To reduce the accident rate, it is advisable to use modern anti-corrosion materials and combined protection methods, which provide not only for the inhibition of metal corrosion, but also for the stabilization of existing deposits to prevent their leaching and repeated exposure of the metal. The proposed approaches can be used during the reconstruction of water supply systems in regions with increased mineralization of natural waters.


  • Open Access

    RESEARCH ON THE EFFICIENCY OF RAPID FILTERS UNDER DIFFERENT FILTERING MODES

    by A. Karahiaur, M. Mykhailov, A. Titov, H. Blahodarna

    Increasing the duration of rapid filter operation between washings is an effective way to reduce the amount of washing water and operating costs at water treatment stations for domestic and drinking needs when drawing from surface sources. The level of pollution of surface water supply sources in Ukraine is steadily increasing. During military operations, the load on treatment facilities may rise significantly. Moreover, operating conditions can change abruptly and unpredictably. This article presents the results of a study comparing the performance of rapid filters in two filtration modes: with constant and time-varying filtration rates. The theory of low-concentration suspension filtration developed by D.M. Mints applies to the mode with a constant filtration rate. Calculations for alternative filtration modes require more general theoretical frameworks. The studies were conducted using a mathematical model. The presented mathematical model includes: the filtration equation for a low-concentration suspension, the equations of mass transfer and mass transmission of the suspended solids from the liquid phase to the solid (grains of the filter media), the formulations for determining the resistance of clean (unclogged) media and the influence of clogging on the resistance and porosity of the granular media, the expressions for calculating the adhesion (and detachment) coefficients of suspension particles on the filter media grains. The adequacy of the mathematical model at a constant filtration speed was validated by comparing the calculated results with the data obtained using the filtration theory of D.M. Mints. As a result of numerical experiments for two filtration modes, the impact of influent water turbidity on the efficiency of the rapid filter was investigated. The filter operating time between washings used as the efficiency criterion. The comparison of the two modes was conducted under the condition that the average productivity and filtration area in both cases were the same. The influence of the granular media parameters (grain size and layer thickness) was investigated. Studies have shown the advantages of operating a rapid filter in a variable filtration rate mode compared to a constant rate mode. However, the disadvantage of the variable filtration rate mode is the increased likelihood of filtrate quality deterioration at the beginning of the filtration cycle.

  • Open Access

    IMPROVEMENT OF OPERATION AND RESEARCH METHODOLOGY OF THE HYDRAULIC FLAKE FORMATION CHAMBER FOR DRINKING WATER SUPPLY

    by S. Epoian, T. Airapetian, O. Haiduchok, H. Blahodarna, V. Volkov

    Ukraine’s surface water sources are unsatisfactory due to pollution caused by industrial and agricultural activities and the Russian invasion. As the natural water quality deteriorates, the treatment plant’s efficiency in preparing drinking water for the population’s needs decreases. The hydraulic flake formation chamber allows for physicochemical processes that produce large and solid flakes of metal hydroxides with impurities that quickly settle and are then removed from the water. This study aims to develop a methodology for experimental research on the new design of a swirl-vortex flake formation chamber that intensifies the water purification process in the domestic and drinking water supply systems. The proposed design of the swirl-vortex chamber has dimensions of 0.75×2.0 m and a height of 0.65 m. Due to the installation in the first section of 4 fittings with nozzles, two pieces on each pipe, and in the second section, six fittings with nozzles, three pieces on each pipe with a diameter of 6–10 mm, it is possible to increase the effect of water illumination. The authors performed hydraulic modelling following the Reynolds criterion (Re) and the Froude criterion (Fr). We conducted experiments using artificial turbidity water. White-blue clay was used as a turbidant because it contains more small particles than the white-green one. We decided to model flake formation chambers according to the Froude criterion (Fr). Modelling according to the Reynolds criterion leads to such large velocity gradients that it simply does not make sense to talk about flake formation processes. We carried out the second series of experiments to obtain a qualitative assessment of the swirl-vortex chamber’s work in forming flakes by studying the deposition of flakes at different velocity gradients and angles of inclination of the nozzles. The best effect of lightening the water in the flake formation chamber occurs at a nozzle inclination angle of 45° to the bottom. The best effect of water clarification happens at a velocity gradient of about 60 s-1 and the water residence time in the flake formation chamber of 200–300 s. Keywords: water treatment, intensification, flake formation chamber, drinking water supply.

  • Open Access

    SPECIFICS OF WASTEWATER PARAMETERS CALCULATION, WHICH SHOULD BE DETERMINED WHEN DRAWING UP RULES FOR RECEIVING WASTEWATER INTO THE CITY SEWERAGE SYSTEM

    by S. Epoyan, I. Chub, H. Blahodarna

    The article analyzed the problems of environmental monitoring and the level of automation for predicting the state of the environment and the level of use of computer information and analytical systems for environmental expertise. It is established that in order to improve the environmental safety management system and automate the processes of assessing the impact of economic activity on the environment, it is necessary to create software packages aimed at solving various environmental problems, namely receiving wastewater from enterprises to the urban sewerage systems. It is known that the relationship between consumers and water utilities is governed by the Rules of sewage. According to these Rules, the permissible concentrations of pollutants contained in the wastewater of enterprises are determined. But such calculations are characterized by a large number of parameters and a large amount of input data. The authors of the article developed a software package for calculations and rationing of wastewater quality indicators of enterprises that discharge their wastewater into the sewerage network of cities and may disrupt the operation of treatment facilities. In general, the developed software package will reduce the time and perform calculations to determine the permissible concentrations of pollutants in the wastewater of enterprises (consumers), and at the same time analyze large data sets. Automation of the main components of environmental procedures will increase the efficiency and reliability of urban sewerage systems and more effectively assess the impact on the environment. Also, the created software complex will determine the concentration of heavy metals in the sewage sludge and ensure its use as a fertilizer containing more phosphorus and calcium. It should be noted that the created software package allows you to perform such calculations that are difficult to perform in Excel. You can export data from any source - WEB, Excel, OpenOffice. Data and calculation algorithms are separated, which minimizes error. The software package was created using Node.js technology.

  • CONTACT CLARIFIERS IN THE PREPARATION OF DRINKING WATER

    by S. Dushkin, G. Blagodarna, T. Shevchenko

    The article discusses the problem of improving the technological process of clarifying water for drinking purposes using contact clarifiers, which allows to reduce the consumption of reagents, improve water quality, reduce capital and operating costs, and reduce the cost of water. The method of water treatment, based on the use of the phenomenon of contact coagulation, is called the method of contact clarification. This method is able to provide a high and stable effect under various physicochemical conditions of coagulation, changing according to the seasons of the year with lower doses of coagulant than in the usual scheme of water treatment with sedimentation and filtration. It was found that the contact coagulation of suspended and colloidal impurities of water on sand grains when water moves through granular filters is faster, more complete, more stable when the physicochemical conditions of coagulation change according to the seasons of the year. And, finally, at lower doses of coagulant than the usual coagulation of these impurities in the free volume of water in flocculation chambers and settling tanks. It is advisable to use contact clarifier in one-stage treatment schemes for low-turbid colored waters, when the total content of suspended solids in the water supplied to the contact clarifiers, including the suspension that is formed as a result of the introduction of reagents into the water, does not exceed 150 mg/dm3. With a higher suspension content in water, the water consumption for flushing contact clarifiers increases sharply. It was found that the zones of contact coagulation when using a conventional coagulant solution are slightly smaller than when treating water with a modified solution of aluminum sulfate (the latter takes place on the curves of contact coagulation of both low-turbid and turbid waters). The analysis of contact coagulation zones shows that when treating water using a modified coagulant solution, it makes it possible to reduce the calculated doses of coagulant by an average of 30-45% without deteriorating the quality of water clarification.