SYSüleyman Yıldız

Süleyman Yıldız

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Süleyman Yıldız has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Integration of Electric Charging Stations into Sustainable and Renewable Energy: A Case Study

    by Soner Çelikdemir, Süleyman Yıldız

    This study evaluates the potential for sustainably operating the Electric Vehicle (EV) charging infrastructure in Bitlis Province through a wind-solar hybrid generation system complemented by an 8 MWh Battery Energy Storage System (BESS), using a representative charging site as a detailed case study. Following the development of a spatial and technical inventory of EV charging stations across the province, a station strategically located on an intercity transit corridor was selected for in-depth analysis. To this end, the demand profile was modeled on a monthly basis by accounting for the national EV penetration rate, seasonal charging frequency, and alternative charging scenarios. On the supply side, the seasonal variability of wind and solar resources was simulated at high temporal resolution using local meteorological data. The analyses indicate that single-source solutions may conflict with the objective of service continuity under the conditions prevailing in Bitlis, potentially leading to significant unmet demand during resource-scarce periods. By contrast, a hybrid wind-solar configuration, when coupled with appropriately sized storage, can render the charging infrastructure technically and operationally sustainable, achieving full year-round service continuity. In this context, a configuration comprising 10 kW of wind capacity and 5 kW of solar is proposed. Under this configuration, the lowest monthly generation is 1,315.6 kWh in November, while the highest is 7,027 kWh in March. The maximum battery storage requirement of approximately 7,134 kWh was identified, leading to the recommendation of an 8 MWh BESS to ensure uninterrupted year-round EV charging service. The system meets an average monthly demand of approximately 2,500 kWh, with surplus energy stored during high production months and deficits covered during low production periods. The cumulative energy balance indicates a surplus of 788 kWh by the end of the year, which can be utilized for emergencies or other operational needs. The study provides a transferable planning framework for regions with similar infrastructural and meteorological characteristics, demonstrating the quantitative impact of local resource integration on EV charging infrastructure resilience.

  • Performance Evaluation of Proton Exchange Membrane Fuel Cell Under Different Operating Conditions for Aircraft Applications

    by Soner Çelikdemir, Süleyman Yıldız

    Under various operating conditions. The originality of this work lies in the detailed investigation of both single and dual parameter variations on system output power, conducted through a MATLAB/Simulink based model. The key parameters examined include temperature, pressure, relative humidity, and contact resistance, each systematically varied individually and in pairs within specified ranges. The isolated effects of each variable and parameter pair on fuel cell performance are thoroughly evaluated. The novelty of this study lies in the modeling approach, which significantly reduces experimental costs and time, while enabling the determination of optimal operating parameters. The results provide valuable guidance for identifying the optimal power region and corresponding operating parameters for PEMFC integration in aviation. This comprehensive analysis contributes to the advancement of fuel cell based aviation applications and the improvement of system design processes. Furthermore, a system-level assessment is conducted by integrating a simplified Balance of Plant (BoP) model, which quantifies parasitic loads and reveals their impact on net power and overall efficiency at the 250 W operating point. Quantitatively, at the 250 W operating point, the modeled gross stack efficiency is 54.96%, while inclusion of the BoP reduces the net system efficiency to 46.55%. This reduction arises from the combined effect of parasitic loads, predominantly the air compressor, along with the humidifier, cooling pump, fan, and power electronics.


  • Open Access

    An Autonomous Frequency Control Mechanism for Multi-Area Microgrids Incorporating with Distributed Energy Resources

    by Süleyman Yildiz, Hasan Gunduz, Burak Yildirim, Mahmut Temel Ozdemir

    Due to the intermittent nature of distributed energy resources (DER) utilised in power grids, considerable frequency variations arise when the capacity of the load frequency control (LFC) system is inadequate to correct for electricity generation and consumption imbalances. This issue may significantly increase when the microgrid is operating in isolated mode. Meanwhile, hydrogen-fuel cells are gaining traction as distributed energy storage units, assisting in the transition to a low or zeroemissions while also providing for greater operational flexibility with maintaining frequency stability. Nevertheless, power grids constantly face various uncertainties. To mitigate these uncertainties, this study purposes a new dual-input interval type-2 fuzzy fractional order PI-PD (DIT2-FPI-FPD) cascade controller with recently developed Improved-Salp Swarm Algorithm (I-SSA) for LFC of multi-area microgrids incorporating with various DER. The simulations are performed with real-time sun/wind data and genuine random load changes. Robustness of the proposed controller has been verified by sensitive case studies, which are showing the proposed controller is optimal and highly efficient.


  • Investigation of Load Frequency Control with Optics Inspired Optimization Algorithm in a Four Area Power System with HVDC Connection Line

    by Suleyman Yildiz, Burak Yildirim, Mahmut Temel Özdemi̇r

    It is considerably important that the energy is presented to consumer as quality and confidential in the production of electrical energy. It is expected to continuously track and control the supply and demand relationship between producers and consumers by reliable power system. In this sense, the most significant parameter to be controlled in interconnected systems is the system frequency. The frequency deviation must be kept within certain limits in the power system; this is realized by maintaining the balance of power generation and power consumption. In this study, the effect of High Voltage Direct Current (HVDC) transmission lines parallel to Alternative Current (AC) transmission line is investigated on power system frequency control in the High Voltage Alternating Current (HVAC) transmission line and connected to each other in a power system formed by sub-areas. For that purpose, respectively a multi area power system in accordance with Turkey’s facts were modeled in MATLAB in this study. The effects of adding one and more HVDC transmission lines to this power system on load frequency control were investigated. The examination was fulfilled for three cases. These are the conditions where there is no DC connection, the ideal DC connection and the DC connection with PLL. In this study, the gain of controllers were determined by Optics Inspired Optimization (OIO) method. The determined controller gains were used for the time domain responses in the generated model and also results were analyzed.


  • The Effects of HVDC Connection Line on Small Signal Stability in Four-Area Power System

    by Burak Yildirim, Suleyman Yildiz, Mahmut Temel Özdemi̇r

    High Voltage Direct Current (HVDC) systems which is a power electronics technology, will affect the control and stability of power systems with developments in power electronics. In this study, the effect of HVDC lines connected in parallel to High Voltage Alternating Current (HVAC) transmission lines on system stability and frequency oscillations were investigated in a four-area interconnected power system. The model of a four-area power system was created in Matlab / Simulink environment in this study. Two scenarios have been created for the study, the scenario of adding a HVDC connection between area 1 and area 2 and including the scenario of adding HVDC connection between area 1 and area 2 and between area 1 and area 3. Three different cases which are namely, only with alternating current (AC) connection, direct current (DC) connection parallel to AC lines and DC-connected state with phase-locked loop (PLL) parallel to AC lines were examined in each scenario cases. In a 4-area power system, the gains of the controllers were determined using the Optics inspired optimization (OIO) algorithm with Integral Squared Error (ISE) objective function. In the continuation of the study, eigenvalue analysis study was performed for 4-area power system whose controller gains were determined and eigenvalues of the models were obtained. Afterwards, relationship between eigenvalues and state variables was determined via sensitivity analysis. With the help of the analysis studies, it was tried to show the effects on the frequency oscillations and stability of the areas to which they are connected by adding HVDC connection lines with and without PLL to the power system.