FWFangling Wu

Fangling Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fangling Wu has a total of 71 co-authors. Here are the top co-authors by number of shared publications:

  • Chuan-Fan Ding

    Ningbo University

    15 shared publications
  • Chuan-Fan Ding

    Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China

    8 shared publications
  • Chaoxian Chi

    Zhejiang Provincial Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, China

    5 shared publications
  • Huanhuan Wang

    Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang, 315211, China

    4 shared publications
  • Sisi He

    Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China

    4 shared publications
  • Xishi Wu

    Chinese Academy of Sciences 1219 Zhongguan West Road

    4 shared publications

Latest Publications

  • Rapid Recognition of Matrine Enantiomers Using Ion Mobility–Mass Spectrometry and Theoretical Modeling with Macrolide as Chiral Selectors

    by Huang Zhao, Fangling Wu, Jiaxin Wang, Haibo Zhu, Shiqi Wang, Xishi Wu, Chuan-Fan Ding

    The precise analysis of chirality is crucial for elucidating their stereoselective effects. Ion mobility–mass spectrometry (IM-MS) is a promising tool for chirality analysis, yet it is constrained by limited resolving power and the correlation between collision cross-section (CCS) values and accurate structures. In this work, a rapid method for recognizing matrine (MAT) and its enantiomer sophoridine (SPD) was established using IM-MS and theoretical modeling. With Natamycin (Nat) and Amphotericin B (Amp) as chiral selectors, binary noncovalent complexes were formed with target analytes to enhance stereostructural differences and enable separation. MAT and SPD were effectively separated via [MAT/SPD+Nat+H]+ and [MAT/SPD+Amp+H]+ complexes, with peak-to-peak resolutions (Rp–p) of 1.12 and 3.46, yielding 12.2 and 37.6-folds higher than that of free-state enantiomers (0.092), respectively. Theoretical modeling and noncovalent interaction analysis revealed key interaction sites and force types, explaining the differences in mobility behavior at the molecular level. Surface electrostatic potential analysis reveals that smaller CCS values of the complex relate to concentrated negative potential and stronger surface polarity, while larger CCS values lead to dispersed negative potential and weaker polarity. Tandem mass spectrometry confirmed stability variations between isomeric complexes, with larger CCS differences correlating with more significant dissociation energy differences. Applied to practical samples, the method achieved a detection limit of 0.0011 μmol·L–1, recoveries ≥76.00% and relative standard deviations ≤4.62%, and the mechanistic conclusions derived from MAT/SPD can be generalized to other matrine-type alkaloid enantiomers, thereby providing a robust and efficient universal solution for their rapid analysis.

  • Open Access

    Discriminating quinine stereoisomers through collision cross-section differences enhanced by cyclodextrin complexation

    by Haibo Zhu, Jiaxin Wang, Shiqi Wang, Shugai Feng, Fangling Wu, Chuan-Fan Ding

    Quinine (QN) and its derivatives, such as quinidine, hydroquinine (HQN), and hydroquinidine (HQD), are important therapeutic agents with significant biological and pharmacological properties. However, their stereoisomeric nature poses challenges for separation and identification due to their similar mass-to-charge ( m/z ) ratios. In this work, a simple and quick method based on trapped ion mobility spectrometry-mass spectrometry (TIMS-MS) and theoretical calculations was developed to effectively separate and identify QN stereoisomers and their derivatives by forming diastereomeric complexes with cyclodextrins (α, β, and γ-CD). The separation efficiency improved with the enlargement of the CD cavity, achieving an R p-p value of 1.23. density functional theory (DFT) calculations and independent gradient model (IGMH) analysis provided insights into the molecular interactions and conformational variations among the complexes, revealing how differences in interaction sites and types lead to distinct conformations. The reliability of these calculations was supported by the good agreement with experimental collision cross-section values, which showed deviations ranging from only 4.12% to 8.84%. Additionally, tandem mass spectrometry (MS/MS) was employed to analyze the structural stability of the complexes, revealing differences in dissociation energies. Quantitative analysis demonstrated excellent linearity (R 2 > 0.99) and precision (RSD ≤ 2.32%), with recovery rates in serum and urine samples exceeding 84.0%. This method offers a rapid, accurate, and efficient approach for the separation and quantification of QN stereoisomers, with potential applications in pharmaceutical research and quality control.

  • Unraveling Chiral Recognition for Ofloxacin Enantiomers: An IMS-MS Study Enabled by Noncovalent Complexation and Theoretical Modeling

    by Xue Yang, Yao Pan, NaiSheng Wu, Huiqing Ding, Fangling Wu, Li Ding, Chuan-Fan Ding

    The precise analysis of chiral drugs is crucial for elucidating their stereoselective pharmacological effects. As a commonly used fluoroquinolone antibiotic, ofloxacin (OFLX) exhibits different pharmacodynamics between its R- and S-OFLX, highlighting the need for efficient chiral analysis methods. This study developed a strategy based on trapped ion mobility spectrometry-mass spectrometry (TIMS-MS) and noncovalent complex formation for the rapid separation and quantification of ofloxacin enantiomers. Vancomycin and gentamicin C1a were selected as chiral selectors to form binary noncovalent complexes with the target enantiomers. TIMS analysis demonstrated that the complexes formed between R-/S-OFLX and both chiral selectors achieved baseline separation, with peak-to-peak resolution values of 1.94 and 3.34, respectively. To clarify the structural basis of chiral recognition, density functional theory calculations and the independent gradient model were employed, revealing key stereospecific weak interactions within the complexes, thereby providing critical atomic-level insight into the differential migration behavior observed in TIMS experiments at the molecular level. Based on these findings, both relative and absolute quantification methods for the enantiomers were established, both demonstrating excellent linearity and high sensitivity. Finally, the method was successfully applied to determine ofloxacin in artificial urine samples, achieving recoveries of no less than 70.60%, confirming its applicability in complex real-world matrices. This derivatization-free approach provides a robust and efficient solution for the rapid analysis of chiral drugs.

  • A tunable analytical platform for bile acid isomers: from molecular recognition to pharmaceutical quality control

    by Manli Zhang, Ziyu Qu, Wei Li, Jia Wang, Chaoxian Chi, Di Zhang, Chuan-Fan Ding, Fangling Wu

    This study presents an innovative Trapped Ion Mobility Spectrometry-Mass Spectrometry (TIMS-MS) approach employing rifampicin (RFP) and Ba2+ coordination chemistry to address the analytical challenges posed by structurally similar bile acid (BA) isomers. Our methodology facilitates the formation of distinctive ternary complexes that enable effective isomer separation, achieving separation resolution (Rp-p) values reached to 2.77. Otherwise, theoretical calculation modeling revealed that the differential binding interactions between RFP/Ba2+ and various BA isomers underlie the separation mechanism, with theoretical predictions showing remarkable consistency with experimental results (≤ 3.0% error). The technique demonstrates outstanding quantitative reliability (R2 > 0.99) and has been successfully implemented in both pharmaceutical formulation analysis and serum sample testing. Characterized by its operational simplicity, rapid analysis time, and high sensitivity, this robust analytical platform offers significant potential for advancing BA research in pharmaceutical quality control, clinical diagnostics, and regulatory compliance applications.


  • Molecular-Level Insights into TIMS-MS Separation of α/β-Estradiol Isomers: Synergistic Effects of Cyclodextrins and Metal Ions

    by Naisheng Wu, Fangling Wu, Sisi He, Jia Wang, Huiqing Ding, Chuan-Fan Ding

    This study presents a novel approach for the rapid and high-resolution separation of estrogen isomers (α/β-estradiol and estriol: α/β-E2/E3) using trapped ion mobility mass spectrometry (TIMS-MS). Systematically, evaluating cyclodextrin (α-, β-, and γ-CD) as separation reagents and exploring metal ions as coordinating ligands, we achieved enhanced isomer differentiation, in which the separation resolution (RP-P) was increased from 0.204 to 1.533. Density functional theory (DFT) calculations and noncovalent interaction visualization analysis provided molecular-level insights into the structural and interaction differences driving these separations, highlighting the critical roles of host-guest interactions and metal coordination geometry. Additionally, quantitative analysis and method validation for the estrogen isomers were measured, with a good linearity of R2 value higher than 0.99 and RSD ≤ 2.28%. Finally, the method was applied to detect and quantify α/β-E2/E3 in human urine samples; good recoveries of ≥79.78% were obtained with RSD ≤ 4.35% for intraday and RSD ≤ 9.56% for interday. The combined experimental and theoretical results demonstrate the potential of this TIMS-MS-based strategy for clinical diagnostics and bioanalytical applications requiring precise estrogen isomer separation.


  • Rapid separation of bile acid isomers via ion mobility mass spectrometry by complexing with spiramycin

    by Manli Zhang, Yao Pan, Shugai Feng, Chaoxian Chi, Fangling Wu, Chuan-Fan Ding

    Bile acid (BA) is one of the main active components of bile and has multiple isomers, the structure or content of its isomers often changes due to diseases and other health problems; thus, the accurate detection of BA isomers is very important. In this study, two groups of BA isomers of glycine-conjugated BAs and taurine-conjugated BAs were simultaneously separated and quantitatively analyzed by ion mobility mass spectrometry (IM-MS). Especially, baseline mobility separation between the isomers was achieved by the formation of binary complexes via simple interaction with spiramycin (SPM), for which a separation resolution (Rp-p) of 1.96 was reached. Moreover, BA isomers were quantitatively analyzed, and the limit of detection (LOD) of absolute quantification for TCDCA/TUDCA and GUDCA/GCDCA/GHDCA was 0.514 and 0.611 ng∙mL−1, respectively; the LODs for molar ratio ranges of relative quantification for TCDCA/TUDCA, GUDCA/GHDCA, and GCDCA/GHDCA were 1:18–30:1, 1:18–21:1, and 1:19–21:1, respectively. Additionally, BA isomers analyzed in pig bile powder and bear bile powder were measured, which were in good consistency with those labeled, revealing the differences in BA composition and content between the two powders. Finally, BA detection and recovery analyses were performed on serum samples, with a recovery rate of ≥73.69%, RSD of ≤6.8%, and SR (standard deviation of recoveries, the degree of difference between measured values and average recovery) of ≤1.27. Due to the simple, rapid, and lack of need for complex sample preparation and chromatographic separation, the proposed method can be an effective method for BA detection in practical samples.