Jialin Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jialin Shi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Ji Wu
Department of Electronic Engineering, Tsinghua University, Beijing, China
3 shared publications- Ji Wu
Tsinghua University
3 shared publications - Zongjie Wang
School of Computer and Communication Engineering, University of Science and Technology Beijing, Beijing 100083, China
3 shared publications - Kai Wu
School of Computer and Communication Engineering, University of Science and Technology Beijing, Beijing 100083, China
2 shared publications Kailai Zhang
Department of Networks China Mobile Communications Group Co, Ltd Beijing China
2 shared publications- Ning Zhang
University of Science and Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing, Beijing, 100083, CHINA
2 shared publications
Latest Publications
- Open Access
- 17 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (12) , 2697
Causal-Driven Severity Grading for Myocardial Ischemia Diagnosis Based on Magnetocardiography
Magnetocardiography (MCG) is currently a promising technique for non-invasive diagnosis of myocardial ischemia. Clinicians can evaluate the degree of ischemia and categorize subjects into three groups: mild ischemia, severe ischemia, and healthy individuals, by examining the spatiotemporal evolution of cardiac magnetic three-field maps. However, the complex spatiotemporal dynamics of MCG data make it challenging for a single modality to characterize ischemia severity. Consequently, we propose a causal-driven multimodal fusion framework that integrates handcrafted key features with MCG image representations. This framework systematically models two types of confounders using a Structural Causal Model (SCM), namely latent visual confounders and cross-modal fusion confounders. To mitigate spurious correlations and feature redundancy during representation learning, we design two causal-inspired modules based on front-door adjustment and counterfactual intervention. Experimental results on our dataset demonstrate the effectiveness of the proposed framework in improving MCG-based ischemia severity grading.
- 17 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (12) , 2697
Open AccessCausal-Driven Severity Grading for Myocardial Ischemia Diagnosis Based on Magnetocardiography
Magnetocardiography (MCG) is currently a promising technique for non-invasive diagnosis of myocardial ischemia. Clinicians can evaluate the degree of ischemia and categorize subjects into three groups: mild ischemia, severe ischemia, and healthy individuals, by examining the spatiotemporal evolution of cardiac magnetic three-field maps. However, the complex spatiotemporal dynamics of MCG data make it challenging for a single modality to characterize ischemia severity. Consequently, we propose a causal-driven multimodal fusion framework that integrates handcrafted key features with MCG image representations. This framework systematically models two types of confounders using a Structural Causal Model (SCM), namely latent visual confounders and cross-modal fusion confounders. To mitigate spurious correlations and feature redundancy during representation learning, we design two causal-inspired modules based on front-door adjustment and counterfactual intervention. Experimental results on our dataset demonstrate the effectiveness of the proposed framework in improving MCG-based ischemia severity grading.
- Open Access
- 20 February 2026
- Published by MDPI AG in Electronics
- Vol. 15 (4) , 886
Delving into Unreliable Pseudo-Labels for Semi-Supervised Medical Image Segmentation via Conformal Selection
Semi-supervised medical image segmentation has recently achieved great success, but assigning trustworthy pseudo-labels to unlabeled images has been a difficult problem in medical image processing. A common solution is to select reliable predicted pixels as the pseudo-labels. However, unreliable pixels are often concentrated in the edge areas of the foreground and background in medical tasks. Directly discarding these pixels will result in this important information never being available. The foreground of medical images is usually surrounded by the edge area. This section of pixels is a mixture of the two categories, which makes it very difficult to distinguish. To address these problems, we propose a semi-supervised medical segmentation framework that combines conformal prediction and contrastive learning. Our framework can use conformal prediction to select pseudo-labels with high confidence and preserve important boundary information. Furthermore, the segmentation performance of edge regions can be improved using contrastive learning between edge categories and non-edge categories. Extensive experiments on multiple benchmarks show that our framework consistently outperforms state-of-the-art methods.
- 20 February 2026
- Published by MDPI AG in Electronics
- Vol. 15 (4) , 886
Open AccessDelving into Unreliable Pseudo-Labels for Semi-Supervised Medical Image Segmentation via Conformal Selection
Semi-supervised medical image segmentation has recently achieved great success, but assigning trustworthy pseudo-labels to unlabeled images has been a difficult problem in medical image processing. A common solution is to select reliable predicted pixels as the pseudo-labels. However, unreliable pixels are often concentrated in the edge areas of the foreground and background in medical tasks. Directly discarding these pixels will result in this important information never being available. The foreground of medical images is usually surrounded by the edge area. This section of pixels is a mixture of the two categories, which makes it very difficult to distinguish. To address these problems, we propose a semi-supervised medical segmentation framework that combines conformal prediction and contrastive learning. Our framework can use conformal prediction to select pseudo-labels with high confidence and preserve important boundary information. Furthermore, the segmentation performance of edge regions can be improved using contrastive learning between edge categories and non-edge categories. Extensive experiments on multiple benchmarks show that our framework consistently outperforms state-of-the-art methods.
- 16 October 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (20) , 205018
MODD: multicenter one-shot medical landmark detection and denoising
Objective. One-shot landmark detection on lateral cephalometric x-ray images has advantages for label-efficient training. As clinical datasets are typically small and do not generalize well to variations in equipment or imaging environments. When using datasets from multiple studies (multi-center data) for joint training, the imbalance in the number of images and the differences in image properties can lead to poor generalization performance. In this work, we aim to propose a method that leverages more data from multiple experiments to improve the accuracy of a single experiment. Approach. To address these challenges, we propose a multicenter one-shot landmark detection and denoising framework (MODD). It incorporates a self-supervised one-shot mapping based on multicenter template transformation and the pseudo-label denoising module. Label denoising is used to reduce the impact of inaccurate pseudo-labels on the algorithm, focusing on label quality rather than signal noise in x-ray images. For denoising module, we propose the shuffled dynamic sample selection and contrastive correction of multicenter pseudo labels. These two components together enable more accurate one-shot landmarks detection on lateral cephalometric x-ray images in multicenter scenarios. Main results. Experiments are conducted with the publicly available multicenter cephalometric x-ray datasets. MODD achieves a landmark detection accuracy of 79.27% within a 4.0 mm range and the mean radial error of 2.94 mm, demonstrating satisfactory performance compared to state-of-the-art methods. Significance. This study expands the application of medical landmark detection to the multi-center one-shot filed and demonstrates the potential of the MODD architecture.
- 16 October 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (20) , 205018
MODD: multicenter one-shot medical landmark detection and denoising
Objective. One-shot landmark detection on lateral cephalometric x-ray images has advantages for label-efficient training. As clinical datasets are typically small and do not generalize well to variations in equipment or imaging environments. When using datasets from multiple studies (multi-center data) for joint training, the imbalance in the number of images and the differences in image properties can lead to poor generalization performance. In this work, we aim to propose a method that leverages more data from multiple experiments to improve the accuracy of a single experiment. Approach. To address these challenges, we propose a multicenter one-shot landmark detection and denoising framework (MODD). It incorporates a self-supervised one-shot mapping based on multicenter template transformation and the pseudo-label denoising module. Label denoising is used to reduce the impact of inaccurate pseudo-labels on the algorithm, focusing on label quality rather than signal noise in x-ray images. For denoising module, we propose the shuffled dynamic sample selection and contrastive correction of multicenter pseudo labels. These two components together enable more accurate one-shot landmarks detection on lateral cephalometric x-ray images in multicenter scenarios. Main results. Experiments are conducted with the publicly available multicenter cephalometric x-ray datasets. MODD achieves a landmark detection accuracy of 79.27% within a 4.0 mm range and the mean radial error of 2.94 mm, demonstrating satisfactory performance compared to state-of-the-art methods. Significance. This study expands the application of medical landmark detection to the multi-center one-shot filed and demonstrates the potential of the MODD architecture.
- Top Cited PapersOpen Access
- 17 June 2025
- Published by MDPI AG in Electronics
- Vol. 14 (12) , 2463
Application Status, Challenges, and Development Prospects of Smart Technologies in Home-Based Elder Care
The rapid growth of China’s aging population has made elderly care a pressing social issue. Due to an imperfect pension system, limited uptake of institutional care, and uneven regional economic development, most elderly people in China still rely on home-based care. Elderly people living at home are usually cared for by their family, partners, caregivers, or themselves. However, this often fails to meet their complex health, safety, and emotional needs. Artificial intelligence may provide promising solutions to improve home care experiences and address the multifaceted health and lifestyle challenges faced by homebound elderly people. This review explores the applications of artificial intelligence in home-based care from four main perspectives: home health care, home safety and security, smart life assistants, and psychological care and emotional support. We systematically searched PubMed, IEEE Xplore, CNKI, and Scopus databases, integrated the latest research published between 2015 and 2024, focused on peer-reviewed, practice-oriented research, and reviewed relevant technology development paths and the current status of the field. Unlike previous studies that focused on physiological monitoring, this study is the first to systematically and comprehensively evaluate the role of artificial intelligence in improving the convenience of daily life and mental health support for elderly people at home. By comprehensively reviewing and analyzing the basic principles and application background of artificial intelligence technology in this field, we summarize the current technical and ethical challenges and propose future research directions. This study aims to help readers gain a deeper understanding of the current status and emerging trends of artificial intelligence-enabled home-based elderly care, thereby providing valuable insights for continued innovation and application in this rapidly developing field.
- 17 June 2025
- Published by MDPI AG in Electronics
- Vol. 14 (12) , 2463
Top Cited PapersOpen AccessApplication Status, Challenges, and Development Prospects of Smart Technologies in Home-Based Elder Care
The rapid growth of China’s aging population has made elderly care a pressing social issue. Due to an imperfect pension system, limited uptake of institutional care, and uneven regional economic development, most elderly people in China still rely on home-based care. Elderly people living at home are usually cared for by their family, partners, caregivers, or themselves. However, this often fails to meet their complex health, safety, and emotional needs. Artificial intelligence may provide promising solutions to improve home care experiences and address the multifaceted health and lifestyle challenges faced by homebound elderly people. This review explores the applications of artificial intelligence in home-based care from four main perspectives: home health care, home safety and security, smart life assistants, and psychological care and emotional support. We systematically searched PubMed, IEEE Xplore, CNKI, and Scopus databases, integrated the latest research published between 2015 and 2024, focused on peer-reviewed, practice-oriented research, and reviewed relevant technology development paths and the current status of the field. Unlike previous studies that focused on physiological monitoring, this study is the first to systematically and comprehensively evaluate the role of artificial intelligence in improving the convenience of daily life and mental health support for elderly people at home. By comprehensively reviewing and analyzing the basic principles and application background of artificial intelligence technology in this field, we summarize the current technical and ethical challenges and propose future research directions. This study aims to help readers gain a deeper understanding of the current status and emerging trends of artificial intelligence-enabled home-based elderly care, thereby providing valuable insights for continued innovation and application in this rapidly developing field.
- 26 August 2024
- Published by Wiley in Concurrency and Computation: Practice and Experience
- Vol. 36 (25)
Noise‐robust neural networks for medical image segmentation by dual‐strategy sample selection
Summary: Deep neural networks for medical image segmentation often face the problem of insufficient clean labeled data. Although non‐expert annotations are more readily accessible, these low‐quality annotations lead to significant performance degradation of existing neural network methods. In this paper, we focus on robust learning of medical image segmentation with noisy annotations and propose a novel noise‐tolerant framework based on dual‐strategy sample selection, which selects the informative samples to provide effective supervision information. First, we propose the first round of sample selection by designing a novel joint loss, which includes conventional supervised loss and regularization loss. To further select information‐rich samples, we propose confidence‐based pseudo‐label sample selection from a novel perspective as the complement. The dual strategies are used in a collaborative manner and the network is optimized with mined informative samples. We conducted extensive experiments on datasets with both simulated noisy labels and real‐world noisy labels. For instance, on a simulated dataset with 25% noise ratio, our method achieves segmentation Dice value with 90.56% 0.03%. Furthermore, increasing the noise ratio to 95%, our method still maintains a high Dice value of 73.85% 0.28% compared to other baselines. Extensive results have demonstrated that our method can weaken the effects of noisy labels on medical image segmentation.
- 26 August 2024
- Published by Wiley in Concurrency and Computation: Practice and Experience
- Vol. 36 (25)
Noise‐robust neural networks for medical image segmentation by dual‐strategy sample selection
Summary: Deep neural networks for medical image segmentation often face the problem of insufficient clean labeled data. Although non‐expert annotations are more readily accessible, these low‐quality annotations lead to significant performance degradation of existing neural network methods. In this paper, we focus on robust learning of medical image segmentation with noisy annotations and propose a novel noise‐tolerant framework based on dual‐strategy sample selection, which selects the informative samples to provide effective supervision information. First, we propose the first round of sample selection by designing a novel joint loss, which includes conventional supervised loss and regularization loss. To further select information‐rich samples, we propose confidence‐based pseudo‐label sample selection from a novel perspective as the complement. The dual strategies are used in a collaborative manner and the network is optimized with mined informative samples. We conducted extensive experiments on datasets with both simulated noisy labels and real‐world noisy labels. For instance, on a simulated dataset with 25% noise ratio, our method achieves segmentation Dice value with 90.56% 0.03%. Furthermore, increasing the noise ratio to 95%, our method still maintains a high Dice value of 73.85% 0.28% compared to other baselines. Extensive results have demonstrated that our method can weaken the effects of noisy labels on medical image segmentation.
- Top Cited Papers
- 12 April 2024
- Published by Elsevier in Medical Image Analysis
- Vol. 95, 103166
A survey of label-noise deep learning for medical image analysis
- 12 April 2024
- Published by Elsevier in Medical Image Analysis
- Vol. 95, 103166
Top Cited PapersA survey of label-noise deep learning for medical image analysis
- Open Access
- 26 January 2022
- Published by MDPI AG in Future Internet
- Vol. 14 (2) , 41
A Hybrid Robust-Learning Architecture for Medical Image Segmentation with Noisy Labels
Deep-learning models require large amounts of accurately labeled data. However, for medical image segmentation, high-quality labels rely on expert experience, and less-experienced operators provide noisy labels. How one might mitigate the negative effects caused by noisy labels for 3D medical image segmentation has not been fully investigated. In this paper, our purpose is to propose a novel hybrid robust-learning architecture to combat noisy labels for 3D medical image segmentation. Our method consists of three components. First, we focus on the noisy annotations of slices and propose a slice-level label-quality awareness method, which automatically generates label-quality scores for slices in a set. Second, we propose a shape-awareness regularization loss based on distance transform maps to introduce prior shape information and provide extra performance gains. Third, based on a re-weighting strategy, we propose an end-to-end hybrid robust-learning architecture to weaken the negative effects caused by noisy labels. Extensive experiments are performed on two representative datasets (i.e., liver segmentation and multi-organ segmentation). Our hybrid noise-robust architecture has shown competitive performance, compared to other methods. Ablation studies also demonstrate the effectiveness of slice-level label-quality awareness and a shape-awareness regularization loss for combating noisy labels.
- 26 January 2022
- Published by MDPI AG in Future Internet
- Vol. 14 (2) , 41
Open AccessA Hybrid Robust-Learning Architecture for Medical Image Segmentation with Noisy Labels
Deep-learning models require large amounts of accurately labeled data. However, for medical image segmentation, high-quality labels rely on expert experience, and less-experienced operators provide noisy labels. How one might mitigate the negative effects caused by noisy labels for 3D medical image segmentation has not been fully investigated. In this paper, our purpose is to propose a novel hybrid robust-learning architecture to combat noisy labels for 3D medical image segmentation. Our method consists of three components. First, we focus on the noisy annotations of slices and propose a slice-level label-quality awareness method, which automatically generates label-quality scores for slices in a set. Second, we propose a shape-awareness regularization loss based on distance transform maps to introduce prior shape information and provide extra performance gains. Third, based on a re-weighting strategy, we propose an end-to-end hybrid robust-learning architecture to weaken the negative effects caused by noisy labels. Extensive experiments are performed on two representative datasets (i.e., liver segmentation and multi-organ segmentation). Our hybrid noise-robust architecture has shown competitive performance, compared to other methods. Ablation studies also demonstrate the effectiveness of slice-level label-quality awareness and a shape-awareness regularization loss for combating noisy labels.
- 21 September 2021
- Published by Springer Nature
- p. 668-677
Distilling Effective Supervision for Robust Medical Image Segmentation with Noisy Labels
- 21 September 2021
- Published by Springer Nature
- p. 668-677
Distilling Effective Supervision for Robust Medical Image Segmentation with Noisy Labels
- 12 May 2021
- Published by Springer Nature in Applied Intelligence
- Vol. 52 (1) , 875-888
Meta joint optimization: a holistic framework for noisy-labeled visual recognition
- 12 May 2021
- Published by Springer Nature in Applied Intelligence
- Vol. 52 (1) , 875-888
Meta joint optimization: a holistic framework for noisy-labeled visual recognition
- 27 April 2021
- Published by Wiley in Medical Physics
- Vol. 48 (7) , 3968-3981
Automatic clinical target volume delineation for cervical cancer in CT images using deep learning
Purpose: Accurately delineating clinical target volumes (CTV) is essential for completing radiotherapy plans but is time‐consuming, labor‐intensive, and prone to inter‐observer variation. Automating CTV delineation has the benefits of both speeding up contouring process and improving the quality of contours. Recently, auto‐segmentation approaches based on deep learning have achieved some improvements. However, unlike organ segmentation, the CTV contains potential tumor spread tissues or subclinical disease tissues, resulting in poorly defined margin interface and irregular shape. It is not reasonable to directly apply the deep learning segmentation algorithms to CTV tasks without considering the unique characteristics of shape and margin. In this work, we propose a novel automatic CTV delineation algorithm based on deep learning addressing the unique shape and margin challenges.Methods: Our deep learning method, called RA‐CTVNet, segments the CTV from cervical cancer CT images. RA‐CTVNet denotes our automatic CTV delineation algorithm based on deep learning with Area‐aware reweight strategy and Recursive refinement strategy. (1) In order to process the whole‐volume CT images and delineate all CTVs in one shot, our method is built upon the popular 3D Unet architecture. We further extend it with robust residual learning and squeeze‐and‐excitation blocks for better feature representation. (2) We propose area‐aware reweight strategy which assigns different weights for different slices. The core is adjusting model’s attention to each slice. (3) In terms of the trade‐off between providing performance improvements and meeting the limitations of GPU memory, we exploit a new recursive refinement strategy to address margin challenge.Results: This retrospective study included 462 patients diagnosed with cervical cancer who received radiotherapy from June 2017 to May 2019. Extensive experiments were conducted to evaluate performance of RA‐CTVNet. First, compared to different network architectures, RA‐CTVNet achieved improvements in Dice similarity coefficient (DSC). Second, we conducted ablation study. The results showed that compared to the backbone, area‐aware reweight strategy increased DSC by 3.3% on average and recursive refinement strategy further increased DSC by 1.6% on average. Then, we compared our method with three human experts. Our RA‐CTVNet performed better than two experts while comparably to the third expert. Finally, a multicenter evaluation was conducted to verify the accuracy and generalizability.Conclusions: Our findings show that deep learning is able to offer an efficient framework for automatic CTV delineation. The tailored RA‐CTVNet can improve the quality of CTV contours, which has great potential for reducing the burden of experts and increasing the accuracy of delineation. In the future, if with more training data, further improvements are possible, bringing this approach closer to real clinical practice.
- 27 April 2021
- Published by Wiley in Medical Physics
- Vol. 48 (7) , 3968-3981
Automatic clinical target volume delineation for cervical cancer in CT images using deep learning
Purpose: Accurately delineating clinical target volumes (CTV) is essential for completing radiotherapy plans but is time‐consuming, labor‐intensive, and prone to inter‐observer variation. Automating CTV delineation has the benefits of both speeding up contouring process and improving the quality of contours. Recently, auto‐segmentation approaches based on deep learning have achieved some improvements. However, unlike organ segmentation, the CTV contains potential tumor spread tissues or subclinical disease tissues, resulting in poorly defined margin interface and irregular shape. It is not reasonable to directly apply the deep learning segmentation algorithms to CTV tasks without considering the unique characteristics of shape and margin. In this work, we propose a novel automatic CTV delineation algorithm based on deep learning addressing the unique shape and margin challenges.Methods: Our deep learning method, called RA‐CTVNet, segments the CTV from cervical cancer CT images. RA‐CTVNet denotes our automatic CTV delineation algorithm based on deep learning with Area‐aware reweight strategy and Recursive refinement strategy. (1) In order to process the whole‐volume CT images and delineate all CTVs in one shot, our method is built upon the popular 3D Unet architecture. We further extend it with robust residual learning and squeeze‐and‐excitation blocks for better feature representation. (2) We propose area‐aware reweight strategy which assigns different weights for different slices. The core is adjusting model’s attention to each slice. (3) In terms of the trade‐off between providing performance improvements and meeting the limitations of GPU memory, we exploit a new recursive refinement strategy to address margin challenge.Results: This retrospective study included 462 patients diagnosed with cervical cancer who received radiotherapy from June 2017 to May 2019. Extensive experiments were conducted to evaluate performance of RA‐CTVNet. First, compared to different network architectures, RA‐CTVNet achieved improvements in Dice similarity coefficient (DSC). Second, we conducted ablation study. The results showed that compared to the backbone, area‐aware reweight strategy increased DSC by 3.3% on average and recursive refinement strategy further increased DSC by 1.6% on average. Then, we compared our method with three human experts. Our RA‐CTVNet performed better than two experts while comparably to the third expert. Finally, a multicenter evaluation was conducted to verify the accuracy and generalizability.Conclusions: Our findings show that deep learning is able to offer an efficient framework for automatic CTV delineation. The tailored RA‐CTVNet can improve the quality of CTV contours, which has great potential for reducing the burden of experts and increasing the accuracy of delineation. In the future, if with more training data, further improvements are possible, bringing this approach closer to real clinical practice.