CFChristina Frölich Frandsen

Christina Frölich Frandsen

*This is an algorithmically generated author record based on publicly available information.

Christina Frölich Frandsen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Maiken Stilling

    Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital, Herning, Denmark

    3 shared publications
  • Torben Bæk Hansen

    Department of Orthopedics, University Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital, Herning; Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark

    3 shared publications
  • Eva Natalia Glassou

    Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital, Herning, Denmark

    2 shared publications
  • Maiken Stilling

    Aarhus University Hospital

    2 shared publications
  • Torben Baek Hansen

    Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital, Herning, Denmark

    2 shared publications
  • Anne Birgitte Langsted Pedersen

    Department of Medicine, Gødstrup Hospital, Herning, Denmark

    1 shared publication

Latest Publications

  • Open Access

    Improved Physical Function following a Three-Month, Home-Based Resistance Training Program for Fragile Patients with Poor Recovery Years after Femoral Neck Fracture—A Prospective Cohort Study

    by Christina Frølich Frandsen, Inger Mechlenburg, Sara Birch, Lone Lundager, Torben Bæk-Hansen, Maiken Stilling

    Patients sustaining a hip fracture experience reduced function and an increased risk of recurrent falls and institutionalization following surgical treatment. Rehabilitation programs that are feasible for home-based training could improve patient-reported outcomes and physical function while lowering the care need and social dependency of this patient group. In the present study, we designed and tested a home-based resistance training program on a group of patients with a femoral neck fracture (FNF) selected according to their poor post-operative functional recovery following an FNF. The results showed that the training program was feasible to perform for the patients, and after three months of training, the patients’ walking, physical activity, and patient-reported outcome measures improved. The patients were encouraged to continue walking and performing the training program, but twelve months after the FNF, the results were comparable to the baseline. Background: Femoral neck fracture (FNF) is associated with reduced function, often leading to an increased care need and a greater risk of recurrent falls. Thus, rehabilitation should be a priority. The present study investigated the training potential among fragile FNF patients with poor functional performance treated with total hip arthroplasty. Methods: In a prospective cohort study, 32 participants were included based on poor functional recovery following an FNF fracture. The participants completed a three-month, physiotherapy-guided, home-based resistance training program. At the baseline and three-month follow-up, physiotherapists performed functional tests and measured spatiotemporal parameters, muscle strength, and muscle mass. The Oxford hip score (OHS) questionnaire was administered and physical activity measurements were performed at baseline and at three-month and 12-month follow-ups. Results: Walking distance, step length, walking speed, and muscle strength increased at the three-month follow-up (p < 0.05). OHS scores increased from the baseline to the 12-month follow-up. Physical activity after three months showed more time spent standing (p = 0.02) and walks of 5–10 min (p = 0.002) compared to the baseline. At the 12-month follow-up, physical activity was similar to the baseline. Conclusions: Fragile patients with low functional performance following FNF displayed training potential with an improvement in function, strength, and physical activity. However, continued training is necessary in order to maintain the positive effects.


  • Active clinical issues at discharge predict readmission within 30 days and one year following hip fracture surgery

    by Christina Frölich Frandsen, Maiken Stilling, Eva Natalia Glassou, Anne Birgitte Langsted Pedersen, Torben Baek Hansen

    Key summary points Aim To investigate the impact of delay in surgery for medical causes and active clinical issues (ACIs) on 30-day readmission for medical causes after hip fracture surgery. Findings ACIs were associated with readmissions following hip fracture surgery; however, no association between readmissions and reasons for delaying surgery was found. Message Further studies into ACIs and reasons for delaying surgery are warranted to make more tailor-made treatment plans for patients with hip fracture.


  • Malnutrition, poor function and comorbidities predict mortality up to one year after hip fracture: a cohort study of 2800 patients

    by Christina Frölich Frandsen, Eva Natalia Glassou, Maiken Stilling, Torben Baek Hansen

    Key summary points AbstractSection Aim To examine the association of 19 risk factors with mortality among patients with hip fracture treated according to a well-defined guideline focusing on risk factors that can be optimised. AbstractSection Findings Age, gender, residence, cognitive function, comorbidities, nutritional status, functional level and mobilisation were all associated with mortality at 30 days and one year. AbstractSection Message The present study supports the efforts of orthogeriatric care in optimising risk factors such as comorbidities, malnutrition and in-hospital rehabilitation. Future studies exploring how and when optimisation should be implemented are warranted.


  • Open Access

    Poor adherence to guidelines in treatment of fragile and cognitively impaired patients with hip fracture: a descriptive study of 2,804 patients

    by Christina F Frandsen, Eva N Glassou, Maiken Stilling, Torben B Hansen

    Background and purpose — Following a hip fracture, most patients will encounter poorer functional outcomes and an increased risk of death. Treatment-monitoring of hip frac- ture patients is in many countries done by national audits. However, they do not allow for a deeper understanding of treatment limitations. We performed a local evaluation study to investigate adherence to 7 best-practice indicators, and to investigate patient groups at risk of suboptimal treatment. Patients and methods — 2,804 patients were surgically treated for a hip fracture from 2011 to 2017 at our institution. Data regarding admission, hospital stay, and discharge was prospectively collected, and adherence to the 7 best practice indicators (nerve block, surgical delay, antibiotics, implant choice, thromboprophylaxis, mobilization, and blood trans- fusions) was analyzed. Patient groups with lower adherence were identified. Results — 34% of patients received all 7 best practice indicators after considering contraindications; in particular, nerve blocks and thromboprophylaxis displayed low adher- ence at 61% and 91% respectively. Nursing home residents and patients with cognitive impairment, multiple comorbidi- ties, or low functional levels were at risk of having a lower adherence. Interpretation — The most dependent patients with cog- nitive impairment, comorbidities, or low functional levels had lower guideline adherence. This large patient subgroup needs a higher treatment focus and more resources. Our find- ings are likely similar to those in other national and interna- tional institutions.


  • Higher UHMWPE wear-rate in cementless compared with cemented cups with the Saturne® Dual-Mobility acetabular system

    by Steffan Tabori-Jensen, Christina Frølich, Torben B. Hansen, Søren Bøvling, Morten Homilius, Maiken Stilling

    Introduction: Dual mobility (DM) total hip arthroplasty (THA) may reduce dislocation risk, but might increase the risk of high polyethylene (PE) wear due to double wearing surfaces. Methods: 127 patients (97 female) with 129 hips operated with THA after displaced femoral neck fracture FNF between 2005 and 2011, were seen for a cross-sectional clinical follow-up. Acetabular components were Saturne® DM cups with 28mm chrome-cobalt heads in UHMWPE. Cementless cups (n = 73) were hydroxyapatite coated. Radiographs were obtained for analysis of cup placement, 2D polyethylene wear and wear-rate (PolyWare 3D), and further radiological evaluation. Activity measurements included Timed Up and Go test (TUG) and walking distance from Harris Hip Score (HHS). Results: At a mean follow-up of 2.83 (1.0-7.7) years the mean wear was 0.82 mm (range 0.17-4.51, SD 0.50), and the wear-rate was 0.37 mm (range 0.06-1.90, SD 0.29). Wear-rate of 0.43 mm/year (SD 0.30) in cementless cups was higher (p = 0.004) than 0.30 mm/year (SD 0.27) in cemented cups. Mean age at time of surgery was 75.1 years (range 30-95). There was no correlation between age at time of surgery and wear (p = 0.56). There was no correlation between cup inclination and wear-rate (p = 0.35). TUG was mean 13.4 seconds (range 4.5-30.1) and correlated with wear rate (p = 0.03). Conclusions: At short term follow-up, the mean wear-rate in old and low demand patients was high, correlated to activity, and was above the generally accepted osteolysis threshold (0.1 mm/yr.). Cementless HA-coated cups had higher wear-rate than cemented cups.


  • Open Access

    Complications Related to Metal-on-Metal Articulation in Trapeziometacarpal Joint Total Joint Arthroplasty

    by Christina Frølich, Torben Bæk Hansen

    Adverse reactions to metal-on-metal (MoM) prostheses are well known from total hip joint resurfacing arthroplasty with elevated serum chrome or cobalt, pain and pseudo tumor formation. It may, however, also be seen after total joint replacement of the trapeziometacarpal joint using MoM articulation, and we present two cases of failure of MoM prostheses due to elevated metal-serum levels in one case and pseudo tumor formation in another case. Furthermore, we suggest a diagnostic algorithm for joint pain after MoM trapeziometacarpal joint replacement based on published experiences from MoM hip prostheses and adverse reactions to metal.