Alfons K. G. Felice
Research Subjects
Alfons K. G. Felice has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Christopher Schulz
DirectSens Biosensors GmbH, Am Rosenbühel 38, 3400 Klosterneuburg, Austria
3 shared publications- Dónal Leech
School of Biological and Chemical Sciences, University of Galway, Ireland
2 shared publications - Eva Melnik
Molecular Diagnostics, AIT Austrian Institute of Technology GmbH, 1210 Vienna, Austria
2 shared publications - Giorgio C. Mutinati
Molecular Diagnostics, AIT Austrian Institute of Technology GmbH, 1210 Vienna, Austria
2 shared publications - Paulina Plata
Competence Unit Molecular Diagnostics, Center for Health & Bioresources, AIT Austrian Institute of Technology GmbH, 1210 Vienna, Austria
2 shared publications Peter L. Herzog
DirectSens GmbH, Muthgasse 11/2, 3. Floor, Vienna 1190, Austria
2 shared publications
Latest Publications
- Open Access
- 22 August 2025
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 1 (10) , 2209-2216
An Oxygen-Insensitive Electrochemical Biosensor for l-Lactate Using a Novel Flavin Mononucleotide-Dependent Lactate Dehydrogenase
- 22 August 2025
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 1 (10) , 2209-2216
Open AccessAn Oxygen-Insensitive Electrochemical Biosensor for l-Lactate Using a Novel Flavin Mononucleotide-Dependent Lactate Dehydrogenase
- Open Access
- 18 September 2024
- Published by Wiley in Advanced Sensor Research
- Vol. 3 (11)
Effects of Sterilization on Cellobiose Dehydrogenase and Glucose Oxidase Based Glucose Biosensors
Research on implantable glucose biosensors is driven by the need for innovative medical devices for continuous glucose monitoring in patients with diabetes mellitus. However, biosensor sterilization is a step that is widely omitted during the process of innovation. To compare the effects of gamma irradiation and chemical treatment with ethylene oxide (carbon microarray electrodes are fabricated, functionalized with glucose oxidizing enzymes (cellobiose dehydrogenase CDH or glucose oxidase GOx), and coated with a specifically designed zwitterionic polymer prior to the sterilization step. Cyclic voltammetry in the presence of 100 mm glucose of the biosensors before and after sterilization shows that gamma irradiation with a low radiation rate (25 kGy, 260 Gy h−1) does not induce a sensor performance loss, unlike the EtO treatment. In addition, no cytotoxic by‐products are released after gamma sterilization. Based on these results obtained with both glucose oxidizing enzymes (CDH and GOx), gamma irradiation of the glucose biosensors with a low dose rate is preferable to exposure to EtO for biosensor terminal sterilization.
- 18 September 2024
- Published by Wiley in Advanced Sensor Research
- Vol. 3 (11)
Open AccessEffects of Sterilization on Cellobiose Dehydrogenase and Glucose Oxidase Based Glucose Biosensors
Research on implantable glucose biosensors is driven by the need for innovative medical devices for continuous glucose monitoring in patients with diabetes mellitus. However, biosensor sterilization is a step that is widely omitted during the process of innovation. To compare the effects of gamma irradiation and chemical treatment with ethylene oxide (carbon microarray electrodes are fabricated, functionalized with glucose oxidizing enzymes (cellobiose dehydrogenase CDH or glucose oxidase GOx), and coated with a specifically designed zwitterionic polymer prior to the sterilization step. Cyclic voltammetry in the presence of 100 mm glucose of the biosensors before and after sterilization shows that gamma irradiation with a low radiation rate (25 kGy, 260 Gy h−1) does not induce a sensor performance loss, unlike the EtO treatment. In addition, no cytotoxic by‐products are released after gamma sterilization. Based on these results obtained with both glucose oxidizing enzymes (CDH and GOx), gamma irradiation of the glucose biosensors with a low dose rate is preferable to exposure to EtO for biosensor terminal sterilization.
- Open Access
- 27 February 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (3) , 36
Novel Approach for the Immobilization of Cellobiose Dehydrogenase in PEDOT:PSS Conductive Layer on Planar Gold Electrodes
Third-generation biosensors use enzymes capable of direct electron transfer (DET) to the sensor surface. They are of interest for continuous glucose monitoring in blood or interstitial fluid, but they are rarely investigated. One reason is the hindered DET of the enzymes to the metallic electrodes. In this publication, a novel method for the immobilization of cellobiose dehydrogenase (CDH) DET enzymes employing conductive poly(3,4-ethylenedioxythiophene)-poly (styrene sulfonate) (PEDOT:PSS) inks and a protective polyethylene glycol dimethacrylate (PEG-DMA) hydrogel layer on gold electrodes is reported. This layer stack showed a glucose-specific current response for voltages between −0.2 and 0.4 V in physiological PBS buffer, and enabled interference-less sensing in a solution of acetaminophen, ascorbic acid, dopamine, and uric acid at 0 V. A Michaelis–Menten fit led to a maximum current density (Imax) of 257 ± 7.9 nA/mm2 and a Michaelis–Menten constant (Km) of 28.4 ± 2.2 mM, with a dynamic range of 0.1–20 mM glucose and a limit of detection of 0.1 mM. After 16 h of continuous measurement of 20 mM glucose, the signal decreased to 60% of its initial value. Storage stability was successfully verified until up to 10 days. In summary, this paper shows a simplified approach for the fabrication of third-generation biosensors using CDH-PEDOT:PSS and PEG-DMA hydrogel inks.
- 27 February 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (3) , 36
Open AccessNovel Approach for the Immobilization of Cellobiose Dehydrogenase in PEDOT:PSS Conductive Layer on Planar Gold Electrodes
Third-generation biosensors use enzymes capable of direct electron transfer (DET) to the sensor surface. They are of interest for continuous glucose monitoring in blood or interstitial fluid, but they are rarely investigated. One reason is the hindered DET of the enzymes to the metallic electrodes. In this publication, a novel method for the immobilization of cellobiose dehydrogenase (CDH) DET enzymes employing conductive poly(3,4-ethylenedioxythiophene)-poly (styrene sulfonate) (PEDOT:PSS) inks and a protective polyethylene glycol dimethacrylate (PEG-DMA) hydrogel layer on gold electrodes is reported. This layer stack showed a glucose-specific current response for voltages between −0.2 and 0.4 V in physiological PBS buffer, and enabled interference-less sensing in a solution of acetaminophen, ascorbic acid, dopamine, and uric acid at 0 V. A Michaelis–Menten fit led to a maximum current density (Imax) of 257 ± 7.9 nA/mm2 and a Michaelis–Menten constant (Km) of 28.4 ± 2.2 mM, with a dynamic range of 0.1–20 mM glucose and a limit of detection of 0.1 mM. After 16 h of continuous measurement of 20 mM glucose, the signal decreased to 60% of its initial value. Storage stability was successfully verified until up to 10 days. In summary, this paper shows a simplified approach for the fabrication of third-generation biosensors using CDH-PEDOT:PSS and PEG-DMA hydrogel inks.
- Open Access
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (9) , 1-4
Detection of Lactate via Amperometric Sensors Modified With Direct Electron Transfer Enzyme Containing PEDOT:PSS and Hydrogel Inks
We present amperometric sensors based on direct electron transfer enzyme (DET) for the detection of lactate, which is an important medical parameter present in blood and interstitial dermal fluid (ISF). For measurement in blood, we present aplanar screen-printedbiosensor withcarbon working electrodes, whilefor the intendedmeasurement in ISF, we investigated platinum-metallized epoxy microneedle sensors. On both sensor types a bioink was applied, consisting of a DET enzyme mixed with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). As second layer, a hydrogel layer is deposited to hold the enzyme on site. Local modification of the platinum microneedle sensors was performed by non-contact spotting. The developed modification enables the detection of lactate at a potential of 0 V with response times of 500-700 s. For carbon sensors, a limit of detection of 0.12 mM lactate was determined, and two linear ranges of 0.3-5 mM and 10-50 mM were observed with sensitivities of 319 and 9.6 nA/(mm2·mM), respectively. For locally modified platinum microneedle sensors two linear ranges of 0.3-2.5 mM and 5-30.5 mM were observed with sensitivities of 322.5 and 3.7 nA/(mm 2 ·mM), respectively. Given the low sensitivities in the higher concentration range, saturation for carbon sensors and locally modified platinum microneedle sensors starts at 10 mM and 5 mM lactate, respectively. Thus, both sensors allow sensitive measurements in the lower concentration range. Current densities at saturating lactate concentration are higher on freshly prepared carbon electrodes with 1.80 μA/mm 2 (10 mM) compared to platinum microneedle electrodes with 0.75 μA/mm 2 (10 mM) with full electrode modification. For platinum microneedle electrodes with optimized, dried local microneedle modification a current density of 0.95 μA/mm2 (5 mM) was measured. Detection of lactate in whole blood was demonstrated on carbon sensors, showing increasing currents after exercise, correlating with higher blood lactate levels, measured with a test strip reference system.
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (9) , 1-4
Open AccessDetection of Lactate via Amperometric Sensors Modified With Direct Electron Transfer Enzyme Containing PEDOT:PSS and Hydrogel Inks
We present amperometric sensors based on direct electron transfer enzyme (DET) for the detection of lactate, which is an important medical parameter present in blood and interstitial dermal fluid (ISF). For measurement in blood, we present aplanar screen-printedbiosensor withcarbon working electrodes, whilefor the intendedmeasurement in ISF, we investigated platinum-metallized epoxy microneedle sensors. On both sensor types a bioink was applied, consisting of a DET enzyme mixed with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). As second layer, a hydrogel layer is deposited to hold the enzyme on site. Local modification of the platinum microneedle sensors was performed by non-contact spotting. The developed modification enables the detection of lactate at a potential of 0 V with response times of 500-700 s. For carbon sensors, a limit of detection of 0.12 mM lactate was determined, and two linear ranges of 0.3-5 mM and 10-50 mM were observed with sensitivities of 319 and 9.6 nA/(mm2·mM), respectively. For locally modified platinum microneedle sensors two linear ranges of 0.3-2.5 mM and 5-30.5 mM were observed with sensitivities of 322.5 and 3.7 nA/(mm 2 ·mM), respectively. Given the low sensitivities in the higher concentration range, saturation for carbon sensors and locally modified platinum microneedle sensors starts at 10 mM and 5 mM lactate, respectively. Thus, both sensors allow sensitive measurements in the lower concentration range. Current densities at saturating lactate concentration are higher on freshly prepared carbon electrodes with 1.80 μA/mm 2 (10 mM) compared to platinum microneedle electrodes with 0.75 μA/mm 2 (10 mM) with full electrode modification. For platinum microneedle electrodes with optimized, dried local microneedle modification a current density of 0.95 μA/mm2 (5 mM) was measured. Detection of lactate in whole blood was demonstrated on carbon sensors, showing increasing currents after exercise, correlating with higher blood lactate levels, measured with a test strip reference system.
- Open Access
- 27 March 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (4) , 1639-1647
Continuous Measurement of Lactate Concentration in Human Subjects through Direct Electron Transfer from Enzymes to Microneedle Electrodes
- 27 March 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (4) , 1639-1647
Open AccessContinuous Measurement of Lactate Concentration in Human Subjects through Direct Electron Transfer from Enzymes to Microneedle Electrodes
- Open Access
- 12 May 2021
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 9 (20) , 7086-7100
Engineering the Turnover Stability of Cellobiose Dehydrogenase toward Long-Term Bioelectronic Applications
- 12 May 2021
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 9 (20) , 7086-7100
Open AccessEngineering the Turnover Stability of Cellobiose Dehydrogenase toward Long-Term Bioelectronic Applications