Hanchi Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hanchi Zhang has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Filipe Faria da Silva
Department of Energy, Aalborg University, Aalborg, Denmark
6 shared publications - Claus Leth Bak
Department of Energy, Aalborg University, Aalborg, Denmark
3 shared publications - Kai Yin
College of Electrical Engineering, Zhejiang University, Hangzhou, China
3 shared publications - Qian Wang
School of Automation, Wuhan University of Technology, Wuhan 430070, China
3 shared publications - Birgitte Bak-Jensen
Department of Energy, Aalborg University, 9220 Aalborg, Denmark
2 shared publications Claus Leth Bak
Aalborg Univ, AAU Energy, Aalborg, Denmark
2 shared publications
Latest Publications
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Sampling-Rate Enhancement of φ-OTDR Systems for Acoustic Emission Detection of Partial Discharges in GIS
Acoustic emission (AE) detection methods based on phase-sensitive optical time-domain reflectometry (φ-OTDR) have shown strong potential for partial-discharge (PD) detection in gas-insulated switchgear (GIS). However, an inherent trade-off between the sensing fiber length and the system sampling rate restricts the detection of high-frequency PD acoustic signals. To overcome this limitation, a φ-OTDR system incorporating an auxiliary fiber loop is developed to increase the effective sampling rate without sacrificing the sensing range. In this configuration, each periodically injected probe pulse serves as a temporal seed, undergoing a fixed frequency shift during each loop circulation and forming a probe pulse sequence with periodic and equally spaced frequency offsets and enabling frequency-multiplexed Rayleigh backscattering interrogation. This multiplexing substantially increases the sampling rate of AE signals by raising the equivalent probepulse repetition rate. Experiments on a practical 110 kV GIS demonstrate that the developed system achieves an effective acoustic-signal sampling rate of 800 kHz, enabling distributed sensing at 24 sensing points. Metallic particle PD defects are successfully detected and localized, with a signal-to-noise ratio approximately 4 dB higher than that of a conventional piezoelectric transducer. These results demonstrate the effectiveness of the proposed system for high-frequency distributed AE detection in GIS PD monitoring.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Sampling-Rate Enhancement of φ-OTDR Systems for Acoustic Emission Detection of Partial Discharges in GIS
Acoustic emission (AE) detection methods based on phase-sensitive optical time-domain reflectometry (φ-OTDR) have shown strong potential for partial-discharge (PD) detection in gas-insulated switchgear (GIS). However, an inherent trade-off between the sensing fiber length and the system sampling rate restricts the detection of high-frequency PD acoustic signals. To overcome this limitation, a φ-OTDR system incorporating an auxiliary fiber loop is developed to increase the effective sampling rate without sacrificing the sensing range. In this configuration, each periodically injected probe pulse serves as a temporal seed, undergoing a fixed frequency shift during each loop circulation and forming a probe pulse sequence with periodic and equally spaced frequency offsets and enabling frequency-multiplexed Rayleigh backscattering interrogation. This multiplexing substantially increases the sampling rate of AE signals by raising the equivalent probepulse repetition rate. Experiments on a practical 110 kV GIS demonstrate that the developed system achieves an effective acoustic-signal sampling rate of 800 kHz, enabling distributed sensing at 24 sensing points. Metallic particle PD defects are successfully detected and localized, with a signal-to-noise ratio approximately 4 dB higher than that of a conventional piezoelectric transducer. These results demonstrate the effectiveness of the proposed system for high-frequency distributed AE detection in GIS PD monitoring.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (6) , 3085-3097
Modeling Electric Spark Discharges on Drones in Contact With High-Voltage Power Lines and Lab Equivalent Tests
The use of drones for inspecting and maintaining high-voltage transmission lines has become increasingly popular, replacing traditional methods like helicopters and cranes. However, the potential difference between the drone and the high-voltage cable results in the occurrence of electric sparks striking the drone during its interaction with the power cable to perform tasks. This paper models the arcing phenomenon to predict spark current levels and repetition rates at any power line voltages and distances. Lab experiments at voltages up to 100 kV AC were conducted to validate the model, showing an accuracy range of 3.6% to 23% when considering the peak currents. The results were used to evaluate the interference to a carbon fiber drone in simulation and minimal shield was proposed to reduce the noise. All the proposed models are made available as open-source. Additionally, equivalent lab tests using at least two times lower voltages were introduced to replicate the arcing conditions of real overhead power lines.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (6) , 3085-3097
Modeling Electric Spark Discharges on Drones in Contact With High-Voltage Power Lines and Lab Equivalent Tests
The use of drones for inspecting and maintaining high-voltage transmission lines has become increasingly popular, replacing traditional methods like helicopters and cranes. However, the potential difference between the drone and the high-voltage cable results in the occurrence of electric sparks striking the drone during its interaction with the power cable to perform tasks. This paper models the arcing phenomenon to predict spark current levels and repetition rates at any power line voltages and distances. Lab experiments at voltages up to 100 kV AC were conducted to validate the model, showing an accuracy range of 3.6% to 23% when considering the peak currents. The results were used to evaluate the interference to a carbon fiber drone in simulation and minimal shield was proposed to reduce the noise. All the proposed models are made available as open-source. Additionally, equivalent lab tests using at least two times lower voltages were introduced to replicate the arcing conditions of real overhead power lines.
- Open Access
- 6 June 2025
- Published by Aalborg University
Transient Lightning Impulse Performance Analysis of a Fully Composite Pylon with an External-grounding Down-lead
- 6 June 2025
- Published by Aalborg University
Open AccessTransient Lightning Impulse Performance Analysis of a Fully Composite Pylon with an External-grounding Down-lead
- Open Access
Autonomous Control of Electric Vehicles Using Voltage Droop
The surge in electric vehicles (EVs) in Denmark challenges the country’s residential low-voltage (LV) distribution system. In particular, it increases the demand for home EV charging significantly and possibly overloads the LV grid. This study analyzes the impact of EV charging integration on Denmark’s residential distribution networks. A residential grid comprising 67 households powered by a 630 kVA transformer is studied using DiGSILENT PowerFactory. With the assumption of simultaneous charging of all EVs, the transformer can be heavily loaded up to 147.2%. Thus, a voltage-droop based autonomous control approach is adopted, where the EV charging power is dynamically adjusted based on the point-of-connection voltage of each charger instead of the fixed rated power. This strategy eliminates overloading of the transformers and cables, ensuring they operate within a pre-set limit of 80%. Voltage drops are mitigated within the acceptable safety range of ±10% from normal voltage. These results highlight the effectiveness of the droop control strategy in managing EV charging power. Finally, it exemplifies the benefits of intelligent EV charging systems in Horizon 2020 EU Projects like SERENE and SUSTENANCE. The findings underscore the necessity to integrate smart control mechanisms, consider reinforcing grids, and promote active consumer participation to meet the rising demand for a low-carbon future.
Open AccessAutonomous Control of Electric Vehicles Using Voltage Droop
The surge in electric vehicles (EVs) in Denmark challenges the country’s residential low-voltage (LV) distribution system. In particular, it increases the demand for home EV charging significantly and possibly overloads the LV grid. This study analyzes the impact of EV charging integration on Denmark’s residential distribution networks. A residential grid comprising 67 households powered by a 630 kVA transformer is studied using DiGSILENT PowerFactory. With the assumption of simultaneous charging of all EVs, the transformer can be heavily loaded up to 147.2%. Thus, a voltage-droop based autonomous control approach is adopted, where the EV charging power is dynamically adjusted based on the point-of-connection voltage of each charger instead of the fixed rated power. This strategy eliminates overloading of the transformers and cables, ensuring they operate within a pre-set limit of 80%. Voltage drops are mitigated within the acceptable safety range of ±10% from normal voltage. These results highlight the effectiveness of the droop control strategy in managing EV charging power. Finally, it exemplifies the benefits of intelligent EV charging systems in Horizon 2020 EU Projects like SERENE and SUSTENANCE. The findings underscore the necessity to integrate smart control mechanisms, consider reinforcing grids, and promote active consumer participation to meet the rising demand for a low-carbon future.
- Open Access
- 23 April 2025
- Published by MDPI AG in Preprints.org
Autonomous Control of Electric Vehicles Using Voltage Droop
The surge of electric vehicles (EVs) in Denmark challenges the country’s residential low-voltage (LV) distribution system. Especially, it increases the demand for home EV charging significantly and overload the LV grid possibly. This study analyses the impact of EV charging integration on Denmark's residential distribution networks. A residential grid comprising 67 households powered by a 630 kVA transformer is studied using DiGSILENT PowerFactory. With the assumption of simultaneous charging of all EVs, the transformer can be heavily loaded up to 147.2%. Thus, a voltage-droop based autonomous control approach is adopted, where the EV charging power is dynamically adjusted based on the point-of-connection voltage of each charger instead of fixed rated power. This strategy eliminates overloading of the transformer and cables, ensuring they operate within a pre-set limit of 80%. Voltage drops are mitigated within the acceptable safety range of ±10% from normal voltage. These results highlight the effectiveness of the droop control strategy in managing EV charging power. At last, it exemplifies the benefits of intelligent EV charging systems in Horizon 2020 EU Projects like SERENE and SUSTENANCE. The findings underscore the necessity to integrate smart control mechanisms, consider reinforcing grids, and promote active consumer participation to meet the rising demand for a low-carbon future.
- 23 April 2025
- Published by MDPI AG in Preprints.org
Open AccessAutonomous Control of Electric Vehicles Using Voltage Droop
The surge of electric vehicles (EVs) in Denmark challenges the country’s residential low-voltage (LV) distribution system. Especially, it increases the demand for home EV charging significantly and overload the LV grid possibly. This study analyses the impact of EV charging integration on Denmark's residential distribution networks. A residential grid comprising 67 households powered by a 630 kVA transformer is studied using DiGSILENT PowerFactory. With the assumption of simultaneous charging of all EVs, the transformer can be heavily loaded up to 147.2%. Thus, a voltage-droop based autonomous control approach is adopted, where the EV charging power is dynamically adjusted based on the point-of-connection voltage of each charger instead of fixed rated power. This strategy eliminates overloading of the transformer and cables, ensuring they operate within a pre-set limit of 80%. Voltage drops are mitigated within the acceptable safety range of ±10% from normal voltage. These results highlight the effectiveness of the droop control strategy in managing EV charging power. At last, it exemplifies the benefits of intelligent EV charging systems in Horizon 2020 EU Projects like SERENE and SUSTENANCE. The findings underscore the necessity to integrate smart control mechanisms, consider reinforcing grids, and promote active consumer participation to meet the rising demand for a low-carbon future.
- Open Access
- 19 August 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 237
Coordination of the back flashover probability of HVAC and HVDC on a hybrid transmission tower
- 19 August 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 237
Open AccessCoordination of the back flashover probability of HVAC and HVDC on a hybrid transmission tower
- 31 January 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 217
Feasibility of cable through a hollow cross-arm as down-lead for a 400 kV Y-shaped composite pylon
- 31 January 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 217
Feasibility of cable through a hollow cross-arm as down-lead for a 400 kV Y-shaped composite pylon
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (1) , 420-431
The Design and Optimization of the Down-Lead System for a Novel 400 kV Composite Pylon
This paper presents systematic research of a grounding down-lead design and its optimization for a novel Y-shaped composite pylon. A grounding down-lead inside the cross-arm is proposed as a potential grounding method. The transient response to lightning surges is modeled in PSCAD/EMTDC for a flash of lightning striking at the tip of the pylon. Aiming at the characteristic of the pylon structure, we propose theoretical formulas to calculate the surge impedance of the inclined down-lead circumscribed by composite materials. Besides, potential multi-factors affecting BFR such as the configuration as well as the length of the down-lead, the pylon span, the dielectric constant of the filling material, the electromagnetic propagation speed of the lightning, and the capacitances between down-lead and phase conductors are investigated, after which the grounding lead system of the pylon and filling materials are determined. Afterwards, the applicability of the multi-down-lead system to increase critical current ( Ic ) is discussed considering the lightning current capacity and the corona generation. Finally, we verify the insulation of the down-lead system. Compared with that of traditional Eagle and Donau towers, the backflashover rate (BFR) of the Y-shaped pylon with an optimized down-lead system is lower than that of traditional ones.
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (1) , 420-431
The Design and Optimization of the Down-Lead System for a Novel 400 kV Composite Pylon
This paper presents systematic research of a grounding down-lead design and its optimization for a novel Y-shaped composite pylon. A grounding down-lead inside the cross-arm is proposed as a potential grounding method. The transient response to lightning surges is modeled in PSCAD/EMTDC for a flash of lightning striking at the tip of the pylon. Aiming at the characteristic of the pylon structure, we propose theoretical formulas to calculate the surge impedance of the inclined down-lead circumscribed by composite materials. Besides, potential multi-factors affecting BFR such as the configuration as well as the length of the down-lead, the pylon span, the dielectric constant of the filling material, the electromagnetic propagation speed of the lightning, and the capacitances between down-lead and phase conductors are investigated, after which the grounding lead system of the pylon and filling materials are determined. Afterwards, the applicability of the multi-down-lead system to increase critical current ( Ic ) is discussed considering the lightning current capacity and the corona generation. Finally, we verify the insulation of the down-lead system. Compared with that of traditional Eagle and Donau towers, the backflashover rate (BFR) of the Y-shaped pylon with an optimized down-lead system is lower than that of traditional ones.
- 1 September 2021
- Published by Elsevier in Electric Power Systems Research
- Vol. 198
Integrated model of transmission tower surge impedance and multilayer grounding system based on full-wave approach
- 1 September 2021
- Published by Elsevier in Electric Power Systems Research
- Vol. 198
Integrated model of transmission tower surge impedance and multilayer grounding system based on full-wave approach