Nouman Khattak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nouman Khattak has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Tamer El-Maaddawy
Department of Civil and Environmental Engineering, United Arab Emirates University, Al Ain 15551, United Arab Emirates
5 shared publications - Najif Ismail
Department of Civil and Environmental Engineering, United Arab Emirates University, Al Ain, United Arab Emirates
4 shared publications - David P. Thambiratnam
Queensland University of Technology (QUT)
2 shared publications - Hossein Derakhshan
University of Adelaide, Adelaide, Australia
2 shared publications A. Najmal
Graduate Student, Dept. of Civil and Environmental Engineering, United Arab Emirates Univ., P.O. Box 15551, Al Ain, United Arab Emirates
1 shared publicationAmanullah Najmal
1 shared publication
Latest Publications
- Open Access
- 25 June 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 76
Modelling the in-plane/out-of-plane interaction of brick and stone masonry structures using Applied Element Method
- 25 June 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 76
Open AccessModelling the in-plane/out-of-plane interaction of brick and stone masonry structures using Applied Element Method
- Open Access
Prediction of Nonlinear Flexural Behavior of Continuous RC Beams Pre-Damaged by Corrosion
Numerical simulation models capable of predicting the nonlinear flexural behavior of continuous reinforced concrete (RC) beams with corroded reinforcement were developed. Laboratory tests were conducted to validate predictions of the numerical models. A parametric study was carried out to examine the effect of varying the location and severity of corrosion on the nonlinear flexural behavior of continuous RC beams. The load capacity of continuous RC beams decreased linearly with an increase in the severity of corrosion, regardless of its location. The corrosion of reinforcement in the sagging region was, however, more detrimental to the load capacity than hogging corrosion. The rate of the strength reduction for the beam models with sagging corrosion was approximately 70% higher than that of the models with hogging corrosion. The beam models with sagging and hogging corrosion concurrently exhibited the poorest performance. The rate of the strength reduction of the beam models with corrosion in both sagging and hogging regions was approximately 2.7 times that of the models with hogging corrosion only. The moment redistribution ratio at the ultimate load for the beam models with sagging corrosion only ranged from 2–22%. The beam models with corrosion in the hogging region only exhibited the highest moment redistribution ratio of 22–50% at the ultimate load. The beam models with sagging and hogging corrosion simultaneously exhibited a constant moment redistribution ratio of 18% at the ultimate load.
Open AccessPrediction of Nonlinear Flexural Behavior of Continuous RC Beams Pre-Damaged by Corrosion
Numerical simulation models capable of predicting the nonlinear flexural behavior of continuous reinforced concrete (RC) beams with corroded reinforcement were developed. Laboratory tests were conducted to validate predictions of the numerical models. A parametric study was carried out to examine the effect of varying the location and severity of corrosion on the nonlinear flexural behavior of continuous RC beams. The load capacity of continuous RC beams decreased linearly with an increase in the severity of corrosion, regardless of its location. The corrosion of reinforcement in the sagging region was, however, more detrimental to the load capacity than hogging corrosion. The rate of the strength reduction for the beam models with sagging corrosion was approximately 70% higher than that of the models with hogging corrosion. The beam models with sagging and hogging corrosion concurrently exhibited the poorest performance. The rate of the strength reduction of the beam models with corrosion in both sagging and hogging regions was approximately 2.7 times that of the models with hogging corrosion only. The moment redistribution ratio at the ultimate load for the beam models with sagging corrosion only ranged from 2–22%. The beam models with corrosion in the hogging region only exhibited the highest moment redistribution ratio of 22–50% at the ultimate load. The beam models with sagging and hogging corrosion simultaneously exhibited a constant moment redistribution ratio of 18% at the ultimate load.
- 24 August 2022
- Published by Taylor & Francis in Australian Journal of Structural Engineering
- Vol. 24 (1) , 1-23
Using heritage building registers to characterise unreinforced masonry buildings of Brisbane, Australia
Worldwide, unreinforced masonry (URM) buildings are present in abundance with many holding cultural and heritage value. URM buildings have a known history of poor performance during past earthquakes because of the weak tensile properties and lack of mechanical connections between elements. Information about the construction of URM buildings for a region is important because it can help engineers and policy makers to perform seismic assessment, risk and loss studies. In this regard, this study includes a characterisation of the heritage URM buildings in Brisbane City, Australia, and its surrounding suburbs using the Queensland Heritage Register (QHR). The QHR includes a total of 1775 heritage sites, of which 323 are identified as URM buildings in Brisbane City and surrounding suburbs. The studied building characteristics obtained from QHR included the architectural styles, construction year, function/use, number of storeys, roof material and load-bearing wall materials. Other features such as roof types (shapes), plan geometry, isolated or interconnected buildings, verandas and openings, and finally the presence of seismic hazards such as gable-end walls, chimneys, and parapets have been obtained using online 3D maps. It was concluded that heritage registers in combination with online digital resources can be successfully utilised to characterise URM buildings.
- 24 August 2022
- Published by Taylor & Francis in Australian Journal of Structural Engineering
- Vol. 24 (1) , 1-23
Using heritage building registers to characterise unreinforced masonry buildings of Brisbane, Australia
Worldwide, unreinforced masonry (URM) buildings are present in abundance with many holding cultural and heritage value. URM buildings have a known history of poor performance during past earthquakes because of the weak tensile properties and lack of mechanical connections between elements. Information about the construction of URM buildings for a region is important because it can help engineers and policy makers to perform seismic assessment, risk and loss studies. In this regard, this study includes a characterisation of the heritage URM buildings in Brisbane City, Australia, and its surrounding suburbs using the Queensland Heritage Register (QHR). The QHR includes a total of 1775 heritage sites, of which 323 are identified as URM buildings in Brisbane City and surrounding suburbs. The studied building characteristics obtained from QHR included the architectural styles, construction year, function/use, number of storeys, roof material and load-bearing wall materials. Other features such as roof types (shapes), plan geometry, isolated or interconnected buildings, verandas and openings, and finally the presence of seismic hazards such as gable-end walls, chimneys, and parapets have been obtained using online 3D maps. It was concluded that heritage registers in combination with online digital resources can be successfully utilised to characterise URM buildings.
- Open Access
Continuous Reinforced Concrete Beams Strengthened with Fabric-Reinforced Cementitious Matrix: Experimental Investigation and Numerical Simulation
This paper aims to examine the nonlinear flexural behavior of continuous RC beam specimens strengthened with fabric-reinforced cementitious matrix (FRCM) composites through experimental testing and numerical modeling. A total of nine two-span RC beam specimens were constructed and tested. Test parameters included the type of FRCM (carbon (C-FRCM) and polyparaphenylene benzobisoxazole (PBO-FRCM)), location of strengthening (sagging and hogging regions) and number of FRCM layers (two and four layers). Test results indicated that sagging strengthening resulted in a strength gain in the range of 17 to 29%, whereas hogging strengthening increased the load capacity by 9 to 17%. The use of C-FRCM resulted in a higher strength gain than that provided by PBO-FRCM composites. Specimens strengthened with PBO-FRCM exhibited, however, higher ductility and deformational capacity than those of their counterparts strengthened with C-FRCM. Doubling the number of FRCM layers resulted in no or insignificant increase in the load capacity but reduced the beam ductility. Specimens strengthened in the sagging regions exhibited moment redistribution ratios of 13 to 26% between the hogging and sagging regions. Insignificant moment redistribution was recorded for the specimens strengthened in the hogging region. Three-dimensional (3D) numerical simulation models, with and without an interfacial bond-slip law at the fabric–matrix interface, were developed. The inclusion of the bond-slip law in the modeling had an insignificant effect on predicted response. Although the models tended to underestimate the deflection, the predicted load capacities were within a 12% error band. Numerical findings were in agreement with those obtained from laboratory testing.
Open AccessContinuous Reinforced Concrete Beams Strengthened with Fabric-Reinforced Cementitious Matrix: Experimental Investigation and Numerical Simulation
This paper aims to examine the nonlinear flexural behavior of continuous RC beam specimens strengthened with fabric-reinforced cementitious matrix (FRCM) composites through experimental testing and numerical modeling. A total of nine two-span RC beam specimens were constructed and tested. Test parameters included the type of FRCM (carbon (C-FRCM) and polyparaphenylene benzobisoxazole (PBO-FRCM)), location of strengthening (sagging and hogging regions) and number of FRCM layers (two and four layers). Test results indicated that sagging strengthening resulted in a strength gain in the range of 17 to 29%, whereas hogging strengthening increased the load capacity by 9 to 17%. The use of C-FRCM resulted in a higher strength gain than that provided by PBO-FRCM composites. Specimens strengthened with PBO-FRCM exhibited, however, higher ductility and deformational capacity than those of their counterparts strengthened with C-FRCM. Doubling the number of FRCM layers resulted in no or insignificant increase in the load capacity but reduced the beam ductility. Specimens strengthened in the sagging regions exhibited moment redistribution ratios of 13 to 26% between the hogging and sagging regions. Insignificant moment redistribution was recorded for the specimens strengthened in the hogging region. Three-dimensional (3D) numerical simulation models, with and without an interfacial bond-slip law at the fabric–matrix interface, were developed. The inclusion of the bond-slip law in the modeling had an insignificant effect on predicted response. Although the models tended to underestimate the deflection, the predicted load capacities were within a 12% error band. Numerical findings were in agreement with those obtained from laboratory testing.
- 1 January 2020
- Published by Inderscience Publishers in International Journal of Masonry Research and Innovation
- Vol. 5 (3) , 396-422
Out-of-plane testing of masonry infills strengthened using fibre reinforced matrix with prior in-plane damage
Performance of fibre reinforced cementitious matrix (FRCM) strengthened masonry infills under sequential bi-directional earthquake induced lateral loading, which is far from well-understood, was experimentally investigated herein. A total of eight single bay reinforced concrete frames were constructed with unreinforced hollow concrete masonry infills, of these one was tested non-retrofitted that served as control test assembly and the remainder were strengthened using varying FRCM types and configurations. The test assemblies were subjected to cyclic in-plane loading gradually increasing to 1% story drift, replicating lateral loading due to a moderate earthquake. These already in-plane damaged test assemblies were then subjected to gradually increasing monotonic OOP loading until failure. Resulting damage patterns, failure mechanisms, measured force-displacement response and stiffness characteristics were discussed. FRCM strengthening delayed the onset of out-of-plane cracking, instigated a more controlled failure mode, with strengthened infills exhibiting out-of-plane strength of 1.72.0 times that of the control specimen.
- 1 January 2020
- Published by Inderscience Publishers in International Journal of Masonry Research and Innovation
- Vol. 5 (3) , 396-422
Out-of-plane testing of masonry infills strengthened using fibre reinforced matrix with prior in-plane damage
Performance of fibre reinforced cementitious matrix (FRCM) strengthened masonry infills under sequential bi-directional earthquake induced lateral loading, which is far from well-understood, was experimentally investigated herein. A total of eight single bay reinforced concrete frames were constructed with unreinforced hollow concrete masonry infills, of these one was tested non-retrofitted that served as control test assembly and the remainder were strengthened using varying FRCM types and configurations. The test assemblies were subjected to cyclic in-plane loading gradually increasing to 1% story drift, replicating lateral loading due to a moderate earthquake. These already in-plane damaged test assemblies were then subjected to gradually increasing monotonic OOP loading until failure. Resulting damage patterns, failure mechanisms, measured force-displacement response and stiffness characteristics were discussed. FRCM strengthening delayed the onset of out-of-plane cracking, instigated a more controlled failure mode, with strengthened infills exhibiting out-of-plane strength of 1.72.0 times that of the control specimen.
- 22 April 2019
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 18 (2) , 301-314
Observed failure modes of unreinforced masonry buildings during the 2015 Hindu Kush earthquake
- 22 April 2019
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 18 (2) , 301-314
Observed failure modes of unreinforced masonry buildings during the 2015 Hindu Kush earthquake
- 1 October 2018
- Published by Elsevier in Construction and Building Materials
- Vol. 186, 1286-1298
Quasi-static in-plane testing of FRCM strengthened non-ductile reinforced concrete frames with masonry infills
- 1 October 2018
- Published by Elsevier in Construction and Building Materials
- Vol. 186, 1286-1298
Quasi-static in-plane testing of FRCM strengthened non-ductile reinforced concrete frames with masonry infills
- Open Access
- 30 June 2018
- Published by New Zealand Society for Earthquake Engineering in Bulletin of the New Zealand Society for Earthquake Engineering
- Vol. 51 (2) , 85-91
Experimental in-plane performance of insulated concrete and brick masonry wall panels retrofitted using polymer composites
Masonry infilled reinforced concrete frame buildings built prior to the introduction of modern seismic provisions have been observed to undergo damage in and around the masonry infill walls during most recent moderate to severe earthquakes. Fibre reinforced cementitious matrix (FRCM) is one of several retrofitting options available to limit such earthquake induced damage to infill walls. An experimental program was undertaken herein to experimentally investigate the effectiveness of FRCM as a strengthening solution for vintage (i.e. built between 1880 and 1930) un-reinforced brick masonry (URM) and insulated concrete masonry (IMU) infill walls. A total of 16 masonry assemblages were tested under in-plane diagonal load, of these 8 were constructed replicating vintage URM whereas the remainder were constructed using modern IMU. IMU is a preferred masonry type in hot and humid regions owing to its superior insulting capability. Different polymer fabrics (i.e., carbon, glass and basalt) were applied over both faces of test walls, with two replicate test walls receiving the same FRCM strengthening details. One test wall of each masonry type was tested as-built to serve as a control specimen for comparison. One wall of each masonry type received two layers of basalt FRCM. The investigated aspects included stress-strain behaviour, stiffness, and ductility. Shear strength increment observed due to single layer of FRCM application was 422-778% for vintage URM and 307-415% for modern IMU. FRCM also substantially increased the ductility capacity of the masonry assemblages.
- 30 June 2018
- Published by New Zealand Society for Earthquake Engineering in Bulletin of the New Zealand Society for Earthquake Engineering
- Vol. 51 (2) , 85-91
Open AccessExperimental in-plane performance of insulated concrete and brick masonry wall panels retrofitted using polymer composites
Masonry infilled reinforced concrete frame buildings built prior to the introduction of modern seismic provisions have been observed to undergo damage in and around the masonry infill walls during most recent moderate to severe earthquakes. Fibre reinforced cementitious matrix (FRCM) is one of several retrofitting options available to limit such earthquake induced damage to infill walls. An experimental program was undertaken herein to experimentally investigate the effectiveness of FRCM as a strengthening solution for vintage (i.e. built between 1880 and 1930) un-reinforced brick masonry (URM) and insulated concrete masonry (IMU) infill walls. A total of 16 masonry assemblages were tested under in-plane diagonal load, of these 8 were constructed replicating vintage URM whereas the remainder were constructed using modern IMU. IMU is a preferred masonry type in hot and humid regions owing to its superior insulting capability. Different polymer fabrics (i.e., carbon, glass and basalt) were applied over both faces of test walls, with two replicate test walls receiving the same FRCM strengthening details. One test wall of each masonry type was tested as-built to serve as a control specimen for comparison. One wall of each masonry type received two layers of basalt FRCM. The investigated aspects included stress-strain behaviour, stiffness, and ductility. Shear strength increment observed due to single layer of FRCM application was 422-778% for vintage URM and 307-415% for modern IMU. FRCM also substantially increased the ductility capacity of the masonry assemblages.
- 1 April 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 22 (2)
In-Plane Shear Strength Improvement of Hollow Concrete Masonry Panels Using a Fabric-Reinforced Cementitious Matrix
An overview of an experimental program investigating the effectiveness of fabric-reinforced cementitious matrix (FRCM) to limit the damage in shear critical unreinforced hollow concrete masonry assemblages is presented. The experimental program involved the mechanical testing of the constituent materials and the diagonal shear testing of 16 masonry panels constructed to replicate the masonry types prevalent in nonductile reinforced concrete frames with masonry infill buildings. The test variables investigated included the masonry type, the FRCM fabric material, and the number of FRCM layers. Three FRCM fabrics (basalt, glass, and carbon) and two masonry types (200 and 150 mm thick) were used. The FRCM strengthening changed the failure mode from brittle bed joint sliding to a more gradual distributed diagonal cracking and/or toe crushing, with a shear strength increase of 104–258% for 150-mm thick masonry panels and 69–156% for 200-mm thick masonry panels. A substantial increase in the ductility and energy dissipation capacity was also noted for the FRCM-strengthened masonry panels. The shear stress-strain behavior, deformation capacity, pseudoductility, energy dissipation, and stiffness characteristics were analyzed and discussed. The behavior of the FRCM-strengthened panels was predicted using analytical equations, and the predicted values were compared to the experimental results.
- 1 April 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 22 (2)
In-Plane Shear Strength Improvement of Hollow Concrete Masonry Panels Using a Fabric-Reinforced Cementitious Matrix
An overview of an experimental program investigating the effectiveness of fabric-reinforced cementitious matrix (FRCM) to limit the damage in shear critical unreinforced hollow concrete masonry assemblages is presented. The experimental program involved the mechanical testing of the constituent materials and the diagonal shear testing of 16 masonry panels constructed to replicate the masonry types prevalent in nonductile reinforced concrete frames with masonry infill buildings. The test variables investigated included the masonry type, the FRCM fabric material, and the number of FRCM layers. Three FRCM fabrics (basalt, glass, and carbon) and two masonry types (200 and 150 mm thick) were used. The FRCM strengthening changed the failure mode from brittle bed joint sliding to a more gradual distributed diagonal cracking and/or toe crushing, with a shear strength increase of 104–258% for 150-mm thick masonry panels and 69–156% for 200-mm thick masonry panels. A substantial increase in the ductility and energy dissipation capacity was also noted for the FRCM-strengthened masonry panels. The shear stress-strain behavior, deformation capacity, pseudoductility, energy dissipation, and stiffness characteristics were analyzed and discussed. The behavior of the FRCM-strengthened panels was predicted using analytical equations, and the predicted values were compared to the experimental results.
- 1 November 2016
- Published by Wiley in Earthquake Spectra
- Vol. 32 (4) , 2473-2493
Building Typologies Prevalent in Northern Pakistan and Their Performance during the 2015 Hindu Kush Earthquake
The M7.5 earthquake of 26 October 2015 resulted due to reverse faulting at an intermediate depth of 210 km within the northeast‐trending tabular zone underneath the Hindu Kush region, with its epicenter located 45 km southwest of Jarm in Afghanistan. In Pakistan alone, the earthquake and subsequent aftershock swarm resulted in 280 fatalities, injuries to 1,770 persons, and notable damage to 109,123 buildings. A synopsis of observations is presented herein, covering details about seismotectonics, strong motion characteristics, damage statistics, and typical building failure modes. Building damage was observed to mostly concentrate in vulnerable rural and old unreinforced masonry buildings, with aspects such as complete or partial out of plane collapse of walls, collapse of roofs due to loss of seating, shear cracking in masonry walls/panels, shear and flexural damage in masonry spandrels, cracking at infill‐frame interface, damage at building corners, pounding damage, toppled minarets, and damage due to ground settlement.
- 1 November 2016
- Published by Wiley in Earthquake Spectra
- Vol. 32 (4) , 2473-2493
Building Typologies Prevalent in Northern Pakistan and Their Performance during the 2015 Hindu Kush Earthquake
The M7.5 earthquake of 26 October 2015 resulted due to reverse faulting at an intermediate depth of 210 km within the northeast‐trending tabular zone underneath the Hindu Kush region, with its epicenter located 45 km southwest of Jarm in Afghanistan. In Pakistan alone, the earthquake and subsequent aftershock swarm resulted in 280 fatalities, injuries to 1,770 persons, and notable damage to 109,123 buildings. A synopsis of observations is presented herein, covering details about seismotectonics, strong motion characteristics, damage statistics, and typical building failure modes. Building damage was observed to mostly concentrate in vulnerable rural and old unreinforced masonry buildings, with aspects such as complete or partial out of plane collapse of walls, collapse of roofs due to loss of seating, shear cracking in masonry walls/panels, shear and flexural damage in masonry spandrels, cracking at infill‐frame interface, damage at building corners, pounding damage, toppled minarets, and damage due to ground settlement.