VBVitalii Budnyk

Vitalii Budnyk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vitalii Budnyk has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Algorithm for Classification of Patient Groups Based on the LDA Method

    by Vitalii Budnyk, Mykola Budnyk

    Introduction. The article is devoted to the development of the algorithm of classification of several groups of patients using the LDA method at certain stages of its work. The algorithm allows achieve high discrimination value, to work with a variety of parameters and to separate more than two groups of patients. It is used for the analysis of biomedical data, namely for the array of indicators of various nature described healthy persons and persons with the detected disease. The purpose of paper is to develop an algorithm to increase the power of discrimination of an array of medical data that may include hundreds of healthy people and patients with connective tissue diseases, and each person is described by hundreds of parameters. Results. The authors proposed an algorithm for increasing classification accuracy based on parameter selection using sequential multivariate LDA tests. An example of the application of the algorithm to the task of analyzing a fairly large array of data (501 individuals: 295 healthy, 206 patients, 240 parameters) and identifying informative parameters for diagnosing children with connective tissue diseases is given. As a result of the application of this algorithm, a discriminant function and a decision rule were obtained, which allows achieve an average accuracy of discrimination over the entire set of parameters of 85 %. In addition, the algorithm is applied for two separate groups of parameters - blood indicators and biochemical analysis, while the average accuracy of discrimination reaches 84 % and 90 %, respectively. Conclusions. The algorithm of classification groups of patients with the use of LDA has been developed, which allows achieve high accuracy of discrimination. The results of its application in solving the real data set are given. The results of its application to solving the task of classification of medical data show its ability to improve classification accuracy. Keywords: algorithm, classification, analysis, informative parameters, LDA.

  • Open Access

    Calibrating and Graduating of Multi-Sensor Gas Analyzer

    by Vitalii Budnyk, Maksym Mudrenko, Serhii Lukash, Mykola Budnyk

    Introduction. The article is devoted to the calibration and graduation of the multi-sensor gas analyzer developed at the V.M. Glushkov Institute of Cybernetics of National Academy of Sciences of Ukraine. The modern trend in the development of medical equipment, in particular, containing built-in measuring devices, consists in its miniaturization, intellectualization, the use of information technologies, and the introduction of wireless and network means of data transmission. The purpose of the article is to design, create electronics and software for recording the concentration of three gases (oxygen, carbon dioxide and carbon monoxide), test and calibrate the device. Results. Three prototypes of sensor modules for oxygen, carbon dioxide and carbon monoxide have been created. The structure, scheme of connection of sensor modules, and the principle of operation of the gas analyzer was described. Testing and optimization of these prototypes were performed. Auxiliary pneumatic equipment for checking the performance of devices, their calibration and graduation was manufactured. Measurement technique was developed and test measurements of the specified gases were performed. The calibration technique was developed and the device was calibrated using two test gas samples such as ethanol vapor and air-gas mixture of carbon dioxide. In addition, a special software has been developed, which allow observe a registered input signal from sensor modules and store it to the file. Conclusions. As a result of the work, prototype of the device was created, its testing, calibration and graduation were carried out at the State Enterprise "Ukrmetrteststandart", 4 certificates of metrological attestation were obtained. The gas analyzer can be used for screening of healthy persons based on study of exhalation to predict the risk of diseases.

  • Open Access

    Development and Conformity Assessment of ECG-Photometric Complex Software

    by Vitalii Budnyk, Tetiana Ryzhenko, Mykola Budnyk

    Introduction. The article is devoted to the software "PulseWave", which is used as part of the ECG-photometric complex for research in medical institutions. For further implementation of the complex in medical practice, it is necessary to assess the compliance of this software in accordance with the requirements of the technical regulations for medical devices. There are two ways to perform software conformity assessment: as part of the ECG photometric complex or separately from it (stand alone). In this paper, the option of conducting a stand alone conformity assessment was chosen, i.e. as a separate product. This approach is the most promising, given the development of "cloud" storage and data processing environments and the need to introduce into medical practice of treatment and prevention facilities in Ukraine. The purpose of the article is to develop software and prepare it for conformity assessment in accordance with the requirements of the technical regulations for medical devices. Results. The authors consider the structure and principle of operation of the software "PulseWave" ECG-photometric complex. The main stages of the life cycle of this software according to international standards are given. A risk assessment report has been developed, which shows and evaluates the main errors that may occur in the work of the software; and ways to eliminate them. Conclusions. The software development, development of its life cycle and risk analysis provide an opportunity to start the procedure of assessing its compliance with the requirements of the technical regulations for medical devices in accordance with international standards. Keywords: software, conformity assessment, life cycle, application risks.

  • Open Access

    Development of Metrological Maintenance of Photometric Devices For Pulsometry

    by V. Degtjaruk, М. Khоdаkоvskyi, М. Budnyk, V. Budnyk, М. Мudrenko, Ya. Tymoshenko

    Investigating pulse in different parts of the body is of great interest to doctors. The purpose is the development of metrological maintenance, calibration and certification of photometric instruments [1—3]. Photoplethysmograph is designed to record changes in optical density of a person’s body area with a beam of light reflected in the light [4—6]. Measurements are carried out non-invasively [7]. Such device registers pulse wave (PW) signals and reference ECG with computer processing, Fig. 1—2 [8—10]. A working measure (LED) was created and calibrated using an optical radiation power meter based on the substitution method [11], test bench is at Fig. 3, calibration results — in Table 1 and Fig. 4. Test bench for device calibration and an optical radiator are at Fig. 5—6, view of calibrated signal — at Fig. 7. As a result of calibration (Table 2) the dependence of the output signal on LED power supply (Fig. 8) is obtained, and the calibration dependence is shown at Fig. 9. In the test bench for SMC used standardized light filters KNS-01 at a wavelength of 630 nm (Fig. 10a). The calibration curve is calculated as the dependence of the relative coefficient of inverse light dispersion (RCILD) on PW (Fig. 10b, Table 3). The view of output signal is at Fig. 11. As a result of SMC, the limits of permissible absolute error of 2 % in the range of RCILD (15—100) % are defined.


  • Development of 4-channel cardiomagnetic scaner and technical requirements for 9-channel scaner to diagnose the heart abnormalities

    by Mykola Budnyk, Volodymyr Sosnytskyi, Igor Voitovych, Vitaliy Maiko, Yuriy Minov, Pavlo Sutkovyi, Oleksandr Zakorchenyi, Tetiana Ryzhenko, Vitaliy Budnyk

    Detail description of hardware and software of novel Ukrainian generation of magnetocardiographic apparatus - cardiomagnetic scanner CARDIOMAGSCAN have been presented. This cheaper supersensitive device includes 4 signal SQUID-channels, electrocardiograph, and automatic electromechanical system for patient scanning. Scanner is enabled to perform observation of the human heart during 15 minutes at unshielded environment. Device is intended to non-invasive medical diagnostics of cardiology diseases with help of advanced software including early stages, difficult-to-diagnose cases, and asymptomatic forms.


  • Improvement of Small-Channel MCG System for Unshielded Environment

    by Mykola M. Budnyk, Oleksandr V. Zakorcheny, Vitaly C. Koshelnyk, Vitaly M. Budnyk, Volodymyr V. Lukashyk, Yuriy D. Minov, Pavlo G. Sutkovyi, Tetyana M. Ryzhenko


  • Studying of SQUID-magnetometry system for active and passive biomagnetic researches at unshielded environment

    by O.V. Zakorcheny, V.M. Budnyk, M.M. Budnyk, Yu. D. Minov, O.A. Ostapchuk, T. M. Ryzhenko, P. B. Shpylyovy, P. G. Sutkovyi

    Biomagnetic measurements such as magneto-cardiography (passive) or biosusceptometry (active) are promising to utilize at biomedical application. Comparison of different SQUID-magnetometers at unshielded environment are performed in order to optimization its designs.


  • SQUID‐imaging technology to study magnetic nanocarriers for targeted magnetic transport

    by M.M. Budnyk, N.O. Dudchenko, O.M. Stavynska, Y.O. Alekseytsev, O.K. Dudchenko, I.A. Chaikovsky, Y.D. Minov, P.G. Sutkovyi, P.B. Shpylyovy, T.M. Ryzhenko, et al.

    The aim of the study was to develop SQUID‐magnetometer system and to reveal the ability of above system to monitor the dynamics of injected magnetic nanoparticles (MNP) into rabbit’s body. MNP were prepared by first precipitation of ferrous hydroxide which was then crystallized into magnetite in the presence of potassium nitrate as mild oxidizing agent and further the MNP surface was modified with oxidized hidroxyethylstarch. The dynamics of the MNP distribution into the rabbit tissues according to the electron‐spin resonance (ESR) data shows that after 60 min of nanomaterial preparation circulation into the rabbit’s body the preparation redistribution occurs in favor of liver and spleen. The magnetic field applying to the kidneys area leads to the considerable increase of iron concentration in kidneys. As a result of magnetic fields measurements over the rabbit with injected MNP using developed SQUID‐magnetometry system, the maps of MNP spatial distribution into the rabbit’s body were obtained.


  • Improved Distributions of Densities of Pseudo Currents Obtained from Test Magnetic or Electropotential Images with Dipole Structure

    by Nikolay N. Budnyk, Vitaliy N. Budnyk

    We suggest several approaches to reconstruction of pseudo current distribution on the basis of Cohen-Hosaka and Fourier transforms for analysis of electropotential maps with dipole structure. The method provides a unique solution, is carried out correctly and allows visualization of sources of magnetic or electric fields. This approach can be useful in development of new methods of noninvasive diagnostics with use of magnetocardiography or potential mapping of human body.

  • Decomposition of Test Magnetic and Electropotential Images with Non-Dipole Structure According to Multipole Expansion

    by N. N. Budnyk, V. N. Budnyk

    An approach to analysis of magnetic and electropotential maps, consisting in their expansion into orthogonal images using the two-dimensional Fourier transform, is suggested. The method has a unique solution, is performed correctly, possesses a possibility of space map filtration, error does not exceed 3 %. This approach can be useful in development of new methods of noninvasive diagnosis of electrophysiological abnormalities in human heart, characterized by the presence of complex (non-dipole) source of bioelectric activity.