Kevin C. McGill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kevin C. McGill has a total of 140 co-authors. Here are the top co-authors by number of shared publications:
Leslie J. Dorfman
10 shared publications- Hamid Reza Marateb
Biomedical Engineering Department, Engineering Faculty, University of Isfahan, Isfahan 81746-73441, Iran
6 shared publications Z.C. Lateva
6 shared publicationsEdward A. Clancy
Worcester Polytechnic Institute, Worcester, MA, USA
5 shared publicationsZoia C. Lateva
Spinal Cord Injury Center, VA Palo Alto Health Care System, Palo Alto, CA, USA
5 shared publicationsDario Farina
Department of Bioengineering, Imperial College London, London, UK
4 shared publications
Latest Publications
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (1) , 378-389
An Accurate and Real-Time Method for Resolving Superimposed Action Potentials in MultiUnit Recordings
Objective: Spike sorting of muscular and neural recordings requires separating action potentials that overlap in time (superimposed action potentials (APs)). We propose a new algorithm for resolving superimposed action potentials, and we test it on intramuscular EMG (iEMG) and intracortical recordings. Methods: Discrete-time shifts of the involved APs are first selected based on a heuristic extension of the peel-off algorithm. Then, the time shifts that provide the minimal residual Euclidean norm are identified (Discrete Brute force Correlation (DBC)). The optimal continuous-time shifts are then estimated (High-Resolution BC (HRBC)). In Fusion HRBC (FHRBC), two other cost functions are used. A parallel implementation of the DBC and HRBC algorithms was developed. The performance of the algorithms was assessed on 11,000 simulated iEMG and 14,000 neural recording superpositions, including two to eight APs, and eight experimental iEMG signals containing four to eleven active motor units. The performance of the proposed algorithms was compared with that of the Branch-and-Bound (BB) algorithm using the Rank-Product (RP) method in terms of accuracy and efficiency. Results: The average accuracy of the DBC, HRBC and FHRBC methods on the entire simulated datasets was 92.16±17.70, 93.65±16.89, and 94.90±15.15 (%). The DBC algorithm outperformed the other algorithms based on the RP method. The average accuracy and running time of the DBC algorithm on 10.5 ms superimposed spikes of the experimental signals were 92.1±21.7 (%) and 2.3±15.3 (ms). Conclusion and Significance: The proposed algorithm is promising for real-time neural decoding, a central problem in neural and muscular decoding and interfacing.
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (1) , 378-389
An Accurate and Real-Time Method for Resolving Superimposed Action Potentials in MultiUnit Recordings
Objective: Spike sorting of muscular and neural recordings requires separating action potentials that overlap in time (superimposed action potentials (APs)). We propose a new algorithm for resolving superimposed action potentials, and we test it on intramuscular EMG (iEMG) and intracortical recordings. Methods: Discrete-time shifts of the involved APs are first selected based on a heuristic extension of the peel-off algorithm. Then, the time shifts that provide the minimal residual Euclidean norm are identified (Discrete Brute force Correlation (DBC)). The optimal continuous-time shifts are then estimated (High-Resolution BC (HRBC)). In Fusion HRBC (FHRBC), two other cost functions are used. A parallel implementation of the DBC and HRBC algorithms was developed. The performance of the algorithms was assessed on 11,000 simulated iEMG and 14,000 neural recording superpositions, including two to eight APs, and eight experimental iEMG signals containing four to eleven active motor units. The performance of the proposed algorithms was compared with that of the Branch-and-Bound (BB) algorithm using the Rank-Product (RP) method in terms of accuracy and efficiency. Results: The average accuracy of the DBC, HRBC and FHRBC methods on the entire simulated datasets was 92.16±17.70, 93.65±16.89, and 94.90±15.15 (%). The DBC algorithm outperformed the other algorithms based on the RP method. The average accuracy and running time of the DBC algorithm on 10.5 ms superimposed spikes of the experimental signals were 92.1±21.7 (%) and 2.3±15.3 (ms). Conclusion and Significance: The proposed algorithm is promising for real-time neural decoding, a central problem in neural and muscular decoding and interfacing.
- 22 December 2021
- Published by Georg Thieme Verlag KG in Seminars in Musculoskeletal Radiology
- Vol. 25 (06) , 725-734
Musculoskeletal Applications of Magnetic Resonance-Guided Focused Ultrasound
Magnetic resonance-guided focused ultrasound (MRgFUS) is a novel noninvasive therapy that uses focused sound energy to thermally ablate focal pathology within the body. In the United States, MRgFUS is approved by the Food and Drug Administration for the treatment of uterine fibroids, palliation of painful bone metastases, and thalamotomy for the treatment of essential tremor. However, it has also demonstrated utility for the treatment of a wide range of additional musculoskeletal (MSK) conditions that currently are treated as off-label indications. Advantages of the technology include the lack of ionizing radiation, the completely noninvasive technique, and the precise targeting that offer unprecedented control of the delivery of the thermal dose, as well as real-time monitoring capability with MR thermometry. In this review, we describe the most common MSK applications of MRgFUS: palliation of bone metastases, treatment of osteoid osteomas, desmoid tumors, facet arthropathy, and other developing indications.
- 22 December 2021
- Published by Georg Thieme Verlag KG in Seminars in Musculoskeletal Radiology
- Vol. 25 (06) , 725-734
Musculoskeletal Applications of Magnetic Resonance-Guided Focused Ultrasound
Magnetic resonance-guided focused ultrasound (MRgFUS) is a novel noninvasive therapy that uses focused sound energy to thermally ablate focal pathology within the body. In the United States, MRgFUS is approved by the Food and Drug Administration for the treatment of uterine fibroids, palliation of painful bone metastases, and thalamotomy for the treatment of essential tremor. However, it has also demonstrated utility for the treatment of a wide range of additional musculoskeletal (MSK) conditions that currently are treated as off-label indications. Advantages of the technology include the lack of ionizing radiation, the completely noninvasive technique, and the precise targeting that offer unprecedented control of the delivery of the thermal dose, as well as real-time monitoring capability with MR thermometry. In this review, we describe the most common MSK applications of MRgFUS: palliation of bone metastases, treatment of osteoid osteomas, desmoid tumors, facet arthropathy, and other developing indications.
- Top Cited Papers
- 1 August 2020
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 53, 102438
Consensus for experimental design in electromyography (CEDE) project: Amplitude normalization matrix
- 1 August 2020
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 53, 102438
Top Cited PapersConsensus for experimental design in electromyography (CEDE) project: Amplitude normalization matrix
- 12 December 2019
- Published by Springer Nature in Spinal Cord Series and Cases
- Vol. 5 (1) , 1-8
Quantitative electrodiagnostic patterns of damage and recovery after spinal cord injury: a pilot study
Study design Prospective observational pilot study. Objectives To compare quantitative electromyographic (EMG), imaging and strength data at two time points in individuals with cervical spinal cord injury (SCI). Setting SCI center, Veterans Affairs Health Care System, Palo Alto, California, USA. Methods Subjects without suspected peripheral nerve injury were recruited within 3 months of injury. Needle EMG examination was performed in myotomes above, at, and below the SCI level around 11- and 12-months post injury. EMG data were decomposed using custom software into constituent motor unit trains and each distinct motor unit was analyzed for firing rate and amplitude. Strength measurements were made with dynamometry and according to the International Standard of Neurologic Classification of SCI (ISNCSCI). Cervical magnetic resonance images (MRI) were evaluated by two neuroradiologists for gray and white matter damage around the SCI. Here, we compare the EMG, strength, and imaging findings of the one of the four participants who completed both 3- and 12-month EMG evaluations. Results There was an increase in force generation in all muscles tested at 1 year. Localized findings of very fast firing motor units helped localize spinal cord damage and revealed gray matter damage in spinal segments where MRI was normal. Meanwhile, improvement in strength over time corresponded with different electrophysiologic patterns. Conclusions Electromyographic decomposition at two time points provides valuable information about localization of spinal cord damage, integrity of motor neuron pools and may provide a unique understanding of neural recovery mechanisms.
- 12 December 2019
- Published by Springer Nature in Spinal Cord Series and Cases
- Vol. 5 (1) , 1-8
Quantitative electrodiagnostic patterns of damage and recovery after spinal cord injury: a pilot study
Study design Prospective observational pilot study. Objectives To compare quantitative electromyographic (EMG), imaging and strength data at two time points in individuals with cervical spinal cord injury (SCI). Setting SCI center, Veterans Affairs Health Care System, Palo Alto, California, USA. Methods Subjects without suspected peripheral nerve injury were recruited within 3 months of injury. Needle EMG examination was performed in myotomes above, at, and below the SCI level around 11- and 12-months post injury. EMG data were decomposed using custom software into constituent motor unit trains and each distinct motor unit was analyzed for firing rate and amplitude. Strength measurements were made with dynamometry and according to the International Standard of Neurologic Classification of SCI (ISNCSCI). Cervical magnetic resonance images (MRI) were evaluated by two neuroradiologists for gray and white matter damage around the SCI. Here, we compare the EMG, strength, and imaging findings of the one of the four participants who completed both 3- and 12-month EMG evaluations. Results There was an increase in force generation in all muscles tested at 1 year. Localized findings of very fast firing motor units helped localize spinal cord damage and revealed gray matter damage in spinal segments where MRI was normal. Meanwhile, improvement in strength over time corresponded with different electrophysiologic patterns. Conclusions Electromyographic decomposition at two time points provides valuable information about localization of spinal cord damage, integrity of motor neuron pools and may provide a unique understanding of neural recovery mechanisms.
- 1 October 2019
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 48, 128-144
Consensus for experimental design in electromyography (CEDE) project: Electrode selection matrix
- 1 October 2019
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 48, 128-144
Consensus for experimental design in electromyography (CEDE) project: Electrode selection matrix
- 1 September 2016
- Published by Elsevier in Clinical Neurophysiology
- Vol. 127 (9) , 3198-3204
Motor unit activity within the depth of the masseter characterized by an adapted scanning EMG technique
- 1 September 2016
- Published by Elsevier in Clinical Neurophysiology
- Vol. 127 (9) , 3198-3204
Motor unit activity within the depth of the masseter characterized by an adapted scanning EMG technique
- 1 January 2015
- Published by Elsevier in Neuromuscular Disorders
- Vol. 25 (1) , 73-80
Myotonic discharges discriminate chloride from sodium muscle channelopathies
- 1 January 2015
- Published by Elsevier in Neuromuscular Disorders
- Vol. 25 (1) , 73-80
Myotonic discharges discriminate chloride from sodium muscle channelopathies
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance of three electromyogram decomposition algorithms as a function of signal to noise ratio: Assessment with experimental and simulated data
We have previously published a full report [25] comparing the performance of three automated electromyogram (EMG) decomposition algorithms. In our prior report, the primary measure of decomposition difficulty/challenge for each data record was the “Decomposability Index” of Florestal et al. [3]. This conference paper is intended to augment our prior work by providing companion results when the measure of difficulty is the motor unit signal-to-noise ratio (SNR MU ) - a measure that is commonly used in the literature. Thus, we analyzed experimental and simulated data to assess the agreement and accuracy, as a function of SNR MU , of three publicly available decomposition algorithms-EMGlab[1] (single channel data only), Fuzzy Expert [2] and Montreal [3]. Data consisted of quadrifilar needle EMGs from the tibialis anterior of 12 subjects at 10%, 20% and 50% maximum voluntary contraction (MVC); single channel needle EMGs from the biceps brachii of 10 control subjects during contractions just above threshold; and matched simulated data. Performance vs. SNR MU was assessed via agreement between pairs of algorithms for experimental data and accuracy with respect to the known decomposition for simulated data. For experimental data, RMS errors between the achieved agreement and those predicted by an exponential model as a function of SNR MU ranged from 8.4% to 19.2%. For the simulations, RMS errors between achieved accuracy and those predicted by the SNR MU exponential model ranged from 3.7% to 14.7%. Agreement/accuracy was strongly related to SNR MU .
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance of three electromyogram decomposition algorithms as a function of signal to noise ratio: Assessment with experimental and simulated data
We have previously published a full report [25] comparing the performance of three automated electromyogram (EMG) decomposition algorithms. In our prior report, the primary measure of decomposition difficulty/challenge for each data record was the “Decomposability Index” of Florestal et al. [3]. This conference paper is intended to augment our prior work by providing companion results when the measure of difficulty is the motor unit signal-to-noise ratio (SNR MU ) - a measure that is commonly used in the literature. Thus, we analyzed experimental and simulated data to assess the agreement and accuracy, as a function of SNR MU , of three publicly available decomposition algorithms-EMGlab[1] (single channel data only), Fuzzy Expert [2] and Montreal [3]. Data consisted of quadrifilar needle EMGs from the tibialis anterior of 12 subjects at 10%, 20% and 50% maximum voluntary contraction (MVC); single channel needle EMGs from the biceps brachii of 10 control subjects during contractions just above threshold; and matched simulated data. Performance vs. SNR MU was assessed via agreement between pairs of algorithms for experimental data and accuracy with respect to the known decomposition for simulated data. For experimental data, RMS errors between the achieved agreement and those predicted by an exponential model as a function of SNR MU ranged from 8.4% to 19.2%. For the simulations, RMS errors between achieved accuracy and those predicted by the SNR MU exponential model ranged from 3.7% to 14.7%. Agreement/accuracy was strongly related to SNR MU .
- 22 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 23 (1) , 32-40
Cross-Comparison of Three Electromyogram Decomposition Algorithms Assessed With Experimental and Simulated Data
The reliability of clinical and scientific information provided by algorithms that automatically decompose the electromyogram (EMG) depends on the algorithms' accuracies. We used experimental and simulated data to assess the agreement and accuracy of three publicly available decomposition algorithms-EMGlab (McGill , 2005) (single channel data only), Fuzzy Expert (Erim and Lim, 2008) and Montreal (Florestal , 2009). Data consisted of quadrifilar needle EMGs from the tibialis anterior of 12 subjects at 10%, 20% and 50% maximum voluntary contraction (MVC); single channel needle EMGs from the biceps brachii of 10 controls and 10 patients during contractions just above threshold; and matched simulated data. Performance was assessed via agreement between pairs of algorithms for experimental data and accuracy with respect to the known decomposition for simulated data. For the quadrifilar experimental data, median agreements between the Montreal and Fuzzy Expert algorithms at 10%, 20%, and 50% MVC were 95%, 86%, and 64%, respectively. For the single channel control and patient data, median agreements between the three algorithm pairs were statistically similar at ~ 97% and ~ 92%, respectively. Accuracy on the simulated data exceeded this performance. Agreement/accuracy was strongly related to the Decomposability Index (Florestal , 2009). When agreement was high between algorithm pairs applied to simulated data, so was accuracy.
- 22 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 23 (1) , 32-40
Cross-Comparison of Three Electromyogram Decomposition Algorithms Assessed With Experimental and Simulated Data
The reliability of clinical and scientific information provided by algorithms that automatically decompose the electromyogram (EMG) depends on the algorithms' accuracies. We used experimental and simulated data to assess the agreement and accuracy of three publicly available decomposition algorithms-EMGlab (McGill , 2005) (single channel data only), Fuzzy Expert (Erim and Lim, 2008) and Montreal (Florestal , 2009). Data consisted of quadrifilar needle EMGs from the tibialis anterior of 12 subjects at 10%, 20% and 50% maximum voluntary contraction (MVC); single channel needle EMGs from the biceps brachii of 10 controls and 10 patients during contractions just above threshold; and matched simulated data. Performance was assessed via agreement between pairs of algorithms for experimental data and accuracy with respect to the known decomposition for simulated data. For the quadrifilar experimental data, median agreements between the Montreal and Fuzzy Expert algorithms at 10%, 20%, and 50% MVC were 95%, 86%, and 64%, respectively. For the single channel control and patient data, median agreements between the three algorithm pairs were statistically similar at ~ 97% and ~ 92%, respectively. Accuracy on the simulated data exceeded this performance. Agreement/accuracy was strongly related to the Decomposability Index (Florestal , 2009). When agreement was high between algorithm pairs applied to simulated data, so was accuracy.
- 8 May 2014
- Published by Wiley in Arthroscopy
- Vol. 30 (8) , 915-920
Magnetic Resonance Imaging Evaluation of Normal Glenoid Length and Width: An Anatomic Study
Purpose: The purpose of this study was to evaluate the measured dimensions of the normal glenoid on sagittal magnetic resonance (MR) imaging to determine whether a fixed ratio of glenoid length and width can be determined. Methods: MR images of 90 glenoids in 84 patients were analyzed. The mean age was 54.8 years, with 44 male and 40 female patients. Glenoid length and width at the widest dimension were measured and recorded by 3 independent examiners. The ratio of length to width and the ratio of the length of the superior pole at the widest point to the total length were calculated. Intraclass correlation coefficients, Spearman and Pearson correlations, regression analysis with cross validation, and coefficients of variation were calculated. Results: The mean glenoid length was 37.5 ± 3.8 mm, whereas the mean width was 24.4 ± 2.9 mm. The mean ratio of length to width was 1.55 ± 0.1, whereas the mean ratio of the distance from the superior pole to the widest point to the total glenoid length was 0.64 ± 0.03. The calculated ratios were less variable than the absolute length and width. Cross validation of length for width showed a 95% prediction band width of 4.48 mm, with an average absolute error of prediction of 1.46 mm, and was equally specific when separated by gender. The width was equal to 0.65 times the length. Conclusions: Measurement of glenoid length and width using MR imaging results in a consistent ratio of length to width independent of patient age and gender, where the width was equal to 0.65 times the length at a point two‐thirds along the inferosuperior axis. Level of Evidence: Level IV, case series.
- 8 May 2014
- Published by Wiley in Arthroscopy
- Vol. 30 (8) , 915-920
Magnetic Resonance Imaging Evaluation of Normal Glenoid Length and Width: An Anatomic Study
Purpose: The purpose of this study was to evaluate the measured dimensions of the normal glenoid on sagittal magnetic resonance (MR) imaging to determine whether a fixed ratio of glenoid length and width can be determined. Methods: MR images of 90 glenoids in 84 patients were analyzed. The mean age was 54.8 years, with 44 male and 40 female patients. Glenoid length and width at the widest dimension were measured and recorded by 3 independent examiners. The ratio of length to width and the ratio of the length of the superior pole at the widest point to the total length were calculated. Intraclass correlation coefficients, Spearman and Pearson correlations, regression analysis with cross validation, and coefficients of variation were calculated. Results: The mean glenoid length was 37.5 ± 3.8 mm, whereas the mean width was 24.4 ± 2.9 mm. The mean ratio of length to width was 1.55 ± 0.1, whereas the mean ratio of the distance from the superior pole to the widest point to the total glenoid length was 0.64 ± 0.03. The calculated ratios were less variable than the absolute length and width. Cross validation of length for width showed a 95% prediction band width of 4.48 mm, with an average absolute error of prediction of 1.46 mm, and was equally specific when separated by gender. The width was equal to 0.65 times the length. Conclusions: Measurement of glenoid length and width using MR imaging results in a consistent ratio of length to width independent of patient age and gender, where the width was equal to 0.65 times the length at a point two‐thirds along the inferosuperior axis. Level of Evidence: Level IV, case series.