Ning Hua
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ning Hua has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Gang Ding
Tianjin Key Laboratory of Retinal Functions and Diseases , Tianjin Branch of National Clinical Research Center for Ocular Disease , Eye Institute and School of Optometry , Tianjin Medical University Eye Hospital , Tianjin , China , tmuec.com
3 shared publications - Jing Li
Department of Pediatric Ophthalmology and Strabismus, Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
3 shared publications - Beihong Liu
Graduate School of Peking Union Medical College, Beijing, China
1 shared publication - Binbin Wang
Affiliations Center for Genetics, National Research Institute of Family Planning, Beijing, China, Graduate School of Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China, NHC Key Laboratory of Reproductive Health Engineering Technology Research (NRIFP), National Research Institute for Family Planning, Beijing, China
1 shared publication Charles Wormington
Salus Univerisity Pennsylvania College of Optometry, Elkins Park, USA
1 shared publicationHui Zheng
Tianjin Eye Hospital, Tianjin, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Ophthalmology
- Vol. 2026 (1) , 1051158
Interocular Symmetry in Anterior Segment Parameters in Children With Intermittent Exotropia Observed by CASIA2 AS‐OCT
Purpose: To explore the interocular symmetry of the anterior segment parameters in subjects with intermittent exotropia (IXT) and compare it with that in the normal subjects. Methods: A total of 122 eyes of 61 subjects with IXT and 88 eyes of 44 normal subjects were enrolled. Central corneal thickness (CCT), the radii of curvature of the anterior and posterior lens (ALR and PLR), lens thickness (LT), lens equatorial diameter (DIA), anterior chamber depth (ACD), lens tilt, and decentration were measured with CASIA2 AS‐OCT; the parameters in IXT were measured again after cycloplegia. T ‐tests, intraclass correlation coefficients (ICCs), and Bland–Altman plots were used to compare binocular differences and quantify symmetry. We compared the binocular symmetry between normal subjects and the subjects with IXT and the symmetry in different refractive states. Results: The ICCs were high in CCT, ACD, ALR, and LT and moderate in PLR, DIA, lens tilt, and decentration in all subjects ( p < 0.05). IXT after cycloplegia showed similar ICCs to those of normal subjects, while ICCs before cycloplegia were all below normal. In the Bland–Altman plot, the IXT group had a larger mean difference and more dispersed 95% confidence intervals than the normal group. The normal group had similar ICCs for different refractive states, but hyperopic subjects had smaller ICCs than myopic subjects in the IXT group. Conclusions: IXT had lower binocular symmetry in the vision state than normal children, with the asymmetry being more pronounced in hyperopia. Binocular interocular asymmetry of children with IXT is of concern. Trial Registration: Chinese Clinical Trial Registry: ChiCTR2300075756.
- 1 January 2026
- Published by Wiley in Journal of Ophthalmology
- Vol. 2026 (1) , 1051158
Open AccessInterocular Symmetry in Anterior Segment Parameters in Children With Intermittent Exotropia Observed by CASIA2 AS‐OCT
Purpose: To explore the interocular symmetry of the anterior segment parameters in subjects with intermittent exotropia (IXT) and compare it with that in the normal subjects. Methods: A total of 122 eyes of 61 subjects with IXT and 88 eyes of 44 normal subjects were enrolled. Central corneal thickness (CCT), the radii of curvature of the anterior and posterior lens (ALR and PLR), lens thickness (LT), lens equatorial diameter (DIA), anterior chamber depth (ACD), lens tilt, and decentration were measured with CASIA2 AS‐OCT; the parameters in IXT were measured again after cycloplegia. T ‐tests, intraclass correlation coefficients (ICCs), and Bland–Altman plots were used to compare binocular differences and quantify symmetry. We compared the binocular symmetry between normal subjects and the subjects with IXT and the symmetry in different refractive states. Results: The ICCs were high in CCT, ACD, ALR, and LT and moderate in PLR, DIA, lens tilt, and decentration in all subjects ( p < 0.05). IXT after cycloplegia showed similar ICCs to those of normal subjects, while ICCs before cycloplegia were all below normal. In the Bland–Altman plot, the IXT group had a larger mean difference and more dispersed 95% confidence intervals than the normal group. The normal group had similar ICCs for different refractive states, but hyperopic subjects had smaller ICCs than myopic subjects in the IXT group. Conclusions: IXT had lower binocular symmetry in the vision state than normal children, with the asymmetry being more pronounced in hyperopia. Binocular interocular asymmetry of children with IXT is of concern. Trial Registration: Chinese Clinical Trial Registry: ChiCTR2300075756.
- Open Access
- 11 May 2024
- Published by Hindawi Limited in Journal of Ophthalmology
- Vol. 2024, 1-7
The Performance of Spot Photoscreener in 6 to 10 Weeks Infants in China: A Cross-Sectional Study
Purpose. To compare the refractive errors measured by the Spot photoscreener (with or without cycloplegia) to cycloplegic retinoscopy in 6- to 10-week-old infants. Materials and Methods. 101 right eyes from 101 healthy infants aged 6 to 10 weeks were recruited for this cross-sectional observational study. Refractive errors were measured using Spot photoscreener before and after cycloplegia, as well as cycloplegic retinoscopy. Comparisons between the refractive measurements were performed using one-way ANOVA with the post hoc Tukey HSD test or Kruskal–Wallis test with the Steel–Dwass test according to the data normality. Pearson’s correlation test and 95% confidence intervals were calculated. The agreement was evaluated using a Bland–Altman plot with 95% limits of agreement of the differences. Results. Spot photoscreener was found to underestimate the spherical equivalent by 2.33 Diopters (D) in these infants. Following the induction of cycloplegia, the spherical equivalent measured by Spot photoscreener was in excellent agreement with cycloplegic retinoscopy with the mean difference of 0.01 D. Spot photoscreener overestimated cylindrical parameter by 0.2 D with poor agreement with cycloplegic retinoscopy no matter whether cycloplegia was induced. It had good agreement with cycloplegic retinoscopy in the vector than the vector measurement. Conclusions. With the induction of cycloplegia, Spot photoscreener can accurately evaluate spherical equivalent in hyperopic infants with mild-to-moderate astigmatism. While it may provide valuable measurements of astigmatism, discrepancies in cylinder and axis should be taken into account.
- 11 May 2024
- Published by Hindawi Limited in Journal of Ophthalmology
- Vol. 2024, 1-7
Open AccessThe Performance of Spot Photoscreener in 6 to 10 Weeks Infants in China: A Cross-Sectional Study
Purpose. To compare the refractive errors measured by the Spot photoscreener (with or without cycloplegia) to cycloplegic retinoscopy in 6- to 10-week-old infants. Materials and Methods. 101 right eyes from 101 healthy infants aged 6 to 10 weeks were recruited for this cross-sectional observational study. Refractive errors were measured using Spot photoscreener before and after cycloplegia, as well as cycloplegic retinoscopy. Comparisons between the refractive measurements were performed using one-way ANOVA with the post hoc Tukey HSD test or Kruskal–Wallis test with the Steel–Dwass test according to the data normality. Pearson’s correlation test and 95% confidence intervals were calculated. The agreement was evaluated using a Bland–Altman plot with 95% limits of agreement of the differences. Results. Spot photoscreener was found to underestimate the spherical equivalent by 2.33 Diopters (D) in these infants. Following the induction of cycloplegia, the spherical equivalent measured by Spot photoscreener was in excellent agreement with cycloplegic retinoscopy with the mean difference of 0.01 D. Spot photoscreener overestimated cylindrical parameter by 0.2 D with poor agreement with cycloplegic retinoscopy no matter whether cycloplegia was induced. It had good agreement with cycloplegic retinoscopy in the vector than the vector measurement. Conclusions. With the induction of cycloplegia, Spot photoscreener can accurately evaluate spherical equivalent in hyperopic infants with mild-to-moderate astigmatism. While it may provide valuable measurements of astigmatism, discrepancies in cylinder and axis should be taken into account.
- Open Access
- 13 May 2021
- Published by Springer Nature in BMC Ophthalmology
- Vol. 21 (1) , 1-6
Recurrent dislocation of binocular crystal lenses in a patient with cystathionine beta-synthase deficiency
Background: Ectopia lentis is the common ocular manifestation of homocystinuria resulting from cystathionine beta-synthase (CBS) deficiency which has a high risk of thromboembolic complications. Case presentation: The present study reports the case of a teenager with recurrent lens dislocation and glaucoma. He was diagnosed with CBS deficiency according to a high level of serum homocysteine and compound heterozygous mutations at two different positions on the CBS gene. Antiglaucoma eyedrops and a mydriatic successfully controlled the intraocular pressure, while oral pyridoxine and betaine uptake lowered the serum homocysteine level effectively. Conclusions: Children with CBS deficiency may suffer from ectopia lentis, glaucoma and/or amblyopia. We firstly discovered a new mutation of CBS c. 697 T > G which had not been reported before. The patient was pyridoxine responsive and well controlled by medicine.
- 13 May 2021
- Published by Springer Nature in BMC Ophthalmology
- Vol. 21 (1) , 1-6
Open AccessRecurrent dislocation of binocular crystal lenses in a patient with cystathionine beta-synthase deficiency
Background: Ectopia lentis is the common ocular manifestation of homocystinuria resulting from cystathionine beta-synthase (CBS) deficiency which has a high risk of thromboembolic complications. Case presentation: The present study reports the case of a teenager with recurrent lens dislocation and glaucoma. He was diagnosed with CBS deficiency according to a high level of serum homocysteine and compound heterozygous mutations at two different positions on the CBS gene. Antiglaucoma eyedrops and a mydriatic successfully controlled the intraocular pressure, while oral pyridoxine and betaine uptake lowered the serum homocysteine level effectively. Conclusions: Children with CBS deficiency may suffer from ectopia lentis, glaucoma and/or amblyopia. We firstly discovered a new mutation of CBS c. 697 T > G which had not been reported before. The patient was pyridoxine responsive and well controlled by medicine.
- Open Access
- 11 May 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 118
Prevalence of refractive errors in Tibetan adolescents
The prevalence of adolescent eye disease in remote areas of the Qinghai-Tibet Plateau has rarely been reported. To understand the prevalence of common eye diseases in Tibet, we performed ocular-disease screening on students from primary and secondary schools in Tibet, and compared the prevalence to that in the Central China Plain (referred to here as the “plains area”). The refractive status of students was evaluated with a Spot™ vision screener. The test was conducted three or fewer times for both eyes of each student and results with best correction were recorded. A total of 3246 students from primary and secondary schools in the Tibet Naidong district were screened, yielding a refractive error rate of 28.51%, which was significantly lower than that of the plains group (28.51% vs. 56.92%, p < 0.001). In both groups, the prevalence of refractive errors among females was higher than that among males. We found that Tibetan adolescents had a lower prevalence of refractive errors than did adolescents in the plains area, which may be related to less intensive schooling and greater exposure to sunlight.
- 11 May 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 118
Open AccessPrevalence of refractive errors in Tibetan adolescents
The prevalence of adolescent eye disease in remote areas of the Qinghai-Tibet Plateau has rarely been reported. To understand the prevalence of common eye diseases in Tibet, we performed ocular-disease screening on students from primary and secondary schools in Tibet, and compared the prevalence to that in the Central China Plain (referred to here as the “plains area”). The refractive status of students was evaluated with a Spot™ vision screener. The test was conducted three or fewer times for both eyes of each student and results with best correction were recorded. A total of 3246 students from primary and secondary schools in the Tibet Naidong district were screened, yielding a refractive error rate of 28.51%, which was significantly lower than that of the plains group (28.51% vs. 56.92%, p < 0.001). In both groups, the prevalence of refractive errors among females was higher than that among males. We found that Tibetan adolescents had a lower prevalence of refractive errors than did adolescents in the plains area, which may be related to less intensive schooling and greater exposure to sunlight.