SYShuji Yamamoto

Shuji Yamamoto

*This is an algorithmically generated author record based on publicly available information.

Shuji Yamamoto has a total of 165 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correctly Parsed, Wrong Lesion: Where Target Mix-Ups Arise When AI Binds Measurement Requests to Lung CT Nodules—A Staged, Hypothesis-Generating Evaluation

    by Shuji Yamamoto

    AI systems that measure lesions on request can compute correctly on the wrong lesion, an outcome no benchmark I found scores. I located where such mix-ups arise, in three stages on public lung CTs. A stratified audit of 1785 DICOM segmentation series found identical coded semantics for all 5192 pairs of different nodules on one scan; nodule numbers existed but needed linking to the request. A gate trusting structural checks authorized all 200 constructed requests, 89 for a mismatched and 41 for an ambiguous target. An expert wrote 60 requests in three sets, with each design frozen first. A rule parser carried a misread rank (“longest diameter” read as “largest”) in every resolution; removing it post hoc kept 13 of 26 correct resolutions, and agreement with a choice-constrained model parser removed all 25 rank-dependent wrong ones. A whole-lung definition of “lateral” excluded an intended nodule. In the confirmatory set, both pre-specified consensus gates authorized the nearest unintended nodule in two of 20 requests. Adjudication found three requests naming a lobe the images contradicted and two unassignable lobes; no map error was demonstrated. Parser agreement did not catch a request–image discordance. Clinical safety and workflow benefit were not evaluated.

  • Open Access

    Error Injection in Task-Based Image Quality Pipelines: What Regression Testing Cannot Catch, and Why Neither Internal Identities nor Closed-Form References Suffice Alone

    by Shuji Yamamoto

    Task-based image quality assessment—the modulation transfer function, the noise power spectrum (NPS), the noise-equivalent quanta and model observers—fails by returning a plausible wrong number rather than an error, and the regression test most implementations carry cannot tell a plausible right answer from a plausible wrong one, because the stored reference was recorded from the defective code. We injected six defects into a validated implementation of that chain through a severity dial that recovers the correct pipeline exactly at zero. A self-consistency regression test detected none of the six. Four internal identities, which need no ground truth, and two closed-form references, which need a phantom whose answer is known, together detected all six, in every case at or before the severity at which the reported detectability index d′ became wrong by more than 5%—an error that three of the six never produced. Neither family sufficed alone: the internal identities detected three of the six and the closed-form references five, and peak errors in a reported d′ reached 90%. Run unmodified on measured American College of Radiology (ACR) phantom projections across seven reconstruction kernels, the three identities that can be evaluated without ground truth transferred intact—Parseval held to 4×10−16—but their tolerances did not, and the strongest apodisation drove the noise dynamic range to within 0.6% of the threshold beyond which a prewhitening observer should return no value at all rather than a computed one, because 1/NPS has ceased to be numerically meaningful.

  • Open Access

    Anatomy-Weighted CTDIvol from Routine CT Metadata: A Patient-Specific, Multi-Vendor Study Using Deep-Learning Segmentation

    by Shuji Yamamoto

    Background/Objectives: The volume computed tomography (CT) dose index (CTDIvol) is a scanner output, not an organ dose, and cannot express how tube-current modulation varies along a patient. An organ-specific weighted CTDIvol addressing this has been reported before, in single-institution cohorts and often from inputs routine archives do not retain. New here is not the quantity but what an open, multi-vendor operationalisation reveals: whether its inputs survive archive curation and what the fallback costs when they do not. Methods: Forty abdominal CT series, ten per manufacturer, were drawn from the Cancer Imaging Archive and twelve organs segmented with TotalSegmentator at inference. Of 480 requested organ–series combinations, 455 were produced. A rule-based acquisition-constancy criterion admitted 39 series. Results: Modulation weights spanned 0.59 to 1.69, so the index departs from the whole-scan CTDIvol by up to 70% within one acquisition. A recorded CTDIvol survived in 29 of 40 archived headers and was reconstructable in 5 and unavailable in 6, availability differing markedly between manufacturers. Forcing that reconstruction on series that did retain a value agreed to within 12% on three scanner models and diverged by 58% and 84% on two others. Estimated organ mass was broadly consistent with International Commission on Radiological Protection (ICRP) Publication 89 for liver and kidneys. Conclusions: This index is not an absorbed dose; the implementation is open.

  • Open Access

    A Stability Atlas for IBSI Radiomics Features Using Synthetic Digital Phantoms, with Proof-of-Concept Physics-Based Normalisation

    by Shuji Yamamoto

    Radiomics features are strongly sensitive to image acquisition, and separating that sensitivity from biological signal usually requires repeated patient scans that cannot be shared. We present an open, fully synthetic framework (radiomics-phantom) that maps and, as a proof of concept, corrects radiomics feature instability without any patient data. Deterministic three-dimensional texture phantoms are generated as anisotropic Gaussian random fields with known ground truth and an optional embedded lesion. An independently implemented feature core aligned with the Image Biomarker Standardization Initiative (IBSI) covers all eleven IBSI-1 feature families and matched all 482 published digital-phantom benchmark values within the applicable tolerances. An image-domain acquisition simulator applies point-spread blur, slice-profile averaging, dose-scaled correlated noise, resampling, and quantisation. Per-feature reproducibility across a sweep of fifteen textures (varying correlation length, anisotropy, and intensity scale) by nine acquisition conditions, with five independent noise realisations per stochastic setting, is summarised by the absolute-agreement intraclass correlation ICC(2,1), with a realisation-aware percentile-bootstrap 95% confidence interval for every estimate; constant features are excluded from estimation. Values span nearly the full range (median 0.13, 95% CI 0.03–0.19), and a hierarchical variance decomposition attributes a median 77% of per-feature variance to the acquisition condition and under 1% to stochastic realisation; the values are interpreted as exploratory rankings within this acquisition envelope. As a proof of concept, intensity variance and grey-level co-occurrence contrast under additive Gaussian noise were normalised using calibrated, invertible response models, returning them to their noiseless values on held-out data (median error below 4% across five textures and repeated noise realisations, and about 11% when the noise level is estimated from the degraded image itself), while features the models cannot describe are refused rather than corrected. All code and a 716-test suite are released openly and archived on Zenodo. The result is a reproducible, patient-data-free testbed for radiomics feature stability.

  • Open Access

    An Open, Reproducible Gamma-Variate Pipeline for CT-Perfusion Time–Attenuation Curve Analysis, with Standardized (ASIST-Japan) Map Visualization

    by Shuji Yamamoto

    CT perfusion (CTP) is central to acute-stroke and oncologic imaging, yet quantitative outputs vary substantially across vendor software, undermining reproducibility. We present an open, transparent core (ctp-core) that fits first-pass time–attenuation curves with a gamma-variate model, derives perfusion indices (peak enhancement, time-to-peak [TTP], bolus-arrival time [BAT], area under the curve [AUC]) analytically from the fitted parameters, and renders parametric maps with the ASIST-Japan standardized lookup table (a-LUT) so that visualization is comparable across sites. Every parameter, bound, and processing step is exposed. The method is validated on Monte-Carlo synthetic curves with known ground truth; no confidential or patient data are used. Across signal-to-noise ratio (SNR) levels 5–100 (200 independent runs per level) the pipeline recovers peak time to within 0.03–0.52 s and peak amplitude to within 0.4–8.1% (mean absolute error), degrading monotonically with noise; at a representative SNR of 20 it recovers peak time within 0.13 s, peak amplitude within 2.0%, and BAT within 0.51 s, with fit quality R-squared = 0.98. The reproducibility demonstration is deterministic (fixed seed) and re-runs to bit-stable metrics. All code, the synthetic-data generator, the standardized-visualization module, evaluation scripts, and a 34-test suite are released openly for independent verification. The contribution is a fully open, parameter-transparent gamma-variate plus standardized-visualization pipeline with reproducible synthetic benchmarks — a reference others can audit, reuse, and build on.

  • Development of DICOM image-based CT low dose simulator using fan-beam transform

    by Tetsuya Horiuchi, Shuji Yamamoto, Kenya Murase

    BACKGROUND: Projection-data based method is established as an accurate simulation of low-dose CT, but cooperation of the CT manufacturer is required. Image-based method is awaited for independent and efficient research. OBJECTIVE: To develop and veri


  • Comparison of the waveforms of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency

    by Atsutoshi Hatada, Yoshitaka Okamura, Masahiro Kaneko, Takahiro Hisaoka, Shuji Yamamoto, Takeshi Hiramatsu, Yoshiharu Nishimura

    An intraoperative fluorescence imaging (IFI) system, which can provide visual images, could be the common method for assessing graft patency intraoperatively. We conducted a prospective comparison of the diagnostic accuracy of both the fast Fourier transformation (FFT) analysis of transit-time flowmetry (TTFM) waveform and the IFI system to determine graft failure. The study included 10 saphenous vein grafts (SVGs), all of which were aortocoronary grafts. Each patient underwent isolated coronary artery bypass grafting (CABG), including conventional CABG or off-pump CABG, and then underwent X-ray angiography after CABG. When intraoperative hemodynamics had stabilized, the grafts were evaluated with both the IFI system and TTFM. Based on the obtained flow profile of TTFM, certain variables were calculated. The waveforms of TTFM were analyzed with the FFT series. Harmonic distortion (HD) was calculated from the amplitudes, and the fundamental frequency was thus determined using the FFT series. The IFI system demonstrated a satisfactory flow of all grafts. X-ray angiography demonstrated that one SVG was 75% stenosed, and the others were patent. The mean graft flow (MGF) and the pulsatility index (PI) of the patent SVGs were not significantly different from those of the stenosed SVG. The HD of the patent SVGs was significantly different from that of the stenosed SVG. The HD of the TTFM waveform can provide better diagnostic accuracy for detecting clinically significant grafts than MGF and PI of TTFM and the IFI system.


  • Open Access

    In Vitro Evaluation of the Effect of Cardiac Surgery on Cancer Cell Proliferation

    by Shuji Yamamoto, Tatsuya Yoshimasu, Yoshiharu Nishimura, Shunji Uchita, Koji Toguchi, Kentaro Honda, Yoshitaka Okamura

    Objective: Operative stress of cardiovascular surgery can alter the blood levels of various physiologically active substances (e.g., cytokines, growth factors), and thus potentially affect cancer cell proliferation. How the combination of changes in blood levels of these substances affects cancer cells has not been adequately addressed. We investigated the stimulatory capacity on cancer cells of serum from patients after cardiovascular surgery, using a novel in vitro assay method. Methods: The subjects were 22 patients undergoing cardiovascular surgery, consisting of 11 off-pump and 11 on-pump procedures. Blood was sampled from each subject immediately before surgery, immediately after surgery, and after transfer to the intensive care unit. Human lung cancer cells were exposed to the serum of each blood sample from each patient, and an MTT assay was conducted to evaluate cell proliferation. Results: Serum samples of all patients showed an inhibitory effect for lung cancer cell proliferation. This inhibitory effect was lower in postoperative serum compared with serum samples before surgery. As a result, lung cancer cell proliferation was better with postoperative serum samples than preoperative serum samples. The proliferation rate after surgery, when it was compared with preoperative serum, was significantly higher in patients with on-pump procedures than in patients with off-pump procedures. Conclusion: The results of this study suggest that the operative stress of cardiovascular surgery induces changes in serum to make it less inhibitory for the cancer cell proliferation. This phenomenon is greater in patients with extracorporeal circulation.


  • Open Access

    Visceral Fat Volume and the Prevalence of Colorectal Adenoma

    by Taiki Yamaji, Motoki Iwasaki, Shizuka Sasazuki, Norie Kurahashi, Michihiro Mutoh, Shuji Yamamoto, Masahiro Suzuki, Noriyuki Moriyama, Keiji Wakabayashi, Shoichiro Tsugane

    Few epidemiologic investigations of visceral adiposity and colorectal neoplasms have attempted the direct quantification of visceral fat. The authors measured visceral fat volume among middle-aged and elderly Japanese men and women who underwent colonoscopy and positron emission tomography/computed tomography for cancer screening in Tokyo, Japan, between February 2004 and February 2005, and examined the association between visceral adiposity and colorectal adenoma in 1,205 eligible subjects. Odds ratios and 95% confidence intervals for colorectal adenoma were estimated by using an unconditional logistic regression model after adjustment for potential confounders. Despite its high correlation with body mass index, visceral fat volume was associated with the prevalence of colorectal adenoma independently of body mass index in both sexes. After further adjustment for body mass index, the odds ratio of colorectal adenoma for the highest compared with the lowest quartile of visceral fat volume was 1.58 (95% confidence interval: 1.11, 2.24) for men and women combined. Conversely, body mass index was unlikely to modify the association between visceral fat volume and colorectal adenoma (Pinteraction = 0.39). These findings add to accumulating evidence that visceral adiposity exerts an important influence on the pathogenesis of colorectal neoplasms. The mechanisms of this potential association between visceral adiposity and colorectal carcinogenesis warrant further investigation.