JAJohn Albinsson

John Albinsson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John Albinsson has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Catheter-based Ultra-high-frequency Ultrasound Imaging of Rectal Wall Histoanatomy in Children

    by Maria Evertsson, Christina Granéli, Tebin Hawez, John Albinsson, Tobias Erlöv, Pernilla Stenström

  • Open Access

    Safe Use of Adrenaline in Cryosurgery for Eyelid Basal Cell Carcinoma Evaluated With Infrared Thermography

    by Anna H. C. Wiktorin, Bohman Elin, Johanna V. Berggren, John Albinsson, Sheikh Rafi, Malmsjö Malin

    The efficacy of cryosurgery for skin cancers is believed to depend on thaw time, which may be influenced by the presence of adrenaline in local anaesthetics due to its vasoconstrictive effects. This is the first study to perform detailed, non‐invasive temperature measurements using infrared (IR) thermography during cryosurgery for basal cell carcinomas (BCCs), evaluating the impact of adrenaline on thaw time. A total of 15 patients with eyelid BCCs underwent cryosurgery with local anaesthetics both with and without adrenaline. Thawing was continuously monitored using a high‐resolution IR camera and compared with the surgeon's visual assessment. No significant difference in thaw time was observed between anaesthetics with and without adrenaline. Thermographic mapping revealed a triphasic thawing curve. The surgeon's visual assessment of thawing corresponded well with the point at which tissue temperatures rose above 0°C, likely indicating the onset of reperfusion, thus providing a clinical margin beyond the actual phase transition. This is the first study to use IR thermography to monitor cryosurgery of BCCs, demonstrating that adrenaline in local anaesthetics does not affect thaw time. The findings suggest that deeper tissue perfusion during BCC treatment may counteract superficial vasoconstriction, supporting the effective use of cryosurgery regardless of adrenaline use.

  • Two photoacoustic spectral coloring compensation techniques adapted to the context of human in-vivo oxygenation measurements

    by Azin Khodaverdi, Baptiste Jayet, Tobias Erlöv, John Albinsson, Aboma Merdasa, Nils Gustafsson, Rafi Sheikh, Malin Malmsjö, Stefan Andersson-Engels, Magnus Cinthio

    Photoacoustic imaging can potentially map oxygen saturation (sO2) non-invasively. However, in-vivo human application is challenging due to spectral coloring, which causes a wavelength-dependent fluence attenuation and uncertainty in the estimation of chromophore concentrations deep in tissue. This study compares the performances of two previously proposed methods for spectral coloring compensation on in-vivo human data. Both methods have been modified and adapted to this context. The first modified method was evaluated using a tissue-mimicking phantom, showing restoration of the original spectrum of the target and decreasing the relative mean square error from 65% to 1.2% for the highest concentration. Spatial maps of sO2 were estimated from in-vivo human finger measurements using both methods and compared with linear unmixing. Both methods reconstructed comparable values of sO2 and reduced depth-dependent changes in sO2, typically seen with linear unmixing, resulting in a gradient of saturation closer to zero as expected physiologically.


  • Open Access

    Forehead flap perfusion monitored by laser speckle contrast imaging: Importance of flap length and thickness

    by Johanna Berggren, Jens Nääv Ottosson, John Albinsson, Rafi Sheikh, Aboma Merdasa, Kajsa Tenland


  • Open Access

    Tomographic ultrasound for three-dimensional visualization of temporal arteries

    by M Naumovska, U Dahlstrand, L Engqvist, M Cinthio, J Albinsson, R Sheikh, A Merdasa, M Malmsjo

    ObjectiveConventional two-dimensional ultrasound has been assessed for the non-invasive diagnosis of giant cell arteritis (GCA), but the results are operator dependent, resulting in low sensitivity. Tomographic three-dimensional (3D) ultrasound is a novel technique that enables the objective documentation of vessel geometry. Here, for the first time, its utility is assessed for visualizing temporal arteries.MethodThe temporal artery of 14 healthy subjects and three subjects with suspected GCA was examined using tomographic 3D ultrasound.ResultsThis technique enabled 3D mapping of the architecture of the temporal artery. The inner and outer vessel diameters showed considerable interindividual variability. However, calculation of the vessel wall fraction revealed the combination of vessel wall thickening and lumen narrowing, which may be indicative of GCA.ConclusionsThis proof-of-concept study indicates that tomographic 3D ultrasound can be used for objective mapping of the temporal artery. The technique must be evaluated regarding its diagnostic sensitivity in GCA before it can be introduced in clinical practice.


  • Open Access

    Optimizing clinical O2 saturation mapping using hyperspectral imaging and diffuse reflectance spectroscopy in the context of epinephrine injection

    by Nils Gustafsson, Josefine Bunke, Ludvig Magnusson, John Albinsson, Julio Hérnandez-Palacios, Rafi Sheikh, Malin Malmsjö, Aboma Merdasa

    Clinical determination of oxygen saturation (sO2) in patients is commonly performed via non-invasive optical techniques. However, reliance on a few wavelengths and some form of pre-determined calibration introduces limits to how these methods can be used. One example involves the assessment of sO2 after injection of local anesthetic using epinephrine, where some controversy exists around the time it takes for the epinephrine to have an effect. This is likely caused by a change in the tissue environment not accounted for by standard calibrated instruments and conventional analysis techniques. The present study aims to account for this changing environment by acquiring absorption spectra using hyperspectral imaging (HSI) and diffuse reflectance spectroscopy (DRS) before, during, and after the injection of local anesthesia containing epinephrine in human volunteers. We demonstrate the need to account for multiple absorbing species when applying linear spectral unmixing in order to obtain more clinically relevant sO2 values. In particular, we demonstrate how the inclusion of water absorption greatly affects the rate at which sO2 seemingly drops, which in turn sheds light on the current debate regarding the time required for local anesthesia with epinephrine to have an effect. In general, this work provides important insight into how spectral analysis methods need to be adapted to specific clinical scenarios to more accurately assess sO2.


  • Open Access

    Breast Cancer Diagnosis Using Extended-Wavelength–Diffuse Reflectance Spectroscopy (EW-DRS)—Proof of Concept in Ex Vivo Breast Specimens Using Machine Learning

    by Nadia Chaudhry, John Albinsson, Magnus Cinthio, Stefan Kröll, Malin Malmsjö, Lisa Rydén, Rafi Sheikh, Nina Reistad, Sophia Zackrisson

    This study aims to investigate the feasibility of using diffuse reflectance spectroscopy (DRS) to distinguish malignant breast tissue from adjacent healthy tissue, and to evaluate if an extended-wavelength range (450–1550 nm) has an advantage over the standard wavelength range (450–900 nm). Multivariate statistics and machine learning algorithms, either linear discriminant analysis (LDA) or support vector machine (SVM) are used to distinguish the two tissue types in breast specimens (total or partial mastectomy) from 23 female patients with primary breast cancer. EW-DRS has a sensitivity of 94% and specificity of 91% as compared to a sensitivity of 40% and specificity of 71% using the standard wavelength range. The results suggest that DRS can discriminate between malignant and healthy breast tissue, with improved outcomes using an extended wavelength. It is also possible to construct a simple analytical model to improve the diagnostic performance of the DRS technique.


  • Open Access

    Ultrasound centre frequency shifts as a novel approach for diagnosing giant cell arteritis

    by M Naumovska, R Sheikh, J Albinsson, B Hammar, U Dahlstrand, M Malmjsö, T Erlöv

    Giant cell arteritis (GCA) is a treatable, but potentially sight- and life-threatening form of systemic vasculitis. Prompt and correct diagnosis is therefore important. Temporal artery biopsy (TAB)...


  • Photoacoustic imaging of periorbital skin cancer ex vivo: unique spectral signatures of malignant melanoma, basal, and squamous cell carcinoma

    by Magne Tordengren Stridh, Jenny Hult, Aboma Merdasa, John Albinsson, Agnes Pekar-Lukacs, Bodil Gesslein, Ulf Dahlstrand, Karl Engelsberg, Johanna Berggren, Magnus Cinthio, et al.

    Radical excision of periorbital skin tumors is difficult without sacrificing excessive healthy tissue. Photoacoustic (PA) imaging is an emerging non-invasive biomedical imagi­­ng modality that has potential for intraoperative micrographic control of surgical margins. This is the first study to assess the feasibility of PA imaging for the detection of periocular skin cancer. Eleven patients underwent surgical excision of periocular skin cancer, one of which was a malignant melanoma (MM), eight were basal cell carcinomas (BCCs), and two squamous cell carcinomas (SCCs). Six tumors were located in the eyelid, and five in periocular skin. The excised samples, as well as healthy eyelid samples, were scanned with PA imaging postoperatively, using 59 wavelengths in the range 680–970 nm, to generate 3D multispectral images. Spectral unmixing was performed using endmember spectra for oxygenated and deoxygenated Hb, melanin, and collagen, to iden­­tify the chromophore composition of tumors and healthy eyelid tissue. After PA scanning, the tumor samples were examined histopathologically using standard hematoxylin and eosin staining. The PA spectra of healthy eyelid tissue were dominated by melanin in the skin, oxygenated and deoxygenated hemoglobin in the orbicularis oculi muscle, and collagen in the tarsal plate. Multiwavelength 3D scanning provided spectral information on the three tumor types. The spectrum from the MM was primarily reconstructed by the endmember melanin, while the SCCs showed contributions primarily from melanin, but also HbR and collagen. BCCs showed contributions from all four endmembers with a predominance of HbO2 and HbR. PA imaging may be used to distinguish different kinds of periocular skin tumors, paving the way for future intraoperative micrographic control.


  • Open Access

    Blood Perfusion of Human Upper Eyelid Skin Flaps Is Better in Myocutaneous than in Cutaneous Flaps

    by Johanna V. Berggren, Kajsa Tenland, Josefine Bunke, John M.Sc. Albinsson, Jenny Hult, Aboma M.Sc. Merdasa, Rafi M.D. Sheikh, Sandra M.D. Lindstedt, Malin M.D. Malmsjö

    Background: The aim of this study was to monitor blood perfusion in human upper eyelid skin flaps and examine how the perfusion is affected by the thickness of the flap. Methods: Twenty upper eyelids were dissected as part of a blepharoplasty procedure in patients. The medial end of the blepharoplasty flap remained attached to mimic a flap design often used in reconstruction in the periocular area, a myocutaneous flap in which the blood supply follows the fibers of the orbicularis muscle and is thus parallel to the long axis of the flap. The muscle was thereafter dissected from the flap to create a cutaneous flap. Blood perfusion in the 2 types of flaps was compared using laser speckle contrast imaging. Results: Blood perfusion decreased gradually from the base to the tip of all the flaps. Perfusion was significantly higher in the myocutaneous flaps than in the cutaneous flaps (p < 0.0004): 69% in the myocutaneous flaps and 43% in the cutaneous flaps, measured 5 mm from the base. Blood perfusion was preserved to a greater extent distally in the myocutaneous flaps (minimum value seen at 25 mm) than in the cutaneous flaps (minimum seen at 11 mm). Conclusions: Blood perfusion was better preserved in myocutaneous flaps, including both skin and the orbicularis oculi muscle, than in cutaneous flaps. This may be of clinical interest in patients with poor microcirculation in which a long flap is required for reconstructive surgery.