Panagiotis Tsiamyrtzis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Panagiotis Tsiamyrtzis has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Ioannis Pavlidis
University of Houston
9 shared publications - Jhasketan Padhan
Department of Surgery, Hamad Medical Corporation, Doha, Qatar
3 shared publications - Nikhil V. Navkar
Department of Surgery, Hamad Medical Corporation, Doha, Qatar
3 shared publications - Aaron T. Becker
University of Houston
2 shared publications - Amanveer Wesley
Univ. of Houston,Dept, of Computer Science,Texas
2 shared publications - Andrew G. Webb
C. J. Gorter MRI Centre, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands
2 shared publications
Latest Publications
- Open Access
- 4 March 2026
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 13, e86566
Dynamic Augmented Reality Cues for Telementoring in Laparoscopic Surgery: Usability Study
Background: Surgical telementoring enables a remote expert surgeon (mentor) to guide an operating surgeon (mentee) during surgery and facilitates the transfer of surgical skills. However, commonly used audio and static visual cues are inadequate to demonstrate complex tool-tissue interactions. To overcome this limitation, dynamic augmented reality (AR)–based visual cues are overlayed on the operative field to demonstrate precise instrument movements. Objective: The objective of this work was to evaluate dynamic AR cues and identify the most suitable cue that effectively demonstrates the required motions of surgical instruments during laparoscopy. Methods: A user study was conducted in a simulated environment among mentor-mentee pairs using 3 dynamic AR cues (hand gestures, a 3D pointer, and a virtual tool). The task assessed how closely the mentee was able to follow the mentor. The outcomes measured were (1) dynamic time warping distance, representing the closeness of the paths followed; (2) angular error in tooltip orientation; and (3) the NASA Task Load Index, assessing cognitive workload during telementoring. Results: Telementoring using the virtual tool resulted in a reduced dynamic time warping distance compared with hand gestures ( P <.01 for 12/13, 92.3% of the trials) and the 3D pointer ( P <.05 for 11/13, 84.6% of the trials). Lower orientation error was also noted while using the virtual tool as compared with hand gestures ( P <.05 for 5 of 6 poses). There were no substantial differences in the NASA Task Load Index scores. Conclusions: Use of a virtual tool (as a dynamic AR cue) enabled the mentee to follow the mentor’s instructions with fewer errors than both hand gestures and a 3D pointer without increasing cognitive workload. Further research is needed to assess the clinical effectiveness of the virtual tool during live surgery.
- 4 March 2026
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 13, e86566
Open AccessDynamic Augmented Reality Cues for Telementoring in Laparoscopic Surgery: Usability Study
Background: Surgical telementoring enables a remote expert surgeon (mentor) to guide an operating surgeon (mentee) during surgery and facilitates the transfer of surgical skills. However, commonly used audio and static visual cues are inadequate to demonstrate complex tool-tissue interactions. To overcome this limitation, dynamic augmented reality (AR)–based visual cues are overlayed on the operative field to demonstrate precise instrument movements. Objective: The objective of this work was to evaluate dynamic AR cues and identify the most suitable cue that effectively demonstrates the required motions of surgical instruments during laparoscopy. Methods: A user study was conducted in a simulated environment among mentor-mentee pairs using 3 dynamic AR cues (hand gestures, a 3D pointer, and a virtual tool). The task assessed how closely the mentee was able to follow the mentor. The outcomes measured were (1) dynamic time warping distance, representing the closeness of the paths followed; (2) angular error in tooltip orientation; and (3) the NASA Task Load Index, assessing cognitive workload during telementoring. Results: Telementoring using the virtual tool resulted in a reduced dynamic time warping distance compared with hand gestures ( P <.01 for 12/13, 92.3% of the trials) and the 3D pointer ( P <.05 for 11/13, 84.6% of the trials). Lower orientation error was also noted while using the virtual tool as compared with hand gestures ( P <.05 for 5 of 6 poses). There were no substantial differences in the NASA Task Load Index scores. Conclusions: Use of a virtual tool (as a dynamic AR cue) enabled the mentee to follow the mentor’s instructions with fewer errors than both hand gestures and a 3D pointer without increasing cognitive workload. Further research is needed to assess the clinical effectiveness of the virtual tool during live surgery.
- Open Access
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 14, 67-76
Evaluation of User Interfaces for Actuated Control of Endoscopes During Flexible Endoscopy
Objective: Flexible endoscopy is a valuable tool in diagnostic procedures, enabling examination of internal areas via natural orifices. An actuation system tends to improve the procedural outcomes by enabling controlled movements of the endoscope and offering a stable view of the operative field. A user interface is used to issue actuation commands to these systems. Thus, selection of an ideal user interface is vital to improve the ergonomics for the endoscopist and to ensure efficient endoscope navigation. The objective of this work is to perform an in-depth comparative analysis of various user interfaces to optimize endoscope maneuverability. Methods and procedures: A custom-built actuation system was used to maneuver a flexible endoscope. The actuation system enabled translational and rotational movement of the endoscope’s shaft as well as supported left/right and up/down steering of the endoscope’s distal end. Four user interfaces (head-motion based device, eye-gaze based device, a stylus, and a joystick) working under three interaction modes (continuous, discrete, threshold) along with a clutching mechanism were used to issue commands to the actuation system. A user study was conducted to assess the effectiveness of the user interfaces for two scenarios: Scenario-A, which involved maneuvering the endoscope’s distal end to focus on a localized operative field, and Scenario-B, which required targeting polyps during the withdrawal phase of a simulated colonoscopy. Results: In Scenario-A, the head motion-based device and stylus, when used in continuous interaction mode, resulted in the shorter task duration and fewer clutches. The joystick, operating under threshold interaction mode, also demonstrated a reduced task duration. Additionally, the joystick led to fewer instances of the endoscope’s focus shifting outside the localized operative field. In Scenario-B, eye gaze-based device under discrete interaction mode took the longest duration for task completion. The continuous mode of the stylus took the shortest duration to target polyps, once visualized in the operating field. However, it also required the highest number of clutches compared to other user interface and interaction modes. Conclusion: The joystick consistently outperformed other interfaces across all interaction modes. Performance among the other user interfaces varied based on the parameters of the scenarios. Head motion-based and eye-based user interfaces enabled hands-free manipulation of the endoscope. This study establishes a benchmark for enhancing both user interfaces and interaction modes in actuated flexible endoscopy.
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 14, 67-76
Open AccessEvaluation of User Interfaces for Actuated Control of Endoscopes During Flexible Endoscopy
Objective: Flexible endoscopy is a valuable tool in diagnostic procedures, enabling examination of internal areas via natural orifices. An actuation system tends to improve the procedural outcomes by enabling controlled movements of the endoscope and offering a stable view of the operative field. A user interface is used to issue actuation commands to these systems. Thus, selection of an ideal user interface is vital to improve the ergonomics for the endoscopist and to ensure efficient endoscope navigation. The objective of this work is to perform an in-depth comparative analysis of various user interfaces to optimize endoscope maneuverability. Methods and procedures: A custom-built actuation system was used to maneuver a flexible endoscope. The actuation system enabled translational and rotational movement of the endoscope’s shaft as well as supported left/right and up/down steering of the endoscope’s distal end. Four user interfaces (head-motion based device, eye-gaze based device, a stylus, and a joystick) working under three interaction modes (continuous, discrete, threshold) along with a clutching mechanism were used to issue commands to the actuation system. A user study was conducted to assess the effectiveness of the user interfaces for two scenarios: Scenario-A, which involved maneuvering the endoscope’s distal end to focus on a localized operative field, and Scenario-B, which required targeting polyps during the withdrawal phase of a simulated colonoscopy. Results: In Scenario-A, the head motion-based device and stylus, when used in continuous interaction mode, resulted in the shorter task duration and fewer clutches. The joystick, operating under threshold interaction mode, also demonstrated a reduced task duration. Additionally, the joystick led to fewer instances of the endoscope’s focus shifting outside the localized operative field. In Scenario-B, eye gaze-based device under discrete interaction mode took the longest duration for task completion. The continuous mode of the stylus took the shortest duration to target polyps, once visualized in the operating field. However, it also required the highest number of clutches compared to other user interface and interaction modes. Conclusion: The joystick consistently outperformed other interfaces across all interaction modes. Performance among the other user interfaces varied based on the parameters of the scenarios. Head motion-based and eye-based user interfaces enabled hands-free manipulation of the endoscope. This study establishes a benchmark for enhancing both user interfaces and interaction modes in actuated flexible endoscopy.
- Open Access
- 19 November 2025
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 11 (1) , 1391-1413
In-situ spatio-temporal monitoring of heat transfer in pre-sintered powder in powder bed fusion: electron beam
In-situ sensing and monitoring techniques for heat transfer characterization in powder bed fusion have gained considerable attention within the additive manufacturing community. Indeed, by analysing heatmaps and thermal gradients, researchers aim to detect local anomalies and predict the resulting microstructural properties of the part. However, existing approaches focus on generating spatial and temporal heat maps only within regions of the powder bed where selective melting is applied. On the contrary, heat dissipation into the surrounding powder has received little or no investigation. Variations in heat transfer in the surrounding powder can adversely affect surface finish, dimensional accuracy, and microstructural consistency. To address this gap, the present study proposes a novel approach for in-situ monitoring of heat transfer outside the solidified area, specifically designed for powder bed fusion—electron beam (PBF-EB). The method integrates spatio-temporal modelling of the thermal history, based on a two-dimensional distance transform map, with a non-linear, low-dimensional learning technique capable of distinguishing between normal and anomalous heat transfer into the powder. The approach is demonstrated in a real PBF-EB case study using pure copper, a material whose pronounced thermal conductivity contrast between the consolidated bulk and the surrounding powder is a potential source of defects, thus motivating the study of new in-situ thermal monitoring strategies. Graphical abstract
- 19 November 2025
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 11 (1) , 1391-1413
Open AccessIn-situ spatio-temporal monitoring of heat transfer in pre-sintered powder in powder bed fusion: electron beam
In-situ sensing and monitoring techniques for heat transfer characterization in powder bed fusion have gained considerable attention within the additive manufacturing community. Indeed, by analysing heatmaps and thermal gradients, researchers aim to detect local anomalies and predict the resulting microstructural properties of the part. However, existing approaches focus on generating spatial and temporal heat maps only within regions of the powder bed where selective melting is applied. On the contrary, heat dissipation into the surrounding powder has received little or no investigation. Variations in heat transfer in the surrounding powder can adversely affect surface finish, dimensional accuracy, and microstructural consistency. To address this gap, the present study proposes a novel approach for in-situ monitoring of heat transfer outside the solidified area, specifically designed for powder bed fusion—electron beam (PBF-EB). The method integrates spatio-temporal modelling of the thermal history, based on a two-dimensional distance transform map, with a non-linear, low-dimensional learning technique capable of distinguishing between normal and anomalous heat transfer into the powder. The approach is demonstrated in a real PBF-EB case study using pure copper, a material whose pronounced thermal conductivity contrast between the consolidated bulk and the surrounding powder is a potential source of defects, thus motivating the study of new in-situ thermal monitoring strategies. Graphical abstract
- Open Access
- 20 May 2025
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Human-Robot Interaction
- Vol. 14 (3) , 1-20
Evaluating Human-Robot Interfaces for Maneuvering Surgical Laparoscopes using Robotic Scope Assistant Systems
Robotic scope assistant systems allow surgeons to adjust the operative field view during surgery by robotically maneuvering laparoscopes. A Human-Robot Interface (HRI) is used for issuing commands to these systems, with an interaction mode mapping these commands to laparoscope movements. Optimizing the HRI and interaction mode can streamline laparoscope positioning as well as reduce cognitive workload, helping the surgeon focus on the surgical procedure. Comparing and assessing various HRIs and interaction modes is essential for efficient laparoscope maneuvering. This study evaluates HRIs based on head-motion, eye-motion, hand-motion, and voice-input operating under three interaction modes (namely: discrete, continuous, and threshold). The participants performed a user study comparing different HRIs under two simulated surgical scenarios (one in a real environment and the other in a virtual environment). The results indicated that head and eye-based HRIs performed well in continuous interaction mode, while the voice-based interface suffered from a delay. Conversely, hand-based HRIs demonstrated superior performance in both scenarios across all evaluation parameters. The study provides a benchmark for the comparison of different HRIs and provides insights into the effectiveness, limitations, and potential advantages of different HRIs.
- 20 May 2025
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Human-Robot Interaction
- Vol. 14 (3) , 1-20
Open AccessEvaluating Human-Robot Interfaces for Maneuvering Surgical Laparoscopes using Robotic Scope Assistant Systems
Robotic scope assistant systems allow surgeons to adjust the operative field view during surgery by robotically maneuvering laparoscopes. A Human-Robot Interface (HRI) is used for issuing commands to these systems, with an interaction mode mapping these commands to laparoscope movements. Optimizing the HRI and interaction mode can streamline laparoscope positioning as well as reduce cognitive workload, helping the surgeon focus on the surgical procedure. Comparing and assessing various HRIs and interaction modes is essential for efficient laparoscope maneuvering. This study evaluates HRIs based on head-motion, eye-motion, hand-motion, and voice-input operating under three interaction modes (namely: discrete, continuous, and threshold). The participants performed a user study comparing different HRIs under two simulated surgical scenarios (one in a real environment and the other in a virtual environment). The results indicated that head and eye-based HRIs performed well in continuous interaction mode, while the voice-based interface suffered from a delay. Conversely, hand-based HRIs demonstrated superior performance in both scenarios across all evaluation parameters. The study provides a benchmark for the comparison of different HRIs and provides insights into the effectiveness, limitations, and potential advantages of different HRIs.
- 31 July 2024
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (1) , 629-645
Let UNet Play an Adversarial Game: Investigating the Effect of Adversarial Training in Enhancing Low-Resolution MRI
Adversarial training has attracted much attention in enhancing the visual realism of images, but its efficacy in clinical imaging has not yet been explored. This work investigated adversarial training in a clinical context, by training 206 networks on the OASIS-1 dataset for improving low-resolution and low signal-to-noise ratio (SNR) magnetic resonance images. Each network corresponded to a different combination of perceptual and adversarial loss weights and distinct learning rate values. For each perceptual loss weighting, we identified its corresponding adversarial loss weighting that minimized structural disparity. Each optimally weighted adversarial loss yielded an average SSIM reduction of 1.5%. We further introduced a set of new metrics to assess other clinically relevant image features: Gradient Error (GE) to measure structural disparities; Sharpness to compute edge clarity; and Edge-Contrast Error (ECE) to quantify any distortion of the pixel distribution around edges. Including adversarial loss increased structural enhancement in visual inspection, which correlated with statistically consistent GE reductions (p-value << 0.05). This also resulted in increased Sharpness; however, the level of statistical significance was dependent on the perceptual loss weighting. Additionally, adversarial loss yielded ECE reductions for smaller perceptual loss weightings, while showing non-significant increases (p-value >> 0.05) when these weightings were higher, demonstrating that the increased Sharpness does not adversely distort the pixel distribution around the edges in the image. These studies clearly suggest that adversarial training significantly improves the performance of an MRI enhancement pipeline, and highlights the need for systematic studies of hyperparameter optimization and investigation of alternative image quality metrics.
- 31 July 2024
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (1) , 629-645
Let UNet Play an Adversarial Game: Investigating the Effect of Adversarial Training in Enhancing Low-Resolution MRI
Adversarial training has attracted much attention in enhancing the visual realism of images, but its efficacy in clinical imaging has not yet been explored. This work investigated adversarial training in a clinical context, by training 206 networks on the OASIS-1 dataset for improving low-resolution and low signal-to-noise ratio (SNR) magnetic resonance images. Each network corresponded to a different combination of perceptual and adversarial loss weights and distinct learning rate values. For each perceptual loss weighting, we identified its corresponding adversarial loss weighting that minimized structural disparity. Each optimally weighted adversarial loss yielded an average SSIM reduction of 1.5%. We further introduced a set of new metrics to assess other clinically relevant image features: Gradient Error (GE) to measure structural disparities; Sharpness to compute edge clarity; and Edge-Contrast Error (ECE) to quantify any distortion of the pixel distribution around edges. Including adversarial loss increased structural enhancement in visual inspection, which correlated with statistically consistent GE reductions (p-value << 0.05). This also resulted in increased Sharpness; however, the level of statistical significance was dependent on the perceptual loss weighting. Additionally, adversarial loss yielded ECE reductions for smaller perceptual loss weightings, while showing non-significant increases (p-value >> 0.05) when these weightings were higher, demonstrating that the increased Sharpness does not adversely distort the pixel distribution around the edges in the image. These studies clearly suggest that adversarial training significantly improves the performance of an MRI enhancement pipeline, and highlights the need for systematic studies of hyperparameter optimization and investigation of alternative image quality metrics.
- 17 May 2024
- Published by Springer Nature
- p. 347-355
Bayesian Multimodal Data Analytics: AnIntroduction
- 10 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Relatable and Humorous Videos Reduce Hyperarousal in Math Exams
We report on a study investigating the sympathetic and performance effects of relatable humorous videos in undergraduate math exams. We recruited 20 lower division students to test this novel form of questioning. The students took a foundational math exam that included 12 items from each of the following three categories: Abstract A, Word W, and Video V, where A featured formula-based questions and W analytic questions expressed in plain descriptive form. The V category had questions similar to the W category, but expressed in relatable humorous video form. Sympathetic arousal was measured through facial electrodermal activity $({EDA}_{f})$ and heart rate $(HR)$, where the former was extracted via thermal imaging, and the latter through smartwatches. Results from both the ${EDA}_{f}$ and HR channels indicate that questions expressed in relatable humorous video form significantly curtail hyperarousal with respect to similar questions expressed in plain descriptive form. Furthermore, the study’s results suggest that exam performance is negatively affected by pre-exam anxiety, while is positively affected by generous time allotment. The said findings highlight the potential of V questions in making the math experience less stressful and more endearing to undergraduate students. Due to the importance of foundational math courses, such a change stands to bring downstream benefits to STEM education.- 10 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Relatable and Humorous Videos Reduce Hyperarousal in Math Exams
We report on a study investigating the sympathetic and performance effects of relatable humorous videos in undergraduate math exams. We recruited 20 lower division students to test this novel form of questioning. The students took a foundational math exam that included 12 items from each of the following three categories: Abstract A, Word W, and Video V, where A featured formula-based questions and W analytic questions expressed in plain descriptive form. The V category had questions similar to the W category, but expressed in relatable humorous video form. Sympathetic arousal was measured through facial electrodermal activity $({EDA}_{f})$ and heart rate $(HR)$, where the former was extracted via thermal imaging, and the latter through smartwatches. Results from both the ${EDA}_{f}$ and HR channels indicate that questions expressed in relatable humorous video form significantly curtail hyperarousal with respect to similar questions expressed in plain descriptive form. Furthermore, the study’s results suggest that exam performance is negatively affected by pre-exam anxiety, while is positively affected by generous time allotment. The said findings highlight the potential of V questions in making the math experience less stressful and more endearing to undergraduate students. Due to the importance of foundational math courses, such a change stands to bring downstream benefits to STEM education.- Open Access
- 30 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Affective Computing
- Vol. 15 (3) , 769-786
Investigating Cardiovascular Activation of Young Adults in Routine Driving
We report on a naturalistic study investigating the effects of routine driving on cardiovascular activation. We recruited 21 healthy young adults from a broad geographic area in the Southwestern United States. Using the participants' own smartphones and smartwatches, we monitored for a week both their driving and non-driving activities. Monitoring included the continuous recording of a) heart rate throughout the day, b) hand motion during driving as a proxy of persistent texting, and c) contextualized driving data, complete with traffic and weather information. These high temporal resolution variables were complemented with the drivers' biographic and psychometric profiles. Our analysis suggests that anxiety predisposition and high speeds are associated with significant cardiovascular activation on drivers, likely linked to sympathetic arousal. Surprisingly, these associations hold true under good weather, normal traffic, and with experienced drivers behind the wheel. The said findings call for attention to insidious effects of apparently benign drives even for people in their prime. Accordingly, our research contributes to intriguing new discourses on driving affect and personal health informatics.
- 30 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Affective Computing
- Vol. 15 (3) , 769-786
Open AccessInvestigating Cardiovascular Activation of Young Adults in Routine Driving
We report on a naturalistic study investigating the effects of routine driving on cardiovascular activation. We recruited 21 healthy young adults from a broad geographic area in the Southwestern United States. Using the participants' own smartphones and smartwatches, we monitored for a week both their driving and non-driving activities. Monitoring included the continuous recording of a) heart rate throughout the day, b) hand motion during driving as a proxy of persistent texting, and c) contextualized driving data, complete with traffic and weather information. These high temporal resolution variables were complemented with the drivers' biographic and psychometric profiles. Our analysis suggests that anxiety predisposition and high speeds are associated with significant cardiovascular activation on drivers, likely linked to sympathetic arousal. Surprisingly, these associations hold true under good weather, normal traffic, and with experienced drivers behind the wheel. The said findings call for attention to insidious effects of apparently benign drives even for people in their prime. Accordingly, our research contributes to intriguing new discourses on driving affect and personal health informatics.
- Open Access
- 19 April 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-8
Sympathetic Activation in Deadlines of Deskbound Research - A Study in the Wild
Paper and proposal deadlines are important milestones, conjuring up emotional memories to researchers. The question is if in the daily challenging world of scholarly research, deadlines truly incur higher sympathetic loading than the alternative. Here we report results from a longitudinal, in the wild study of n = 10 researchers working in the presence and absence of impeding deadlines. Unlike the retrospective, questionnaire-based studies of research deadlines in the past, our study is real-time and multimodal, including physiological, observational, and psychometric measurements. The results suggest that deadlines do not significantly add to the sympathetic loading of researchers. Irrespective of deadlines, the researchers’ sympathetic activation is strongly associated with the amount of reading and writing they do, the extent of smartphone use, and the frequency of physical breaks they take. The latter likely indicates a natural mechanism for regulating sympathetic overactivity in deskbound research, which can inform the design of future break interfaces.
- 19 April 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-8
Open AccessSympathetic Activation in Deadlines of Deskbound Research - A Study in the Wild
Paper and proposal deadlines are important milestones, conjuring up emotional memories to researchers. The question is if in the daily challenging world of scholarly research, deadlines truly incur higher sympathetic loading than the alternative. Here we report results from a longitudinal, in the wild study of n = 10 researchers working in the presence and absence of impeding deadlines. Unlike the retrospective, questionnaire-based studies of research deadlines in the past, our study is real-time and multimodal, including physiological, observational, and psychometric measurements. The results suggest that deadlines do not significantly add to the sympathetic loading of researchers. Irrespective of deadlines, the researchers’ sympathetic activation is strongly associated with the amount of reading and writing they do, the extent of smartphone use, and the frequency of physical breaks they take. The latter likely indicates a natural mechanism for regulating sympathetic overactivity in deskbound research, which can inform the design of future break interfaces.
- Open Access
- 27 January 2023
- Published by Taylor & Francis in Journal of Quality Technology
- Vol. 55 (4) , 404-421
Design and properties of the predictive ratio cusum (PRC) control charts
In statistical process control/monitoring (SPC/M), memory-based control charts aim to detect small/medium persistent parameter shifts. When a phase I calibration is not feasible, self-starting methods have been proposed, with the predictive ratio cusum (PRC) being one of them. To apply such methods in practice, one needs to derive the decision limit threshold that will guarantee a preset false alarm tolerance, a very difficult task when the process parameters are unknown and their estimate is sequentially updated. Utilizing the Bayesian framework in PRC, we will provide the theoretic framework that will allow to derive a decision-making threshold, based on false alarm tolerance, which along with the PRC closed-form monitoring scheme will permit its straightforward application in real-life practice. An enhancement of PRC is proposed, and a simulation study evaluates its robustness against competitors for various model type misspecifications. Finally, three real data sets (normal, Poisson, and binomial) illustrate its implementation in practice. Technical details, algorithms, and R-codes reproducing the illustrations are provided as supplementary material.
- 27 January 2023
- Published by Taylor & Francis in Journal of Quality Technology
- Vol. 55 (4) , 404-421
Open AccessDesign and properties of the predictive ratio cusum (PRC) control charts
In statistical process control/monitoring (SPC/M), memory-based control charts aim to detect small/medium persistent parameter shifts. When a phase I calibration is not feasible, self-starting methods have been proposed, with the predictive ratio cusum (PRC) being one of them. To apply such methods in practice, one needs to derive the decision limit threshold that will guarantee a preset false alarm tolerance, a very difficult task when the process parameters are unknown and their estimate is sequentially updated. Utilizing the Bayesian framework in PRC, we will provide the theoretic framework that will allow to derive a decision-making threshold, based on false alarm tolerance, which along with the PRC closed-form monitoring scheme will permit its straightforward application in real-life practice. An enhancement of PRC is proposed, and a simulation study evaluates its robustness against competitors for various model type misspecifications. Finally, three real data sets (normal, Poisson, and binomial) illustrate its implementation in practice. Technical details, algorithms, and R-codes reproducing the illustrations are provided as supplementary material.