PRParineak Romtrairat
Parineak Romtrairat
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Parineak Romtrairat has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chanyaphan Virulsri
Center of Excellence for Prosthetic and Orthopedic Implant, Chulalongkorn University, Bangkok, Thailand
2 shared publications - Pairat Tangpornprasert
Center of Excellence for Prosthetic and Orthopedic Implant, Chulalongkorn University, Bangkok, Thailand
2 shared publications - Gridsada Phanomchoeng
Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand
1 shared publication Kaweepak Satjasai
Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
1 shared publicationKhem Submee
Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
1 shared publicationMatniwit Chariyasethapong
Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
1 shared publication
Latest Publications
- Open Access
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 140546-140558
Development of Plucked Piezoelectric Energy Harvesting From Human’s Upper Limb Motion
This paper presents the design, modeling, and implementation of a plucked piezoelectric energy harvester (PEH) optimized for human elbow motion. The proposed system leverages the advantages of upper-limb biomechanics, particularly elbow flexion during walking, to generate electrical energy suitable for powering wearable electronics. A compact bimorph PZT-based PEH was selected and integrated with a mechanical plucking mechanism to enable frequency up-conversion from low-frequency body motion to high-frequency piezoelectric vibration. An electromechanical model predicting the electrical output and energy harvesting performance of a plucked PEH system was developed using Hamilton’s Principle and validated through experiments, showing strong agreement in voltage response and energy output. Implemented in MATLAB/Simulink, the model also served as a design tool for parametric optimization, allowing efficient tuning of system parameters prior to prototyping. Furthermore, parameter optimization through experimental tests identified a plucking distance of 0.16 mm and a load resistance of$800\Omega $ as optimal for the decided bimorph PZT in energy harvesting. The developed prototype successfully demonstrated repeatable energy generation ranging from 22–$33~\mu $ J per elbow movement cycle under simulated motion. This work offers a validated framework for future development of energy-autonomous wearable devices that are lightweight, compact, and ergonomically compatible.- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 140546-140558
Open AccessDevelopment of Plucked Piezoelectric Energy Harvesting From Human’s Upper Limb Motion
This paper presents the design, modeling, and implementation of a plucked piezoelectric energy harvester (PEH) optimized for human elbow motion. The proposed system leverages the advantages of upper-limb biomechanics, particularly elbow flexion during walking, to generate electrical energy suitable for powering wearable electronics. A compact bimorph PZT-based PEH was selected and integrated with a mechanical plucking mechanism to enable frequency up-conversion from low-frequency body motion to high-frequency piezoelectric vibration. An electromechanical model predicting the electrical output and energy harvesting performance of a plucked PEH system was developed using Hamilton’s Principle and validated through experiments, showing strong agreement in voltage response and energy output. Implemented in MATLAB/Simulink, the model also served as a design tool for parametric optimization, allowing efficient tuning of system parameters prior to prototyping. Furthermore, parameter optimization through experimental tests identified a plucking distance of 0.16 mm and a load resistance of$800\Omega $ as optimal for the decided bimorph PZT in energy harvesting. The developed prototype successfully demonstrated repeatable energy generation ranging from 22–$33~\mu $ J per elbow movement cycle under simulated motion. This work offers a validated framework for future development of energy-autonomous wearable devices that are lightweight, compact, and ergonomically compatible. - 1 April 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 87, 183-188
An application of scissored-pair control moment gyroscopes in a design of wearable balance assistance device for the elderly
- 1 April 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 87, 183-188
An application of scissored-pair control moment gyroscopes in a design of wearable balance assistance device for the elderly
- 1 March 2015
- Published by Elsevier in Materials & Design (1980-2015)
- Vol. 68, 1-7
Femoral hip prosthesis design for Thais using multi-objective shape optimization
- 1 March 2015
- Published by Elsevier in Materials & Design (1980-2015)
- Vol. 68, 1-7