Marco Vinicio Chavez Baez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marco Vinicio Chavez Baez has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Enrique Reyes-Archundia
Instituto Tecnológico de Morelia
5 shared publications - Jose Antonio Gutierrez Gnecchi
Instituto Tecnológico de Morelia
5 shared publications - Javier Rodríguez-Herrejón
Division for Postgraduate Studies, Technological Institute of Morelia, Morelia, Mexico
4 shared publications - Nestor Francisco Guerrero-Rodríguez
Facultad de Ciencias e Ingeniería, Pontificia Universidad Católica Madre y Maestra (PUCMM), Santo Domingo 10109, Dominican Republic
3 shared publications Jim McDonald
Strathclyde University, UK
2 shared publications- Jonatan A. Medina-Molina
National Technological Institute of Mexico (TecNM), Technological Institute of Morelia (ITM)
2 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by GSC Online Press in Global Journal of Engineering and Technology Advances
- Vol. 29 (2) , 001-011
SEVEN-CLASS LOWER-LIMB ACTIVITY RECOGNITION USING THREE-CHANNEL SEMG
Three-channel sEMG recordings may contain different signatures of lower-limb activity, but separating movements is less straightforward when they recruit some of the same muscles. We examined this problem in seven right-leg activities using the conditioned envelopes recorded over rectus femoris, vastus lateralis, and semitendinosus. The experiment comprised five repeated movements and two sustained postures, each recorded for 40 s during one session with a 25-year-old participant without amputation. We divided the recordings into 300-ms windows with 60% overlap, extracted seven time-domain descriptors, and used them in a support vector machine (SVM). The stored test matrix contains 464 windows and 401 correct assignments, corresponding to 86.42% accuracy. The findings describe the discrimination achieved with the selected channels and indicate aspects of electrode placement and cycle labeling that warrant further testing.
- 1 November 2026
- Published by GSC Online Press in Global Journal of Engineering and Technology Advances
- Vol. 29 (2) , 001-011
Open AccessSEVEN-CLASS LOWER-LIMB ACTIVITY RECOGNITION USING THREE-CHANNEL SEMG
Three-channel sEMG recordings may contain different signatures of lower-limb activity, but separating movements is less straightforward when they recruit some of the same muscles. We examined this problem in seven right-leg activities using the conditioned envelopes recorded over rectus femoris, vastus lateralis, and semitendinosus. The experiment comprised five repeated movements and two sustained postures, each recorded for 40 s during one session with a 25-year-old participant without amputation. We divided the recordings into 300-ms windows with 60% overlap, extracted seven time-domain descriptors, and used them in a support vector machine (SVM). The stored test matrix contains 464 windows and 401 correct assignments, corresponding to 86.42% accuracy. The findings describe the discrimination achieved with the selected channels and indicate aspects of electrode placement and cycle labeling that warrant further testing.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 5, 3000309
Experimental Analysis of Short Acquisition Windows in Low-Latency Embedded Power Quality Disturbance Classification
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 5, 3000309
Open AccessExperimental Analysis of Short Acquisition Windows in Low-Latency Embedded Power Quality Disturbance Classification
- Open Access
- 28 October 2025
- Published by Oxford University Press (OUP) in Clean Energy
- Vol. 10 (1) , 94-105
Experimental design and validation of a domestic solar-powered water pumping system for urban areas with irregular supply
In many urban areas of Morelia, Michoacán, the water supply is intermittent, compelling residents to store water in cisterns and pump it to rooftop tanks using conventional electric systems. This study proposes the design and experimental validation of a domestic solar photovoltaic water pumping system as a sustainable and cost-effective solution for regions with irregular water supply. A sizing methodology is presented, which accounts for the required water volume, flow rate based on solar hours, barometric head, and losses due to friction and fittings. To validate the proposed system, an experimental case study was conducted using a 330 W PV panel, a 300 W buck converter, and a 48 W pump, achieving a flow rate of 6.9 L/min and a total dynamic head of 12.57 m. The results show that under real operating conditions, the system demonstrated an efficiency of 29.9% and a service capacity of 4.14 individuals per hour of effective sunlight or 1208.8 m3 per year considering 8 hours of effective sunlight. In addition, the experimental results were validated using the PVSyst simulator, which indicated an annual pumped water of 1204 m3 per year, which closely matches with the experimental results. The results confirm the technical feasibility of the proposed alternative to improve water access in vulnerable urban areas with irregular supply.
- 28 October 2025
- Published by Oxford University Press (OUP) in Clean Energy
- Vol. 10 (1) , 94-105
Open AccessExperimental design and validation of a domestic solar-powered water pumping system for urban areas with irregular supply
In many urban areas of Morelia, Michoacán, the water supply is intermittent, compelling residents to store water in cisterns and pump it to rooftop tanks using conventional electric systems. This study proposes the design and experimental validation of a domestic solar photovoltaic water pumping system as a sustainable and cost-effective solution for regions with irregular water supply. A sizing methodology is presented, which accounts for the required water volume, flow rate based on solar hours, barometric head, and losses due to friction and fittings. To validate the proposed system, an experimental case study was conducted using a 330 W PV panel, a 300 W buck converter, and a 48 W pump, achieving a flow rate of 6.9 L/min and a total dynamic head of 12.57 m. The results show that under real operating conditions, the system demonstrated an efficiency of 29.9% and a service capacity of 4.14 individuals per hour of effective sunlight or 1208.8 m3 per year considering 8 hours of effective sunlight. In addition, the experimental results were validated using the PVSyst simulator, which indicated an annual pumped water of 1204 m3 per year, which closely matches with the experimental results. The results confirm the technical feasibility of the proposed alternative to improve water access in vulnerable urban areas with irregular supply.
- Open Access
Optimal Selection of Sampling Rates and Mother Wavelet for an Algorithm to Classify Power Quality Disturbances
The introduction of renewable energy sources, distributed energy systems, and power electronics equipment has led to the emergence of the Smart Grid. However, these developments have also caused the worsening of power quality. Selecting the correct sampling frequency and feature extraction techniques are essential for appropriately analyzing power quality disturbances. This work compares the performance of an algorithm based on a Support Vector Machine and Discrete Wavelet Transform for the classification of power quality disturbances using eight sampling rates and five different mother wavelets. The algorithm was tested in noisy and noiseless scenarios to show the methodology. The results indicate that a success rate of 99.9% is obtained for the noiseless signals using a sampling rate of 9.6 kHz and 95.2% for signals with a signal-to-noise ratio of 30 dB with a sampling rate of 30 kHz.
Open AccessOptimal Selection of Sampling Rates and Mother Wavelet for an Algorithm to Classify Power Quality Disturbances
The introduction of renewable energy sources, distributed energy systems, and power electronics equipment has led to the emergence of the Smart Grid. However, these developments have also caused the worsening of power quality. Selecting the correct sampling frequency and feature extraction techniques are essential for appropriately analyzing power quality disturbances. This work compares the performance of an algorithm based on a Support Vector Machine and Discrete Wavelet Transform for the classification of power quality disturbances using eight sampling rates and five different mother wavelets. The algorithm was tested in noisy and noiseless scenarios to show the methodology. The results indicate that a success rate of 99.9% is obtained for the noiseless signals using a sampling rate of 9.6 kHz and 95.2% for signals with a signal-to-noise ratio of 30 dB with a sampling rate of 30 kHz.
- 1 February 2025
- Published by Elsevier in Applied Soft Computing
- Vol. 171
Methodology for online detection and classification of power quality disturbances based on FPGA
- 1 February 2025
- Published by Elsevier in Applied Soft Computing
- Vol. 171
Methodology for online detection and classification of power quality disturbances based on FPGA
- Open Access
- 19 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 59901-59908
Hardware in the Loop Protection Scheme of Compensated Transmission Lines With a Unified Power Flow Controller
This paper presents a Hardware in the Loop simulation for the detection, classification, and location of faults in transmission lines with Unified Power Flow Controller compensation. Hardware devices are proposed to demonstrate that the traveling wave concept for fault location in a Hardware in the Loop simulation is possible and replicable under laboratory conditions. The devices used are a MacBook Air M1 2020 computer to get the SIMULINK values from the local end of the transmission line, two FeelElec FY8300S generators to import the simulation data, then they send the signals to an AT91SAM3X8E microcontroller to perform the fault detection, when the cycle of the signals where the fault is obtained, they are sent to the UDOO BOLT v8 device to get the classification and location of the fault. The results obtained indicate that the error for estimating the fault distance is less than 0.71% of the total line length, and the classification efficiency is 94.18%.
- 19 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 59901-59908
Open AccessHardware in the Loop Protection Scheme of Compensated Transmission Lines With a Unified Power Flow Controller
This paper presents a Hardware in the Loop simulation for the detection, classification, and location of faults in transmission lines with Unified Power Flow Controller compensation. Hardware devices are proposed to demonstrate that the traveling wave concept for fault location in a Hardware in the Loop simulation is possible and replicable under laboratory conditions. The devices used are a MacBook Air M1 2020 computer to get the SIMULINK values from the local end of the transmission line, two FeelElec FY8300S generators to import the simulation data, then they send the signals to an AT91SAM3X8E microcontroller to perform the fault detection, when the cycle of the signals where the fault is obtained, they are sent to the UDOO BOLT v8 device to get the classification and location of the fault. The results obtained indicate that the error for estimating the fault distance is less than 0.71% of the total line length, and the classification efficiency is 94.18%.
- 9 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6, 1-5
Detection and Classification of Faults in Transmission Lines Compensated with TCSC in the Time Domain
Thyristor controlled series compensation (TCSC) is widely used in long transmission lines to mainly improve power transfer capability. However, TCSC produces complicated impedance that negatively affects distance protection operation. This paper presents a mathematical model in the time domain to achieve the detection of the fault in a compensated line instead of an analysis in the frequency domain. In addition, a probabilistic neural networks classifier is used to classify the different 11 types of faults, between the lines: AB, AC, BC, AG, BG, CG, ABG, ACG, BCG, ABC and ABCG, with different values in the resistance of the fault and different inception angle. The proposed algorithm is capable to detect the moment in which the failure occurs in the signals of the voltage lines. The probabilistic neural networks were trained using 317 and tested using 79 results under different conditions obtaining 72 true positives and 7 false positives in the classification, therefore the relative error was as 0.0886, the classifier has a precision of 0.9113.
- 9 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6, 1-5
Detection and Classification of Faults in Transmission Lines Compensated with TCSC in the Time Domain
Thyristor controlled series compensation (TCSC) is widely used in long transmission lines to mainly improve power transfer capability. However, TCSC produces complicated impedance that negatively affects distance protection operation. This paper presents a mathematical model in the time domain to achieve the detection of the fault in a compensated line instead of an analysis in the frequency domain. In addition, a probabilistic neural networks classifier is used to classify the different 11 types of faults, between the lines: AB, AC, BC, AG, BG, CG, ABG, ACG, BCG, ABC and ABCG, with different values in the resistance of the fault and different inception angle. The proposed algorithm is capable to detect the moment in which the failure occurs in the signals of the voltage lines. The probabilistic neural networks were trained using 317 and tested using 79 results under different conditions obtaining 72 true positives and 7 false positives in the classification, therefore the relative error was as 0.0886, the classifier has a precision of 0.9113.
- 9 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6, 1-6
Transducer Based on Current Transfer Ratio of Optocouplers to Smart Electricity Meters
Voltage and current sensors are the first keys in smart electricity meter design. They must meet accuracy, security, and reliability. Hence, these sensors become sophisticated and expensive. This paper proposes a transducer not only to meet charge electricity billing, but also to acquire waveforms to evaluate adverse power quality phenomena. The proposed transducer is based on an optocoupler to isolate the electrical network from the meter. The transducer design uses a suggested method to exploit properly the current transfer ratio to meet the accuracy and linearity needed in the power quality context. In addition, a method to estimate a correction factor to compensate for the tolerance in the component values of the transducer is given. The proposed transducer has been validated using Oread Lite® software to simulate different case studies related to power quality phenomena. Results show that the proposed transducer has an adequate performance for smart electricity meters that can be extended to evaluate adverse power quality phenomena.
- 9 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6, 1-6
Transducer Based on Current Transfer Ratio of Optocouplers to Smart Electricity Meters
Voltage and current sensors are the first keys in smart electricity meter design. They must meet accuracy, security, and reliability. Hence, these sensors become sophisticated and expensive. This paper proposes a transducer not only to meet charge electricity billing, but also to acquire waveforms to evaluate adverse power quality phenomena. The proposed transducer is based on an optocoupler to isolate the electrical network from the meter. The transducer design uses a suggested method to exploit properly the current transfer ratio to meet the accuracy and linearity needed in the power quality context. In addition, a method to estimate a correction factor to compensate for the tolerance in the component values of the transducer is given. The proposed transducer has been validated using Oread Lite® software to simulate different case studies related to power quality phenomena. Results show that the proposed transducer has an adequate performance for smart electricity meters that can be extended to evaluate adverse power quality phenomena.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Review of harmonics in offshore wind farms
This paper presents a review of harmonics in offshore wind farm systems. The aim is to gather information of mathematical models for harmonic analysis in wind farms and algorithms to configure offshore network interconnections. A thorough literature review is presented that may help to develop a solution in MatLab or LabView for harmonic analysis in offshore wind farms with multi-technology components.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Review of harmonics in offshore wind farms
This paper presents a review of harmonics in offshore wind farm systems. The aim is to gather information of mathematical models for harmonic analysis in wind farms and algorithms to configure offshore network interconnections. A thorough literature review is presented that may help to develop a solution in MatLab or LabView for harmonic analysis in offshore wind farms with multi-technology components.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Harmonics and power loss reduction in multi-technology offshore wind farms using simplex method
This paper presents an algorithm, based on the simplex method, to reconfigure distribution systems minimizing harmonics and power losses. The algorithm is implemented in LabView and calculates the power flow and the harmonics flow, then uses the simplex method to obtain the maximum current flow, in a second stage the data is saved for each configuration, and finally with all the data, the algorithm suggests the best configuration with less total harmonic distortion and less power losses.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Harmonics and power loss reduction in multi-technology offshore wind farms using simplex method
This paper presents an algorithm, based on the simplex method, to reconfigure distribution systems minimizing harmonics and power losses. The algorithm is implemented in LabView and calculates the power flow and the harmonics flow, then uses the simplex method to obtain the maximum current flow, in a second stage the data is saved for each configuration, and finally with all the data, the algorithm suggests the best configuration with less total harmonic distortion and less power losses.