David Nolte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Nolte has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Cristóbal Bertoglio
University of Groningen
5 shared publications - Reidmen Aróstica
Bernoulli Institute, University of Groningen
2 shared publications - Aaron L. Brown
Department of Mechanical Engineering, Stanford University, Stanford, CA, USA
1 shared publication Alison Marsden
1 shared publication- Amadeus M. Gebauer
Institute for Computational Mechanics, Department of Engineering Physics & Computation, TUM School of Engineering and Design Technical University of Munich Garching Germany
1 shared publication - Araceli Gago-Arias
Group of Medical Physics and Biomathematics, Instituto de Investigación Sanitaria de Santiago (IDIS), 15706 Santiago de Compostela, Spain
1 shared publication
Latest Publications
- Open Access
- 6 April 2026
- Published by The Open Journal in Journal of Open Source Software
- Vol. 11 (120)
TransiFlow: A Python package for performing bifurcation analysis on fluid flow problems
- 6 April 2026
- Published by The Open Journal in Journal of Open Source Software
- Vol. 11 (120)
Open AccessTransiFlow: A Python package for performing bifurcation analysis on fluid flow problems
- Open Access
- 25 February 2026
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 454
Duct boundary conditions for incompressible fluid flows: Finite element discretizations and parameter estimation in coronary blood flow
- 25 February 2026
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 454
Open AccessDuct boundary conditions for incompressible fluid flows: Finite element discretizations and parameter estimation in coronary blood flow
- 29 May 2025
- Published by Springer Nature
- p. 378-389
Parameter Estimation in Cardiac Fluid–Structure Interaction from Fluid and Solid Measurements
- 29 May 2025
- Published by Springer Nature
- p. 378-389
Parameter Estimation in Cardiac Fluid–Structure Interaction from Fluid and Solid Measurements
- Open Access
- 19 December 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 435
A software benchmark for cardiac elastodynamics
- 19 December 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 435
Open AccessA software benchmark for cardiac elastodynamics
- 1 February 2020
- Published by Elsevier in Physica Medica
- Vol. 70, 109-117
Simulation of hypoxia PET-tracer uptake in tumours: Dependence of clinical uptake-values on transport parameters and arterial input function
- 1 February 2020
- Published by Elsevier in Physica Medica
- Vol. 70, 109-117
Simulation of hypoxia PET-tracer uptake in tumours: Dependence of clinical uptake-values on transport parameters and arterial input function
- Open Access
- 1 April 2019
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 35 (6) , e3203
Reducing the impact of geometric errors in flow computations using velocity measurements
Numerical blood flow simulations are typically set up from anatomical medical images and calibrated using velocity measurements. However, the accuracy of the computational geometry itself is limited by the resolution of the anatomical image. We first show that applying standard no‐slip boundary conditions on inaccurately extracted boundaries can cause large errors in the results, in particular the pressure gradient. In this work, we therefore propose to augment the flow model calibration by slip/transpiration boundary conditions, whose parameters are then estimated using velocity measurements. Numerical experiments show that this methodology can considerably improve the accuracy of the estimated pressure gradients and 3D velocity fields when the vessel geometry is uncertain.
- 1 April 2019
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 35 (6) , e3203
Open AccessReducing the impact of geometric errors in flow computations using velocity measurements
Numerical blood flow simulations are typically set up from anatomical medical images and calibrated using velocity measurements. However, the accuracy of the computational geometry itself is limited by the resolution of the anatomical image. We first show that applying standard no‐slip boundary conditions on inaccurately extracted boundaries can cause large errors in the results, in particular the pressure gradient. In this work, we therefore propose to augment the flow model calibration by slip/transpiration boundary conditions, whose parameters are then estimated using velocity measurements. Numerical experiments show that this methodology can considerably improve the accuracy of the estimated pressure gradients and 3D velocity fields when the vessel geometry is uncertain.
- 1 January 2019
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Applied Mathematics
- Vol. 79 (3) , 959-985
Junction of Models of Different Dimension for Flows in Tube Structures by Womersley-Type Interface Conditions
The method of asymptotic partial decomposition of a domain proposed and justified earlier for thin domains (rod structures, tube structures consisting of a set of thin cylinders) generates some spe...
- 1 January 2019
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Applied Mathematics
- Vol. 79 (3) , 959-985
Junction of Models of Different Dimension for Flows in Tube Structures by Womersley-Type Interface Conditions
The method of asymptotic partial decomposition of a domain proposed and justified earlier for thin domains (rod structures, tube structures consisting of a set of thin cylinders) generates some spe...