Haroon Tayyab
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haroon Tayyab has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Muhammad H. Ali
Ophthalmology, Vitreoretinal Surgery, Allama Iqbal Medical College/Jinnah Hospital, Lahore, PAK
1 shared publication Qasim Lateef
Ophthalmology, Vitreoretinal Surgery, Allama Iqbal Medical College/Jinnah Hospital, Lahore, PAK
1 shared publicationSaima Jamil
Surgery/Ophthalmology, The Aga Khan University Hospital, Karachi, PAK
1 shared publication- Sana Jahangir
Ophthalmology, Vitreoretinal Surgery, Allama Iqbal Medical College/Jinnah Hospital, Lahore, PAK
1 shared publication - Shiraz Hashmi
Senior Instructor, Department of Surgery, Aga Khan University Hospital, Karachi, Pakistan
1 shared publication - Tehmina Jahangir
Ophthalmology, Vitreoretinal Surgery, Lahore General Hospital, Lahore, PAK
1 shared publication
Latest Publications
- Open Access
- 25 August 2021
- Published by Springer Nature in Cureus
- Vol. 13 (8)
Use of Intravitreal Methotrexate Infusion in Complicated Retinal Detachment for Prevention of Proliferative Vitreoretinopathy in a Pilot Study
The objective of this pilot study was to evaluate the efficacy and safety of per-operative intravitreal methotrexate (MTX) infusion during vitrectomy in patients of retinal detachment (RD) with advanced grade proliferative vitreoretinopathy (PVR). In this prospective interventional case series, we included patients with Grade C PVR, recurrent RD, and open globe trauma. All patients underwent standard single surgeon operated 23-gauge pars plana vitrectomy (PPV) with 80mg of MTX in 1000mL of irrigation fluid. All patients were followed up after four months to assess the final status of retinal attachment and visual acuity. Ethical review board permission was sought for this off-label use of MTX and all patients signed an informed consent form before this intervention. Thirty eyes of 30 patients with recurrent retinal detachment, open globe trauma, or grade C PVR at initial presentation were included in this study. After PPV, these patients were followed up after four months. A total of 24 (80%) patients maintained retinal attachment at four months. Mean preoperative best-corrected visual acuity (BCVA) was 1.35 logarithm of the minimum angle of resolution (logMAR) (range 0.5-3) and mean four months postoperative BCVA was 1.01 logMAR (range 0.3-3) (Student’s t-test; P-value <0.05). Seventeen (56.6%) eyes had pre-operative BCVA of 1.0 whereas 25 (83.3%) had BCVA of 1.0 at the end of the follow-up period. Six (20%) patients had preoperative BCVA of 0.7 whereas 12 (40%) patients had BCVA of 0.7 at four months postoperatively. Out of six (20%) eyes developing RD after this intervention, four eyes achieved retinal reattachment after a second surgery. We did not observe any MTX-related complications during the follow-up period of this study. Intravitreal MTX infusion during PPV for complicated RD as an adjunctive therapy showed encouraging results and was found to be safe in its use. We need more rigorous and controlled studies to confirm the possible advantages of MTX and its role in the prevention of PVR.
- 25 August 2021
- Published by Springer Nature in Cureus
- Vol. 13 (8)
Open AccessUse of Intravitreal Methotrexate Infusion in Complicated Retinal Detachment for Prevention of Proliferative Vitreoretinopathy in a Pilot Study
The objective of this pilot study was to evaluate the efficacy and safety of per-operative intravitreal methotrexate (MTX) infusion during vitrectomy in patients of retinal detachment (RD) with advanced grade proliferative vitreoretinopathy (PVR). In this prospective interventional case series, we included patients with Grade C PVR, recurrent RD, and open globe trauma. All patients underwent standard single surgeon operated 23-gauge pars plana vitrectomy (PPV) with 80mg of MTX in 1000mL of irrigation fluid. All patients were followed up after four months to assess the final status of retinal attachment and visual acuity. Ethical review board permission was sought for this off-label use of MTX and all patients signed an informed consent form before this intervention. Thirty eyes of 30 patients with recurrent retinal detachment, open globe trauma, or grade C PVR at initial presentation were included in this study. After PPV, these patients were followed up after four months. A total of 24 (80%) patients maintained retinal attachment at four months. Mean preoperative best-corrected visual acuity (BCVA) was 1.35 logarithm of the minimum angle of resolution (logMAR) (range 0.5-3) and mean four months postoperative BCVA was 1.01 logMAR (range 0.3-3) (Student’s t-test; P-value <0.05). Seventeen (56.6%) eyes had pre-operative BCVA of 1.0 whereas 25 (83.3%) had BCVA of 1.0 at the end of the follow-up period. Six (20%) patients had preoperative BCVA of 0.7 whereas 12 (40%) patients had BCVA of 0.7 at four months postoperatively. Out of six (20%) eyes developing RD after this intervention, four eyes achieved retinal reattachment after a second surgery. We did not observe any MTX-related complications during the follow-up period of this study. Intravitreal MTX infusion during PPV for complicated RD as an adjunctive therapy showed encouraging results and was found to be safe in its use. We need more rigorous and controlled studies to confirm the possible advantages of MTX and its role in the prevention of PVR.
- Open Access
- 14 May 2021
- Published by Springer Nature in Cureus
- Vol. 13 (5)
In Vitro Comparison of Various High-Speed Vitrectomy Machines Using Dual Blade Cutters
The objective of this study is to compare various dual blade vitrectomy cutters for their efficiency in an in vitro setting. In this in vitro experimental study, we compared various vitrectomy systems including EVA (Dutch Ophthalmic Research Center, Zuidland, The Netherlands), REVOLUTION (Optikon 2000, Inc., Rome, Italy), and OS4 (Oertli Instrumente AG, Berneck, Switzerland) in terms of efficiency in vitreous cutting and aspiration for various vitreous substitutes. These substitutes included water, chicken egg albumin, and goat vitreous. We only used 23-gauge dual blade cutters across all platforms to maintain uniformity. The cutting and aspiration efficiency was measured across various cut and vacuum settings of vitrectomy machines and measured as mass aspirated in a given time. Data analysis included comparing the amount of mass aspirated by these machines at preset cut and vacuum settings. Scatter plots showed a comparable mass of water aspirated by the EVA and REVOLUTION at 1000 to 5000 cuts per minute at a constant vacuum of 500 mm Hg whereas OS4 aspirated lesser mass at similar settings. Same trends were noted for goat vitreous for EVA and REVOLUTION but aspirated mass of albumin fluctuated widely across various platforms. At peak machine settings, REVOLUTION showed superiority across all three vitreous models due to its higher peak settings. The area under curve (AUC) analysis showed no significant differences among machines for water and goat vitreous at comparable settings but results were fluctuating for egg albumin. Employing higher cut rates for dual blade cutters results in better efficiency of vitrectomy machines.
- 14 May 2021
- Published by Springer Nature in Cureus
- Vol. 13 (5)
Open AccessIn Vitro Comparison of Various High-Speed Vitrectomy Machines Using Dual Blade Cutters
The objective of this study is to compare various dual blade vitrectomy cutters for their efficiency in an in vitro setting. In this in vitro experimental study, we compared various vitrectomy systems including EVA (Dutch Ophthalmic Research Center, Zuidland, The Netherlands), REVOLUTION (Optikon 2000, Inc., Rome, Italy), and OS4 (Oertli Instrumente AG, Berneck, Switzerland) in terms of efficiency in vitreous cutting and aspiration for various vitreous substitutes. These substitutes included water, chicken egg albumin, and goat vitreous. We only used 23-gauge dual blade cutters across all platforms to maintain uniformity. The cutting and aspiration efficiency was measured across various cut and vacuum settings of vitrectomy machines and measured as mass aspirated in a given time. Data analysis included comparing the amount of mass aspirated by these machines at preset cut and vacuum settings. Scatter plots showed a comparable mass of water aspirated by the EVA and REVOLUTION at 1000 to 5000 cuts per minute at a constant vacuum of 500 mm Hg whereas OS4 aspirated lesser mass at similar settings. Same trends were noted for goat vitreous for EVA and REVOLUTION but aspirated mass of albumin fluctuated widely across various platforms. At peak machine settings, REVOLUTION showed superiority across all three vitreous models due to its higher peak settings. The area under curve (AUC) analysis showed no significant differences among machines for water and goat vitreous at comparable settings but results were fluctuating for egg albumin. Employing higher cut rates for dual blade cutters results in better efficiency of vitrectomy machines.