Zhifan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhifan Li has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Qijun Deng
Wuhan University
11 shared publications - Qiming Huang
School of Robotics, Wuhan University, Wuhan, China
6 shared publications - Jiangtao Liu
School of Physical, Mechanical and Electrical Engineering, Hubei University of Education, Wuhan, China
5 shared publications - Shuaiqi Li
Hubei Key Laboratory of Power Equipment & System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
5 shared publications - Wenshan Hu
School of Robotics, Wuhan University, Wuhan 430072, China
5 shared publications Haozhe Deng
Wuhan Britain-China School, Wuhan, China
3 shared publications
Latest Publications
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (4) , 6277-6287
Model Predictive Control of Output Voltage for DWPT System Based on Closed-Loop Identification of LPV Model
The dynamic wireless power transfer (DWPT) system helps to alleviate range anxiety in electric vehicles. For the secondary side constant power output control strategy of DWPT, the operating point of dc–dc converter has wide range variations due to mutual inductance fluctuation, conventional small signal model fails to capture its dynamic behavior, whereas the parameter identification-based linear parameter-varying (LPV) model resolves this limitation. Furthermore, to leverage the rapid-response and time-varying model handling capability of model predictive control (MPC), it is applied for constant voltage (CV) control of the LPV-modeled dc–dc converter. To maintain model accuracy during load variations, the data-driven closed-loop identification (CLID) framework by simplified refined instrumental variable algorithm is proposed, enabling model updates without breaking the control loop. Experiments confirm that the proposed LPV-MPC method maintains stable output voltage (fluctuation$<$2.5%) in high-speed DWPT systems with over 60% mutual inductance variation range. And the CLID and model update effectively mitigate control performance deterioration caused by outdated model, which ensures sufficient CV control throughout the full charging cycle of battery.
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (4) , 6277-6287
Model Predictive Control of Output Voltage for DWPT System Based on Closed-Loop Identification of LPV Model
The dynamic wireless power transfer (DWPT) system helps to alleviate range anxiety in electric vehicles. For the secondary side constant power output control strategy of DWPT, the operating point of dc–dc converter has wide range variations due to mutual inductance fluctuation, conventional small signal model fails to capture its dynamic behavior, whereas the parameter identification-based linear parameter-varying (LPV) model resolves this limitation. Furthermore, to leverage the rapid-response and time-varying model handling capability of model predictive control (MPC), it is applied for constant voltage (CV) control of the LPV-modeled dc–dc converter. To maintain model accuracy during load variations, the data-driven closed-loop identification (CLID) framework by simplified refined instrumental variable algorithm is proposed, enabling model updates without breaking the control loop. Experiments confirm that the proposed LPV-MPC method maintains stable output voltage (fluctuation$<$2.5%) in high-speed DWPT systems with over 60% mutual inductance variation range. And the CLID and model update effectively mitigate control performance deterioration caused by outdated model, which ensures sufficient CV control throughout the full charging cycle of battery.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (1) , 1302-1311
Output Voltage Fluctuation Mitigation of CPT Based on LPV Modeling and Robust Control
This paper investigates a LPV-based output voltage mitigation method for the capacitive wireless power transfer (CPT) system employing a series Buck converter under varying mutual capacitance conditions. A linear parameter varying (LPV) model is utilized to represent the dynamics of the Buck converter under input voltage fluctuations. Based on the estimated model, a robust controller is designed using the normalized coprime factorization (NCF) approach to ensure system stability and performance. Experimental results demonstrate the effectiveness of the proposed method. The system achieves rapid voltage regulation and maintains stable output voltage under various disturbance frequencies and load conditions. These findings validate the robustness and adaptability of the proposed control strategy, offering a reliable solution for enhancing the performance of CPT systems.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (1) , 1302-1311
Output Voltage Fluctuation Mitigation of CPT Based on LPV Modeling and Robust Control
This paper investigates a LPV-based output voltage mitigation method for the capacitive wireless power transfer (CPT) system employing a series Buck converter under varying mutual capacitance conditions. A linear parameter varying (LPV) model is utilized to represent the dynamics of the Buck converter under input voltage fluctuations. Based on the estimated model, a robust controller is designed using the normalized coprime factorization (NCF) approach to ensure system stability and performance. Experimental results demonstrate the effectiveness of the proposed method. The system achieves rapid voltage regulation and maintains stable output voltage under various disturbance frequencies and load conditions. These findings validate the robustness and adaptability of the proposed control strategy, offering a reliable solution for enhancing the performance of CPT systems.
- Open Access
- 31 March 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 25 (9) , 1784
Correction: Modeling and flexible power control of electric vehicle wireless charging applied to building side AC/DC power distribution and consumption on building side
- 31 March 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 25 (9) , 1784
Open AccessCorrection: Modeling and flexible power control of electric vehicle wireless charging applied to building side AC/DC power distribution and consumption on building side
- 18 February 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 25 (8) , 1582-1591
Modeling and flexible power control of electric vehicle wireless charging applied to building side AC/DC power distribution and consumption on building side
- 18 February 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 25 (8) , 1582-1591
Modeling and flexible power control of electric vehicle wireless charging applied to building side AC/DC power distribution and consumption on building side
- 30 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 10111-10122
AC-Resistance Evaluation and Reduction Based on Nonuniformity Current Distribution of Large-Strand-Count Litz Wire
Large-strand-count Litz wire (LLW) coils are commonly utilized in high-power wireless power transfer systems. An accurate ac-resistance prediction method of LLW coil is necessary to select the proper operation frequency dedicated for the highest coil quality factor and system efficiency. However, most present literatures ignore the interstrands nonuniform current distribution (NCD) of LLW caused by the soldering tins at terminals, which leads to a high ac-resistance prediction error. This article develops a method extracting the NCD among strands based on the two-dimension finite element analysis and strands probability transposition. And an improved ac-resistance prediction method considering the NCD is proposed subsequently, which is primarily applicable to LLW containing over 500 strands. Moreover, a novel strand edge-soldering connector (SEC) is designed to mitigate NCD and thereby reducing ac-resistance. Finally, the satisfactory accuracy of improved ac-resistance prediction for LLW circular coils up to 1000 strands is verified experimentally. Then, the proposed SEC prototype is measured with a maximum resistance reduction of 33.28%, which demonstrates the effectiveness of the proposed NCD mitigation method.
- 30 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 10111-10122
AC-Resistance Evaluation and Reduction Based on Nonuniformity Current Distribution of Large-Strand-Count Litz Wire
Large-strand-count Litz wire (LLW) coils are commonly utilized in high-power wireless power transfer systems. An accurate ac-resistance prediction method of LLW coil is necessary to select the proper operation frequency dedicated for the highest coil quality factor and system efficiency. However, most present literatures ignore the interstrands nonuniform current distribution (NCD) of LLW caused by the soldering tins at terminals, which leads to a high ac-resistance prediction error. This article develops a method extracting the NCD among strands based on the two-dimension finite element analysis and strands probability transposition. And an improved ac-resistance prediction method considering the NCD is proposed subsequently, which is primarily applicable to LLW containing over 500 strands. Moreover, a novel strand edge-soldering connector (SEC) is designed to mitigate NCD and thereby reducing ac-resistance. Finally, the satisfactory accuracy of improved ac-resistance prediction for LLW circular coils up to 1000 strands is verified experimentally. Then, the proposed SEC prototype is measured with a maximum resistance reduction of 33.28%, which demonstrates the effectiveness of the proposed NCD mitigation method.
- 9 March 2024
- Published by Springer Nature
- p. 560-570
Application Potential Extension of PSDF Buildings Based on Output-Parallel EV Wireless Charging
- 9 March 2024
- Published by Springer Nature
- p. 560-570
Application Potential Extension of PSDF Buildings Based on Output-Parallel EV Wireless Charging
- 9 March 2024
- Published by Springer Nature
- p. 222-234
Adaptive Switching Control for Wireless Power Transfer Systems Based on Identification
- 9 March 2024
- Published by Springer Nature
- p. 222-234
Adaptive Switching Control for Wireless Power Transfer Systems Based on Identification
- 14 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (7) , 8883-8893
Identification and H$\infty$ Robust Control of Wireless Power Transfer System by Hammerstein Model
In the field of control-oriented modeling of wireless power transfer (WPT) system, it is urgent to establish a simple model to reflect the nonlinear characteristics introduced by phase-shift control methods, which is significant to the design of controllers. Due to the nonlinear nature introduced by phase-shift control, controllers designed based on specific steady-state small-signal models struggle to maintain closed-loop dynamic performance. In this article, the nonlinearities of the WPT system are implicitly considered by using the Hammerstein model-based identification (HMI) method, so the accuracy of the identified model is guaranteed even if the working point changes, which is unique advantage compared with other methods. In particular, an uncertainty model is precisely established via a frequency-domain analysis approach to introduce the nonlinear characteristics and the statistical properties of identification into the H $\infty$ control problem, which maintains the robustness of closed-loop WPT system. Finally, an experiment is given to verify the effectiveness of HMI method and proposed H $\infty$ robust controller.
- 14 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (7) , 8883-8893
Identification and H$\infty$ Robust Control of Wireless Power Transfer System by Hammerstein Model
In the field of control-oriented modeling of wireless power transfer (WPT) system, it is urgent to establish a simple model to reflect the nonlinear characteristics introduced by phase-shift control methods, which is significant to the design of controllers. Due to the nonlinear nature introduced by phase-shift control, controllers designed based on specific steady-state small-signal models struggle to maintain closed-loop dynamic performance. In this article, the nonlinearities of the WPT system are implicitly considered by using the Hammerstein model-based identification (HMI) method, so the accuracy of the identified model is guaranteed even if the working point changes, which is unique advantage compared with other methods. In particular, an uncertainty model is precisely established via a frequency-domain analysis approach to introduce the nonlinear characteristics and the statistical properties of identification into the H $\infty$ control problem, which maintains the robustness of closed-loop WPT system. Finally, an experiment is given to verify the effectiveness of HMI method and proposed H $\infty$ robust controller.
- 11 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (2) , 3690-3700
Pulse Interference Suppression for Wireless Shore Power System Considering Energy Supplying Priority
The interference caused by sudden load change in the wireless shore power system (WSPS) weakens the stability of the system. Thus, a pulse interference suppression strategy is proposed, which adopts a power allocation method based on work mode recognition algorithm (WMRA). The method realizes that the pulse load power is preferentially provided by the wireless power transfer system (WPTS), making full use of the shore power. If the WPTS cannot meet the total power demand, the insufficient part is provided by the hybrid energy storage system (HESS). For the HESS at the ship-side, an improved virtual impedance parameter design method is proposed to achieve power reallocation between the lithium battery and the supercapacitor. The high-energy-density of lithium batteries and the high-power-density of supercapacitors can be fully utilized by this method. A prototype is built to verify the proposed strategy. Experiments show that the DC load voltage on the ship-side can be quickly stabilized after being disturbed by a pulse load.
- 11 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (2) , 3690-3700
Pulse Interference Suppression for Wireless Shore Power System Considering Energy Supplying Priority
The interference caused by sudden load change in the wireless shore power system (WSPS) weakens the stability of the system. Thus, a pulse interference suppression strategy is proposed, which adopts a power allocation method based on work mode recognition algorithm (WMRA). The method realizes that the pulse load power is preferentially provided by the wireless power transfer system (WPTS), making full use of the shore power. If the WPTS cannot meet the total power demand, the insufficient part is provided by the hybrid energy storage system (HESS). For the HESS at the ship-side, an improved virtual impedance parameter design method is proposed to achieve power reallocation between the lithium battery and the supercapacitor. The high-energy-density of lithium batteries and the high-power-density of supercapacitors can be fully utilized by this method. A prototype is built to verify the proposed strategy. Experiments show that the DC load voltage on the ship-side can be quickly stabilized after being disturbed by a pulse load.