Aleksandr Bancer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aleksandr Bancer has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Marcin Pietrzak
The Henryk Niewodniczanski Institute of Nuclear Physics PAS
11 shared publications - Antoni Rucinski
Institute of Nuclear Physics PAS, Radzikowskiego 152, Krakow, 31-342, POLAND
4 shared publications - Beata Brzozowska
University of Warsaw
4 shared publications - Jaroslaw Grzyb
National Centre for Nuclear Research, 05-400 Otwock, Poland
3 shared publications - Marcin Bielewicz
National Centre for Nuclear Research, 05-400 Otwock, Poland
3 shared publications - Ana Belchior
Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Campus Tecnológico e Nuclear, Estrada Nacional 10, Km 139.7, 2695-066 Bobadela LRS, Portugal
2 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Elsevier in SSRN Electronic Journal
Toward Ionization Cluster Size Measurements with a Compact Nanodosimeter
Nanodosimetry aims to provide measurable quantities related to the nanoscopic particle track structure, which determines the biological effectiveness of radiation. While simulated nanodosimetry has already demonstrated its potential for radiation treatment planning, the experimental realization of practical nanodosimetric detectors is still in its early stages.In this work, a nanodosimetric prototype operated with low-pressure gas was developed to count ionizations in a nanometer-equivalent sensitive gas volume. Its performance was evaluated experimentally with alpha beams from an 241Am source in 1 mbar propane gas. The results support the further development of this compact nanodosimeter class, with potential applications in particle therapy, radiation protection, and space radiation dosimetry.
- 1 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessToward Ionization Cluster Size Measurements with a Compact Nanodosimeter
Nanodosimetry aims to provide measurable quantities related to the nanoscopic particle track structure, which determines the biological effectiveness of radiation. While simulated nanodosimetry has already demonstrated its potential for radiation treatment planning, the experimental realization of practical nanodosimetric detectors is still in its early stages.In this work, a nanodosimetric prototype operated with low-pressure gas was developed to count ionizations in a nanometer-equivalent sensitive gas volume. Its performance was evaluated experimentally with alpha beams from an 241Am source in 1 mbar propane gas. The results support the further development of this compact nanodosimeter class, with potential applications in particle therapy, radiation protection, and space radiation dosimetry.
- Open Access
Studies of the Modular COsmic Ray Detector (MCORD) Using an Automatic Temperature Control Loop to Maintain Constant Gain Parameters of Semiconductor SiPM Photomultipliers
The Modular Cosmic Ray Detector (MCORD) is a modular scintillator-based system employing silicon photomultipliers (SiPMs) and FPGA-based digital signal processing, designed for applications such as cosmic muon detection, veto systems, and detector calibration support. In this work, we investigate the influence of ambient temperature variations on detector performance, with particular emphasis on SiPM gain stability. Several automatic temperature compensation loops were implemented to stabilize the operating voltage of the sensors. Based on controlled laboratory measurements, we evaluate the effectiveness of different control strategies, including variations in temperature averaging time and threshold response criteria. The performance of each approach is compared in terms of gain stability and response dynamics. We identify the optimal temperature control configuration for planned MCORD measurements and present recent modifications to the detector electronics, including updated software for Analog Front End (AFE) control. Additionally, we describe modifications made to the detector’s electronics since the previous publication, including new software developed to control AFE electronics.
Open AccessStudies of the Modular COsmic Ray Detector (MCORD) Using an Automatic Temperature Control Loop to Maintain Constant Gain Parameters of Semiconductor SiPM Photomultipliers
The Modular Cosmic Ray Detector (MCORD) is a modular scintillator-based system employing silicon photomultipliers (SiPMs) and FPGA-based digital signal processing, designed for applications such as cosmic muon detection, veto systems, and detector calibration support. In this work, we investigate the influence of ambient temperature variations on detector performance, with particular emphasis on SiPM gain stability. Several automatic temperature compensation loops were implemented to stabilize the operating voltage of the sensors. Based on controlled laboratory measurements, we evaluate the effectiveness of different control strategies, including variations in temperature averaging time and threshold response criteria. The performance of each approach is compared in terms of gain stability and response dynamics. We identify the optimal temperature control configuration for planned MCORD measurements and present recent modifications to the detector electronics, including updated software for Analog Front End (AFE) control. Additionally, we describe modifications made to the detector’s electronics since the previous publication, including new software developed to control AFE electronics.
- Open Access
- 9 February 2026
- Published by Springer Nature in EPJ Techniques and Instrumentation
- Vol. 13 (1) , 2
Study of ion detection efficiency in Jet Counter nanodosimeter
This work reevaluates the ion detection efficiency of the Jet Counter nanodosimeter working with low-pressure nitrogen. SIMION simulations were used to model the trajectories of ions during their extraction from the interaction chamber. The study examined the relationship between efficiency vs. extraction voltage, gas density, and temperature. The highest detection efficiency (approximately 60%) was achieved at a high extraction voltage and low temperature. The findings were then used as a parameter in the Monte Carlo modeling of the Jet Counter operations, and the results were compared with experimental results, showing satisfactory agreement.
- 9 February 2026
- Published by Springer Nature in EPJ Techniques and Instrumentation
- Vol. 13 (1) , 2
Open AccessStudy of ion detection efficiency in Jet Counter nanodosimeter
This work reevaluates the ion detection efficiency of the Jet Counter nanodosimeter working with low-pressure nitrogen. SIMION simulations were used to model the trajectories of ions during their extraction from the interaction chamber. The study examined the relationship between efficiency vs. extraction voltage, gas density, and temperature. The highest detection efficiency (approximately 60%) was achieved at a high extraction voltage and low temperature. The findings were then used as a parameter in the Monte Carlo modeling of the Jet Counter operations, and the results were compared with experimental results, showing satisfactory agreement.
- Open Access
- 15 October 2025
- Published by Springer Nature in Research Square
Study of ion detection efficiency in Jet Counter nanodosimeter
This work reevaluates the ion detection efficiency of the Jet Counter nanodosimeter working with low-pressure nitrogen. SIMION simulations were used to model the trajectories of ions during their extraction from the interaction chamber. The study examined the relationship between efficiency vs. extraction voltage, gas density, and temperature. The highest detection efficiency (approximately 60%) was achieved at a high extraction voltage and low temperature. The findings were then used as a parameter in the Monte Carlo modeling of the Jet Counter operations, and the results were compared with experimental results, showing satisfactory agreement.
- 15 October 2025
- Published by Springer Nature in Research Square
Open AccessStudy of ion detection efficiency in Jet Counter nanodosimeter
This work reevaluates the ion detection efficiency of the Jet Counter nanodosimeter working with low-pressure nitrogen. SIMION simulations were used to model the trajectories of ions during their extraction from the interaction chamber. The study examined the relationship between efficiency vs. extraction voltage, gas density, and temperature. The highest detection efficiency (approximately 60%) was achieved at a high extraction voltage and low temperature. The findings were then used as a parameter in the Monte Carlo modeling of the Jet Counter operations, and the results were compared with experimental results, showing satisfactory agreement.
- 2 May 2025
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 162 (17)
Low energy electron induced fragmentation of hot asparagine and aspartic acid molecules
Asparagine (Asn) and aspartic acid (Asp) are not only amino acids found in proteins but also building blocks for synthesis of eco-friendly polymers with techniques such those in which electrons play a role. In this contribution, we present a comparative study of dissociative electron attachment (DEA) to Asn and Asp under gas-phase conditions by means of DEA spectroscopy. In contrast to a number of amino acids studied so far, the formation of the dehydrogenated parent anion, (M – H)−, at about 1.2 eV from both investigated compounds is not the most intense dissociation channel. On the other hand, prominent negative ion resonances are observed peaking below 0.5 eV, resulting in the formation of fragment anions generated from a loss of a neutral –COOH group or neutral H2O2 molecule or leading to the production of HCOO− from both asparagine and aspartic acid. It should be stressed here that the surrogation of one hydroxyl group by an amino group in aspartic acid, which results in the formation of asparagine, sensitizes the latter compound for the loss of an entire neutral carboxyl group. Indeed, the formation of the (Asn – COOH)− anion from DEA to asparagine is more efficient by about an order of magnitude than the formation of the (Asp – COOH)− anion from DEA to aspartic acid.
- 2 May 2025
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 162 (17)
Low energy electron induced fragmentation of hot asparagine and aspartic acid molecules
Asparagine (Asn) and aspartic acid (Asp) are not only amino acids found in proteins but also building blocks for synthesis of eco-friendly polymers with techniques such those in which electrons play a role. In this contribution, we present a comparative study of dissociative electron attachment (DEA) to Asn and Asp under gas-phase conditions by means of DEA spectroscopy. In contrast to a number of amino acids studied so far, the formation of the dehydrogenated parent anion, (M – H)−, at about 1.2 eV from both investigated compounds is not the most intense dissociation channel. On the other hand, prominent negative ion resonances are observed peaking below 0.5 eV, resulting in the formation of fragment anions generated from a loss of a neutral –COOH group or neutral H2O2 molecule or leading to the production of HCOO− from both asparagine and aspartic acid. It should be stressed here that the surrogation of one hydroxyl group by an amino group in aspartic acid, which results in the formation of asparagine, sensitizes the latter compound for the loss of an entire neutral carboxyl group. Indeed, the formation of the (Asn – COOH)− anion from DEA to asparagine is more efficient by about an order of magnitude than the formation of the (Asp – COOH)− anion from DEA to aspartic acid.
- Open Access
- 7 May 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (10) , 5094
Ionization Detail Parameters for DNA Damage Evaluation in Charged Particle Radiotherapy: Simulation Study Based on Cell Survival Database
Details of excitation and ionization acts hide a description of the biological effects of charged particle traversal through living tissue. Nanodosimetry enables the introduction of novel quantities that characterize and quantify the particle track structure while also serving as a foundation for assessing biological effects based on this quantification. This presents an opportunity to enhance the planning of charged particle radiotherapy by taking into account the ionization detail. This work uses Monte Carlo simulations with Geant4-DNA code for a wide variety of charged particles and their radiation qualities to analyze the distribution of ionization cluster sizes within nanometer-scale volumes, similar to DNA diameter. By correlating these results with biological parameters extracted from the PIDE database for the V79 cell line, a novel parameter based on ionization details is proposed for the evaluation of radiation quality in terms of biological consequences, i.e., radiobiological cross section for inactivation. By incorporating the probability p of sub-lethal damage caused by a single ionization, we address limitations associated with the usually proposed nanodosimetric parameter for characterizing the biological effects of radiation. We show that the new parameter correlates well with radiobiological data and can be used to predict biological outcomes.- 7 May 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (10) , 5094
Open AccessIonization Detail Parameters for DNA Damage Evaluation in Charged Particle Radiotherapy: Simulation Study Based on Cell Survival Database
Details of excitation and ionization acts hide a description of the biological effects of charged particle traversal through living tissue. Nanodosimetry enables the introduction of novel quantities that characterize and quantify the particle track structure while also serving as a foundation for assessing biological effects based on this quantification. This presents an opportunity to enhance the planning of charged particle radiotherapy by taking into account the ionization detail. This work uses Monte Carlo simulations with Geant4-DNA code for a wide variety of charged particles and their radiation qualities to analyze the distribution of ionization cluster sizes within nanometer-scale volumes, similar to DNA diameter. By correlating these results with biological parameters extracted from the PIDE database for the V79 cell line, a novel parameter based on ionization details is proposed for the evaluation of radiation quality in terms of biological consequences, i.e., radiobiological cross section for inactivation. By incorporating the probability p of sub-lethal damage caused by a single ionization, we address limitations associated with the usually proposed nanodosimetric parameter for characterizing the biological effects of radiation. We show that the new parameter correlates well with radiobiological data and can be used to predict biological outcomes. - Open Access
- 22 March 2023
- Published by MDPI AG in Electronics
- Vol. 12 (6) , 1492
Practical Implementation of an Analogue and Digital Electronics System for a Modular Cosmic Ray Detector—MCORD
A Modular COsmic Ray Detector (MCORD) was prepared for use in various physics experiments. MCORD detectors can be used in laboratory measurements or can become a part of large measurement sets. MCORD can be used as a muon detector, a veto system, or a tool supporting the testing and calibration of other detectors. MCORD can also work as a stand-alone device for scientific and commercial purposes. The basic element of MCORD is one section consisting of eight oblong scintillators with a double-sided light reading performed by silicon photomultipliers (SiPMs). This work presents a practical description of testing, calibration, and programming of analogue and digital electronics modules. The characterisation and calibration methods of the analogue front-end electronic modules, the obtained results, and their implementation into an operating system are presented. In addition, we describe the development environment and the procedures used to prepare our kit for practical use. The architecture of the FPGAs is also presented with a description of their programming as a data-collecting system in a simple coincidence circuit. We also present the possibilities of extending the data analysis system for large experiments.
- 22 March 2023
- Published by MDPI AG in Electronics
- Vol. 12 (6) , 1492
Open AccessPractical Implementation of an Analogue and Digital Electronics System for a Modular Cosmic Ray Detector—MCORD
A Modular COsmic Ray Detector (MCORD) was prepared for use in various physics experiments. MCORD detectors can be used in laboratory measurements or can become a part of large measurement sets. MCORD can be used as a muon detector, a veto system, or a tool supporting the testing and calibration of other detectors. MCORD can also work as a stand-alone device for scientific and commercial purposes. The basic element of MCORD is one section consisting of eight oblong scintillators with a double-sided light reading performed by silicon photomultipliers (SiPMs). This work presents a practical description of testing, calibration, and programming of analogue and digital electronics modules. The characterisation and calibration methods of the analogue front-end electronic modules, the obtained results, and their implementation into an operating system are presented. In addition, we describe the development environment and the procedures used to prepare our kit for practical use. The architecture of the FPGAs is also presented with a description of their programming as a data-collecting system in a simple coincidence circuit. We also present the possibilities of extending the data analysis system for large experiments.
- 23 September 2022
- Published by Elsevier in Physica Medica
- Vol. 102, 103-109
Intercomparison of nanodosimetric distributions in nitrogen simulated with Geant4 and PTra track structure codes
- 23 September 2022
- Published by Elsevier in Physica Medica
- Vol. 102, 103-109
Intercomparison of nanodosimetric distributions in nitrogen simulated with Geant4 and PTra track structure codes
- Open Access
- 11 November 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (22) , 225008
Geant4-DNA modeling of nanodosimetric quantities in the Jet Counter for alpha particles
The purpose of this work was to validate the calculation accuracy of nanodosimetric quantities in Geant4-DNA track structure simulation code. We implemented the Jet Counter (JC) nanodosimeter geometry in the simulation platform and quantified the impact of the Geant4-DNA physics models and JC detector performance on the ionization cluster size distributions (ICSD). ICSD parameters characterize the quality of radiation field and are supposed to be correlated to the complexity of the initial DNA damage in nanoscale and eventually the response of biological systems to radiation. We compared Monte Carlo simulations of ICSD in JC geometry performed using Geant4-DNA and PTra codes with experimental data collected for alpha particles at 3.8 MeV. We investigated the impact of simulation and experimental settings, i.e., three Geant4-DNA physics models, three sizes of a nanometer sensitive volume, gas to water density scaling procedure, JC ion extraction efficiency and the presence of passive components of the detector on the ICSD and their parameters. We found that ICSD in JC geometry obtained from Geant4-DNA simulations in water correspond well to ICSD measurements in nitrogen gas for all investigated settings, while the best agreement is for Geant4-DNA physics option 4. This work also discusses the accuracy and robustness of ICSD parameters in the context of the application of track structure simulation methods for treatment planning in particle therapy.
- 11 November 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (22) , 225008
Open AccessGeant4-DNA modeling of nanodosimetric quantities in the Jet Counter for alpha particles
The purpose of this work was to validate the calculation accuracy of nanodosimetric quantities in Geant4-DNA track structure simulation code. We implemented the Jet Counter (JC) nanodosimeter geometry in the simulation platform and quantified the impact of the Geant4-DNA physics models and JC detector performance on the ionization cluster size distributions (ICSD). ICSD parameters characterize the quality of radiation field and are supposed to be correlated to the complexity of the initial DNA damage in nanoscale and eventually the response of biological systems to radiation. We compared Monte Carlo simulations of ICSD in JC geometry performed using Geant4-DNA and PTra codes with experimental data collected for alpha particles at 3.8 MeV. We investigated the impact of simulation and experimental settings, i.e., three Geant4-DNA physics models, three sizes of a nanometer sensitive volume, gas to water density scaling procedure, JC ion extraction efficiency and the presence of passive components of the detector on the ICSD and their parameters. We found that ICSD in JC geometry obtained from Geant4-DNA simulations in water correspond well to ICSD measurements in nitrogen gas for all investigated settings, while the best agreement is for Geant4-DNA physics option 4. This work also discusses the accuracy and robustness of ICSD parameters in the context of the application of track structure simulation methods for treatment planning in particle therapy.