Rafael Cury Cecato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rafael Cury Cecato has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
J. Silva
Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Brazil
2 shared publicationsR.C. Cecato
Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Brazil
2 shared publications- A.C. Lorenz-Vieira
Center for Education and Research on Dental Implants (CEPID), Post-Graduate Program in Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
1 shared publication - Adriana Terezinha Neves Novellino Alves
Oral Diagnosis Department, Fluminense Federal University (UFF), Niteroi 24220-140, RJ, Brazil
1 shared publication - Ana Carla Gonçales de Souza
Mestranda, Programa de Pós-Graduação em Ciência Odontológica, Universidade Estadual Paulista (Unesp), Faculdade de Odontologia de Araçatuba, 16015-050 Araçatuba - SP, Brasil
1 shared publication C.A.M. Benfatti
1 shared publication
Latest Publications
- Open Access
Synthesis and Evaluation of Porous Nanosynt Block (FGM®) as Synthetic Bone Substitute for Bone Tissue Engineering
Synthetic bone substitutes based on hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP) are widely used in regenerative dentistry due to their favorable biocompatibility and osteoconductive properties. This study aimed to evaluate, through laboratory-based analyses, the porosity and surface characteristics of the Nanosynt Block (FGM Dental Group®) for bone regeneration applications. The Nanosynt Block, consisting of 60% HA and 40% β-TCP, was analyzed using scanning electron microscopy (SEM) for surface morphology characterization, micro-computed tomography (Micro-CT) for internal structure evaluation, and mercury intrusion porosimetry for porosity assessment. SEM imaging followed the ASTM E1829-02 standard, while Micro-CT and porosimetry provided detailed quantitative data. SEM analysis revealed a homogeneous pore distribution on the surface. Micro-CT indicated high structural stability and consistent volumetric porosity, ranging from 73.27% to 77.08%. Porosimetry indicated a total porosity of 94.9%, with a median pore diameter of 799 nm, characteristics suitable for promoting cellular adhesion and fluid infiltration. The structural and morphological properties of the Nanosynt Block highlight its potential to support initial bone formation and mechanical stability in clinical applications. These findings provide a robust basis for subsequent in vivo investigations to validate its clinical efficacy.
Open AccessSynthesis and Evaluation of Porous Nanosynt Block (FGM®) as Synthetic Bone Substitute for Bone Tissue Engineering
Synthetic bone substitutes based on hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP) are widely used in regenerative dentistry due to their favorable biocompatibility and osteoconductive properties. This study aimed to evaluate, through laboratory-based analyses, the porosity and surface characteristics of the Nanosynt Block (FGM Dental Group®) for bone regeneration applications. The Nanosynt Block, consisting of 60% HA and 40% β-TCP, was analyzed using scanning electron microscopy (SEM) for surface morphology characterization, micro-computed tomography (Micro-CT) for internal structure evaluation, and mercury intrusion porosimetry for porosity assessment. SEM imaging followed the ASTM E1829-02 standard, while Micro-CT and porosimetry provided detailed quantitative data. SEM analysis revealed a homogeneous pore distribution on the surface. Micro-CT indicated high structural stability and consistent volumetric porosity, ranging from 73.27% to 77.08%. Porosimetry indicated a total porosity of 94.9%, with a median pore diameter of 799 nm, characteristics suitable for promoting cellular adhesion and fluid infiltration. The structural and morphological properties of the Nanosynt Block highlight its potential to support initial bone formation and mechanical stability in clinical applications. These findings provide a robust basis for subsequent in vivo investigations to validate its clinical efficacy.
- Open Access
In Vivo Evaluation of Permeable and Impermeable Membranes for Guided Bone Regeneration
Background: The degree of biodegradation and the inflammatory response of membranes employed for guided bone regeneration directly impact the outcome of this technique. This study aimed to evaluate four different experimental versions of Poly (L-lactate-co-Trimethylene Carbonate) (PTMC) + Poly (L-lactate-co-glycolate) (PLGA) membranes, implanted in mouse subcutaneous tissue, compared to a commercially available membrane and a Sham group. Methods: Sixty Balb-C mice were randomly divided into six experimental groups and subdivided into 1, 3, 6 and 12 weeks (n = 5 groups/period). The membranes (1 cm2) were implanted in the subcutaneous back tissue of the animals. The samples were obtained for descriptive and semiquantitative histological evaluation (ISO 10993-6). Results: G1 and G4 allowed tissue adhesion and the permeation of inflammatory cells over time and showed greater phagocytic activity and permeability. G2 and G3 detached from the tissue in one and three weeks; however, in the more extended periods, they presented a rectilinear and homogeneous aspect and were not absorbed. G2 had a major inflammatory reaction. G5 was almost completely absorbed after 12 weeks. Conclusions: The membranes are considered biocompatible. G5 showed a higher degree of biosorption, followed by G1 and G4. G2 and G3 are considered non-absorbable in the studied periods.
Open AccessIn Vivo Evaluation of Permeable and Impermeable Membranes for Guided Bone Regeneration
Background: The degree of biodegradation and the inflammatory response of membranes employed for guided bone regeneration directly impact the outcome of this technique. This study aimed to evaluate four different experimental versions of Poly (L-lactate-co-Trimethylene Carbonate) (PTMC) + Poly (L-lactate-co-glycolate) (PLGA) membranes, implanted in mouse subcutaneous tissue, compared to a commercially available membrane and a Sham group. Methods: Sixty Balb-C mice were randomly divided into six experimental groups and subdivided into 1, 3, 6 and 12 weeks (n = 5 groups/period). The membranes (1 cm2) were implanted in the subcutaneous back tissue of the animals. The samples were obtained for descriptive and semiquantitative histological evaluation (ISO 10993-6). Results: G1 and G4 allowed tissue adhesion and the permeation of inflammatory cells over time and showed greater phagocytic activity and permeability. G2 and G3 detached from the tissue in one and three weeks; however, in the more extended periods, they presented a rectilinear and homogeneous aspect and were not absorbed. G2 had a major inflammatory reaction. G5 was almost completely absorbed after 12 weeks. Conclusions: The membranes are considered biocompatible. G5 showed a higher degree of biosorption, followed by G1 and G4. G2 and G3 are considered non-absorbable in the studied periods.
- 21 May 2022
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 23 (1) , 22-30
Analysis of the Viability and Morphology of Gingival Cells on Materials Used in Novel Prosthetic Components: In Vitro Study
The objective of this in vitro study was to evaluate the viability and morphology of human fibroblasts and keratinocytes cells, both grown on stainless steel (steel) (18Cr14Ni2.5Mo), and polyether-ether-ketone (PEEK) surfaces, hypothesizing the use of these surfaces as novel materials for prosthetic components. Gingival human keratinocytes and gingival human fibroblasts lines were grown on discs made by steel (n = 36), PEEK (n = 36), and titanium (Ti) (Ti6A14V) (n = 36)-control. For viability assay, cultures were grown at 24 hours (TV1), 48 hours (TV2), and 72 hours (TV3) times and evaluated by the colorimetric tetrazolium assay (MTT). For morphology and cell adhesion assays, after 24 hours (TM1), 48 hours (TM2), and 96 hours (TM3) of cell culture, cells were examined by scanning electron microscopy (SEM) and analyzed at magnifications with 500×, 1,000×, and 2,500×. Regarding the viability, the keratinocytes did not present statistical difference on the different materials, in TV1 and TV3 times of culture. Their growth rate increased on all materials, being more expressive in steel; the fibroblasts did not present statistical difference on the different materials, in TV2 and TV3 times of culture. The growth rate of these decreased on all materials, being more expressive in PEEK. The morphology analyses show increase in cell numbers, adequate spreading, and adhesion at all cultivation times (TM1, TM2, and TM3) in both cell lines, on all materials. All materials tested are suitable for use in the manufacture of prosthetic components for implant-supported rehabilitations, considering the limitations of this study. This work analyzes the cellular response of cells present in the human gingiva, as a way to simulate the peri-implant tissue response around novel angular prosthetic components made of stainless steel and PEEK.
- 21 May 2022
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 23 (1) , 22-30
Analysis of the Viability and Morphology of Gingival Cells on Materials Used in Novel Prosthetic Components: In Vitro Study
The objective of this in vitro study was to evaluate the viability and morphology of human fibroblasts and keratinocytes cells, both grown on stainless steel (steel) (18Cr14Ni2.5Mo), and polyether-ether-ketone (PEEK) surfaces, hypothesizing the use of these surfaces as novel materials for prosthetic components. Gingival human keratinocytes and gingival human fibroblasts lines were grown on discs made by steel (n = 36), PEEK (n = 36), and titanium (Ti) (Ti6A14V) (n = 36)-control. For viability assay, cultures were grown at 24 hours (TV1), 48 hours (TV2), and 72 hours (TV3) times and evaluated by the colorimetric tetrazolium assay (MTT). For morphology and cell adhesion assays, after 24 hours (TM1), 48 hours (TM2), and 96 hours (TM3) of cell culture, cells were examined by scanning electron microscopy (SEM) and analyzed at magnifications with 500×, 1,000×, and 2,500×. Regarding the viability, the keratinocytes did not present statistical difference on the different materials, in TV1 and TV3 times of culture. Their growth rate increased on all materials, being more expressive in steel; the fibroblasts did not present statistical difference on the different materials, in TV2 and TV3 times of culture. The growth rate of these decreased on all materials, being more expressive in PEEK. The morphology analyses show increase in cell numbers, adequate spreading, and adhesion at all cultivation times (TM1, TM2, and TM3) in both cell lines, on all materials. All materials tested are suitable for use in the manufacture of prosthetic components for implant-supported rehabilitations, considering the limitations of this study. This work analyzes the cellular response of cells present in the human gingiva, as a way to simulate the peri-implant tissue response around novel angular prosthetic components made of stainless steel and PEEK.
- Open Access
- 11 October 2021
- Published by Elsevier in Advances in Oral and Maxillofacial Surgery
- Vol. 4, 100195
Brief presentation of a mandibular overdenture over bendable abutments – A technical note
- 11 October 2021
- Published by Elsevier in Advances in Oral and Maxillofacial Surgery
- Vol. 4, 100195
Open AccessBrief presentation of a mandibular overdenture over bendable abutments – A technical note
- 1 January 2018
- Published by Elsevier in Dental Materials
- Vol. 34, e82
Clinical performance of 168 screw free implants: Prosthetic complications
- 1 January 2018
- Published by Elsevier in Dental Materials
- Vol. 34, e82
Clinical performance of 168 screw free implants: Prosthetic complications
- 1 January 2018
- Published by Elsevier in Dental Materials
- Vol. 34, e108
Color stability of repairs on bis-acrylic resin after colorants immersion
- 1 January 2018
- Published by Elsevier in Dental Materials
- Vol. 34, e108
Color stability of repairs on bis-acrylic resin after colorants immersion