CZCong Zhou
Cong Zhou
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cong Zhou has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Lifeng Li
7 shared publicationsJianqun Wang
3 shared publications- Doo-Yeol Yoo
Department of Architecture and Architectural Engineering, Yonsei University, Seoul, Republic of Korea
2 shared publications - Jiahao Mao
The University of Osaka Department of Civil Engineering
2 shared publications Jiahao Tang
2 shared publications- Jianqun Wang
Hunan Provincial Key Laboratory of Structures for Wind Resistance and Vibration Control, School of Civil Engineering, Hunan University of science and technology, Xiangtan 411201, China
2 shared publications
Latest Publications
- 16 July 2025
- Published by Elsevier in Engineering Structures
- Vol. 342
Experimental investigation and numerical study on the seismic behavior of precast concrete piers with UHPC connection
- 16 July 2025
- Published by Elsevier in Engineering Structures
- Vol. 342
Experimental investigation and numerical study on the seismic behavior of precast concrete piers with UHPC connection
- 10 June 2025
- Published by Elsevier in Structures
- Vol. 78
Full-scale experimental study on shear performance of UHPC sandwich panels with UHPC-filled stainless steel pipe shear connectors
- 10 June 2025
- Published by Elsevier in Structures
- Vol. 78
Full-scale experimental study on shear performance of UHPC sandwich panels with UHPC-filled stainless steel pipe shear connectors
- 14 February 2025
- Published by Elsevier in Composite Structures
- Vol. 357
Enhancing torsional behavior of RC beams: The potential of ultra-high performance concrete (UHPC)
- 14 February 2025
- Published by Elsevier in Composite Structures
- Vol. 357
Enhancing torsional behavior of RC beams: The potential of ultra-high performance concrete (UHPC)
- Top Cited Papers
- 14 October 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 408
Prediction of shear strength in UHPC beams using machine learning-based models and SHAP interpretation
- 14 October 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 408
Top Cited PapersPrediction of shear strength in UHPC beams using machine learning-based models and SHAP interpretation
- 1 October 2020
- Published by Elsevier in Thin-Walled Structures
- Vol. 155
Modified bar simulation method for shear lag analysis of non-prismatic composite box girders with corrugated steel webs
- 1 October 2020
- Published by Elsevier in Thin-Walled Structures
- Vol. 155
Modified bar simulation method for shear lag analysis of non-prismatic composite box girders with corrugated steel webs
- Open Access
- 28 April 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3076
Flexural Behavior of a 30-Meter Full-Scale Simply Supported Prestressed Concrete Box Girder
Compared with scaled-model testing, full-scale destructive testing is more reliable since the test has no size effect and can truly record the mechanical performance of the structure. However, due to the high cost, only very few full-scale destructive tests have been conducted on the flexural behavior of prestressed concrete (PC) box girders with girders removed from decommissioned bridges. Moreover, related destructive testing on the flexural behavior of a new precast box girder has been rarely reported. To investigate the flexural behavior and optimize the design, destructive testing of a 30-meter full-scale simply supported prestressed box girder was conducted at the construction site. It is illustrated that the failure mode of the tested girder was fracture of the prestressing tendon, and the corresponding maximum compressive strain in the top flange was only 1456 , which is far less than the ultimate compressive strain (3300 ). Therefore, the concrete in the top flange was not fully utilized. A nonlinear analysis procedure was performed using the finite strip method (FSM). The validity of the analysis was demonstrated by comparing the analytical results with those of the full-scale test in the field and a scaled model test in a laboratory. Using the developed numerical method, parametric analyses of the ratio of reinforcement were carried out. The prestressing tendon of the tested girder was increased from four strands to six strands in each duct. After the optimization of the prestressed reinforcement, the girder was ductile and the bearing capacity could be increased by 44.3%.- 28 April 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3076
Open AccessFlexural Behavior of a 30-Meter Full-Scale Simply Supported Prestressed Concrete Box Girder
Compared with scaled-model testing, full-scale destructive testing is more reliable since the test has no size effect and can truly record the mechanical performance of the structure. However, due to the high cost, only very few full-scale destructive tests have been conducted on the flexural behavior of prestressed concrete (PC) box girders with girders removed from decommissioned bridges. Moreover, related destructive testing on the flexural behavior of a new precast box girder has been rarely reported. To investigate the flexural behavior and optimize the design, destructive testing of a 30-meter full-scale simply supported prestressed box girder was conducted at the construction site. It is illustrated that the failure mode of the tested girder was fracture of the prestressing tendon, and the corresponding maximum compressive strain in the top flange was only 1456 , which is far less than the ultimate compressive strain (3300 ). Therefore, the concrete in the top flange was not fully utilized. A nonlinear analysis procedure was performed using the finite strip method (FSM). The validity of the analysis was demonstrated by comparing the analytical results with those of the full-scale test in the field and a scaled model test in a laboratory. Using the developed numerical method, parametric analyses of the ratio of reinforcement were carried out. The prestressing tendon of the tested girder was increased from four strands to six strands in each duct. After the optimization of the prestressed reinforcement, the girder was ductile and the bearing capacity could be increased by 44.3%. - 1 February 2019
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 153, 372-384
Improved softened membrane model for prestressed composite box girders with corrugated steel webs under pure torsion
- 1 February 2019
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 153, 372-384
Improved softened membrane model for prestressed composite box girders with corrugated steel webs under pure torsion