Tao Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tao Yang has a total of 231 co-authors. Here are the top co-authors by number of shared publications:
Jun Shen
13 shared publications- Jun Shen
Beijing Institute of Technology
7 shared publications Chenyang Zhu
6 shared publicationsJiangtao Wu
Key Laboratory of Thermo-Fluid Science and Engineering of Ministry of Education, Xi’an Jiaotong University, Xi’an, China
6 shared publicationsQingyu Yang
6 shared publications- Wenqiang Zhang
Beijing Institute of Technology
5 shared publications
Latest Publications
- 7 August 2026
- Published by Elsevier in Fluid Phase Equilibria
- Vol. 612
PC-SAFT-based entropy scaling framework for modelling liquid transport properties of polar and associating organic fluids
- 7 August 2026
- Published by Elsevier in Fluid Phase Equilibria
- Vol. 612
PC-SAFT-based entropy scaling framework for modelling liquid transport properties of polar and associating organic fluids
- Open Access
- 5 August 2026
- Published by Elsevier in The Innovation
- Vol. 7 (11)
AI for science: Progress, challenges, and perspectives
- 5 August 2026
- Published by Elsevier in The Innovation
- Vol. 7 (11)
Open AccessAI for science: Progress, challenges, and perspectives
- Open Access
- 17 April 2026
- Published by Elsevier in SSRN Electronic Journal
Impact of Diamond Wafers on the Thermal Spreading and Heat Transfer Performance of Copper Heat Sinks
With the rapid evolution of artificial intelligence and big data, the thermal design power (TDP) of high-performance chips has escalated significantly, pushing conventional thermal management to its physical limits. A primary bottleneck is the large thermal spreading resistance at the interface between high-power-density chips and traditional heat sinks. To address this, this paper investigates the integration of diamond wafers into copper heat sinks within single-phase immersion cooling systems to enhance thermal spreading and overall heat transfer performance. A three-dimensional numerical model was developed to systematically analyze the impact of diamond wafer dimensions on heat sink efficacy. The results indicate that increasing the diamond wafer diameter from 51 mm to 78 mm facilitates more rapid temperature diffusion at the heat sink base; although the radial thermal resistance rose from 0.045 K/W to 0.093 K/W, the axial thermal resistance dropped from 0.00035 K/W to 0.00015 K/W, leading to a reduction in average heat source temperature from 345.47 K to 342.46 K. Notably, the diamond-enhanced sink achieved a maximum temperature drop of 7.72 K compared to a standard copper sink. Furthermore, increasing the thickness from 1 mm to 3 mm significantly optimized heat diffusion within the sink, reducing the heat source temperature further to 334.29 K. By leveraging diamond’s exceptional thermal conductivity to mitigate the spreading bottleneck, the heat dissipation efficiency was improved from 73.80% to 78.67%. These findings provide a robust theoretical foundation for utilizing diamond wafers to solve heat spreading challenges in next-generation high-performance electronic devices.
- 17 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessImpact of Diamond Wafers on the Thermal Spreading and Heat Transfer Performance of Copper Heat Sinks
With the rapid evolution of artificial intelligence and big data, the thermal design power (TDP) of high-performance chips has escalated significantly, pushing conventional thermal management to its physical limits. A primary bottleneck is the large thermal spreading resistance at the interface between high-power-density chips and traditional heat sinks. To address this, this paper investigates the integration of diamond wafers into copper heat sinks within single-phase immersion cooling systems to enhance thermal spreading and overall heat transfer performance. A three-dimensional numerical model was developed to systematically analyze the impact of diamond wafer dimensions on heat sink efficacy. The results indicate that increasing the diamond wafer diameter from 51 mm to 78 mm facilitates more rapid temperature diffusion at the heat sink base; although the radial thermal resistance rose from 0.045 K/W to 0.093 K/W, the axial thermal resistance dropped from 0.00035 K/W to 0.00015 K/W, leading to a reduction in average heat source temperature from 345.47 K to 342.46 K. Notably, the diamond-enhanced sink achieved a maximum temperature drop of 7.72 K compared to a standard copper sink. Furthermore, increasing the thickness from 1 mm to 3 mm significantly optimized heat diffusion within the sink, reducing the heat source temperature further to 334.29 K. By leveraging diamond’s exceptional thermal conductivity to mitigate the spreading bottleneck, the heat dissipation efficiency was improved from 73.80% to 78.67%. These findings provide a robust theoretical foundation for utilizing diamond wafers to solve heat spreading challenges in next-generation high-performance electronic devices.
- Open Access
Numerical Simulation and Experimental Research of the Hot-Wire Method for Thermal Insulation Materials
The thermal conductivity of thermal insulation materials is a critical parameter for assessing energy efficiency and performance in building, industrial, and aerospace applications. This study combined numerical simulation, parameter inversion optimization and experimental measurement to evaluate the transient hot-wire method for measuring the thermal conductivity of expanded polystyrene (EPS) foam. Using a nickel wire as the hot wire, the effects of various parameters—including wire length and width, heating power, Kapton film thickness and end effect—were systematically analyzed through finite element analysis and Bayesian optimization algorithm. Following the simulation and inversion conclusions, a series of hot-wire sensors with a fixed length of 30 mm and widths of 25 μm, 50 μm, 100 μm, 150 μm, and 200 μm were fabricated for experimental validation. Measurement results were compared against a reference value obtained by the guarded hot plate method. It was found that the sensor with a length of 30 mm and a width of 100 μm demonstrated optimal performance among the configurations tested, with deviations between the experimental measurements and the reference value remaining within approximately ±1.5%.
Open AccessNumerical Simulation and Experimental Research of the Hot-Wire Method for Thermal Insulation Materials
The thermal conductivity of thermal insulation materials is a critical parameter for assessing energy efficiency and performance in building, industrial, and aerospace applications. This study combined numerical simulation, parameter inversion optimization and experimental measurement to evaluate the transient hot-wire method for measuring the thermal conductivity of expanded polystyrene (EPS) foam. Using a nickel wire as the hot wire, the effects of various parameters—including wire length and width, heating power, Kapton film thickness and end effect—were systematically analyzed through finite element analysis and Bayesian optimization algorithm. Following the simulation and inversion conclusions, a series of hot-wire sensors with a fixed length of 30 mm and widths of 25 μm, 50 μm, 100 μm, 150 μm, and 200 μm were fabricated for experimental validation. Measurement results were compared against a reference value obtained by the guarded hot plate method. It was found that the sensor with a length of 30 mm and a width of 100 μm demonstrated optimal performance among the configurations tested, with deviations between the experimental measurements and the reference value remaining within approximately ±1.5%.
- Open Access
- 14 March 2026
- Published by Elsevier in SSRN Electronic Journal
Analysis of Secondary-Loop Performance Matching Characteristics and Exergy Destruction of R290 Electric Vehicles Heat Pump Air Conditioning Systems: Experimental Study
The environmentally friendly refrigerant R290 is one of the most important alternative refrigerants for electric vehicles (EVs) air conditioning system in the future due to its high latent heat of vaporization and low Global Warming Potential (GWP), but the flammable and explosive properties of R290 have severely limited its development and application. The application of a Secondary Loop (SL) structure is an effective methodology to enhance the safety of the flammable refrigerant system, reduce the environmental impact, and improve the overall system performance. In this work, a Dual-Circuit Secondary Loop (DCSL) EVs heat pump system based on R290 was designed, and the heating performance of the system was analyzed at different compressor speeds for changes in indoor air velocity, electronic expansion valve (EEV) opening, coolant flow rate, and ambient temperatures, together with the degree of exergy destruction was evaluated at low temperatures. The result shows that the maximum heating capacity of the system reaches about 4,383 W with the COP of 2.1 at an ambient temperature of -20 °C. The heating capacity of the DCSL increases first and then reduces with with the EEV opening and the coolant flow rate, more important, the EEV opening shows a greater effect on heating capacity than coolant flow rate. As a compressor rotational speed of 4,000 rpm, the increase and decrease in heating capacity due to the EEV opening change can reach 66% and 21%, respectively, while coolant flow rates can cause only 3% to 5% heating capacity fluctuations.
- 14 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAnalysis of Secondary-Loop Performance Matching Characteristics and Exergy Destruction of R290 Electric Vehicles Heat Pump Air Conditioning Systems: Experimental Study
The environmentally friendly refrigerant R290 is one of the most important alternative refrigerants for electric vehicles (EVs) air conditioning system in the future due to its high latent heat of vaporization and low Global Warming Potential (GWP), but the flammable and explosive properties of R290 have severely limited its development and application. The application of a Secondary Loop (SL) structure is an effective methodology to enhance the safety of the flammable refrigerant system, reduce the environmental impact, and improve the overall system performance. In this work, a Dual-Circuit Secondary Loop (DCSL) EVs heat pump system based on R290 was designed, and the heating performance of the system was analyzed at different compressor speeds for changes in indoor air velocity, electronic expansion valve (EEV) opening, coolant flow rate, and ambient temperatures, together with the degree of exergy destruction was evaluated at low temperatures. The result shows that the maximum heating capacity of the system reaches about 4,383 W with the COP of 2.1 at an ambient temperature of -20 °C. The heating capacity of the DCSL increases first and then reduces with with the EEV opening and the coolant flow rate, more important, the EEV opening shows a greater effect on heating capacity than coolant flow rate. As a compressor rotational speed of 4,000 rpm, the increase and decrease in heating capacity due to the EEV opening change can reach 66% and 21%, respectively, while coolant flow rates can cause only 3% to 5% heating capacity fluctuations.
- Open Access
- 6 March 2026
- Published by Elsevier in SSRN Electronic Journal
Analysis of Secondary-Loop Performance Matching Characteristics and Exergy Destruction of R290 Electric Vehicles Heat Pump Air Conditioning Systems: Experimental Study
The environmentally friendly refrigerant R290 is one of the most important alternative refrigerants for electric vehicles (EVs) air conditioning system in the future due to its high latent heat of vaporization and low Global Warming Potential (GWP), but the flammable and explosive properties of R290 have severely limited its development and application. The application of a Secondary Loop (SL) structure is an effective methodology to enhance the safety of the flammable refrigerant system, reduce the environmental impact, and improve the overall system performance. In this work, a Dual-Circuit Secondary Loop (DCSL) EVs heat pump system based on R290 was designed, and the heating performance of the system was analyzed at different compressor speeds for changes in indoor air velocity, electronic expansion valve (EEV) opening, coolant flow rate, and ambient temperatures, together with the degree of exergy destruction was evaluated at low temperatures. The result shows that the maximum heating capacity of the system reaches about 4,383 W with the COP of 2.1 at an ambient temperature of -20 °C. The heating capacity of the DCSL increases first and then reduces with with the EEV opening and the coolant flow rate, more important, the EEV opening shows a greater effect on heating capacity than coolant flow rate. As a compressor rotational speed of 4,000 rpm, the increase and decrease in heating capacity due to the EEV opening change can reach 66% and 21%, respectively, while coolant flow rates can cause only 3% to 5% heating capacity fluctuations. Furthermore, the heat transfer efficiency of DCSL decreased with the increasing of coolant flow rates, with a maximum average efficiency drop of 11%. And when the ambient temperature drops to -20°C, the average heat transfer efficiency is only 0.53, which is a 17.5% drop compared to -10°C. Analysis of the exergy destruction reveals that as the ambient temperature decreases to -20°C, the main sources of increase in exergy destruction are the Outdoor Heat Exchanger and the In-vehicle Condenser, with an increase of 5.7% and 10.1%, respectively.
- 6 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAnalysis of Secondary-Loop Performance Matching Characteristics and Exergy Destruction of R290 Electric Vehicles Heat Pump Air Conditioning Systems: Experimental Study
The environmentally friendly refrigerant R290 is one of the most important alternative refrigerants for electric vehicles (EVs) air conditioning system in the future due to its high latent heat of vaporization and low Global Warming Potential (GWP), but the flammable and explosive properties of R290 have severely limited its development and application. The application of a Secondary Loop (SL) structure is an effective methodology to enhance the safety of the flammable refrigerant system, reduce the environmental impact, and improve the overall system performance. In this work, a Dual-Circuit Secondary Loop (DCSL) EVs heat pump system based on R290 was designed, and the heating performance of the system was analyzed at different compressor speeds for changes in indoor air velocity, electronic expansion valve (EEV) opening, coolant flow rate, and ambient temperatures, together with the degree of exergy destruction was evaluated at low temperatures. The result shows that the maximum heating capacity of the system reaches about 4,383 W with the COP of 2.1 at an ambient temperature of -20 °C. The heating capacity of the DCSL increases first and then reduces with with the EEV opening and the coolant flow rate, more important, the EEV opening shows a greater effect on heating capacity than coolant flow rate. As a compressor rotational speed of 4,000 rpm, the increase and decrease in heating capacity due to the EEV opening change can reach 66% and 21%, respectively, while coolant flow rates can cause only 3% to 5% heating capacity fluctuations. Furthermore, the heat transfer efficiency of DCSL decreased with the increasing of coolant flow rates, with a maximum average efficiency drop of 11%. And when the ambient temperature drops to -20°C, the average heat transfer efficiency is only 0.53, which is a 17.5% drop compared to -10°C. Analysis of the exergy destruction reveals that as the ambient temperature decreases to -20°C, the main sources of increase in exergy destruction are the Outdoor Heat Exchanger and the In-vehicle Condenser, with an increase of 5.7% and 10.1%, respectively.
- 7 February 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 353
Experimental and numerical investigations of water–ice phase change under non-uniform cold source configurations
- 7 February 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 353
Experimental and numerical investigations of water–ice phase change under non-uniform cold source configurations
- 2 February 2026
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 65 (5) , 2928-2944
Thermodynamic Modeling of Ionic Liquids with PC-SAFT: Quantifying the Impact of Association and Dipolar Terms
- 2 February 2026
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 65 (5) , 2928-2944
Thermodynamic Modeling of Ionic Liquids with PC-SAFT: Quantifying the Impact of Association and Dipolar Terms