Pedinti Sankaran Venkateswaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Pedinti Sankaran Venkateswaran has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Sanket Goel
4 shared publicationsAbhishek Sharma
3 shared publicationsAjay Agarwal
3 shared publicationsDiwakar Kashyap
2 shared publicationsJitendra K. Pandey
2 shared publications- Sanket Goel
Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad, India
2 shared publications
Latest Publications
- 1 July 2017
- Published by American Scientific Publishers in Sensor Letters
- Vol. 15 (7) , 545-551
Stereolithographic 3D Printed Microfluidic Viscometer for Rapid Detection of Automobile Fuel Adulteration
Evidently, development of lab-on-a-chip platform to monitor various physical parameters, such as density, pressure, diffusivity, viscosity etc., has enormous potential and wide-ranging applications in the diagnostics and medical fields. Although, various microviscometers have been developed in the past, they still possess limited applications due to their lack of reproducibility in measurements and limit-of-detection. In the present work, we describe the experimental validation of a 3D printed microviscometer for measuring adulteration of gasoline (petrol) with diesel and kerosene. The device analyzes the change in dynamic viscosity based on width occupancy of the fluids inside a microchannel. This microviscometer has been designed and fabricated using the Stereolithography (SLA) based Digital Light Processing (DLP) 3D printer. The tests were conducted on samples of several blending ratios of petrol, diesel and kerosene, and the results were found within an accuracy of 0.95. This device possesses several advantages like ease of operation, simple design and automation capabilities. Further, the device is amenable to be implemented in various applications where viscosity is the monitoring parameter.
- 1 July 2017
- Published by American Scientific Publishers in Sensor Letters
- Vol. 15 (7) , 545-551
Stereolithographic 3D Printed Microfluidic Viscometer for Rapid Detection of Automobile Fuel Adulteration
Evidently, development of lab-on-a-chip platform to monitor various physical parameters, such as density, pressure, diffusivity, viscosity etc., has enormous potential and wide-ranging applications in the diagnostics and medical fields. Although, various microviscometers have been developed in the past, they still possess limited applications due to their lack of reproducibility in measurements and limit-of-detection. In the present work, we describe the experimental validation of a 3D printed microviscometer for measuring adulteration of gasoline (petrol) with diesel and kerosene. The device analyzes the change in dynamic viscosity based on width occupancy of the fluids inside a microchannel. This microviscometer has been designed and fabricated using the Stereolithography (SLA) based Digital Light Processing (DLP) 3D printer. The tests were conducted on samples of several blending ratios of petrol, diesel and kerosene, and the results were found within an accuracy of 0.95. This device possesses several advantages like ease of operation, simple design and automation capabilities. Further, the device is amenable to be implemented in various applications where viscosity is the monitoring parameter.
- 18 September 2016
- Published by Springer Nature
- p. 435-441
Air Mouse: An Everyday Mouse for the Ease of Computing
- 18 September 2016
- Published by Springer Nature
- p. 435-441
Air Mouse: An Everyday Mouse for the Ease of Computing
- 11 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 16 (9) , 3000-3007
Rapid and Automated Measurement of Milk Adulteration Using a 3D Printed Optofluidic Microviscometer (OMV)
In developing countries like India, adulteration in the milk consumed by the population presents stern implications as tarnishing of the same poses serious issues, such as health deterioration, corruption, and so on. There are many adulterants that are added to milk, including water, flour, starch, and even urea, in quantitative measures making it undetectable. There are many devices in the market to measure adulteration in milk but most of them are bulky, require large sample volume, and need a technical operator for working. In the recent decade, microfluidics has emerged as a huge market for biomedical research. It has paved the pathway for a quick, robust, and plug-and-play device for various applications. This paper describes a low-cost, durable, and simple optofluidic microviscometer fabricated by the stereolithography technique. The device operation is based on the linear relationship between dynamic viscosity and channel width derived from the flow of two immiscible fluids inside a channel. The principle of operation is based on the modified Hagen-Poiseuille flow equation. The working principle is the viscosity-dependent capture of the microchannel width by the fluids flowing inside the microchannel under the laminar flow based on the pressure gradient between the inlets and the outlet. In this paper, around 60 milk samples with various adulteration ratios of various adulterants ranging from 1% to 10% have been tested. A best fit curve for every adulterant was defined, and the device was found to be accurate enough to measure the entire range of adulteration ratios with a high accuracy of 0.95.
- 11 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 16 (9) , 3000-3007
Rapid and Automated Measurement of Milk Adulteration Using a 3D Printed Optofluidic Microviscometer (OMV)
In developing countries like India, adulteration in the milk consumed by the population presents stern implications as tarnishing of the same poses serious issues, such as health deterioration, corruption, and so on. There are many adulterants that are added to milk, including water, flour, starch, and even urea, in quantitative measures making it undetectable. There are many devices in the market to measure adulteration in milk but most of them are bulky, require large sample volume, and need a technical operator for working. In the recent decade, microfluidics has emerged as a huge market for biomedical research. It has paved the pathway for a quick, robust, and plug-and-play device for various applications. This paper describes a low-cost, durable, and simple optofluidic microviscometer fabricated by the stereolithography technique. The device operation is based on the linear relationship between dynamic viscosity and channel width derived from the flow of two immiscible fluids inside a channel. The principle of operation is based on the modified Hagen-Poiseuille flow equation. The working principle is the viscosity-dependent capture of the microchannel width by the fluids flowing inside the microchannel under the laminar flow based on the pressure gradient between the inlets and the outlet. In this paper, around 60 milk samples with various adulteration ratios of various adulterants ranging from 1% to 10% have been tested. A best fit curve for every adulterant was defined, and the device was found to be accurate enough to measure the entire range of adulteration ratios with a high accuracy of 0.95.
- Top Cited Papers
- 1 November 2015
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 51, 623-633
Hydrogen: A sustainable fuel for future of the transport sector
- 1 November 2015
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 51, 623-633
Top Cited PapersHydrogen: A sustainable fuel for future of the transport sector
- 1 September 2015
- Published by American Scientific Publishers in Journal of Computational and Theoretical Nanoscience
- Vol. 12 (9) , 2311-2317
Computational Analysis of a Microfluidic Viscometer and Its Application in the Rapid and Automated Measurement of Biodiesel Blending Under Pressure Driven Flow
The fossil fuels are depleting with time, hence the research work in the area of alternate energy is growing; thereby providing an abundant scope for biofuel production and deployment. It is well known that the fuel mixture directly affects the performance and efficiency of any automobile. The various physical properties that govern the fuel mixture are viscosity, concentration, additives, boiling point, melting point, etc. Hence, developing a sensor, based on such physical properties, can provide a reliable and effective solution to detect and monitor the biodiesel blending. This research paper describes the computational analysis of a Y-shaped microfluidic device which performs various fluidic operations by analyzing physical properties and their variations. The idea behind this study is to find out the adherence of the device to the Hagen-Poiseuille flow equation. The working principle in this case is concentration dependent width capture by the fluids flowing in the channels based on the pressure difference in the inlet and outlet ports. The different physical characteristics with their test results for various blending ratios of diesel with biodiesel have been shown in this study. Such microfluidic devices also have other viscosity based sensing and monitoring applications such as hemoglobin detection, food adulteration etc.
- 1 September 2015
- Published by American Scientific Publishers in Journal of Computational and Theoretical Nanoscience
- Vol. 12 (9) , 2311-2317
Computational Analysis of a Microfluidic Viscometer and Its Application in the Rapid and Automated Measurement of Biodiesel Blending Under Pressure Driven Flow
The fossil fuels are depleting with time, hence the research work in the area of alternate energy is growing; thereby providing an abundant scope for biofuel production and deployment. It is well known that the fuel mixture directly affects the performance and efficiency of any automobile. The various physical properties that govern the fuel mixture are viscosity, concentration, additives, boiling point, melting point, etc. Hence, developing a sensor, based on such physical properties, can provide a reliable and effective solution to detect and monitor the biodiesel blending. This research paper describes the computational analysis of a Y-shaped microfluidic device which performs various fluidic operations by analyzing physical properties and their variations. The idea behind this study is to find out the adherence of the device to the Hagen-Poiseuille flow equation. The working principle in this case is concentration dependent width capture by the fluids flowing in the channels based on the pressure difference in the inlet and outlet ports. The different physical characteristics with their test results for various blending ratios of diesel with biodiesel have been shown in this study. Such microfluidic devices also have other viscosity based sensing and monitoring applications such as hemoglobin detection, food adulteration etc.
- 1 June 2015
- Published by Elsevier in Electrochimica Acta
- Vol. 167, 213-218
Fabrication of Vertically aligned Copper Nanotubes as a Novel Electrode for Enzymatic Biofuel Cells
- 1 June 2015
- Published by Elsevier in Electrochimica Acta
- Vol. 167, 213-218
Fabrication of Vertically aligned Copper Nanotubes as a Novel Electrode for Enzymatic Biofuel Cells
- 1 January 2012
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 12 (1) , 75-83
Dopant Induced Bandgap Narrowing in Y-Doped Zinc Oxide Nanostructures
In this report, hydrothermal synthesis and the absorption properties of the cubic shaped zinc oxide nanostructures doped with different amount of yttrium (Y) metal cation (0 to 15 at.%) are demonstrated. The structural and optical properties of chemically synthesized pure and Y doped ZnO powders are investigated by using powder X-ray diffraction (XRD), field emission scanning electron spectroscopy (FESEM) and transmission electron microscopy (TEM), ultraviolet-visible (UV-vis) absorbance, photoluminescence (PL), and Fourier transform infra-red spectroscopy (FT-IR). It is found that the dopant ions stabilize in wurtzite hexagonal phase of ZnO upto the concentration of less than 6 at.%, which is mainly due to the fact that the ZnO lattice expands and the optical bandgap energy decreases at this level. Increasing the dopant concentration to greater than 6 at.% leads to a contraction of the lattice, which in turn produces a significant structural disorder evidenced by shift in the XRD peaks due to additional interstitial incorporation of Y. The vibrational modes of the metal oxide groups have been identified from the IR transmission spectra. The optical absorption results show that the optical bandgap energy of Y:ZnO nanocrystals is much less as compared to that of the pure bulk ZnO particles. Doping ZnO with trivalent Y produces excess number of electrons in the conduction band and thus, shifts the absorption edge and narrows down to 80 meV approximately. PL spectra are used to study the dependence of doping on the deep-level emission, which show an enhanced blue emission after Y doping. The existence of near band edge (NBE) emission and blue emission, related to zinc interstitials are observed in the luminescence spectra of Zn1−x Y x O nanostructures.
- 1 January 2012
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 12 (1) , 75-83
Dopant Induced Bandgap Narrowing in Y-Doped Zinc Oxide Nanostructures
In this report, hydrothermal synthesis and the absorption properties of the cubic shaped zinc oxide nanostructures doped with different amount of yttrium (Y) metal cation (0 to 15 at.%) are demonstrated. The structural and optical properties of chemically synthesized pure and Y doped ZnO powders are investigated by using powder X-ray diffraction (XRD), field emission scanning electron spectroscopy (FESEM) and transmission electron microscopy (TEM), ultraviolet-visible (UV-vis) absorbance, photoluminescence (PL), and Fourier transform infra-red spectroscopy (FT-IR). It is found that the dopant ions stabilize in wurtzite hexagonal phase of ZnO upto the concentration of less than 6 at.%, which is mainly due to the fact that the ZnO lattice expands and the optical bandgap energy decreases at this level. Increasing the dopant concentration to greater than 6 at.% leads to a contraction of the lattice, which in turn produces a significant structural disorder evidenced by shift in the XRD peaks due to additional interstitial incorporation of Y. The vibrational modes of the metal oxide groups have been identified from the IR transmission spectra. The optical absorption results show that the optical bandgap energy of Y:ZnO nanocrystals is much less as compared to that of the pure bulk ZnO particles. Doping ZnO with trivalent Y produces excess number of electrons in the conduction band and thus, shifts the absorption edge and narrows down to 80 meV approximately. PL spectra are used to study the dependence of doping on the deep-level emission, which show an enhanced blue emission after Y doping. The existence of near band edge (NBE) emission and blue emission, related to zinc interstitials are observed in the luminescence spectra of Zn1−x Y x O nanostructures.