Miguel de Figueiredo
Miguel de Figueiredo has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Delphine Jouan-Rimbaud Bouveresse
Ingénierie Procédés Aliments, AgroParisTech, Inra, Université Paris-Saclay, 91300 Massy, France; Physiologie de la Nutrition et du Comportement Alimentaire, AgroParisTech, Inra, Université Paris-Saclay, 75005 Paris, France
3 shared publications- Douglas Neil Rutledge
Université Paris-Saclay, Stratégies d'investigations analytiques: Médicaments, bioMatériaux, tissus et Matrices biologiques, 91400, Orsay, France
3 shared publications Jean-Marc Bégué
Laboratoire Central de la Préfecture de Police, 39bis rue de Dantzig, 75015 Paris, France
3 shared publications- Julien Boccard
School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland
3 shared publications - Serge Rudaz
School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland
3 shared publications Xavier Archer
Laboratoire Central de la Préfecture de Police, 39bis rue de Dantzig, 75015 Paris, France
3 shared publications
Latest Publications
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Évaluation d'une approche chimiométrique non ciblée pour l'inférence de source de liquides inflammables en science forensique
L’identification des auteurs d’incendies criminels où un accélérant a été utilisé demeure à ce jour un domaine de recherche en développement. Les traces biologiques reines pour l’identification de personnes comme l’ADN et les traces papillaires sont généralement détruites, donc rarement recherchées. Pourtant, lier l’auteur des faits au lieu de l’incendie est un réel besoin. Ce lien pourrait être établi par l’inférence de source des traces d’accélérant détectées sur les lieux avec une source potentielle souvent amenée par l’enquête comme des objets saisis en possession du suspect (vêtements), un jerrican ou encore des prélèvements effectués sur ses mains. Dès lors, la question qui se pose consiste à déterminer si les traces d’accélérant détectées sur les lieux et les traces détectées sur l’élément de comparaison partagent une source commune. Ainsi, l’inférence de source de l’accélérant constitue une alternative au manque de traces matérielles de sorte à fournir des éléments de preuve à la suite d’un incendie volontaire. En ce sens, cette recherche propose une approche chimiométrique non ciblée pour l’inférence de source de liquides inflammables en science forensique. Cette approche a été appliquée à un échantillonnage conséquent d’essences non altérées et à un échantillonnage réduit d’essences altérées de 0 à 99% par évaporation et par combustion. L’évaluation des résultats a validé l’hypothèse selon laquelle il est possible de lier des échantillons d’essences altérés ou non, par évaporation ou combustion, indépendamment du mode et du degré d’altération.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Évaluation d'une approche chimiométrique non ciblée pour l'inférence de source de liquides inflammables en science forensique
L’identification des auteurs d’incendies criminels où un accélérant a été utilisé demeure à ce jour un domaine de recherche en développement. Les traces biologiques reines pour l’identification de personnes comme l’ADN et les traces papillaires sont généralement détruites, donc rarement recherchées. Pourtant, lier l’auteur des faits au lieu de l’incendie est un réel besoin. Ce lien pourrait être établi par l’inférence de source des traces d’accélérant détectées sur les lieux avec une source potentielle souvent amenée par l’enquête comme des objets saisis en possession du suspect (vêtements), un jerrican ou encore des prélèvements effectués sur ses mains. Dès lors, la question qui se pose consiste à déterminer si les traces d’accélérant détectées sur les lieux et les traces détectées sur l’élément de comparaison partagent une source commune. Ainsi, l’inférence de source de l’accélérant constitue une alternative au manque de traces matérielles de sorte à fournir des éléments de preuve à la suite d’un incendie volontaire. En ce sens, cette recherche propose une approche chimiométrique non ciblée pour l’inférence de source de liquides inflammables en science forensique. Cette approche a été appliquée à un échantillonnage conséquent d’essences non altérées et à un échantillonnage réduit d’essences altérées de 0 à 99% par évaporation et par combustion. L’évaluation des résultats a validé l’hypothèse selon laquelle il est possible de lier des échantillons d’essences altérés ou non, par évaporation ou combustion, indépendamment du mode et du degré d’altération.
- 4 December 2025
- Published by Wiley in Drug Testing and Analysis
- Vol. 18 (2) , 239-244
Assessing the Effect of Probiotics in the Steroidal Module of the Athlete's Biological Passport
Athletes are increasingly using probiotic supplementation to support their overall health, and it can be particularly beneficial for female athletes in managing recurrent urinary tract infections and bacterial vaginosis. One route of probiotic administration for females is vaginal application, which enables direct modulation of the microbiota. While probiotics are widely recognised for their health benefits, their potential impact on urinary steroidal markers monitored in the Steroidal Module of the Athlete Biological Passport remains unexplored. Given the biological overlap between vaginal and urinary microbiomes, bacteria from vaginal probiotics could transfer into urine samples, potentially altering steroid profiles through microbial enzymatic activity. This study investigates whether vaginal probiotic use, specifically Lactobacillus reuteri and plantaraium , could influence urinary steroid markers relevant to the steroidal passport. In vitro and in vivo approaches were employed to evaluate the potential effects of contamination and variability on key steroidal markers. Analyses of in vitro and in vivo experiments suggest that vaginal probiotics do not substantially affect urinary steroid markers monitored in the Athlete Biological Passport. However, some variations were observed that merit further investigation. These findings contribute to a better understanding of how vaginal probiotics might interfere with doping control results, emphasising the need for further research to ensure accurate interpretation of urine steroidal profiles in the female athlete.
- 4 December 2025
- Published by Wiley in Drug Testing and Analysis
- Vol. 18 (2) , 239-244
Assessing the Effect of Probiotics in the Steroidal Module of the Athlete's Biological Passport
Athletes are increasingly using probiotic supplementation to support their overall health, and it can be particularly beneficial for female athletes in managing recurrent urinary tract infections and bacterial vaginosis. One route of probiotic administration for females is vaginal application, which enables direct modulation of the microbiota. While probiotics are widely recognised for their health benefits, their potential impact on urinary steroidal markers monitored in the Steroidal Module of the Athlete Biological Passport remains unexplored. Given the biological overlap between vaginal and urinary microbiomes, bacteria from vaginal probiotics could transfer into urine samples, potentially altering steroid profiles through microbial enzymatic activity. This study investigates whether vaginal probiotic use, specifically Lactobacillus reuteri and plantaraium , could influence urinary steroid markers relevant to the steroidal passport. In vitro and in vivo approaches were employed to evaluate the potential effects of contamination and variability on key steroidal markers. Analyses of in vitro and in vivo experiments suggest that vaginal probiotics do not substantially affect urinary steroid markers monitored in the Athlete Biological Passport. However, some variations were observed that merit further investigation. These findings contribute to a better understanding of how vaginal probiotics might interfere with doping control results, emphasising the need for further research to ensure accurate interpretation of urine steroidal profiles in the female athlete.
- Open Access
- 14 April 2025
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 262
Integration of multifactorial omics data from several sources using multiblock methods
- 14 April 2025
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 262
Open AccessIntegration of multifactorial omics data from several sources using multiblock methods
- 7 April 2025
- Published by Wiley in Drug Testing and Analysis
- Vol. 17 (10) , 1865-1876
Evaluating the Early Operational Performance of the Endocrine Module in the Athlete Biological Passport
In collaboration with various Anti‐Doping Organisations and the Paris WADA‐accredited laboratory, the International Testing Agency spearheaded the implementation of the Endocrine Module ahead of the Olympic Games Paris 2024. This article presents a data‐driven evaluation of its early integration within Athlete Biological Passport (ABP) programs. The assessment of endocrine profile testing follows the complete ABP sample lifecycle, from collection to the submission of reports by the Athlete Passport Management Unit. The article identifies both challenges and opportunities by integrating testing, analytical and ABP perspectives and offers recommendations for the future development of the Endocrine Module. Furthermore, it explores the Endocrine Module's synergy with the Haematological and Steroidal Modules emphasising on key areas for the enhancement of ABP programs as a whole.
- 7 April 2025
- Published by Wiley in Drug Testing and Analysis
- Vol. 17 (10) , 1865-1876
Evaluating the Early Operational Performance of the Endocrine Module in the Athlete Biological Passport
In collaboration with various Anti‐Doping Organisations and the Paris WADA‐accredited laboratory, the International Testing Agency spearheaded the implementation of the Endocrine Module ahead of the Olympic Games Paris 2024. This article presents a data‐driven evaluation of its early integration within Athlete Biological Passport (ABP) programs. The assessment of endocrine profile testing follows the complete ABP sample lifecycle, from collection to the submission of reports by the Athlete Passport Management Unit. The article identifies both challenges and opportunities by integrating testing, analytical and ABP perspectives and offers recommendations for the future development of the Endocrine Module. Furthermore, it explores the Endocrine Module's synergy with the Haematological and Steroidal Modules emphasising on key areas for the enhancement of ABP programs as a whole.
- Open Access
- 1 September 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (36) , 13546-13554
Multitargeted Internal Calibration for the Quantification of Chronic Kidney Disease-Related Endogenous Metabolites Using Liquid Chromatography–Mass Spectrometry
Accurate quantitative analysis in liquid chromatography-mass spectrometry (LC-MS) benefits from calibration curves generated in the same matrix as the study sample. In the case of endogenous compound quantification, as no blank matrix exists, the multitargeted internal calibration (MTIC) is an attractive and straightforward approach to avoid the need for extensive matrix similarity evaluation. Its principle is to take advantage of stable isotope labeled (SIL) standards as internal calibrants to simultaneously quantify authentic analytes using a within sample calibration. An MTIC workflow was developed for the simultaneous quantification of metabolites related to chronic kidney disease (CKD) using a volumetric microsampling device to collect 20 μL of serum or plasma, followed by a single-step extraction with acetonitrile/water and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Since a single concentration of internal calibrant is necessary to calculate the study sample concentration, the instrument response function was investigated to determine the best SIL concentration. After validation, the trueness of 16 endogenous analytes in authentic human serum ranged from 72.2 to 116.0%, the repeatability from 1.9 to 11.3%, and the intermediate precision ranged overall from 2.1 to 15.4%. The proposed approach was applied to plasma samples collected from healthy control participants and two patient groups diagnosed with CKD. Results confirmed substantial concentration differences between groups for several analytes, including indoxyl sulfate and cortisone, as well as metabolite enrichment in the kynurenine and indole pathways. Multitargeted methodologies represent a major step toward rapid and straightforward LC-MS/MS absolute quantification of endogenous biomarkers, which could change the paradigm of MS use in clinical laboratories.
- 1 September 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (36) , 13546-13554
Open AccessMultitargeted Internal Calibration for the Quantification of Chronic Kidney Disease-Related Endogenous Metabolites Using Liquid Chromatography–Mass Spectrometry
Accurate quantitative analysis in liquid chromatography-mass spectrometry (LC-MS) benefits from calibration curves generated in the same matrix as the study sample. In the case of endogenous compound quantification, as no blank matrix exists, the multitargeted internal calibration (MTIC) is an attractive and straightforward approach to avoid the need for extensive matrix similarity evaluation. Its principle is to take advantage of stable isotope labeled (SIL) standards as internal calibrants to simultaneously quantify authentic analytes using a within sample calibration. An MTIC workflow was developed for the simultaneous quantification of metabolites related to chronic kidney disease (CKD) using a volumetric microsampling device to collect 20 μL of serum or plasma, followed by a single-step extraction with acetonitrile/water and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Since a single concentration of internal calibrant is necessary to calculate the study sample concentration, the instrument response function was investigated to determine the best SIL concentration. After validation, the trueness of 16 endogenous analytes in authentic human serum ranged from 72.2 to 116.0%, the repeatability from 1.9 to 11.3%, and the intermediate precision ranged overall from 2.1 to 15.4%. The proposed approach was applied to plasma samples collected from healthy control participants and two patient groups diagnosed with CKD. Results confirmed substantial concentration differences between groups for several analytes, including indoxyl sulfate and cortisone, as well as metabolite enrichment in the kynurenine and indole pathways. Multitargeted methodologies represent a major step toward rapid and straightforward LC-MS/MS absolute quantification of endogenous biomarkers, which could change the paradigm of MS use in clinical laboratories.
- Open Access
- 2 May 2022
- Published by Wiley in Journal of Chemometrics
- Vol. 37 (7)
Efficiently handling high‐dimensional data from multifactorial designs with unequal group sizes using Rebalanced ASCA (RASCA)
A novel chemometric approach is proposed to analyze high‐dimensional data from unbalanced designs of experiments. It combines a rebalancing strategy based on averages with the ASCA method under the name Rebalanced ASCA (RASCA). The ability of RASCA to handle unbalanced designs was compared with standard ASCA, as well as state‐of‐the‐art methods, such as ASCA+ and WE‐ASCA. For that purpose, a controlled framework was designed to provide a systematic comparison of the various approaches. It included two real datasets obtained from initially balanced designs, which were gradually unbalanced by removing observations belonging to specific combinations of factor levels. The results illustrate that all methods considered led to identical solutions when the initial balanced design was kept. Nevertheless, increasing differences appeared when the design was gradually unbalanced. The proposed benchmark showed that RASCA and ASCA+ provided overall similar results for all effects with high agreement with the balanced solutions in comparison to classical ASCA and WE‐ASCA. RASCA was found to be a suitable chemometric tool to tackle unbalanced designs by ensuring unbiased parameter estimators with the added benefit of producing rigorously orthogonal effect matrices, thus facilitating interpretation.
- 2 May 2022
- Published by Wiley in Journal of Chemometrics
- Vol. 37 (7)
Open AccessEfficiently handling high‐dimensional data from multifactorial designs with unequal group sizes using Rebalanced ASCA (RASCA)
A novel chemometric approach is proposed to analyze high‐dimensional data from unbalanced designs of experiments. It combines a rebalancing strategy based on averages with the ASCA method under the name Rebalanced ASCA (RASCA). The ability of RASCA to handle unbalanced designs was compared with standard ASCA, as well as state‐of‐the‐art methods, such as ASCA+ and WE‐ASCA. For that purpose, a controlled framework was designed to provide a systematic comparison of the various approaches. It included two real datasets obtained from initially balanced designs, which were gradually unbalanced by removing observations belonging to specific combinations of factor levels. The results illustrate that all methods considered led to identical solutions when the initial balanced design was kept. Nevertheless, increasing differences appeared when the design was gradually unbalanced. The proposed benchmark showed that RASCA and ASCA+ provided overall similar results for all effects with high agreement with the balanced solutions in comparison to classical ASCA and WE‐ASCA. RASCA was found to be a suitable chemometric tool to tackle unbalanced designs by ensuring unbiased parameter estimators with the added benefit of producing rigorously orthogonal effect matrices, thus facilitating interpretation.
- 22 January 2022
- Published by Wiley in Journal of Chemometrics
- Vol. 37 (7) , e3384
A tutorial on the analysis of multifactorial designs from one or more data sources using AComDim
To analyze data acquired from experiments based on multifactorial designs, approaches able to decompose and model the main sources of variation in the measurements are particularly useful. Although methods combining analysis of variance (ANOVA) with principal components analysis (PCA) or simultaneous components analysis (SCA), namely, ANOVA‐PCA (APCA) and ANOVA‐SCA (ASCA), have proven to be efficient to tackle such data structures, they require the construction and interpretation of a model for each experimental factor and interaction. Other methods like parallel factor analysis‐SCA (PARAFASCA), ANOVA multiblock orthogonal partial least squares (AMOPLS) and ANOVA‐Common Dimensions (AComDim) offer the possibility to have an overall picture of all the sources of variation by means of a single model. Moreover, acquiring data from one or multiple data sources through the same experimental design is becoming more common, and approaches able to cope with such complex data structures are needed. In this tutorial, an explanation of the theory and software implementation of AComDim as well as its usage for the analysis of data acquired from experimental designs is provided. Relying on the multiblock nature of AComDim, an extension to cases where data from multiple sources are acquired on the same samples is proposed.
- 22 January 2022
- Published by Wiley in Journal of Chemometrics
- Vol. 37 (7) , e3384
A tutorial on the analysis of multifactorial designs from one or more data sources using AComDim
To analyze data acquired from experiments based on multifactorial designs, approaches able to decompose and model the main sources of variation in the measurements are particularly useful. Although methods combining analysis of variance (ANOVA) with principal components analysis (PCA) or simultaneous components analysis (SCA), namely, ANOVA‐PCA (APCA) and ANOVA‐SCA (ASCA), have proven to be efficient to tackle such data structures, they require the construction and interpretation of a model for each experimental factor and interaction. Other methods like parallel factor analysis‐SCA (PARAFASCA), ANOVA multiblock orthogonal partial least squares (AMOPLS) and ANOVA‐Common Dimensions (AComDim) offer the possibility to have an overall picture of all the sources of variation by means of a single model. Moreover, acquiring data from one or multiple data sources through the same experimental design is becoming more common, and approaches able to cope with such complex data structures are needed. In this tutorial, an explanation of the theory and software implementation of AComDim as well as its usage for the analysis of data acquired from experimental designs is provided. Relying on the multiblock nature of AComDim, an extension to cases where data from multiple sources are acquired on the same samples is proposed.
- 1 August 2019
- Published by Elsevier in Forensic Science International
- Vol. 301, 190-201
Exploratory study on the possibility to link gasoline samples sharing a common source after alteration by evaporation or combustion
- 1 August 2019
- Published by Elsevier in Forensic Science International
- Vol. 301, 190-201
Exploratory study on the possibility to link gasoline samples sharing a common source after alteration by evaporation or combustion
- 1 February 2019
- Published by Elsevier in Forensic Science International
- Vol. 295, 8-18
Evaluation of an untargeted chemometric approach for the source inference of ignitable liquids in forensic science
- 1 February 2019
- Published by Elsevier in Forensic Science International
- Vol. 295, 8-18
Evaluation of an untargeted chemometric approach for the source inference of ignitable liquids in forensic science
- Open Access
- 1 June 2018
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 177, 35-46
A variable selection method for multiclass classification problems using two-class ROC analysis
- 1 June 2018
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 177, 35-46
Open AccessA variable selection method for multiclass classification problems using two-class ROC analysis