Mohamad Nageeb Hassan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohamad Nageeb Hassan has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Sherif Kandil
Department of Materials Science, Institute of Graduate Studies and Research (IGSR), Alexandria University, El-Shatby, Alexandria 21526, Egypt
5 shared publications- Kamal Mustafa
Department of Clinical Dentistry, University of Bergen, Bergen, Norway
4 shared publications Ahmed Abd El-Fattah
3 shared publicationsAhmed Maher Eltawila
Department of Materials Science, Institute of Graduate Studies and Research (IGSR), Alexandria University, El-Shatby, Alexandria 21526, Egypt
2 shared publications- Mohammed Ahmed Yassin
University of Bergen
2 shared publications - Morsi Mohamed Mahmoud
Genomic and Biotechnology Research Group, Department of Biological Sciences, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
2 shared publications
Latest Publications
- Open Access
- 25 May 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (22) , 28056-28069
Correlation between Ca Release and Osteoconduction by 3D-Printed Hydroxyapatite-Based Templates
The application of hydroxyapatite (HA)-based templates is quite often seen in bone tissue engineering since that HA is an osteoconductive bioceramic material, which mimics the inorganic component of mineralized tissues. However, the reported osteoconductivity varies in vitro and in vivo, and the levels of calcium (Ca) release most favorable to osteoconduction have yet to be determined. In this study, HA-based templates were fabricated by melt-extrusion 3D-printing and characterized in order to determine a possible correlation between Ca release and osteoconduction. The HA-based templates were blended with poly(lactide-co-trimethylene carbonate) (PLATMC) at three different HA ratios: 10, 30, and 50%. The printability and physical properties of the HA templates were compared with those of pristine PLATMC. In vitro, osteoconductivity was assessed using seeded human bone marrow-derived mesenchymal stem cells. A mild rate of Ca release was observed for HA10 templates, which exhibited higher mineralized extracellular matrix (ECM) secretion than PLATMC at 14 and 21 days. In contrast, the high rate of Ca release exhibited by HA30 and HA50 templates was associated with reduced osteoconduction and impeded mineralized ECM secretion in vitro. Similar results were observed in vivo. In the calvarial defect model in rabbit, PLATMC and HA10 templates exhibited the highest amount of new bone formation, with obvious contact osteogenesis on their surfaces. In contrast, HA30 and HA50 exhibited distant osteogenesis and reduced amounts of new bone ingrowth. It is concluded that HA-based templates are osteoconductive only at low rates of Ca release.
- 25 May 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (22) , 28056-28069
Open AccessCorrelation between Ca Release and Osteoconduction by 3D-Printed Hydroxyapatite-Based Templates
The application of hydroxyapatite (HA)-based templates is quite often seen in bone tissue engineering since that HA is an osteoconductive bioceramic material, which mimics the inorganic component of mineralized tissues. However, the reported osteoconductivity varies in vitro and in vivo, and the levels of calcium (Ca) release most favorable to osteoconduction have yet to be determined. In this study, HA-based templates were fabricated by melt-extrusion 3D-printing and characterized in order to determine a possible correlation between Ca release and osteoconduction. The HA-based templates were blended with poly(lactide-co-trimethylene carbonate) (PLATMC) at three different HA ratios: 10, 30, and 50%. The printability and physical properties of the HA templates were compared with those of pristine PLATMC. In vitro, osteoconductivity was assessed using seeded human bone marrow-derived mesenchymal stem cells. A mild rate of Ca release was observed for HA10 templates, which exhibited higher mineralized extracellular matrix (ECM) secretion than PLATMC at 14 and 21 days. In contrast, the high rate of Ca release exhibited by HA30 and HA50 templates was associated with reduced osteoconduction and impeded mineralized ECM secretion in vitro. Similar results were observed in vivo. In the calvarial defect model in rabbit, PLATMC and HA10 templates exhibited the highest amount of new bone formation, with obvious contact osteogenesis on their surfaces. In contrast, HA30 and HA50 exhibited distant osteogenesis and reduced amounts of new bone ingrowth. It is concluded that HA-based templates are osteoconductive only at low rates of Ca release.
- Open Access
- 10 October 2022
- Published by American Association for the Advancement of Science (AAAS) in Biomaterials Research
- Vol. 26 (1) , 1-19
Contact osteogenesis by biodegradable 3D-printed poly(lactide-co-trimethylene carbonate)
Background: To support bone regeneration, 3D-printed templates function as temporary guides. The preferred materials are synthetic polymers, due to their ease of processing and biological inertness. Poly(lactide-co-trimethylene carbonate) (PLATMC) has good biological compatibility and currently used in soft tissue regeneration. The aim of this study was to evaluate the osteoconductivity of 3D-printed PLATMC templates for bone tissue engineering, in comparison with the widely used 3D-printed polycaprolactone (PCL) templates. Methods: The printability and physical properties of 3D-printed templates were assessed, including wettability, tensile properties and the degradation profile. Human bone marrow-derived mesenchymal stem cells (hBMSCs) were used to evaluate osteoconductivity and extracellular matrix secretion in vitro. In addition, 3D-printed templates were implanted in subcutaneous and calvarial bone defect models in rabbits. Results: Compared to PCL, PLATMC exhibited greater wettability, strength, degradation, and promoted osteogenic differentiation of hBMSCs, with superior osteoconductivity. However, the higher ALP activity disclosed by PCL group at 7 and 21 days did not dictate better osteoconductivity. This was confirmed in vivo in the calvarial defect model, where PCL disclosed distant osteogenesis, while PLATMC disclosed greater areas of new bone and obvious contact osteogenesis on surface. Conclusions: This study shows for the first time the contact osteogenesis formed on a degradable synthetic co-polymer. 3D-printed PLATMC templates disclosed unique contact osteogenesis and significant higher amount of new bone regeneration, thus could be used to advantage in bone tissue engineering.
- 10 October 2022
- Published by American Association for the Advancement of Science (AAAS) in Biomaterials Research
- Vol. 26 (1) , 1-19
Open AccessContact osteogenesis by biodegradable 3D-printed poly(lactide-co-trimethylene carbonate)
Background: To support bone regeneration, 3D-printed templates function as temporary guides. The preferred materials are synthetic polymers, due to their ease of processing and biological inertness. Poly(lactide-co-trimethylene carbonate) (PLATMC) has good biological compatibility and currently used in soft tissue regeneration. The aim of this study was to evaluate the osteoconductivity of 3D-printed PLATMC templates for bone tissue engineering, in comparison with the widely used 3D-printed polycaprolactone (PCL) templates. Methods: The printability and physical properties of 3D-printed templates were assessed, including wettability, tensile properties and the degradation profile. Human bone marrow-derived mesenchymal stem cells (hBMSCs) were used to evaluate osteoconductivity and extracellular matrix secretion in vitro. In addition, 3D-printed templates were implanted in subcutaneous and calvarial bone defect models in rabbits. Results: Compared to PCL, PLATMC exhibited greater wettability, strength, degradation, and promoted osteogenic differentiation of hBMSCs, with superior osteoconductivity. However, the higher ALP activity disclosed by PCL group at 7 and 21 days did not dictate better osteoconductivity. This was confirmed in vivo in the calvarial defect model, where PCL disclosed distant osteogenesis, while PLATMC disclosed greater areas of new bone and obvious contact osteogenesis on surface. Conclusions: This study shows for the first time the contact osteogenesis formed on a degradable synthetic co-polymer. 3D-printed PLATMC templates disclosed unique contact osteogenesis and significant higher amount of new bone regeneration, thus could be used to advantage in bone tissue engineering.
- Open Access
- 14 November 2021
- Published by Springer Nature in Stem Cell Research & Therapy
- Vol. 12 (1) , 1-17
Bone regeneration in rat calvarial defects using dissociated or spheroid mesenchymal stromal cells in scaffold-hydrogel constructs
Background: Three-dimensional (3D) spheroid culture can promote the osteogenic differentiation of bone marrow mesenchymal stromal cells (BMSC). 3D printing offers the possibility to produce customized scaffolds for complex bone defects. The aim of this study was to compare the potential of human BMSC cultured as 2D monolayers or 3D spheroids encapsulated in constructs of 3D-printed poly-L-lactide-co-trimethylene carbonate scaffolds and modified human platelet lysate hydrogels (PLATMC-HPLG) for bone regeneration. Methods: PLATMC-HPLG constructs with 2D or 3D BMSC were assessed for osteogenic differentiation based on gene expression and in vitro mineralization. Subsequently, PLATMC-HPLG constructs with 2D or 3D BMSC were implanted in rat calvarial defects for 12 weeks; cell-free constructs served as controls. Bone regeneration was assessed via in vivo computed tomography (CT), ex vivo micro-CT and histology. Results: Osteogenic gene expression was significantly enhanced in 3D versus 2D BMSC prior to, but not after, encapsulation in PLATMC-HPLG constructs. A trend for greater in vitro mineralization was observed in constructs with 3D versus 2D BMSC (p > 0.05). In vivo CT revealed comparable bone formation after 4, 8 and 12 weeks in all groups. After 12 weeks, micro-CT revealed substantial regeneration in 2D BMSC (62.47 ± 19.46%), 3D BMSC (51.01 ± 24.43%) and cell-free PLATMC-HPLG constructs (43.20 ± 30.09%) (p > 0.05). A similar trend was observed in the histological analysis. Conclusion: Despite a trend for superior in vitro mineralization, constructs with 3D and 2D BMSC performed similarly in vivo. Regardless of monolayer or spheroid cell culture, PLATMC-HPLG constructs represent promising scaffolds for bone tissue engineering applications.
- 14 November 2021
- Published by Springer Nature in Stem Cell Research & Therapy
- Vol. 12 (1) , 1-17
Open AccessBone regeneration in rat calvarial defects using dissociated or spheroid mesenchymal stromal cells in scaffold-hydrogel constructs
Background: Three-dimensional (3D) spheroid culture can promote the osteogenic differentiation of bone marrow mesenchymal stromal cells (BMSC). 3D printing offers the possibility to produce customized scaffolds for complex bone defects. The aim of this study was to compare the potential of human BMSC cultured as 2D monolayers or 3D spheroids encapsulated in constructs of 3D-printed poly-L-lactide-co-trimethylene carbonate scaffolds and modified human platelet lysate hydrogels (PLATMC-HPLG) for bone regeneration. Methods: PLATMC-HPLG constructs with 2D or 3D BMSC were assessed for osteogenic differentiation based on gene expression and in vitro mineralization. Subsequently, PLATMC-HPLG constructs with 2D or 3D BMSC were implanted in rat calvarial defects for 12 weeks; cell-free constructs served as controls. Bone regeneration was assessed via in vivo computed tomography (CT), ex vivo micro-CT and histology. Results: Osteogenic gene expression was significantly enhanced in 3D versus 2D BMSC prior to, but not after, encapsulation in PLATMC-HPLG constructs. A trend for greater in vitro mineralization was observed in constructs with 3D versus 2D BMSC (p > 0.05). In vivo CT revealed comparable bone formation after 4, 8 and 12 weeks in all groups. After 12 weeks, micro-CT revealed substantial regeneration in 2D BMSC (62.47 ± 19.46%), 3D BMSC (51.01 ± 24.43%) and cell-free PLATMC-HPLG constructs (43.20 ± 30.09%) (p > 0.05). A similar trend was observed in the histological analysis. Conclusion: Despite a trend for superior in vitro mineralization, constructs with 3D and 2D BMSC performed similarly in vivo. Regardless of monolayer or spheroid cell culture, PLATMC-HPLG constructs represent promising scaffolds for bone tissue engineering applications.
- 21 March 2021
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 109 (11) , 1677-1688
Local treatment of experimental mandibular osteomyelitis with an injectable biomimetic gentamicin hydrogel using a new rabbit model
Mandibular osteomyelitis (OM) is a challenging disease. Our objective was to assess a new OM model in rabbits induced by arsenic trioxide and to assess the efficacy of local treatment of OM using injectable gentamicin‐collagen hydrogels (GNT‐COLL). OM was induced unilaterally by controlled confinement of arsenic trioxide paste to the root canal of lower incisors of rabbits, while OM progression was characterized for 16 weeks. On the other hand, two injectable COLL hydrogels functionalized with GNT were prepared and characterized for physicochemical properties; a simple GNT‐COLL and a nanohydroxyapatite (nHA)‐ loaded hydrogel (GNT‐COLL/nHA). The two hydrogels were evaluated to treat OM model, while a multidose intramuscular GNT solution served as positive control. Outcomes were assessed by standard methods at 4 and 12 weeks post‐surgery. The clinical, radiographical, and histopathological findings provided evidence for the validity of the arsenic‐induced OM. The results demonstrated that a single intra‐lesional injection of the two hydrogels was more suppressive to OM compared to multidose systemic GNT. The composite GNT‐COLL/nHA hydrogel proved to induce early preservation of alveolar bone (ridge) length and higher amount of bone area\total area at 4 weeks (40.53% ± 2.34) followed by GNT‐COLL (32.21% ± 0.72). On the other hand, the positive control group revealed the least ridge length and bone area\total area (26.22% ± 1.32) at 4 weeks. Both hydrogels successfully arrested OM with no signs of recurrence for up to 12 weeks. Therefore, results support the greater advantages of the composite hydrogel as an osteogenic/antibiotic delivery system in OM treatment.
- 21 March 2021
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 109 (11) , 1677-1688
Local treatment of experimental mandibular osteomyelitis with an injectable biomimetic gentamicin hydrogel using a new rabbit model
Mandibular osteomyelitis (OM) is a challenging disease. Our objective was to assess a new OM model in rabbits induced by arsenic trioxide and to assess the efficacy of local treatment of OM using injectable gentamicin‐collagen hydrogels (GNT‐COLL). OM was induced unilaterally by controlled confinement of arsenic trioxide paste to the root canal of lower incisors of rabbits, while OM progression was characterized for 16 weeks. On the other hand, two injectable COLL hydrogels functionalized with GNT were prepared and characterized for physicochemical properties; a simple GNT‐COLL and a nanohydroxyapatite (nHA)‐ loaded hydrogel (GNT‐COLL/nHA). The two hydrogels were evaluated to treat OM model, while a multidose intramuscular GNT solution served as positive control. Outcomes were assessed by standard methods at 4 and 12 weeks post‐surgery. The clinical, radiographical, and histopathological findings provided evidence for the validity of the arsenic‐induced OM. The results demonstrated that a single intra‐lesional injection of the two hydrogels was more suppressive to OM compared to multidose systemic GNT. The composite GNT‐COLL/nHA hydrogel proved to induce early preservation of alveolar bone (ridge) length and higher amount of bone area\total area at 4 weeks (40.53% ± 2.34) followed by GNT‐COLL (32.21% ± 0.72). On the other hand, the positive control group revealed the least ridge length and bone area\total area (26.22% ± 1.32) at 4 weeks. Both hydrogels successfully arrested OM with no signs of recurrence for up to 12 weeks. Therefore, results support the greater advantages of the composite hydrogel as an osteogenic/antibiotic delivery system in OM treatment.
- 1 June 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 91, 1-23
The bone regeneration capacity of 3D-printed templates in calvarial defect models: A systematic review and meta-analysis
- 1 June 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 91, 1-23
The bone regeneration capacity of 3D-printed templates in calvarial defect models: A systematic review and meta-analysis
- 1 October 2016
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 682, 107-114
Sintering of naturally derived hydroxyapatite using high frequency microwave processing
- 1 October 2016
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 682, 107-114
Sintering of naturally derived hydroxyapatite using high frequency microwave processing
- 1 February 2016
- Published by Elsevier in Ceramics International
- Vol. 42 (3) , 3725-3744
Microwave-assisted preparation of Nano-hydroxyapatite for bone substitutes
- 1 February 2016
- Published by Elsevier in Ceramics International
- Vol. 42 (3) , 3725-3744
Microwave-assisted preparation of Nano-hydroxyapatite for bone substitutes
- 28 May 2015
- Published by Springer Nature in Journal of Sol-Gel Science and Technology
- Vol. 76 (1) , 74-81
Microwave rapid conversion of sol–gel-derived hydroxyapatite into β-tricalcium phosphate
- 28 May 2015
- Published by Springer Nature in Journal of Sol-Gel Science and Technology
- Vol. 76 (1) , 74-81
Microwave rapid conversion of sol–gel-derived hydroxyapatite into β-tricalcium phosphate