Pradyumna Lenka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pradyumna Lenka has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
R. M. Tripathi
Health Physics Division, Bhabha Atomic Research Centre, Mumbai, INDIA
7 shared publicationsJ. S. Dubey
Bhabha Atomic Research Centre
6 shared publications- Akhilesh Kumar Yadav
Department of Electronics and Communication Engineering, Manipal University Jaipur, Jaipur, India
5 shared publications S. K. Sahoo
Health Physics Division, Bhabha Atomic Research Centre, Mumbai, INDIA
5 shared publicationsS. Mohapatra
Bhabha Atomic Research Centre
5 shared publicationsSunil Kumar Sahoo
Scientific Officer, Health Physics Division, Bhabha Atomic Research Centre, Mumbai 400 085, India
5 shared publications
Latest Publications
- 8 September 2022
- Published by Springer Nature in Aerosol Science and Engineering
- Vol. 6 (4) , 414-436
Enrichment Factor and Chemical Composition of Size Separated Airborne Particulate Matter of Singrauli Coalfield, India
- 8 September 2022
- Published by Springer Nature in Aerosol Science and Engineering
- Vol. 6 (4) , 414-436
Enrichment Factor and Chemical Composition of Size Separated Airborne Particulate Matter of Singrauli Coalfield, India
- 1 January 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Hazardous, Toxic, and Radioactive Waste
- Vol. 24 (1)
Assessment of Radionuclide Concentration and Radiation Dose in Rock in Singrauli Coalfield, India
This study was conducted at the Singrauli coal mine environment in Singrauli coalfield, India. The activity concentrations of thorium ( ), uranium ( ), and potassium ( ) in rock samples were analyzed by gamma spectrometry using a -type high-purity germanium (HPGe) detector with a carbon fiber window. From terrestrial radionuclide activity concentration, the ambient radiation gamma dose rate was calculated using UNSCEAR 2000 coefficients. The average activity concentrations , , and were , , and , respectively. The average activity ratio of in various types of rocks was . The radium equivalent activity (Raeq) for various types of rock samples varied from to , with an average value of . The absorbed average gamma dose rate was . The annual average effective equivalent dose was .- 1 January 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Hazardous, Toxic, and Radioactive Waste
- Vol. 24 (1)
Assessment of Radionuclide Concentration and Radiation Dose in Rock in Singrauli Coalfield, India
This study was conducted at the Singrauli coal mine environment in Singrauli coalfield, India. The activity concentrations of thorium ( ), uranium ( ), and potassium ( ) in rock samples were analyzed by gamma spectrometry using a -type high-purity germanium (HPGe) detector with a carbon fiber window. From terrestrial radionuclide activity concentration, the ambient radiation gamma dose rate was calculated using UNSCEAR 2000 coefficients. The average activity concentrations , , and were , , and , respectively. The average activity ratio of in various types of rocks was . The radium equivalent activity (Raeq) for various types of rock samples varied from to , with an average value of . The absorbed average gamma dose rate was . The annual average effective equivalent dose was .- 7 August 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 307 (2) , 1499-1506
A study of natural uranium content in groundwater around Tummalapalle uranium mining and processing facility, India
- 7 August 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 307 (2) , 1499-1506
A study of natural uranium content in groundwater around Tummalapalle uranium mining and processing facility, India
- 26 March 2015
- Published by Wiley in Environmental Quality Management
- Vol. 24 (3) , 71-91
Chemical Characterization and Variations of Particulate Matter in a Coastal Residential Area Proximate to a Beach Sand Mine in the Ganjam District of Odisha, India
- 26 March 2015
- Published by Wiley in Environmental Quality Management
- Vol. 24 (3) , 71-91
Chemical Characterization and Variations of Particulate Matter in a Coastal Residential Area Proximate to a Beach Sand Mine in the Ganjam District of Odisha, India
- 7 November 2014
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 103 (4) , 321-328
Optimization of 210Po estimation in environmental samples using an improved deposition unit
Measurement of 210Po in environmental matrices is important due to its very high specific activity, present in every compartment of the environment due to a daughter product of uranium (238U), accumulative and highly toxic in nature. Conventional method for 210Po estimation is by auto-deposition onto both sides of a silver disc followed by alpha spectrometry of both the sides. A new deposition unit having the facility to hold the silver disc and magnetic stirring bar has designed and fabricated for 210Po estimation in which only one side is counted. In the conventional method, the total activity is distributed to the both sides of the silver disc and more counting time is required whereas in the improved deposition unit, only one side contain all the activity so that one time counting is required with better statistical significance. The same has been observed in spike recovery and water sample assessment. The tracer recovery in the conventional method was 72% – 88% and 70% – 85% whereas for the new deposition the recovery is 87% – 99% and 78% – 94% for spike recovery study and environmental samples, respectively. Certified tracers were analysed for the assurance of the reliability of the method and the results were in good agreement with the recommended value with a relative error 210Po at 3σ confidence level, 86400 s. counting time and 100 ml of water sample, taking the detector efficiency and chemical yield into consideration. The results obtained from both the methods were compared statistically. χ 2 test, repeatability parameters, relative bias measurement and linearity test was performed for both the methods. The % difference between the two methods in terms of linearity is 0.2%. From the χ 2 test it can be concluded that the measured data by two methods falls within 99% confidence interval. The modified deposition unit enhance the statistical significance, reduce the counting time, improved detection level, accuracy and precision and more suitable for determination of 210Po in environmental samples as the levels in various environmental matrices is very low and close to the method detection level.
- 7 November 2014
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 103 (4) , 321-328
Optimization of 210Po estimation in environmental samples using an improved deposition unit
Measurement of 210Po in environmental matrices is important due to its very high specific activity, present in every compartment of the environment due to a daughter product of uranium (238U), accumulative and highly toxic in nature. Conventional method for 210Po estimation is by auto-deposition onto both sides of a silver disc followed by alpha spectrometry of both the sides. A new deposition unit having the facility to hold the silver disc and magnetic stirring bar has designed and fabricated for 210Po estimation in which only one side is counted. In the conventional method, the total activity is distributed to the both sides of the silver disc and more counting time is required whereas in the improved deposition unit, only one side contain all the activity so that one time counting is required with better statistical significance. The same has been observed in spike recovery and water sample assessment. The tracer recovery in the conventional method was 72% – 88% and 70% – 85% whereas for the new deposition the recovery is 87% – 99% and 78% – 94% for spike recovery study and environmental samples, respectively. Certified tracers were analysed for the assurance of the reliability of the method and the results were in good agreement with the recommended value with a relative error 210Po at 3σ confidence level, 86400 s. counting time and 100 ml of water sample, taking the detector efficiency and chemical yield into consideration. The results obtained from both the methods were compared statistically. χ 2 test, repeatability parameters, relative bias measurement and linearity test was performed for both the methods. The % difference between the two methods in terms of linearity is 0.2%. From the χ 2 test it can be concluded that the measured data by two methods falls within 99% confidence interval. The modified deposition unit enhance the statistical significance, reduce the counting time, improved detection level, accuracy and precision and more suitable for determination of 210Po in environmental samples as the levels in various environmental matrices is very low and close to the method detection level.
- 21 March 2014
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 300 (3) , 903-910
Assessment of ingestion dose due to radioactivity in selected food matrices and water near Vizag, India
- 21 March 2014
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 300 (3) , 903-910
Assessment of ingestion dose due to radioactivity in selected food matrices and water near Vizag, India
- 16 March 2014
- Published by Taylor & Francis in Toxicological & Environmental Chemistry
- Vol. 96 (3) , 410-425
Source identification of particulate matter and associated intake of elements through inhalation in an industrial area of Odisha, India
- 16 March 2014
- Published by Taylor & Francis in Toxicological & Environmental Chemistry
- Vol. 96 (3) , 410-425
Source identification of particulate matter and associated intake of elements through inhalation in an industrial area of Odisha, India
- 7 February 2014
- Published by Taylor & Francis in Toxicological & Environmental Chemistry
- Vol. 96 (2) , 192-200
Concentrations of uranium in drinking water and cumulative, age-dependent radiation doses in four districts of Uttar Pradesh, India
- 7 February 2014
- Published by Taylor & Francis in Toxicological & Environmental Chemistry
- Vol. 96 (2) , 192-200
Concentrations of uranium in drinking water and cumulative, age-dependent radiation doses in four districts of Uttar Pradesh, India
- 25 April 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 157 (1) , 95-104
Distribution of norm and 137Cs in soils of the Visakhapatnam region, Eastern India, and associated radiation dose
The specific activity of naturally occurring radioactive materials and 137Cs in surface soils around the new Bhabha Atomic Research Centre site at Visakhapatnam region, Eastern India, has been determined using high-resolution gamma-ray spectrometry as part of a baseline radiological survey. Radiation hazard for the samples was assessed by radium equivalent activity (Raeq) and absorbed gamma dose rate (D). The mean absorbed gamma dose rate was found to be 104.9 nGy h−1. The average annual effective dose equivalent was found to be 0.13 mSv y−1.
- 25 April 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 157 (1) , 95-104
Distribution of norm and 137Cs in soils of the Visakhapatnam region, Eastern India, and associated radiation dose
The specific activity of naturally occurring radioactive materials and 137Cs in surface soils around the new Bhabha Atomic Research Centre site at Visakhapatnam region, Eastern India, has been determined using high-resolution gamma-ray spectrometry as part of a baseline radiological survey. Radiation hazard for the samples was assessed by radium equivalent activity (Raeq) and absorbed gamma dose rate (D). The mean absorbed gamma dose rate was found to be 104.9 nGy h−1. The average annual effective dose equivalent was found to be 0.13 mSv y−1.
- 22 March 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 155 (2) , 210-216
Age-dependent dose and health risk due to intake of uranium in drinking water from Jaduguda, India
Uranium is a heavy metal that is not only radiologically harmful but also a well-known nephrotoxic element. In this study, occurrence of uranium in drinking water samples from locations near the uranium mining site at Jaduguda, India, was studied by Laser-induced fluorimetry. Uranium concentrations range from 0.03 ± 0.01 to 11.6 ± 1.3 µg l−l, being well within the US Environmental Protection Agency drinking water limit of 30 μg l−1. The ingestion dose due to the presence of uranium in drinking water for various age groups varies from 0.03 to 28.3 μSv y−1. The excess lifetime cancer risk varies from 4.3×10−8 to 1.7×10−5 with an average value of 4.8×10−6, much less than the acceptable excess lifetime cancer risk of 10−3 for radiological risk. The chemical risk (hazard quotient) has an average value of 0.15 indicating that the water is safe for drinking.
- 22 March 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 155 (2) , 210-216
Age-dependent dose and health risk due to intake of uranium in drinking water from Jaduguda, India
Uranium is a heavy metal that is not only radiologically harmful but also a well-known nephrotoxic element. In this study, occurrence of uranium in drinking water samples from locations near the uranium mining site at Jaduguda, India, was studied by Laser-induced fluorimetry. Uranium concentrations range from 0.03 ± 0.01 to 11.6 ± 1.3 µg l−l, being well within the US Environmental Protection Agency drinking water limit of 30 μg l−1. The ingestion dose due to the presence of uranium in drinking water for various age groups varies from 0.03 to 28.3 μSv y−1. The excess lifetime cancer risk varies from 4.3×10−8 to 1.7×10−5 with an average value of 4.8×10−6, much less than the acceptable excess lifetime cancer risk of 10−3 for radiological risk. The chemical risk (hazard quotient) has an average value of 0.15 indicating that the water is safe for drinking.