H. John Crabtree
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
H. John Crabtree has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Alexander J. Stickel
University of Alberta
3 shared publicationsAlexey Atrazhev
University of Alberta
3 shared publicationsChristopher J. Backhouse
University of Alberta
3 shared publications- Christopher J. Backhouse
Department of Electrical and Computer Engineering, University of Alberta, Canada
3 shared publications Dammika P. Manage
University of Alberta
3 shared publications- Andreas Manz
KIST Europe, 66123 Saarbrücken, Germany
2 shared publications
Latest Publications
- 20 August 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (20) , 8689-8696
Determination of inorganic anions in oilfield water using capillary electrophoresis with indirect fluorescence detection
Analysis of high salinity oilfield water for anions presents challenges. Here we develop a capillary electrophoresis method using indirect fluorescence detection for simultaneous separation and determination of bromide, chloride, nitrate and sulfate. 8-Hydroxypyrene-1,3,6-trisulfonic acid (HPTS) is used as the fluorescent probe in the background electrolyte. High resolution (8.5) between chloride and sulfate is achieved using an acidic BGE (pH 2.0) under reversed polarity. This method is capable of detecting trace anions in high chloride samples (5 ppm Br− in 30 ppm Cl−, 1 ppm NO3 − in 400 ppm Cl−, 1.5 ppm SO4 2− in 1500 ppm Cl−). Linear calibration (R2 > 0.99) was achieved for sulfate over the range 1–20 ppm in 500 ppm chloride. Limits of detection (LOD) were 0.4 ppm for sulfate and 1.4 ppm for chloride. This method was applied to the determination of chloride and sulfate in high salinity oilfield water samples, with 9% RSD for chloride and 84% spike recovery for sulfate.
- 20 August 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (20) , 8689-8696
Determination of inorganic anions in oilfield water using capillary electrophoresis with indirect fluorescence detection
Analysis of high salinity oilfield water for anions presents challenges. Here we develop a capillary electrophoresis method using indirect fluorescence detection for simultaneous separation and determination of bromide, chloride, nitrate and sulfate. 8-Hydroxypyrene-1,3,6-trisulfonic acid (HPTS) is used as the fluorescent probe in the background electrolyte. High resolution (8.5) between chloride and sulfate is achieved using an acidic BGE (pH 2.0) under reversed polarity. This method is capable of detecting trace anions in high chloride samples (5 ppm Br− in 30 ppm Cl−, 1 ppm NO3 − in 400 ppm Cl−, 1.5 ppm SO4 2− in 1500 ppm Cl−). Linear calibration (R2 > 0.99) was achieved for sulfate over the range 1–20 ppm in 500 ppm chloride. Limits of detection (LOD) were 0.4 ppm for sulfate and 1.4 ppm for chloride. This method was applied to the determination of chloride and sulfate in high salinity oilfield water samples, with 9% RSD for chloride and 84% spike recovery for sulfate.
- 26 January 2015
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 95 (2) , 175-186
Determination of sulfate and chloride ions in highly saline oilfield water by capillary electrophoresis using bilayer-coated capillaries and indirect absorption detection
Analysis of highly saline oilfield waters for anions presents challenges. Traditional analytical techniques used for such analysis tend to suffer from both poor sensitivity and selectivity due to the high concentrations of salt present in the samples. A capillary electrophoresis method was developed for the simultaneous determination of chloride and sulfate anions which is relevant to the oilfield analysis industry and of economic value. Due to the extremely high concentrations of chloride in highly saline oilfield waters, it is difficult to achieve baseline electrophoretic separation necessary for accurate quantitation. By using a capillary with a noncovalently bound bilayer coating using Polybrene, a cationic polymer and sodium dodecyl sulfate (SDS), an anionic surfactant and a buffer consisting of 50 mM TRIS, 30 mM SDS, 5% methanol and 26 mM chromium trioxide (CrO3) at pH 6.7, baseline separation (Rs > 1.5) of chloride and sulfate was achieved. To mimic possible oilfield water samples, model water solutions of 5%, 10%, 15% and 20% chloride containing low ppm sulfate were prepared and successfully analysed using the method developed. In addition, the method was applied to determine chloride and sulfate anions in highly saline oilfield water samples. The accuracy of the method developed was verified by analysing NIST certified standards of chloride and sulfate. The results obtained for chloride and sulfate with the indirect CE-UV method were in close agreement (94–100% accuracy; <2.5% relative standard deviations) with those of the certified standard analysed by ion chromatography.
- 26 January 2015
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 95 (2) , 175-186
Determination of sulfate and chloride ions in highly saline oilfield water by capillary electrophoresis using bilayer-coated capillaries and indirect absorption detection
Analysis of highly saline oilfield waters for anions presents challenges. Traditional analytical techniques used for such analysis tend to suffer from both poor sensitivity and selectivity due to the high concentrations of salt present in the samples. A capillary electrophoresis method was developed for the simultaneous determination of chloride and sulfate anions which is relevant to the oilfield analysis industry and of economic value. Due to the extremely high concentrations of chloride in highly saline oilfield waters, it is difficult to achieve baseline electrophoretic separation necessary for accurate quantitation. By using a capillary with a noncovalently bound bilayer coating using Polybrene, a cationic polymer and sodium dodecyl sulfate (SDS), an anionic surfactant and a buffer consisting of 50 mM TRIS, 30 mM SDS, 5% methanol and 26 mM chromium trioxide (CrO3) at pH 6.7, baseline separation (Rs > 1.5) of chloride and sulfate was achieved. To mimic possible oilfield water samples, model water solutions of 5%, 10%, 15% and 20% chloride containing low ppm sulfate were prepared and successfully analysed using the method developed. In addition, the method was applied to determine chloride and sulfate anions in highly saline oilfield water samples. The accuracy of the method developed was verified by analysing NIST certified standards of chloride and sulfate. The results obtained for chloride and sulfate with the indirect CE-UV method were in close agreement (94–100% accuracy; <2.5% relative standard deviations) with those of the certified standard analysed by ion chromatography.
- 29 March 2012
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 13 (3) , 383-398
Inhibition of on-chip PCR using PDMS–glass hybrid microfluidic chips
- 29 March 2012
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 13 (3) , 383-398
Inhibition of on-chip PCR using PDMS–glass hybrid microfluidic chips
- 19 March 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (9) , 1664-1671
A miniaturized and integrated gel post platform for multiparameter PCR detection of herpes simplex viruses from raw genital swabs
Herpes simplex virus (HSV) is one of the most prevalent viruses, with acute and recurrent infections in humans. The current gold standard for the diagnosis of HSV is viral culture which takes 2–14 days and has low sensitivity. In contrast, DNA amplification by polymerase chain reaction (PCR) can be performed within 1–2 h. We here describe a multiparameter PCR assay to simultaneously detect HSV-1 and HSV-2 DNA templates, together with integrated positive and negative controls, with product detection by melting curve analysis (MCA), in an array of semi-solid polyacrylamide gel posts. Each gel post is 0.67 μL in volume, and polymerized with all the components required for PCR. Both PCR and MCA can currently be performed in one hour and 20 min. Unprocessed genital swabs collected in universal transport medium were directly added to the reagents before or after polymerization, diffusing from atop the gel posts. The gel post platform detects HSV templates in as little as 2.5 nL of raw sample. In this study, 45 genital swab specimens were tested blindly as a preliminary validation of this platform. The concordance of PCR on gel posts with conventional PCR was 91%. The primer sequestration method introduced here (wherein different primers are placed in different sets of posts) enables the simultaneous detection of multiple pathogens for the same sample, together with positive and negative controls, on a single chip. This platform accepts unprocessed samples and is readily adaptable to detection of multiple different pathogens or biomarkers for point-of-care diagnostics.
- 19 March 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (9) , 1664-1671
A miniaturized and integrated gel post platform for multiparameter PCR detection of herpes simplex viruses from raw genital swabs
Herpes simplex virus (HSV) is one of the most prevalent viruses, with acute and recurrent infections in humans. The current gold standard for the diagnosis of HSV is viral culture which takes 2–14 days and has low sensitivity. In contrast, DNA amplification by polymerase chain reaction (PCR) can be performed within 1–2 h. We here describe a multiparameter PCR assay to simultaneously detect HSV-1 and HSV-2 DNA templates, together with integrated positive and negative controls, with product detection by melting curve analysis (MCA), in an array of semi-solid polyacrylamide gel posts. Each gel post is 0.67 μL in volume, and polymerized with all the components required for PCR. Both PCR and MCA can currently be performed in one hour and 20 min. Unprocessed genital swabs collected in universal transport medium were directly added to the reagents before or after polymerization, diffusing from atop the gel posts. The gel post platform detects HSV templates in as little as 2.5 nL of raw sample. In this study, 45 genital swab specimens were tested blindly as a preliminary validation of this platform. The concordance of PCR on gel posts with conventional PCR was 91%. The primer sequestration method introduced here (wherein different primers are placed in different sets of posts) enables the simultaneous detection of multiple pathogens for the same sample, together with positive and negative controls, on a single chip. This platform accepts unprocessed samples and is readily adaptable to detection of multiple different pathogens or biomarkers for point-of-care diagnostics.
- 20 January 2012
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 22 (2)
Characterisation and comparison of microfluidic chips formed using abrasive jet micromachining and wet etching
- 20 January 2012
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 22 (2)
Characterisation and comparison of microfluidic chips formed using abrasive jet micromachining and wet etching
- 1 September 2010
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (19) , 8079-8087
In-Gel Technology for PCR Genotyping and Pathogen Detection
This work describes the use of polyacrylamide gel and PCR reagents photopolymerized in a mold to create an array of semisolid posts that serve as reaction vessels for parallel PCR amplification of an externally added template. DNA amplification occurred in a cylindrical, self-standing 9 × 9 array of gel posts each less than 1 μL in volume. Photopolymerization of the gel with an intercalating dye added prior to polymerization permitted acquisition of real-time PCR data and melting curve analysis data without the need for any type of post-PCR staining procedures. PCR was equally efficient and reproducible when template DNA was polymerized within the gel or when exogenous template was added atop precast gel posts. PCR amplification occurred with template from purified DNA or from raw urine of patients with BK viruria. Multiple primer sets can be utilized per gel post array with no detectable cross contamination. As few as 34 BK virus templates were consistently detected by PCR in an individual gel post. Amplification of HPA1 and FGFR2 genes in human genomic DNA (gDNA) required as little as 2−5 ng of gDNA template/gel post. The device prototype includes a Peltier element for PCR thermal cycling and a CCD camera to capture fluorescence for product detection. Our technology is amenable to integration in point of care microdevices.
- 1 September 2010
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (19) , 8079-8087
In-Gel Technology for PCR Genotyping and Pathogen Detection
This work describes the use of polyacrylamide gel and PCR reagents photopolymerized in a mold to create an array of semisolid posts that serve as reaction vessels for parallel PCR amplification of an externally added template. DNA amplification occurred in a cylindrical, self-standing 9 × 9 array of gel posts each less than 1 μL in volume. Photopolymerization of the gel with an intercalating dye added prior to polymerization permitted acquisition of real-time PCR data and melting curve analysis data without the need for any type of post-PCR staining procedures. PCR was equally efficient and reproducible when template DNA was polymerized within the gel or when exogenous template was added atop precast gel posts. PCR amplification occurred with template from purified DNA or from raw urine of patients with BK viruria. Multiple primer sets can be utilized per gel post array with no detectable cross contamination. As few as 34 BK virus templates were consistently detected by PCR in an individual gel post. Amplification of HPA1 and FGFR2 genes in human genomic DNA (gDNA) required as little as 2−5 ng of gDNA template/gel post. The device prototype includes a Peltier element for PCR thermal cycling and a CCD camera to capture fluorescence for product detection. Our technology is amenable to integration in point of care microdevices.
- 1 December 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (2) , 239-248
Continuous dielectrophoretic cell separation microfluidic device
We present a prototype microfluidic device developed for the continuous dielectrophoretic (DEP) fractionation and purification of sample suspensions of biological cells. The device integrates three fully functional and distinct units consisting of an injector, a fractionation region, and two outlets. In the sheath and sample injection ports, the cell sample are hydrodynamically focused into a stream of controlled width; in the DEP fractionation region, a specially shaped nonuniform (isomotive) electric field is synthesized and employed to facilitate the separation, and the sorted cells are then delivered to two sample collection ports. The microfluidic behavior of the injector region was simulated and then experimentally verified. The operation and performance of the device was evaluated using yeast cells as model biological particles. Issues relating to the fabrication and operation of the device are discussed in detail. Such a device takes a significant step towards an integrated lab-on-a-chip device, which could interface/integrate to a number of other on-chip components for the device to undertake the whole laboratory procedure.
- 1 December 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (2) , 239-248
Continuous dielectrophoretic cell separation microfluidic device
We present a prototype microfluidic device developed for the continuous dielectrophoretic (DEP) fractionation and purification of sample suspensions of biological cells. The device integrates three fully functional and distinct units consisting of an injector, a fractionation region, and two outlets. In the sheath and sample injection ports, the cell sample are hydrodynamically focused into a stream of controlled width; in the DEP fractionation region, a specially shaped nonuniform (isomotive) electric field is synthesized and employed to facilitate the separation, and the sorted cells are then delivered to two sample collection ports. The microfluidic behavior of the injector region was simulated and then experimentally verified. The operation and performance of the device was evaluated using yeast cells as model biological particles. Issues relating to the fabrication and operation of the device are discussed in detail. Such a device takes a significant step towards an integrated lab-on-a-chip device, which could interface/integrate to a number of other on-chip components for the device to undertake the whole laboratory procedure.
- 16 May 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (7) , 936-941
High fidelity, high yield production of microfluidic devices by hot embossing lithography: rheology and stiction
We discuss thermoforming of thermoplastic polymers for the hot-embossing lithographic (HEL) fabrication of microfluidic chips near equilibrium conditions that minimize elastic recoil for optimal motif replication. While HEL is often simplistically described as the transfer of micro- and nano-motifs into heat-softened thermoplastic materials, we describe our rational approach to selecting appropriate processing parameters.
- 16 May 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (7) , 936-941
High fidelity, high yield production of microfluidic devices by hot embossing lithography: rheology and stiction
We discuss thermoforming of thermoplastic polymers for the hot-embossing lithographic (HEL) fabrication of microfluidic chips near equilibrium conditions that minimize elastic recoil for optimal motif replication. While HEL is often simplistically described as the transfer of micro- and nano-motifs into heat-softened thermoplastic materials, we describe our rational approach to selecting appropriate processing parameters.
- 29 July 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (14) , 2692-2700
A rejuvenation method for poly(N,N‐dimethylacrylamide)‐coated glass microfluidic chips
As microfluidic chips come to integrate the higher levels of functionality required for the implementation of advanced bioanalytical protocols, a crucial factor is that of cost. Although glass chips provide advantages in multilayer integrations, their cost is far higher than that of polymer chips. However, a simple and effective rejuvenation protocol for glass microchips may enable higher levels of integration and functionality on glass microchips. Here we present a method to rejuvenate glass microchips that had been used for capillary electrophoresis to the extent that their performance was degraded. This degradation was due to one of the two mechanisms: (i) a deterioration of the polymer coating on the inner surface of the microchannel or (ii) an aging of the glass substrate. Using the method presented here, we have rejuvenated more than 50 such “aged” microchips. The performance of these microchips was fully restored after the rejuvenation and lasted for hundreds of DNA separation runs. Our experiments indicate that the loss of resolution in microchip separations was not associated with glass aging, but was due to the degradation of the polymer coating on the inner surface of microchannels. This suggests that it is possible to extend the microchip lifetime “forever” using the rejuvenation protocol and that the exploration of higher levels of integration and functionality on glass microchips (or of hybrid structures involving materials capable of withstanding the reagents and elevated temperatures used) is feasible.
- 29 July 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (14) , 2692-2700
A rejuvenation method for poly(N,N‐dimethylacrylamide)‐coated glass microfluidic chips
As microfluidic chips come to integrate the higher levels of functionality required for the implementation of advanced bioanalytical protocols, a crucial factor is that of cost. Although glass chips provide advantages in multilayer integrations, their cost is far higher than that of polymer chips. However, a simple and effective rejuvenation protocol for glass microchips may enable higher levels of integration and functionality on glass microchips. Here we present a method to rejuvenate glass microchips that had been used for capillary electrophoresis to the extent that their performance was degraded. This degradation was due to one of the two mechanisms: (i) a deterioration of the polymer coating on the inner surface of the microchannel or (ii) an aging of the glass substrate. Using the method presented here, we have rejuvenated more than 50 such “aged” microchips. The performance of these microchips was fully restored after the rejuvenation and lasted for hundreds of DNA separation runs. Our experiments indicate that the loss of resolution in microchip separations was not associated with glass aging, but was due to the degradation of the polymer coating on the inner surface of microchannels. This suggests that it is possible to extend the microchip lifetime “forever” using the rejuvenation protocol and that the exploration of higher levels of integration and functionality on glass microchips (or of hybrid structures involving materials capable of withstanding the reagents and elevated temperatures used) is feasible.
- 1 June 2005
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 5 (6) , 864-868
Transition of MEMS Technology to Nanofabrication
The transition of MEMS technology to nano fabrication is a solution to the growing demand for smaller and high-density feature sizes in the nanometer scale. Nanoimprint lithography (NIL) techniques for fabricating micro- and nano-features are discussed including hot embossing lithography (HEL), UV Molding (UVM) and micro contact printing (CP). Recent results in micro and nanopattern transfer are presented where features ranged from <100 nm to several centimeters. We also present a comparative study between standard glass microfluidic chips and their HEL counterparts by metrology. Hot-embossed microfluidic chips are shown to be faithful replicates of their parent stamps. NIL is presented as a promising avenue for low-cost, high throughput micro and nano-device fabrication.
- 1 June 2005
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 5 (6) , 864-868
Transition of MEMS Technology to Nanofabrication
The transition of MEMS technology to nano fabrication is a solution to the growing demand for smaller and high-density feature sizes in the nanometer scale. Nanoimprint lithography (NIL) techniques for fabricating micro- and nano-features are discussed including hot embossing lithography (HEL), UV Molding (UVM) and micro contact printing (CP). Recent results in micro and nanopattern transfer are presented where features ranged from <100 nm to several centimeters. We also present a comparative study between standard glass microfluidic chips and their HEL counterparts by metrology. Hot-embossed microfluidic chips are shown to be faithful replicates of their parent stamps. NIL is presented as a promising avenue for low-cost, high throughput micro and nano-device fabrication.