ZYZisheng Yao

Zisheng Yao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zisheng Yao has a total of 136 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    4D reconstruction of alumina laser melt pools at 25 kHz via operando X-ray multi-projection imaging

    by Lars Witte, Eliot Jermann, Zhe Hu, Zisheng Yao, Eleni Myrto Asimakopoulou, Julia Katharina Rogalinski, Yuhe Zhang, Kim Nygård, Malgorzata G. Makowska, Markus Bambach, et al.

    Advancing additive manufacturing, e.g., laser powder-bed fusion (LPBF), requires resolving rapid processes such as melt-pool dynamics and keyhole evolution in 4D (3D + time). Operando X-ray tomography is a state-of-the-art approach for 4D characterization, but its temporal resolution is fundamentally constrained by the sample rotation speed, limiting achievable 4D imaging rates and preventing the resolution of these fast phenomena. Here we present rotation-enabled X-ray Multi-Projection Imaging (rotation-XMPI), which captures three angularly resolved projections per time step and thereby decouples temporal resolution from the sample rotation speed. Combined with a self-supervised deep-learning reconstruction framework for multi-angle inputs, rotation-XMPI enables high-fidelity 4D imaging at unprecedented speed. We demonstrate the approach in an operando alumina laser-remelting experiment at MAX IV using three beamlets combined with 25 Hz sample rotation. Rotation-XMPI resolves melt-pool morphology and keyhole evolution; in contrast, conventional and limited-angle tomography remain rotation-limited, and motion blur prevents resolving these dynamics. Overall, rotation-XMPI delivers a 250-fold increase relative to state-of-the-art melt-pool imaging, effectively achieving 25,000 reconstructed volumes per second. This method establishes a practical route to scalable ultrafast 4D imaging for additive manufacturing and other materials processes.

  • Open Access

    Opportunities and challenges of megahertz X-ray synchrotron radiography for in situ materials science applications due to high dose rate

    by Elise Van Vlierberghe, Julia Katharina Rogalinski, Jeroen Soete, Mahoor Mehdikhani, Johan Vanhulst, Zisheng Yao, Eleni Myrto Asimakopoulou, Kim Nygård, Christian Breite, Pablo Villanueva Perez, et al.

  • Open Access

    Synchrotron X-ray multi-projection imaging (XMPI) for high-resolution 4D characterization of multiphase flows

    by Tomas Rosén, Zisheng Yao, Jonas Tejbo, Patrick Wegele, Julia K. Rogalinski, Frida Nilsson, Kannara Mom, Zhe Hu, Samuel A. McDonald, Kim Nygård, et al.

  • Open Access

    Opportunities and Challenges of Megahertz X-ray Synchrotron Radiography for in Situ Materials Science Applications Due to High Dose Rate

    by Elise Van Vlierberghe, Julia Katharina Rogalinski, Jeroen Soete, Mahoor Mehdikhani, Johan Vanhulst, Zisheng Yao, Eleni Myrto Asimakopoulou, Kim Nygård, Christian Breite, Pablo Villanueva Perez, et al.

    Characterising ultra-high-speed dynamic events in the bulk of the material requires high-frame-rate imaging, combined with X-rays capable of penetrating the material. Megahertz radiography with synchrotron radiation was explored, showing strong potential for capturing dynamic damage events. In situ tensile tests were performed on fibre-reinforced polymer composites to image transverse crack dynamics. Challenges of this experimental technique were highlighted and complemented with plausible strategies. The first challenge stemmed from the limited buffer capacity of the high-speed camera, which was addressed by designing two triggering strategies based on electrical conductivity and load drops. The second challenge concerned dose effects due to the high photon flux required for ultra-high-speed radiography, which led to a degradation of the specimen by thermal effects. Dose calculations were performed, and a heat transfer model was developed to quantify the dose rate effect. Increasing beam energy and enhancing cooling were proposed to mitigate the heat load, providing actionable insights for future ultra-high-speed radiography experiments across a wide range of applications.

  • Open Access

    Time-resolved 3D imaging opportunities with XMPI at ForMAX

    by Julia Katharina Rogalinski, Zisheng Yao, Yuhe Zhang, Zhe Hu, Korneliya Gordeyeva, Tomas Rosén, Daniel Söderberg, Andrea Mazzolari, Jackson da Silva, Vahid Haghighat, et al.

    X-rays are commonly used in imaging experiments due to their penetration power, which enables non-destructive resolution of internal structures in samples that are opaque to visible light. Time-resolved X-ray tomography is the state-of-the-art method for obtaining volumetric 4D (3D + time) information by rotating the sample and acquiring projections from different angular viewpoints over time. This method enables studies to address a plethora of research questions across various scientific disciplines. However, it has several limitations, such as incompatibility with single-shot experiments, challenges in rotating complex sample environments that restrict the achievable rotation speed or range, and the introduction of centrifugal forces that can affect the sample's dynamics. These limitations can hinder and even preclude the study of certain dynamics. Here, we present an implementation of an alternative approach, X-ray multi-projection imaging (XMPI), which eliminates the need for sample rotation. Instead, the direct incident X-ray beam is split into beamlets using beam splitting X-ray optics. These beamlets intersect at the sample position from different angular viewpoints, allowing multiple projections to be acquired simultaneously. We commissioned this setup at the ForMAX beamline at MAX IV, the first operational diffraction-limited storage ring. We present projections acquired from two different sample systems – fibers under mechanical load and particle suspension in multiphase flow – with distinct spatial and temporal resolution requirements. We demonstrate the capabilities of the ForMAX XMPI setup using the detector's full analog-to-digital converter range for the relevant sample-driven spatiotemporal resolutions: (i) at least 12.5 kHz frame rates with 4 µm pixel sizes (fibers) and (ii) 40 Hz acquisitions with 1.3 µm pixel sizes (multiphase flows). The presented setup and results form the basis for a permanent XMPI endstation at ForMAX, offering flexibility to adapt to the spatiotemporal requirements of the studied dynamics.


  • Open Access

    Physics-informed 4D x-ray image reconstruction from ultra-sparse spatiotemporal data

    by Zisheng Yao, Yuhe Zhang, Zhe Hu, Robert Klöfkorn, Tobias Ritschel, Pablo Villanueva-Perez

    The unprecedented x-ray flux density provided by modern x-ray sources offers new spatiotemporal possibilities for x-ray imaging of fast dynamic processes. Approaches to exploit such possibilities often result in either (i) a limited number of projections or spatial information due to limited scanning speed, as in time-resolved tomography, or (ii) a limited number of time points, as in stroboscopic imaging, making the reconstruction problem ill-posed and unlikely to be solved by classical reconstruction approaches. Four-dimensional (4D) reconstruction from such data requires sample priors, which can be included via deep learning (DL). State-of-the-art 4D reconstruction methods for x-ray imaging combine the power of artificial intelligence and the physics of x-ray propagation to tackle the challenge of sparse views. However, most approaches do not constrain the physics of the studied process, i.e. a full physical model. Here we present 4D physics-informed optimized neural implicit x-ray imaging, a novel physics-informed 4D x-ray image reconstruction method combining the full physical model and a state-of-the-art DL-based reconstruction method for 4D x-ray imaging from sparse views. We demonstrate and evaluate the potential of our approach by retrieving 4D information from ultra-sparse spatiotemporal acquisitions of simulated binary droplet collisions, a relevant fluid dynamic process. We envision that this work will open new spatiotemporal possibilities for various 4D x-ray imaging modalities, such as time-resolved x-ray tomography and more novel sparse acquisition approaches like x-ray multi-projection imaging, which will pave the way for investigations of various rapid 4D dynamics, such as fluid dynamics and composite testing.


  • Open Access

    4D-ONIX for reconstructing 3D movies from sparse X-ray projections via deep learning

    by Yuhe Zhang, Zisheng Yao, Robert Klöfkorn, Tobias Ritschel, Pablo Villanueva-Perez

    The X-ray flux from X-ray free-electron lasers and storage rings enables new spatiotemporal opportunities for studying in-situ and operando dynamics, even with single pulses. X-ray multi-projection imaging is a technique that provides volumetric information using single pulses while avoiding the centrifugal forces induced by conventional time-resolved 3D methods like time-resolved tomography, and can acquire 3D movies (4D) at least three orders of magnitude faster than existing techniques. However, reconstructing 4D information from highly sparse projections remains a challenge for current algorithms. Here we present 4D-ONIX, a deep-learning-based approach that reconstructs 3D movies from an extremely limited number of projections. It combines the computational physical model of X-ray interaction with matter and state-of-the-art deep learning methods. We demonstrate its ability to reconstruct high-quality 4D by generalizing over multiple experiments with only two to three projections per timestamp on simulations of water droplet collisions and experimental data of additive manufacturing. Our results demonstrate 4D-ONIX as an enabling tool for 4D analysis, offering high-quality image reconstruction for fast dynamics three orders of magnitude faster than tomography.


  • Open Access

    Development of crystal optics for X-ray multi-projection imaging for synchrotron and XFEL sources

    by Valerio Bellucci, Sarlota Birnsteinova, Tokushi Sato, Romain Letrun, Jayanath C. P. Koliyadu, Chan Kim, Gabriele Giovanetti, Carsten Deiter, Liubov Samoylova, Ilia Petrov, et al.

    X-ray multi-projection imaging (XMPI) is an emerging experimental technique for the acquisition of rotation-free, time-resolved, volumetric information on stochastic processes. The technique is developed for high-brilliance light-source facilities, aiming to address known limitations of state-of-the-art imaging methods in the acquisition of 4D sample information, linked to their need for sample rotation. XMPI relies on a beam-splitting scheme, that illuminates a sample from multiple, angularly spaced viewpoints, and employs fast, indirect, X-ray imaging detectors for the collection of the data. This approach enables studies of previously inaccessible phenomena of industrial and societal relevance such as fractures in solids, propagation of shock waves, laser-based 3D printing, or even fast processes in the biological domain. In this work, we discuss in detail the beam-splitting scheme of XMPI. More specifically, we explore the relevant properties of X-ray splitter optics for their use in XMPI schemes, both at synchrotron insertion devices and XFEL facilities. Furthermore, we describe two distinct XMPI schemes, designed to faciliate large samples and complex sample environments. Finally, we present experimental proof of the feasibility of MHz-rate XMPI at the European XFEL. This detailed overview aims to state the challenges and the potential of XMPI and act as a stepping stone for future development of the technique.


  • Open Access

    New opportunities for time-resolved imaging using diffraction-limited storage rings

    by Zisheng Yao, Julia Rogalinski, Eleni Myrto Asimakopoulou, Yuhe Zhang, Korneliya Gordeyeva, Zhaleh Atoufi, Hanna Dierks, Samuel McDonald, Stephen Hall, Jesper Wallentin, et al.

    The advent of diffraction-limited storage rings (DLSRs) has boosted the brilliance or coherent flux by one to two orders of magnitude with respect to the previous generation. One consequence of this brilliance enhancement is an increase in the flux density or number of photons per unit of area and time, which opens new possibilities for the spatiotemporal resolution of X-ray imaging techniques. This paper studies the time-resolved microscopy capabilities of such facilities by benchmarking the ForMAX beamline at the MAX IV storage ring. It is demonstrated that this enhanced flux density using a single harmonic of the source allows micrometre-resolution time-resolved imaging at 2000 tomograms per second and 1.1 MHz 2D acquisition rates using the full dynamic range of the detector system.


  • Open Access

    ForMAX – a beamline for multiscale and multimodal structural characterization of hierarchical materials

    by K. Nygård, S. A. McDonald, J B González, J.B., V. Haghighat, C. Appel, E. Larsson, R. Ghanbari, M. Viljanen, J. Silva, et al.

    The ForMAX beamline at the MAX IV Laboratory provides multiscale and multimodal structural characterization of hierarchical materials in the nanometre to millimetre range by combining small- and wide-angle X-ray scattering with full-field microtomography. The modular design of the beamline is optimized for easy switching between different experimental modalities. The beamline has a special focus on the development of novel fibrous materials from forest resources, but it is also well suited for studies within, for example, food science and biomedical research.