Mikael Philippe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mikael Philippe has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Jasmin Raymond
Centre Eau Terre Environnement, Institut National de la Recherche Scientifique, Quebec, QC G1K 9A9, Canada
2 shared publications Michel Bernier
2 shared publicationsAlexandre Vrain
BRGM (France)
1 shared publicationDaniela Blessent
1 shared publication- Daniela Blessent
Programa de Ingeniería Ambiental, Universidad de Medellín, Medellín, Colombia
1 shared publication Dominique Marchio
1 shared publication
Latest Publications
- 1 October 2019
- Published by Elsevier in Physics and Chemistry of the Earth, Parts A/B/C
- Vol. 113, 22-30
Terrestrial heat flow evaluation from thermal response tests combined with temperature profiling
- 1 October 2019
- Published by Elsevier in Physics and Chemistry of the Earth, Parts A/B/C
- Vol. 113, 22-30
Terrestrial heat flow evaluation from thermal response tests combined with temperature profiling
- Open Access
Distributed Thermal Response Tests Using a Heating Cable and Fiber Optic Temperature Sensing
Thermal response tests are used to assess the subsurface thermal conductivity to design ground-coupled heat pump systems. Conventional tests are cumbersome and require a source of high power to heat water circulating in a pilot ground heat exchanger. An alternative test method using heating cable was verified in the field as an option to conduct this heat injection experiment with a low power source and a compact equipment. Two thermal response tests using heating cable sections and a continuous heating cable were performed in two experimental heat exchangers on different sites in Canada and France. The temperature evolution during the tests was monitored using submersible sensors and fiber optic distributed temperature sensing. Free convection that can occur in the pipe of the heat exchanger was evaluated using the Rayleigh number stability criterion. The finite and infinite line source equations were used to reproduce temperature variations along the heating cable sections and continuous heating cable, respectively. The thermal conductivity profile of each site was inferred and the uncertainly of the test was evaluated. A mean thermal conductivity 15% higher than that revealed with the conventional test was estimated with heating cable sections. The thermal conductivity evaluated using the continuous heating cable corresponds to the value estimated during the conventional test. The average uncertainly associated with the heating cable section test was 15.18%, while an uncertainty of 2.14% was estimated for the test with the continuous heating cable. According to the Rayleigh number stability criterion, significant free convection can occur during the heat injection period when heating cable sections are used. The continuous heating cable with a low power source is a promising method to perform thermal response tests and further tests could be carried out in deep boreholes to verify its applicability.
Open AccessDistributed Thermal Response Tests Using a Heating Cable and Fiber Optic Temperature Sensing
Thermal response tests are used to assess the subsurface thermal conductivity to design ground-coupled heat pump systems. Conventional tests are cumbersome and require a source of high power to heat water circulating in a pilot ground heat exchanger. An alternative test method using heating cable was verified in the field as an option to conduct this heat injection experiment with a low power source and a compact equipment. Two thermal response tests using heating cable sections and a continuous heating cable were performed in two experimental heat exchangers on different sites in Canada and France. The temperature evolution during the tests was monitored using submersible sensors and fiber optic distributed temperature sensing. Free convection that can occur in the pipe of the heat exchanger was evaluated using the Rayleigh number stability criterion. The finite and infinite line source equations were used to reproduce temperature variations along the heating cable sections and continuous heating cable, respectively. The thermal conductivity profile of each site was inferred and the uncertainly of the test was evaluated. A mean thermal conductivity 15% higher than that revealed with the conventional test was estimated with heating cable sections. The thermal conductivity evaluated using the continuous heating cable corresponds to the value estimated during the conventional test. The average uncertainly associated with the heating cable section test was 15.18%, while an uncertainty of 2.14% was estimated for the test with the continuous heating cable. According to the Rayleigh number stability criterion, significant free convection can occur during the heat injection period when heating cable sections are used. The continuous heating cable with a low power source is a promising method to perform thermal response tests and further tests could be carried out in deep boreholes to verify its applicability.
- 1 December 2017
- Published by Elsevier in Renewable Energy
- Vol. 113, 1168-1181
Experimental thermal performance analysis of ground heat exchangers for space heating and cooling applications
- 1 December 2017
- Published by Elsevier in Renewable Energy
- Vol. 113, 1168-1181
Experimental thermal performance analysis of ground heat exchangers for space heating and cooling applications
- 1 April 2017
- Published by Elsevier in Renewable Energy
- Vol. 103, 295-307
A simple heat and moisture transfer model to predict ground temperature for shallow ground heat exchangers
- 1 April 2017
- Published by Elsevier in Renewable Energy
- Vol. 103, 295-307
A simple heat and moisture transfer model to predict ground temperature for shallow ground heat exchangers
- 1 May 2016
- Published by Elsevier in Journal of Applied Geophysics
- Vol. 128, 115-122
Electrical and thermal behavior of unsaturated soils: experimental results
- 1 May 2016
- Published by Elsevier in Journal of Applied Geophysics
- Vol. 128, 115-122
Electrical and thermal behavior of unsaturated soils: experimental results
- 8 September 2010
- Published by SPIE-Intl Soc Optical Eng
- p. 76533P-76533P-4
Raman distributed temperature sensing in underground geoexchange system
Underground heat exchangers are instrumented by eight multimode optical fiber cables connected to a distributed temperature sensing (DTS) Raman system which provides real time temperature monitoring, versus operational conditions of the installation. A user-friendly Labviewî software has been developed, allowing the configuration of the full installation, the signal processing of raw DTS data and storage, as well as the visualization of any temperature profile, on request. Preliminary temperature profiles are very promising. This platform will allow R&D about geothermal exchanges, will provide a full scale bench to characterize new equipments, and will encourage professionals to develop this renewable energy sector.
- 8 September 2010
- Published by SPIE-Intl Soc Optical Eng
- p. 76533P-76533P-4
Raman distributed temperature sensing in underground geoexchange system
Underground heat exchangers are instrumented by eight multimode optical fiber cables connected to a distributed temperature sensing (DTS) Raman system which provides real time temperature monitoring, versus operational conditions of the installation. A user-friendly Labviewî software has been developed, allowing the configuration of the full installation, the signal processing of raw DTS data and storage, as well as the visualization of any temperature profile, on request. Preliminary temperature profiles are very promising. This platform will allow R&D about geothermal exchanges, will provide a full scale bench to characterize new equipments, and will encourage professionals to develop this renewable energy sector.
- 1 December 2009
- Published by Elsevier in Geothermics
- Vol. 38 (4) , 407-413
Validity ranges of three analytical solutions to heat transfer in the vicinity of single boreholes
- 1 December 2009
- Published by Elsevier in Geothermics
- Vol. 38 (4) , 407-413
Validity ranges of three analytical solutions to heat transfer in the vicinity of single boreholes