Megan Ogle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Megan Ogle has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Christopher R. Dennison
Biomedical Instrumentation Lab, Department of Mechanical Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada
1 shared publication - Gabriella Wynn
Biomedical Instrumentation Lab, Mechanical Engineering, University of Alberta, Edmonton, Canada
1 shared publication - Jason P. Carey
University of Alberta
1 shared publication - Julia Shore
Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
1 shared publication - Samantha R. MacGillivray
Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
1 shared publication
Latest Publications
- 17 May 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (10) , 2957-2972
Repeatability and Biofidelity of a Physical Surrogate Neck Model Fit to a Hybrid III Head
In helmet impact testing, parameters including acceleration and velocity are measured using instrumented head-neck models that are meant to be mechanically realistic (i.e. biofidelic) stand-ins, or surrogates, for humans. Currently available models of the human neck are designed primarily for application in automotive crash testing, and their applicability in assessment of helmets is often questioned. The object of the present work is to document the mechanical design, repeatability, and biofidelity in low speed impact of a new neck model that we apply with a Hybrid III head. Focusing on Hybrid III head kinematics measured during impacts at 2 to 6 m/s, the co-efficient of variance of repeated measures of kinematics was generally less than 10%. Differences in kinematics between identical copies of the neck was less than 20% when tested with helmets, and less than 7% when the head was not helmeted. In parallel testing using a Hybrid III head-neck, the co-efficient of variance in repeated measures was less than 4% and the kinematics significantly differed from those measured using the new neck. CORAplus scores for the new neck were approximately 0.70 when compared against data for human subjects with passive neck muscles experiencing impact at 2 m/s.
- 17 May 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (10) , 2957-2972
Repeatability and Biofidelity of a Physical Surrogate Neck Model Fit to a Hybrid III Head
In helmet impact testing, parameters including acceleration and velocity are measured using instrumented head-neck models that are meant to be mechanically realistic (i.e. biofidelic) stand-ins, or surrogates, for humans. Currently available models of the human neck are designed primarily for application in automotive crash testing, and their applicability in assessment of helmets is often questioned. The object of the present work is to document the mechanical design, repeatability, and biofidelity in low speed impact of a new neck model that we apply with a Hybrid III head. Focusing on Hybrid III head kinematics measured during impacts at 2 to 6 m/s, the co-efficient of variance of repeated measures of kinematics was generally less than 10%. Differences in kinematics between identical copies of the neck was less than 20% when tested with helmets, and less than 7% when the head was not helmeted. In parallel testing using a Hybrid III head-neck, the co-efficient of variance in repeated measures was less than 4% and the kinematics significantly differed from those measured using the new neck. CORAplus scores for the new neck were approximately 0.70 when compared against data for human subjects with passive neck muscles experiencing impact at 2 m/s.