Maria Cecilia Queiroga Bazetto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Maria Cecilia Queiroga Bazetto has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
A. Pavani Filho
Department of Microsystems, Center for Information Technology Renato Archer - CTI, Campinas - SP, Brazil
2 shared publicationsA. V. U. Braga
Department of Microsystems, Center for Information Technology Renato Archer - CTI, Campinas - SP, Brazil
2 shared publicationsO. V. Balachova
Department of Microsystems, Center for Information Technology Renato Archer - CTI, Campinas - SP, Brazil
2 shared publicationsS. M. Balashov
Department of Microsystems, Center for Information Technology Renato Archer - CTI, Campinas - SP, Brazil
2 shared publications- Ana Amelia Machado
Instituto de Física “Gleb Wataghin”, Universidade Estadual de Campinas (UNICAMP)
1 shared publication - Ana Paula Aguiar de Mendonça
Institute of Physics Gleb Wataghin, Universidade Estadual de Campinas (Unicamp), Campinas, 13083-859, SP, Brazil
1 shared publication
Latest Publications
- 1 November 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (11) , 116012
Physics-informed generative adversarial networks applied to dichroic filters’ properties regression
Optical dichroic filters are key components of light detectors, and simulation is a desirable tool in detectors’ research and development (R&D). Simulations must address the nuances of light–matter interactions to provide a realistic representation of the detector’s performance. Accessing this information requires experimental data and precise measurements of the optical response under various conditions. While first-principles simulations are feasible, they are computationally costly and struggle to capture imperfections of real devices. To address this, we present the use of machine learning employing a conditional physics-informed generative adversarial network (CPIGAN) to simulate the optical transmittance of dichroic filters. Training on measured and simulated data enables the prediction of the filter’s behavior, capturing deviations between experiment and simulation, thereby shifting the bulk of the computational effort to training. Through training on datasets with varying numbers of experimental curves, we demonstrated that employing an optimized CPIGAN architecture with physics-informed loss terms enables the generation of realistic synthetic transmittance curves, even in scenarios with limited experimental data. We demonstrated good training results through a trade-off between properly selecting the experimental representative samples and robust hyperparameter optimization. We foresee that the plasticity of the CPIGAN model will be essential for handling diverse filter designs, enabling reliable, effective, and precise ML-assisted simulations.
- 1 November 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (11) , 116012
Physics-informed generative adversarial networks applied to dichroic filters’ properties regression
Optical dichroic filters are key components of light detectors, and simulation is a desirable tool in detectors’ research and development (R&D). Simulations must address the nuances of light–matter interactions to provide a realistic representation of the detector’s performance. Accessing this information requires experimental data and precise measurements of the optical response under various conditions. While first-principles simulations are feasible, they are computationally costly and struggle to capture imperfections of real devices. To address this, we present the use of machine learning employing a conditional physics-informed generative adversarial network (CPIGAN) to simulate the optical transmittance of dichroic filters. Training on measured and simulated data enables the prediction of the filter’s behavior, capturing deviations between experiment and simulation, thereby shifting the bulk of the computational effort to training. Through training on datasets with varying numbers of experimental curves, we demonstrated that employing an optimized CPIGAN architecture with physics-informed loss terms enables the generation of realistic synthetic transmittance curves, even in scenarios with limited experimental data. We demonstrated good training results through a trade-off between properly selecting the experimental representative samples and robust hyperparameter optimization. We foresee that the plasticity of the CPIGAN model will be essential for handling diverse filter designs, enabling reliable, effective, and precise ML-assisted simulations.
- Open Access
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , C05009
Production and characterization of veto Photon-Detection Units for the DarkSide-20k experiment
The DarkSide-20k (DS-20k) experiment, currently under construction at the Gran Sasso National Laboratory (LNGS), represents a significant advancement in the field of direct Dark Matter (DM) detection. Utilizing a dual-phase Liquid Argon Time Projection Chamber (LArTPC) DS-20k is designed to extend the sensitivity limits in the search for Weakly Interacting Massive Particles (WIMPs), a leading DM candidate. A crucial component of the experiment is the active veto system, which acts as a shield against external and instrumental background sources, minimizing background and enhancing accuracy of DM detection. The system features innovative near-UV cryogenic Silicon PhotoMultipliers (SiPMs) for light readout. Universities and research institutes in the UK and Poland are responsible for producing and testing the veto Photon-Detection Units (vPDUs) that will be fitted on the Inner and Outer Veto. This paper presents the status of the production and characterization of the vPDUs, along with the quality assurance and quality control (QA/QC) procedures implemented to ensure the reliability and efficiency of the photon-detection systems.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , C05009
Open AccessProduction and characterization of veto Photon-Detection Units for the DarkSide-20k experiment
The DarkSide-20k (DS-20k) experiment, currently under construction at the Gran Sasso National Laboratory (LNGS), represents a significant advancement in the field of direct Dark Matter (DM) detection. Utilizing a dual-phase Liquid Argon Time Projection Chamber (LArTPC) DS-20k is designed to extend the sensitivity limits in the search for Weakly Interacting Massive Particles (WIMPs), a leading DM candidate. A crucial component of the experiment is the active veto system, which acts as a shield against external and instrumental background sources, minimizing background and enhancing accuracy of DM detection. The system features innovative near-UV cryogenic Silicon PhotoMultipliers (SiPMs) for light readout. Universities and research institutes in the UK and Poland are responsible for producing and testing the veto Photon-Detection Units (vPDUs) that will be fitted on the Inner and Outer Veto. This paper presents the status of the production and characterization of the vPDUs, along with the quality assurance and quality control (QA/QC) procedures implemented to ensure the reliability and efficiency of the photon-detection systems.
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , C05048
Adherence of p-Terphenyl (PTP) film on the dichroic filter used for the X-ARAPUCA device
The adherence of the p-Terphenyl film to the substrate in the X-ARAPUCA dichroic filter is directly correlated with the long-term efficiency and durability of this device. This study presents the results of different cleaning methods established to analyze their contributions to the film's adherence to the substrate. The samples underwent analysis of their crystalline and morphological structure using XRD and AFM techniques. Three distinct techniques were employed in the adherence tests: ultrasonic bath, scratch test, and cryogenic immersion method with turbulence, as these devices will be submerged in liquid argon in the DUNE experiment. Results suggest that the deposited PTP layer exhibits a monoclinic crystalline structure, with topography revealing percolated planar grains and roughness ranging from 13 nm to 18 nm. The various adherence techniques employed yielded consistent results, highlighting the standard cleaning process involving Soap + H2O + N2 + Kiln as the preferred method.
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , C05048
Adherence of p-Terphenyl (PTP) film on the dichroic filter used for the X-ARAPUCA device
The adherence of the p-Terphenyl film to the substrate in the X-ARAPUCA dichroic filter is directly correlated with the long-term efficiency and durability of this device. This study presents the results of different cleaning methods established to analyze their contributions to the film's adherence to the substrate. The samples underwent analysis of their crystalline and morphological structure using XRD and AFM techniques. Three distinct techniques were employed in the adherence tests: ultrasonic bath, scratch test, and cryogenic immersion method with turbulence, as these devices will be submerged in liquid argon in the DUNE experiment. Results suggest that the deposited PTP layer exhibits a monoclinic crystalline structure, with topography revealing percolated planar grains and roughness ranging from 13 nm to 18 nm. The various adherence techniques employed yielded consistent results, highlighting the standard cleaning process involving Soap + H2O + N2 + Kiln as the preferred method.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Blade Coating System for Organic Electronics
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Blade Coating System for Organic Electronics
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
The optimized SAW humidity sensor with nanofilms of graphene oxide
Graphene oxide (GO) thin films with partial surface coating were deposited onto the surface of 160 MHz quartz SAW delay lines by SAW atomization of submicroliter droplets of GO aqueous dispersions. The delay lines were used as sensitive elements of the SAW relative humidity (RH) sensors for monitoring the process of saturation of vapor pressure of water in an enclosed volume. To explain the RH time dependence, we suggest a model, which takes into account two processes: fast adsorption of water molecules by the surface of GO, described by the first order kinetic equation, and slow volumetric adsorption, described by linear kinetic equation. The parameters of kinetic equations of the saturation process were estimated experimentally for the coatings obtained by different number of atomizations and for eleven different RH standards.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
The optimized SAW humidity sensor with nanofilms of graphene oxide
Graphene oxide (GO) thin films with partial surface coating were deposited onto the surface of 160 MHz quartz SAW delay lines by SAW atomization of submicroliter droplets of GO aqueous dispersions. The delay lines were used as sensitive elements of the SAW relative humidity (RH) sensors for monitoring the process of saturation of vapor pressure of water in an enclosed volume. To explain the RH time dependence, we suggest a model, which takes into account two processes: fast adsorption of water molecules by the surface of GO, described by the first order kinetic equation, and slow volumetric adsorption, described by linear kinetic equation. The parameters of kinetic equations of the saturation process were estimated experimentally for the coatings obtained by different number of atomizations and for eleven different RH standards.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Kinetic characteristics of the SAW humidity sensor partially coated with graphene oxide thin film
Atomization of one or two microliter droplets of aqueous dispersion of graphene oxide (GO) by the surface acoustic wave (SAW) atomizer was used to deposit GO sensitive films of 15-30-nm thickness onto the surface of the SAW humidity sensor. Sensitivity of the sensors with these films as sensitive elements was calibrated over a wide range of humidity using a special procedure of preparation of standards, and adsorption kinetic curves for this process were obtained. The first-order rate kinetic equation with special additional linear term was shown to be adequate for modeling the kinetics of water adsorption onto the GO thin film. All parameters of this equation were calculated from least-squares fitting of experimental data. It was shown that the sensor partially coated with the graphene oxide film has good sensitivity and very short response time. The developed approach of experimental data treatment can be used for calibration of various types of portable SAW sensors.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Kinetic characteristics of the SAW humidity sensor partially coated with graphene oxide thin film
Atomization of one or two microliter droplets of aqueous dispersion of graphene oxide (GO) by the surface acoustic wave (SAW) atomizer was used to deposit GO sensitive films of 15-30-nm thickness onto the surface of the SAW humidity sensor. Sensitivity of the sensors with these films as sensitive elements was calibrated over a wide range of humidity using a special procedure of preparation of standards, and adsorption kinetic curves for this process were obtained. The first-order rate kinetic equation with special additional linear term was shown to be adequate for modeling the kinetics of water adsorption onto the GO thin film. All parameters of this equation were calculated from least-squares fitting of experimental data. It was shown that the sensor partially coated with the graphene oxide film has good sensitivity and very short response time. The developed approach of experimental data treatment can be used for calibration of various types of portable SAW sensors.