Taichiro Amino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Taichiro Amino has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
M. Uomoto
Frontier Research Institute for Interdisciplinary Sciences (FRIS), Tohoku University, Sendai 980-8578, Japan
1 shared publicationMiyuki Uomoto
Frontier Research Institute for Interdisciplinary Sciences (FRIS), Tohoku University, Sendai, Miyagi, JAPAN
1 shared publication- Takehito Shimatsu
Tohoku University
1 shared publication - Takehito Shimatsu
Frontier Research Institute for Interdisciplinary Sciences (FRIS), Tohoku University, Sendai 980-8578, Japan
1 shared publication
Latest Publications
- 24 March 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SF) , SF1002
Bonding performance in atomic diffusion bonding of wafers using amorphous Si thin films with smooth surface
Amorphous Si films with a low surface roughness of 0.13 nm were used to examine the bonding performance of atomic diffusion bonding of quartz glass wafers at room temperature in vacuum. The high bonding strength was achieved for films with thickness δ of 2–50 nm: the blade could not be inserted between the bonded wafers. Using a vacuum chamber with a base pressure of 1 × 10 –6 Pa, the great bonding strength was maintained even with waiting time in vacuum of as long as 3.6 × 10 3 s from film deposition to bonding. The excellent bonding performance was almost equal to that achieved using Ti films.
- 24 March 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SF) , SF1002
Bonding performance in atomic diffusion bonding of wafers using amorphous Si thin films with smooth surface
Amorphous Si films with a low surface roughness of 0.13 nm were used to examine the bonding performance of atomic diffusion bonding of quartz glass wafers at room temperature in vacuum. The high bonding strength was achieved for films with thickness δ of 2–50 nm: the blade could not be inserted between the bonded wafers. Using a vacuum chamber with a base pressure of 1 × 10 –6 Pa, the great bonding strength was maintained even with waiting time in vacuum of as long as 3.6 × 10 3 s from film deposition to bonding. The excellent bonding performance was almost equal to that achieved using Ti films.
- Open Access
- 1 May 2021
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 10 (5) , 054008
Bonding Performance and Interface Contamination in Atomic Diffusion Bonding of Wafers Using Ti Thin Films
Room-temperature bonding performance of wafers using thin Ti films was examined as a function of waiting time t w in vacuum between film deposition and bonding. The surface free energy at bonded interface γ decreased as t w increased. However, results indicated that a γ value greater than 6.1 J m−2 is obtainable even at t w of 1 h or more at vacuum chamber base pressures lower than 1 × 10–6 Pa. Bonding apparatuses of three types with different vacuum base pressures were used for this study, but γ values obtained using the equipment showed an almost quantitatively identical reduction as the calculated total amount of residual gas adsorption on Ti film surfaces, G a, increased. This finding indicates that the interface contamination evaluated as G a played a dominant role in determining the γ reduction. Structural analysis revealed that the formation of reactive Ti–O layers on film surfaces prevented the crystal lattice rearrangement between Ti film surfaces, thereby leading to γ reduction. A few Langmuir of H2O adsorption prevented the crystal lattice rearrangement to a considerable degree. Moreover, surface roughness reduction of Ti films was effective at maintaining high bonding performance for a long waiting time.
- 1 May 2021
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 10 (5) , 054008
Open AccessBonding Performance and Interface Contamination in Atomic Diffusion Bonding of Wafers Using Ti Thin Films
Room-temperature bonding performance of wafers using thin Ti films was examined as a function of waiting time t w in vacuum between film deposition and bonding. The surface free energy at bonded interface γ decreased as t w increased. However, results indicated that a γ value greater than 6.1 J m−2 is obtainable even at t w of 1 h or more at vacuum chamber base pressures lower than 1 × 10–6 Pa. Bonding apparatuses of three types with different vacuum base pressures were used for this study, but γ values obtained using the equipment showed an almost quantitatively identical reduction as the calculated total amount of residual gas adsorption on Ti film surfaces, G a, increased. This finding indicates that the interface contamination evaluated as G a played a dominant role in determining the γ reduction. Structural analysis revealed that the formation of reactive Ti–O layers on film surfaces prevented the crystal lattice rearrangement between Ti film surfaces, thereby leading to γ reduction. A few Langmuir of H2O adsorption prevented the crystal lattice rearrangement to a considerable degree. Moreover, surface roughness reduction of Ti films was effective at maintaining high bonding performance for a long waiting time.