Jaakko Lehtinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jaakko Lehtinen has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Christian Bernd Hirschmann
University of Oulu, Department of Process and Environmental Engineering, Mass and Heat Transfer Process Laboratory, FI-90014, Oulu, Finland
1 shared publicationRiitta Liisa Keiski
University of Oulu, Department of Process and Environmental Engineering, Mass and Heat Transfer Process Laboratory, FI-90014, Oulu, Finland
1 shared publicationT. Kuusela
University of Turku
1 shared publicationTom Kuusela
University of Turku, Department of Physics and Astronomy, Laboratory of Optics and Spectroscopy, Vesilinnantie 5, FI-20014, Turku, Finland
1 shared publication
Latest Publications
- 23 August 2013
- Published by Springer Nature in Applied Physics B
- Vol. 115 (3) , 413-418
Broadly tunable quantum cascade laser in cantilever-enhanced photoacoustic infrared spectroscopy of solids
- 23 August 2013
- Published by Springer Nature in Applied Physics B
- Vol. 115 (3) , 413-418
Broadly tunable quantum cascade laser in cantilever-enhanced photoacoustic infrared spectroscopy of solids
- 1 August 2013
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 67 (8) , 846-850
Human Hair in the Identification of Cocaine Abuse with Cantilever-Enhanced Photoacoustic Spectroscopy and Principal Component Analysis
In this study, a novel approach combining different techniques, including Fourier transform infrared (FT-IR) spectroscopy, photoacoustic spectroscopy (PAS) with an interferometric cantilever microphone, and principal component analysis (PCA) along with a proper data preprocessing procedure, have been used in the investigation of hair samples for cocaine abuse. Hair fibers from cocaine-overdose patients have been measured using a simple procedure involving cantilever-enhanced photoacoustic Fourier transform infrared spectroscopy. In addition, a reference group of hair samples from subjects with no cocaine abuse has been measured. We present a first approach to discriminate the cocaine users from the reference group with the photoacoustic method and PCA. With proper data preprocessing methods, the two groups were successfully separated according to their spectra. The results were confirmed with two different classification methods independent of the principal component data analysis.
- 1 August 2013
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 67 (8) , 846-850
Human Hair in the Identification of Cocaine Abuse with Cantilever-Enhanced Photoacoustic Spectroscopy and Principal Component Analysis
In this study, a novel approach combining different techniques, including Fourier transform infrared (FT-IR) spectroscopy, photoacoustic spectroscopy (PAS) with an interferometric cantilever microphone, and principal component analysis (PCA) along with a proper data preprocessing procedure, have been used in the investigation of hair samples for cocaine abuse. Hair fibers from cocaine-overdose patients have been measured using a simple procedure involving cantilever-enhanced photoacoustic Fourier transform infrared spectroscopy. In addition, a reference group of hair samples from subjects with no cocaine abuse has been measured. We present a first approach to discriminate the cocaine users from the reference group with the photoacoustic method and PCA. With proper data preprocessing methods, the two groups were successfully separated according to their spectra. The results were confirmed with two different classification methods independent of the principal component data analysis.
- 28 July 2013
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 34 (8-9) , 1559-1568
Spectroscopic Studies of Human Hair, Nail, and Saliva Samples Using a Cantilever-Based Photoacoustic Detection
- 28 July 2013
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 34 (8-9) , 1559-1568
Spectroscopic Studies of Human Hair, Nail, and Saliva Samples Using a Cantilever-Based Photoacoustic Detection