Mark Harrison
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mark Harrison has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Alan Godfrey
School of Computer Science, Northumbria University, Newcastle upon Tyne, UK
1 shared publication - Alex P. Jones
Department of Plastic and Reconstructive Surgery, University Hospital of North Durham, North Road, Durham, County Durham DH1 5TW, United Kingdom
1 shared publication Alison Walker
Emergency Department, Harrogate and District NHS Foundation Trust, Harrogate, UK
1 shared publication- Amir Herman
Department of Orthopaedic Surgery, Assuta Ashdod Medical Center, Ashdod, Israel; Goldman School of Medicine, Ben-Gurion University of the Negev, Beer Sheva, Israel
1 shared publication Andrea Wootten
Emergency Department, Arrowe Park Hospital, Wirral University Teaching Hospital NHS Foundation Trust, Wirral, UK
1 shared publicationAndrew Appelboam
Emergency Department, Royal Devon & Exeter Hospital NHS Foundation Trust, Exeter, UK
1 shared publication
Latest Publications
- 30 October 2025
- Published by Wiley in Emergency Medicine Australasia
- Vol. 37 (6) , e70164
Non‐Invasive Management of Blunt Traumatic Pneumothorax—a Meta‐Analysis
Background and Importance: Traumatic pneumothoraces occur in 25% of patients sustaining traumatic chest injury. Tube thoracostomy carries a risk of major complications leading to the necessity of tube thoracostomy insertion for traumatic pneumothoraces to be challenged. Objectives: This meta‐analysis analyses current evidence relating to the management of traumatic pneumothorax and synthesises the evidence to determine whether clinicians can safely omit tube thoracostomy in patients with traumatic pneumothorax presenting to the Emergency Department (ED). Design: This meta‐analysis was performed by searching electronic databases. Papers were included for analysis if they used patients sustaining blunt trauma and compared tube thoracostomy to conservative management. Comparisons were made for those undergoing tube thoracostomy and those undergoing conservative management. Main Results: Fourteen studies comprising 1550 patients were included. There is a non‐significant combined pneumothorax progression rate of 12% for those observed, and 7.6% for those with a tube thoracostomy ( p = 0.8447) with an odds ratio of 1.33. There was an 11.9% rate for tube thoracostomy insertion among patients observed, and a 10.4% requirement for further tube thoracostomy placement in those already with a tube thoracostomy ( p = 0.3436) with an odds ratio of 0.553. For patients receiving positive pressure ventilation, the rates were 18% in observed patients compared to 9% of those with a tube thoracostomy ( p = 0.2848) with an odds ratio of 4.123. Conclusions: Conservative management of traumatic pneumothorax without positive pressure ventilation is a reasonable initial safe approach in the ED. Only ~12% of these patients will eventually require a tube thoracostomy.
- 30 October 2025
- Published by Wiley in Emergency Medicine Australasia
- Vol. 37 (6) , e70164
Non‐Invasive Management of Blunt Traumatic Pneumothorax—a Meta‐Analysis
Background and Importance: Traumatic pneumothoraces occur in 25% of patients sustaining traumatic chest injury. Tube thoracostomy carries a risk of major complications leading to the necessity of tube thoracostomy insertion for traumatic pneumothoraces to be challenged. Objectives: This meta‐analysis analyses current evidence relating to the management of traumatic pneumothorax and synthesises the evidence to determine whether clinicians can safely omit tube thoracostomy in patients with traumatic pneumothorax presenting to the Emergency Department (ED). Design: This meta‐analysis was performed by searching electronic databases. Papers were included for analysis if they used patients sustaining blunt trauma and compared tube thoracostomy to conservative management. Comparisons were made for those undergoing tube thoracostomy and those undergoing conservative management. Main Results: Fourteen studies comprising 1550 patients were included. There is a non‐significant combined pneumothorax progression rate of 12% for those observed, and 7.6% for those with a tube thoracostomy ( p = 0.8447) with an odds ratio of 1.33. There was an 11.9% rate for tube thoracostomy insertion among patients observed, and a 10.4% requirement for further tube thoracostomy placement in those already with a tube thoracostomy ( p = 0.3436) with an odds ratio of 0.553. For patients receiving positive pressure ventilation, the rates were 18% in observed patients compared to 9% of those with a tube thoracostomy ( p = 0.2848) with an odds ratio of 4.123. Conclusions: Conservative management of traumatic pneumothorax without positive pressure ventilation is a reasonable initial safe approach in the ED. Only ~12% of these patients will eventually require a tube thoracostomy.
- 16 February 2022
- Published by Elsevier in Physiotherapy
- Vol. 114, e43-e44
Active rehabilitation intervention following acute mild traumatic brain injury: A systematic review
- 16 February 2022
- Published by Elsevier in Physiotherapy
- Vol. 114, e43-e44
Active rehabilitation intervention following acute mild traumatic brain injury: A systematic review
- 10 January 2022
- Published by Elsevier in The Journal of Emergency Medicine
- Vol. 62 (2) , e13-e15
‘Cortical Hand’ in the Emergency Department: Two Case Reports
- 10 January 2022
- Published by Elsevier in The Journal of Emergency Medicine
- Vol. 62 (2) , e13-e15
‘Cortical Hand’ in the Emergency Department: Two Case Reports
Diagnostic accuracy of the T-MACS decision aid with a contemporary point-of-care troponin assay
Objectives The rapid turnaround time of point-of-care (POC) cardiac troponin (cTn) assays is highly attractive for crowded emergency departments (EDs). We evaluated the diagnostic accuracy of the Troponin-only Manchester Acute Coronary Syndromes (T-MACS) decision aid with a POC cTn assay. Methods In a prospective diagnostic accuracy study at eight EDs, we included patients with suspected acute coronary syndromes (ACS). Blood drawn on arrival and 3 hours later was analysed for POC cTnI (i-Stat, Abbott Point of Care). The primary outcome was a diagnosis of ACS, which included both an adjudicated diagnosis of acute myocardial infarction (AMI) based on serial laboratory cTn testing and major adverse cardiac events (death, AMI or coronary revascularisation) within 30 days. Results Of 716 patients included, 105 (14.7%) had ACS. Using serial POC cTnI concentrations over 3 hours could have ‘ruled out’ ACS in 198 (31.2%) patients with a sensitivity of 99.0% (95% CI 94.4% to 100.0%) and negative predictive value 99.5% (95% CI 96.5% to 99.9%). No AMIs were missed. T-MACS ‘ruled in’ ACS for 65 (10.4%) patients with a positive predictive value of 91.2% (95% CI 82.1% to 95.9%) and specificity 98.9% (97.6% to 99.6%). Conclusion With a POC cTnI assay, T-MACS could ‘rule out’ ACS for approximately one-third of patients within 3 hours while ‘ruling in’ ACS for another 10%. The rapid turnaround time and portability of the POC assay make this an attractive pathway for use in crowded EDs or urgent care centres. Future work should also evaluate use in the prehospital environment.
Diagnostic accuracy of the T-MACS decision aid with a contemporary point-of-care troponin assay
Objectives The rapid turnaround time of point-of-care (POC) cardiac troponin (cTn) assays is highly attractive for crowded emergency departments (EDs). We evaluated the diagnostic accuracy of the Troponin-only Manchester Acute Coronary Syndromes (T-MACS) decision aid with a POC cTn assay. Methods In a prospective diagnostic accuracy study at eight EDs, we included patients with suspected acute coronary syndromes (ACS). Blood drawn on arrival and 3 hours later was analysed for POC cTnI (i-Stat, Abbott Point of Care). The primary outcome was a diagnosis of ACS, which included both an adjudicated diagnosis of acute myocardial infarction (AMI) based on serial laboratory cTn testing and major adverse cardiac events (death, AMI or coronary revascularisation) within 30 days. Results Of 716 patients included, 105 (14.7%) had ACS. Using serial POC cTnI concentrations over 3 hours could have ‘ruled out’ ACS in 198 (31.2%) patients with a sensitivity of 99.0% (95% CI 94.4% to 100.0%) and negative predictive value 99.5% (95% CI 96.5% to 99.9%). No AMIs were missed. T-MACS ‘ruled in’ ACS for 65 (10.4%) patients with a positive predictive value of 91.2% (95% CI 82.1% to 95.9%) and specificity 98.9% (97.6% to 99.6%). Conclusion With a POC cTnI assay, T-MACS could ‘rule out’ ACS for approximately one-third of patients within 3 hours while ‘ruling in’ ACS for another 10%. The rapid turnaround time and portability of the POC assay make this an attractive pathway for use in crowded EDs or urgent care centres. Future work should also evaluate use in the prehospital environment.
- 1 March 2014
- Published by IMR Press in British Journal of Hospital Medicine
- Vol. 75 (3) , 132-135
Traumatic pneumothorax: a review of current practices
Traumatic pneumothoraces are a common presentation to any emergency department. This article explores the evidence behind thoracostomy drain insertion, and the necessity for the procedure on all patients.
- 1 March 2014
- Published by IMR Press in British Journal of Hospital Medicine
- Vol. 75 (3) , 132-135
Traumatic pneumothorax: a review of current practices
Traumatic pneumothoraces are a common presentation to any emergency department. This article explores the evidence behind thoracostomy drain insertion, and the necessity for the procedure on all patients.
- 3 September 2010
- Published by BMJ in Emergency Medicine Journal
- Vol. 28 (7) , 601-603
Patients' perspectives on injuries
Aim and Methods To assess the way different terms used to describe a fracture affect the understanding a patient has of that fracture. The perceived severity of the injury and how the patient expects to be treated were also recorded with a view to optimising patient understanding. Results There was a very significant difference between what doctors can potentially say and what the patient ultimately understood about the consultation. This could have a direct effect on the management the patient expects from the initial description and diagnosis. Conclusions It is important that doctors in the emergency department use terminology that is understood by the patient, as well as emphasising the potential seriousness of the injury. It is possibly better therefore to use informed lay terminology such as ‘a break in a bone’ rather than more formal vocabulary such ‘a fracture’ when discussing the diagnosis and treatment options.
- 3 September 2010
- Published by BMJ in Emergency Medicine Journal
- Vol. 28 (7) , 601-603
Patients' perspectives on injuries
Aim and Methods To assess the way different terms used to describe a fracture affect the understanding a patient has of that fracture. The perceived severity of the injury and how the patient expects to be treated were also recorded with a view to optimising patient understanding. Results There was a very significant difference between what doctors can potentially say and what the patient ultimately understood about the consultation. This could have a direct effect on the management the patient expects from the initial description and diagnosis. Conclusions It is important that doctors in the emergency department use terminology that is understood by the patient, as well as emphasising the potential seriousness of the injury. It is possibly better therefore to use informed lay terminology such as ‘a break in a bone’ rather than more formal vocabulary such ‘a fracture’ when discussing the diagnosis and treatment options.
- 1 June 2009
- Published by SAGE Publications in Foot & Ankle International
- Vol. 30 (6) , 545-550
Biomechanical Properties of New Mini Compression Screws
Background: The aim of the current study was to compare the compression forces achieved by the new commercial mini compression screws in cortical and cancellous bone. Materials and Methods: The following screws were tested: AO partially threaded 4-mm cancellous screw, AO 3.5- and 2.7- mm cortical screws (Synthes - USA), self-tapping cannulated 3-mm VisAntares (EOS - France), 3- and 2.3-mm Omnitech (Biotech - France), 3-mm Barouk (DePuy - France), and 3-mm Bold screws (Newdeal - France). The compression forces of screws in bone were tested using a load cell between pieces of longitudinally-split sheep tibias as a cortical and cancellous bone model. Results: The AO 3.5-mm, 2.7-mm cortical and 4.0-mm partially threaded cancellous headed screws provided significantly ( p < = 0.05) better compression forces than all the tested headless screws, both in cortical and cancellous bone. A loss of compression was noted when the headless screws were totally countersunk. Conclusion: The cortical and cancellous screws with heads provided superior compression than headless screws. Clinical Relevance: Headed screws may be preferable to headless differential pitch screws in situations where compression is important ie, arthrodeses or fracture fixation. Care should be taken not to countersink the headless screws during insertion into cortical bone.
- 1 June 2009
- Published by SAGE Publications in Foot & Ankle International
- Vol. 30 (6) , 545-550
Biomechanical Properties of New Mini Compression Screws
Background: The aim of the current study was to compare the compression forces achieved by the new commercial mini compression screws in cortical and cancellous bone. Materials and Methods: The following screws were tested: AO partially threaded 4-mm cancellous screw, AO 3.5- and 2.7- mm cortical screws (Synthes - USA), self-tapping cannulated 3-mm VisAntares (EOS - France), 3- and 2.3-mm Omnitech (Biotech - France), 3-mm Barouk (DePuy - France), and 3-mm Bold screws (Newdeal - France). The compression forces of screws in bone were tested using a load cell between pieces of longitudinally-split sheep tibias as a cortical and cancellous bone model. Results: The AO 3.5-mm, 2.7-mm cortical and 4.0-mm partially threaded cancellous headed screws provided significantly ( p < = 0.05) better compression forces than all the tested headless screws, both in cortical and cancellous bone. A loss of compression was noted when the headless screws were totally countersunk. Conclusion: The cortical and cancellous screws with heads provided superior compression than headless screws. Clinical Relevance: Headed screws may be preferable to headless differential pitch screws in situations where compression is important ie, arthrodeses or fracture fixation. Care should be taken not to countersink the headless screws during insertion into cortical bone.
- 1 February 2009
- Published by BMJ in Emergency Medicine Journal
- Vol. 26 (2) , 150
No Wii cause for concern
As anyone with one of these new generation computers will verify, the Wii Sports game (in particular, the boxing) is quite strenuous for those not accustomed to vigorous upper arm exercise—even in generally “fit” individuals. The good news is that this pain seems to last for roughly 1 day and seems to be much less severe than a typical strain or sprain.
- 1 February 2009
- Published by BMJ in Emergency Medicine Journal
- Vol. 26 (2) , 150
No Wii cause for concern
As anyone with one of these new generation computers will verify, the Wii Sports game (in particular, the boxing) is quite strenuous for those not accustomed to vigorous upper arm exercise—even in generally “fit” individuals. The good news is that this pain seems to last for roughly 1 day and seems to be much less severe than a typical strain or sprain.
- 1 June 2007
- Vol. 73 (3) , 377-85
Comparison of autologous transfusion drains versus no drain in total knee arthroplasty.
Primary total knee arthroplasty is associated with blood loss both during surgery and in the immediate postoperative period, that may require allogenic blood transfusion. In view of the risks and financial implications of using allogenic blood, an accepted solution has been to utilise autotransfusion drains in the postoperative period thus allowing re-infusion of a patient's own blood. A number of studies have compared retransfusion techniques with standard drain use, but few report comparison with no drain use at all. We analysed data from patients undergoing primary total knee arthroplasty within our unit over an 18-month period. A total of 121 patients were included in the study: 53 received retransfusion drains whilst the remaining 68 received no drain at all. The mean postoperative haemoglobin drop was not significantly different between the two groups (p > 0.05). In the retransfusion group only one patient (2%) required allogenic blood transfusion postoperatively, whilst 4 of the 68 (6%) did so in the control group. This difference was not statistically significant either. This study showed a low rate of allogenic blood use postoperatively (< 5%) where either a retransfusion drain or no drain was used at all. However because there was no measurable difference between the two, we conclude that using a retransfusion technique does not appear to be of significant financial or clinical benefit with regards to allogenic blood transfusions compared with using no drain.
- 1 June 2007
- Vol. 73 (3) , 377-85
Comparison of autologous transfusion drains versus no drain in total knee arthroplasty.
Primary total knee arthroplasty is associated with blood loss both during surgery and in the immediate postoperative period, that may require allogenic blood transfusion. In view of the risks and financial implications of using allogenic blood, an accepted solution has been to utilise autotransfusion drains in the postoperative period thus allowing re-infusion of a patient's own blood. A number of studies have compared retransfusion techniques with standard drain use, but few report comparison with no drain use at all. We analysed data from patients undergoing primary total knee arthroplasty within our unit over an 18-month period. A total of 121 patients were included in the study: 53 received retransfusion drains whilst the remaining 68 received no drain at all. The mean postoperative haemoglobin drop was not significantly different between the two groups (p > 0.05). In the retransfusion group only one patient (2%) required allogenic blood transfusion postoperatively, whilst 4 of the 68 (6%) did so in the control group. This difference was not statistically significant either. This study showed a low rate of allogenic blood use postoperatively (< 5%) where either a retransfusion drain or no drain was used at all. However because there was no measurable difference between the two, we conclude that using a retransfusion technique does not appear to be of significant financial or clinical benefit with regards to allogenic blood transfusions compared with using no drain.