Helen Dnp Rostata-Pesola
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Helen Dnp Rostata-Pesola has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Gene Raymond Pesola
Medicine (Pulmon/CCMed), Harlem Hospital/Columbia Univ., New York, NY, United States
9 shared publications Michael J. Nelson
2 shared publicationsRichard E. Westfal
2 shared publicationsArthur F. Saari
1 shared publicationAyse Md (Chief Of Gastroenterology And Hepatology) Aytaman
Section of Gastroenterology, Department of Medicine, Veterans Affairs New York Harbor Health Care System, Brooklyn, New York
1 shared publicationD A Pesola
1 shared publication
Latest Publications
- 1 April 2020
- Published by Wolters Kluwer Health in Journal of the American Association of Nurse Practitioners
- Vol. 33 (8) , 646-651
Hepatitis C virus screening at a Veterans Administration Hospital in New York City
Background: Asymptomatic hepatitis C virus (HCV) infection has the highest prevalence in “baby boomers” born in 1945 through 1965. New York State mandates that all persons born during this period be screened at least once for hepatitis C. Local problem: Military veteran HCV screening is often missed during primary care visits. Methods: After baseline screening, provider education with and without an HCV education dashboard of information in the Electronic Medical Record system was used to determine if screening proportions could be improved. The Chi-square and Z-test for independent proportions compared after with before education screening. The odds ratio compared after versus before screening odds. Interventions: Two interventions were tested. One was provider education with a 30-minute lecture. The second was the lecture with addition of an HCV education computer dashboard. Results: The Chi-square test and Z-test comparing the month immediately after provider education was significant for increased screening (p < .01) compared with baseline. There was a 2.04-fold (95% confidence interval, 1.31–3.20) greater odds of screening in the month after education. If two or more months went by after education, the effect of education no longer improved screening proportions. Provider education plus the use of HCV education dashboard did not improve screening from baseline to the month immediately after screening (p = .95). Conclusion: Provider education significantly improved HCV screening the month immediately after education, then regressed toward baseline. Adding an HCV education dashboard to education did not improve screening. To maintain elevated screening proportions, provider screening education must be reinforced on a frequent basis for sustained effect.
- 1 April 2020
- Published by Wolters Kluwer Health in Journal of the American Association of Nurse Practitioners
- Vol. 33 (8) , 646-651
Hepatitis C virus screening at a Veterans Administration Hospital in New York City
Background: Asymptomatic hepatitis C virus (HCV) infection has the highest prevalence in “baby boomers” born in 1945 through 1965. New York State mandates that all persons born during this period be screened at least once for hepatitis C. Local problem: Military veteran HCV screening is often missed during primary care visits. Methods: After baseline screening, provider education with and without an HCV education dashboard of information in the Electronic Medical Record system was used to determine if screening proportions could be improved. The Chi-square and Z-test for independent proportions compared after with before education screening. The odds ratio compared after versus before screening odds. Interventions: Two interventions were tested. One was provider education with a 30-minute lecture. The second was the lecture with addition of an HCV education computer dashboard. Results: The Chi-square test and Z-test comparing the month immediately after provider education was significant for increased screening (p < .01) compared with baseline. There was a 2.04-fold (95% confidence interval, 1.31–3.20) greater odds of screening in the month after education. If two or more months went by after education, the effect of education no longer improved screening proportions. Provider education plus the use of HCV education dashboard did not improve screening from baseline to the month immediately after screening (p = .95). Conclusion: Provider education significantly improved HCV screening the month immediately after education, then regressed toward baseline. Adding an HCV education dashboard to education did not improve screening. To maintain elevated screening proportions, provider screening education must be reinforced on a frequent basis for sustained effect.
- 1 November 2010
- Published by Taylor & Francis in Journal of Asthma
- Vol. 47 (10) , 1067-1071
Comparison of the ATS Versus EU Mini Wright Peak Flow Meter in Normal Volunteers
The American Thoracic Society (ATS) and European Union (EU) have precise and accurate Mini Wright peak flow meters. The purpose of this investigation was to compare both 1) for accuracy using a pneumotachometer, 2) in volunteers to determine whether they are interchangeable, and 3) to spirometrically predicted peak flows. Lab testing: A pneumotachometer was connected in series with each peak flow meter and varying flows pushed through both meters for comparison. Human subjects: Nonsmoking adult volunteers did three standing peak flows. The order of peak flow meter used was random. The best of three efforts was used for analysis. The t-test, concordance correlation coefficient (CCC), Deming regression, and Bland-Altman plot were the analytic strategies used to determine agreement. Peak flow results were compared to spirometrically predicted values. Fifty-seven volunteers, average age 37 ± 12 years and mean BMI 24.9 ± 2.5 years, were included. The average peak flows were different at 541 ± 114 and 526 ± 112 L/min for the ATS and EU meters, respectively (p < .01). Both peak flow meter values were significantly different than spirometrically predicted values of 483 ± 86 L/min (p < .01). The CCC was 0.98 (0.97-0.99) and regression revealed a slope and y-intercept consistent with 1 and 0, respectively. The Bland-Altman plot revealed no increase in scatter of values over the range of peak flows versus the difference with a mean bias of 15 ± 15 L/min. Laboratory testing revealed that the ATS and EU peak flow meters read 3.0 ± 2.1% above and -2.0 ± 1.5% below the comparison pneumotachometer, respectively. The pneumotachometer comparison was significantly different for both meters at p < .01, paired t-test. The ATS peak flow meter reads 2.8% higher than the EU peak flow meter across a range of flows. Both meters have similar accuracy with a different bias compared with a pneumotachometer. Finally, both peak flow meters read slightly and significantly higher than spirometrically derived peak flows. Therefore, the peak flow meters are not interchangeable and both may obtain slightly higher values than those determined using current spirometrically derived prediction equations.
- 1 November 2010
- Published by Taylor & Francis in Journal of Asthma
- Vol. 47 (10) , 1067-1071
Comparison of the ATS Versus EU Mini Wright Peak Flow Meter in Normal Volunteers
The American Thoracic Society (ATS) and European Union (EU) have precise and accurate Mini Wright peak flow meters. The purpose of this investigation was to compare both 1) for accuracy using a pneumotachometer, 2) in volunteers to determine whether they are interchangeable, and 3) to spirometrically predicted peak flows. Lab testing: A pneumotachometer was connected in series with each peak flow meter and varying flows pushed through both meters for comparison. Human subjects: Nonsmoking adult volunteers did three standing peak flows. The order of peak flow meter used was random. The best of three efforts was used for analysis. The t-test, concordance correlation coefficient (CCC), Deming regression, and Bland-Altman plot were the analytic strategies used to determine agreement. Peak flow results were compared to spirometrically predicted values. Fifty-seven volunteers, average age 37 ± 12 years and mean BMI 24.9 ± 2.5 years, were included. The average peak flows were different at 541 ± 114 and 526 ± 112 L/min for the ATS and EU meters, respectively (p < .01). Both peak flow meter values were significantly different than spirometrically predicted values of 483 ± 86 L/min (p < .01). The CCC was 0.98 (0.97-0.99) and regression revealed a slope and y-intercept consistent with 1 and 0, respectively. The Bland-Altman plot revealed no increase in scatter of values over the range of peak flows versus the difference with a mean bias of 15 ± 15 L/min. Laboratory testing revealed that the ATS and EU peak flow meters read 3.0 ± 2.1% above and -2.0 ± 1.5% below the comparison pneumotachometer, respectively. The pneumotachometer comparison was significantly different for both meters at p < .01, paired t-test. The ATS peak flow meter reads 2.8% higher than the EU peak flow meter across a range of flows. Both meters have similar accuracy with a different bias compared with a pneumotachometer. Finally, both peak flow meters read slightly and significantly higher than spirometrically derived peak flows. Therefore, the peak flow meters are not interchangeable and both may obtain slightly higher values than those determined using current spirometrically derived prediction equations.
- 1 January 2003
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 31 (1) , 335-336
Critical Care Excellence
- 1 January 2003
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 31 (1) , 335-336
Critical Care Excellence
- 1 April 2002
- Published by Wiley in Academic Emergency Medicine
- Vol. 9 (4) , 342-345
The Normal Difference in Bilateral Indirect Blood Pressure Recordings in Hypertensive Individuals
If there is a significant dichotomy between bilateral systolic blood pressure determinations in both arms in hypertensive individuals, it is often taken as a sign of underlying pathology. The primary objective was to determine what the normal variation might be for a significant difference between blood pressures in both arms. A clinically significant difference was chosen as a systolic blood pressure value greater than 10 mm Hg between the upper extremities, as is commonly quoted at the bedside and in the literature. Bilateral indirect blood pressure determinations were obtained in 100 subjects with hypertension in the sitting position. The blood pressure was obtained by two observers, one the recorder and the other who obtained the blood pressure but was blinded to the actual values taken. The order of blood pressure determination in the first arm was determined prior to the study from a table of random numbers. The coefficient of variation in obtaining the blood pressure in each arm was determined in 5 of the 100 subjects. The age, sex, and handedness of each individual were recorded as demographic variables. The average left and right systolic blood pressures were 139 +/- 22 and 141 +/- 22 mm Hg, respectively. The average left and right diastolic blood pressures were 78 +/- 12 and 79 +/- 13 mm Hg, respectively. There was no significant difference between left minus right systolic or diastolic differences (paired t-test). There was no significant difference between systolic or diastolic blood pressures between gender or between left- and right-handed individuals (nonpaired t-test). The average coefficients of variation for taking right and left arm systolic pressures were 2.90% and 1.32%, respectively. Eighteen subjects (18%) had differences in systolic blood pressure between both arms exceeding 10 mm Hg (10% to 26%, 95% confidence interval). Differences of more than 10 mm Hg in indirect systolic blood pressure recordings between arms are frequent in asymptomatic hypertensive individuals and do not per se indicate any pathologic condition. In the right clinical situation, differences that are noted should be repeated and should be added to the total clinical picture when used to determine whether a pathologic condition is present. Assuming no significant aortic or subclavian disease in the population tested, the specificity of the bilateral blood pressure test was 82%.
- 1 April 2002
- Published by Wiley in Academic Emergency Medicine
- Vol. 9 (4) , 342-345
The Normal Difference in Bilateral Indirect Blood Pressure Recordings in Hypertensive Individuals
If there is a significant dichotomy between bilateral systolic blood pressure determinations in both arms in hypertensive individuals, it is often taken as a sign of underlying pathology. The primary objective was to determine what the normal variation might be for a significant difference between blood pressures in both arms. A clinically significant difference was chosen as a systolic blood pressure value greater than 10 mm Hg between the upper extremities, as is commonly quoted at the bedside and in the literature. Bilateral indirect blood pressure determinations were obtained in 100 subjects with hypertension in the sitting position. The blood pressure was obtained by two observers, one the recorder and the other who obtained the blood pressure but was blinded to the actual values taken. The order of blood pressure determination in the first arm was determined prior to the study from a table of random numbers. The coefficient of variation in obtaining the blood pressure in each arm was determined in 5 of the 100 subjects. The age, sex, and handedness of each individual were recorded as demographic variables. The average left and right systolic blood pressures were 139 +/- 22 and 141 +/- 22 mm Hg, respectively. The average left and right diastolic blood pressures were 78 +/- 12 and 79 +/- 13 mm Hg, respectively. There was no significant difference between left minus right systolic or diastolic differences (paired t-test). There was no significant difference between systolic or diastolic blood pressures between gender or between left- and right-handed individuals (nonpaired t-test). The average coefficients of variation for taking right and left arm systolic pressures were 2.90% and 1.32%, respectively. Eighteen subjects (18%) had differences in systolic blood pressure between both arms exceeding 10 mm Hg (10% to 26%, 95% confidence interval). Differences of more than 10 mm Hg in indirect systolic blood pressure recordings between arms are frequent in asymptomatic hypertensive individuals and do not per se indicate any pathologic condition. In the right clinical situation, differences that are noted should be repeated and should be added to the total clinical picture when used to determine whether a pathologic condition is present. Assuming no significant aortic or subclavian disease in the population tested, the specificity of the bilateral blood pressure test was 82%.
- 1 January 2001
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 19 (1) , 43-45
The normal difference in bilateral indirect blood pressure recordings in normotensive individuals
- 1 January 2001
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 19 (1) , 43-45
The normal difference in bilateral indirect blood pressure recordings in normotensive individuals
- Open Access
- 1 July 2000
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 18 (4) , 441-443
Spiral CT diagnosis of pulmonary embolus
- 1 July 2000
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 18 (4) , 441-443
Open AccessSpiral CT diagnosis of pulmonary embolus
- 1 May 1999
- Vol. 8 (3) , 204
Cardiac biomarkers.
- 1 October 1997
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 25 (10) , 1762
Knowledge Base and Pulmonary Artery Catheterization
- 1 October 1997
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 25 (10) , 1762
Knowledge Base and Pulmonary Artery Catheterization