MSMithu Sarkar

Mithu Sarkar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mithu Sarkar has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Performance Analysis of Floating Solar Photovoltaic System for Humid and Saline Conditions

    by Shriram Jorvekar, Saniya Kalmani, Anik Goswami, Krishna Kumba, Mithu Sarkar

    Floating solar photovoltaic (FSPV) systems have emerged as a promising alternative to conventional land-based photovoltaic (LSPV) systems by reducing land-use constraints and improving electrical performance through the natural cooling effect of water bodies. However, long-term deployment in humid and saline coastal environments may accelerate moisture ingress, salt deposition, and corrosion, reducing system reliability and energy generation. This study presents a comparative performance assessment of a conventional LSPV system, a freshwater FSPV system, and an FSPV system operating under humid and saline conditions using the System Advisor Model. All three systems were modeled with identical installed capacities, module technologies, inverter configurations, and meteorological inputs to isolate the influence of environmental conditions on system performance. The freshwater FSPV system generated 14 900 kWh of annual alternating current energy in the first year compared with 14 248 kWh for the LSPV system, corresponding to an improvement of approximately 4%–5%. The direct current capacity factor increased from 16.30% to 18.90%, the energy yield improved from 1424 to 1656 kWh/kW, and the performance ratio increased from 0.71 to 0.82 because of lower module operating temperatures. When humidity- and salinity-induced degradation was considered, the annual energy generation decreased to 14 400 kWh, the performance ratio declined to 0.72, and the lifetime energy output reduced to approximately 6347 kWh after 25 years owing to accelerated corrosion. The results demonstrate that freshwater FSPV systems provide superior energy performance compared with LSPV systems. However, their long-term advantages in coastal environments can be substantially reduced by humidity- and salinity-induced degradation, highlighting the need for corrosion-resistant materials, improved encapsulation, and effective maintenance strategies for reliable longterm operation.

  • Open Access

    Resilient fixed-order damping controller for low-frequency inter-area oscillations in power systems under communication failures

    by Mithu Sarkar, Krishna Kumba, Anik Goswami, Saurav Gupta, Pritam Bhattacharjee, Sandipan Patra

    Low-frequency inter-area oscillations (LFOs) pose a critical challenge to small-signal stability, affecting the reliable operation of interconnected power systems. These oscillations can reduce tie-line power transfer capability and weaken overall system performance. This paper proposes, for the first time, a robust fixed low-order two-input single-output (TISO) damping controller based on dual wide-area signals to mitigate the effects of communication failures and time delays on system stability. Inter-area modes can be effectively observed from multiple locations and controlled from a single point, which motivates the use of a wide-area damping controller (WADC). Communication failures and time delays are important challenges in wide-area control, and delays are modeled using the Padé approximation. The controller is designed by optimizing key performance measures, such as the $$H_{\infty }$$ norm, spectral abscissa, and complex stability radius, to improve the robustness and stability of the system under uncertain conditions. The proposed controller improves system resilience by using the two most observable wide-area signals associated with critical inter-area modes. Kundur’s 11-bus system and the IEEE 39-bus test system are used to validate the proposed method. Simulation results show that the controller effectively improves the damping of inter-area oscillations under normal conditions and maintains stable performance even in the presence of communication failures and delays.

  • Open Access

    DC-DC Power Conversion Techniques for Next-Generation EV Chargers: Trends, Challenges, and Future Directions

    by Krishna Kumba, Nawin Ra, Mithu Sarkar, R Vijayapriya, Patri Upender, Venkateswarlu Gundu

    The rapid proliferation of electric vehicles (EVs) has intensified the demand for advanced, efficient, and scalable battery charging systems. DC-DC power converters play a critical role in regulating energy transfer between the grid, intermediate power buses, and EV batteries within modern charging architectures. This paper presents a comprehensive review of DC-DC converter technologies for next-generation EV charging systems from a unified system-level perspective. The study first introduces an integrated EV power electronics architecture highlighting the role of bidirectional power conversion in grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operation. A functional taxonomy of converter architectures is then developed to classify existing solutions based on power flow direction, switching strategy, integration level, and application suitability. Furthermore, a comparative evaluation framework is presented to analyze key trade-offs among major converter families in terms of efficiency, power density, semiconductor compatibility, control complexity, and scalability for fast-charging infrastructure. The review also discusses enabling technologies such as wide-bandgap semiconductor devices (SiC and GaN), magnetic integration techniques, and intelligent control strategies. In addition, emerging design challenges including thermal management, electromagnetic interference mitigation, and system-level integration are examined. Finally, a future research roadmap is proposed to highlight promising directions in converter architectures, integrated magnetics, artificial-intelligence-assisted control, and grid-interactive charging systems. This work provides a structured analytical perspective that bridges converter design innovations with the evolving requirements of next-generation EV charging infrastructure.


  • Open Access

    Optimal placement of H ∞ loop shaping damping controller using Dynamic Relative Gain Array

    by Mithu Sarkar, Debdeep Saha, Krishna Kumba, Venkateshwarlu Gundu

    Low-damping inter-area oscillation is a severe problem for the smooth operation of the interconnected power system. These oscillations are observed due to the bulk power transmission from one area to another through a weak tie line. The power system becomes unstable or even blackout due to such oscillations. Hence, it is necessary to identify these oscillations accurately. This paper deals with the identification of different electromechanical modes and the optimal placement of a damping controller in the power system. Dynamic Relative Gain Array (DRGA) tools are adopted to identify the optical location of the Power System Stabilizers (PSS) to damp out the inter-area oscillations. In a Multiple-Input Multiple-Output (MIMO) system, the DGRA number gives an idea of the interaction of the different control loops. DRGA identified the control loop with the least interaction with others. The parameters of the PSS are optimally determined using a residue-based approach. A loop-shaping (LS) based H ∞ controller is also proposed and optimally placed using the DRGA approach for further improving the damping of the inter-area oscillations. The DRGA analysis approach is compared with the model analysis approach like the speed-based residues, and perticification factor analysis approaches. IEEE-39 bus test system is used for verifying the damping performance of the proposed controllers. It is verified from the obtained results that H ∞ LS controller is optically placed and the damping of the inter-area oscillations is improved effectively.


  • Open Access

    An Evaluation of Battery Degradation and Predictive Methods Under Resistive Load Caused by Intermittent Solar Radiation

    by Krishna Kumba, Sishaj P. Simon, Venkateswarlu Gundu, Patri Upender, Nawin Ra, Mithun Sarkar

    The most versatile resource for storing energy is one that can rapidly charge or discharge while supporting the use of renewable energy. As renewable energy sources advance rapidly, batteries play a pivotal role in this progress. When integrating battery energy storage into a renewable energy system, it’s crucial to address the issue of battery degradation while implementing operational strategies. Furthermore, since solar irradiation varies due to changing cloud conditions, it can impact how batteries charge and discharge. This study focuses on investigating battery degradation and lifetime. Experimental work is being conducted with lead acid batteries connected to a solar photovoltaics system. The paper provides a detailed investigation of commonly used methods for predicting battery lifespan. It also analyzes aspects such as the effects of depth of discharge (DoD) and battery charge/discharge on temperature changes due to degradation. Using the coarse average approach, global battery aging, weighted Ah aging method, and RFC method, this paper estimates the DoD, temperature, life cycle loss (%), and lifespan and evaluates the extent of battery degradation. The battery lifespan is estimated using this method to be 8.42, 8.72, 8.33, and 8.93 years, respectively.


  • H∞ design of wide-area controller for damping inter-area oscillation in power system

    by Abhilash Patel, Mithu Sarkar, Sandip Ghosh, Bidyadhar Subudhi

    This paper demonstrates synthesis of a robust wide-area controller for damping inter-area power system oscillation. A wide-area damping controller is more effective in damping inter-area modes in power system as it takes remote signal as feedback in which inter-area oscillations strongly observable. However, with the involvement of remote signal time-delay is introduced in the feedback loop causing limitation in performance and design. An H∞ controller with regional pole placement controller is designed in this paper. Time-delay is Pade approximated for controller synthesis. Finally, the designed controller is validated through a two-area power system.


  • Effect of UPFC allocation on transmission system power loss

    by Mithu Sarkar

    A unified power flow controller (UPFC) is an advanced member of the group of flexible AC transmission systems (FACTS). In this paper, the performance of UPFC is investigated to minimize the power loss in the transmission line using load flow analysis. Loss allocation is an important aspect in determining the cost of power transmission. This paper focuses on the steady-state modeling of UPFC for the implementation in the Newton-Raphson (NR) power flow algorithm. A MATLAB program has been developed to implement the UPFC in the Newton-Raphson (NR) power flow program. Case studies have been performed on IEEE 30-bus system to minimize the transmission power losses. The effects of UPFC allocation on power system steady-state operation have been investigated.